메뉴 건너뛰기




Volumn 35, Issue 1, 2012, Pages 35-44

Prevention of esophageal thermal injury during radiofrequency ablation for atrial fibrillation

Author keywords

Atrial fibrillation; Esophageal temperature monitoring; Esophageal ulceration; Left atrium; Radiofrequency ablation

Indexed keywords

BODY MASS; CATHETER ABLATION; COOLING; ENDOSCOPIC ECHOGRAPHY; ENDOSCOPY; ESOPHAGEAL THERMAL INJURY; ESOPHAGUS ULCER; HEART ATRIUM FIBRILLATION; HUMAN; LUMINAL ESOPHAGEAL TEMPERATURE; PRIORITY JOURNAL; REVIEW; RISK REDUCTION; TEMPERATURE; TEMPERATURE MEASUREMENT; THERMAL INJURY;

EID: 84866097170     PISSN: 1383875X     EISSN: 15728595     Source Type: Journal    
DOI: 10.1007/s10840-011-9655-0     Document Type: Review
Times cited : (37)

References (53)
  • 1
    • 22044437071 scopus 로고    scopus 로고
    • Acute pyloric spasm and gastric hypomotility: An extracardiac adverse effect of percutaneous radiofrequency ablation for atrial fibrillation
    • 16022963 10.1016/j.jacc.2005.04.030
    • Shah, D., Dumonceau, J. M., Burri, H., Sunthorn, H., Schroft, A., Gentil-Baron, P., et al. (2005). Acute pyloric spasm and gastric hypomotility: an extracardiac adverse effect of percutaneous radiofrequency ablation for atrial fibrillation. Journal of the American College of Cardiology, 46, 327-330.
    • (2005) Journal of the American College of Cardiology , vol.46 , pp. 327-330
    • Shah, D.1    Dumonceau, J.M.2    Burri, H.3    Sunthorn, H.4    Schroft, A.5    Gentil-Baron, P.6
  • 2
    • 0033460265 scopus 로고    scopus 로고
    • Temperature controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart
    • 10525251 10.1023/A:1009840004782 1:STN:280:DyaK1MvlsFWquw%3D%3D
    • Anfinsen, O. G., Aass, H., Kongsgaard, E., Foerster, A., Scott, H., & Amlie, J. P. (1999). Temperature controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart. Journal of Interventional Cardiac Electrophysiology, 3, 343-351.
    • (1999) Journal of Interventional Cardiac Electrophysiology , vol.3 , pp. 343-351
    • Anfinsen, O.G.1    Aass, H.2    Kongsgaard, E.3    Foerster, A.4    Scott, H.5    Amlie, J.P.6
  • 3
    • 4444229385 scopus 로고    scopus 로고
    • Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation
    • 15333097 10.1046/j.1540-8167.2004.04083.x
    • Scanavacca, M. I., D'Avila, A., Parga, J., & Sosa, E. (2004). Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation. Journal of Cardiovascular Electrophysiology, 15(8), 960-962.
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.8 , pp. 960-962
    • Scanavacca, M.I.1    D'Avila, A.2    Parga, J.3    Sosa, E.4
  • 4
    • 2942519274 scopus 로고    scopus 로고
    • Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation
    • 15159294 10.1161/01.CIR.0000131866.44650.46
    • Pappone, C., Oral, H., Santinelli, V., Vicedomini, G., Lang, C. C., Manguso, F., et al. (2004). Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation. Circulation, 109(22), 2724-2726.
    • (2004) Circulation , vol.109 , Issue.22 , pp. 2724-2726
    • Pappone, C.1    Oral, H.2    Santinelli, V.3    Vicedomini, G.4    Lang, C.C.5    Manguso, F.6
  • 6
    • 33749045421 scopus 로고    scopus 로고
    • Esophageal imaging and strategies for avoiding injury during left atrial ablation for atrial fibrillation
    • 17018343 10.1016/j.hrthm.2006.06.006
    • Ren, J. F., Lin, D., Marchlinski, F. E., Callans, D. J., & Patel, V. (2006). Esophageal imaging and strategies for avoiding injury during left atrial ablation for atrial fibrillation. Heart Rhythm, 3(10), 1156-1161.
    • (2006) Heart Rhythm , vol.3 , Issue.10 , pp. 1156-1161
    • Ren, J.F.1    Lin, D.2    Marchlinski, F.E.3    Callans, D.J.4    Patel, V.5
  • 7
    • 23044477164 scopus 로고    scopus 로고
    • Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium
    • 16027254 10.1161/CIRCULATIONAHA.104.509612
    • Cummings, J. E., Schweikert, R. A., Saliba, W. I., Burkhardt, D., Brachmann, J., Gunther, J., et al. (2005). Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium. Circulation, 112, 459-464.
    • (2005) Circulation , vol.112 , pp. 459-464
    • Cummings, J.E.1    Schweikert, R.A.2    Saliba, W.I.3    Burkhardt, D.4    Brachmann, J.5    Gunther, J.6
  • 8
    • 28244462488 scopus 로고    scopus 로고
    • Movement of the esophagus during left atrial catheter ablation for atrial fibrillation
    • 16325049 10.1016/j.jacc.2005.08.042
    • Good, E., Oral, H., Lemola, K., Han, J., Tamirisa, K., Igic, P., et al. (2005). Movement of the esophagus during left atrial catheter ablation for atrial fibrillation. Journal of the American College of Cardiology, 46(11), 2107-2110.
    • (2005) Journal of the American College of Cardiology , vol.46 , Issue.11 , pp. 2107-2110
    • Good, E.1    Oral, H.2    Lemola, K.3    Han, J.4    Tamirisa, K.5    Igic, P.6
  • 9
    • 33749078523 scopus 로고    scopus 로고
    • Prevention of esophageal injury during catheter ablation of atrial fibrillation: Is intracardiac echocardiography the answer?
    • 17018344 10.1016/j.hrthm.2006.06.019
    • Calkins, H. (2006). Prevention of esophageal injury during catheter ablation of atrial fibrillation: is intracardiac echocardiography the answer? Heart Rhythm, 3, 1162-1163.
    • (2006) Heart Rhythm , vol.3 , pp. 1162-1163
    • Calkins, H.1
  • 10
    • 59449098640 scopus 로고    scopus 로고
    • A nationwide survey on the prevalence of atrioesophageal fistula after left atrial radiofrequency catheter ablation
    • 18836822 10.1007/s10840-008-9307-1
    • Ghia, K. K., Chugh, A., Good, E., Pelosi, F., Jongnarangsin, K., Bogun, F., et al. (2009). A nationwide survey on the prevalence of atrioesophageal fistula after left atrial radiofrequency catheter ablation. Journal of Interventional Cardiac Electrophysiology, 24, 33-36.
    • (2009) Journal of Interventional Cardiac Electrophysiology , vol.24 , pp. 33-36
    • Ghia, K.K.1    Chugh, A.2    Good, E.3    Pelosi, F.4    Jongnarangsin, K.5    Bogun, F.6
  • 11
    • 69249170000 scopus 로고    scopus 로고
    • Complications of atrial fibrillation ablation in a high-volume center in 1,000 procedures: Still cause for concern?
    • 19490383 10.1111/j.1540-8167.2009.01493.x
    • Dagres, N., Hindricks, G., Kottkamp, H., Sommer, P., Gaspar, T., Bode, K., et al. (2009). Complications of atrial fibrillation ablation in a high-volume center in 1,000 procedures: still cause for concern? Journal of Cardiovascular Electrophysiology, 20, 1014-1019.
    • (2009) Journal of Cardiovascular Electrophysiology , vol.20 , pp. 1014-1019
    • Dagres, N.1    Hindricks, G.2    Kottkamp, H.3    Sommer, P.4    Gaspar, T.5    Bode, K.6
  • 12
    • 34249298673 scopus 로고    scopus 로고
    • Time course of esophageal lesions after catheter ablation with cryothermal and radiofrequency ablation: Implication for atrio-esophageal fistula formation after catheter ablation for atrial fibrillation
    • 17428270 10.1111/j.1540-8167.2007.00790.x
    • Ripley, K. L., Gage, A. A., Olsen, D. B., Van Vleet, J. F., Lau, C. P., & Tse, H. F. (2007). Time course of esophageal lesions after catheter ablation with cryothermal and radiofrequency ablation: implication for atrio-esophageal fistula formation after catheter ablation for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 18(6), 642-646.
    • (2007) Journal of Cardiovascular Electrophysiology , vol.18 , Issue.6 , pp. 642-646
    • Ripley, K.L.1    Gage, A.A.2    Olsen, D.B.3    Van Vleet, J.F.4    Lau, C.P.5    Tse, H.F.6
  • 13
    • 70349466797 scopus 로고    scopus 로고
    • Esophageal capsule endoscopy after radiofrequency catheter ablation for atrial fibrillation: Documented higher risk of luminal esophageal damage with general anesthesia as compared with conscious sedation
    • 19808454 10.1161/CIRCEP.108.815266
    • Di Biase, L., Saenz, L. C., Burkhardt, D. J., Vacca, M., Elayi, C. S., Barrett, C. D., et al. (2009). Esophageal capsule endoscopy after radiofrequency catheter ablation for atrial fibrillation: documented higher risk of luminal esophageal damage with general anesthesia as compared with conscious sedation. Circulation. Arrhythmia and Electrophysiology, 2, 108-112.
    • (2009) Circulation. Arrhythmia and Electrophysiology , vol.2 , pp. 108-112
    • Di Biase, L.1    Saenz, L.C.2    Burkhardt, D.J.3    Vacca, M.4    Elayi, C.S.5    Barrett, C.D.6
  • 14
    • 24744434175 scopus 로고    scopus 로고
    • Anatomic relations between the esophagus and left atrium and relevance for ablation of atrial fibrillation
    • 16129790 10.1161/CIRCULATIONAHA.105.551291
    • Sanchez-Quintana, D., Cabrera, J. A., Climent, V., Farre, J., de Mendonca, M. C., & Ho, S. Y. (2005). Anatomic relations between the esophagus and left atrium and relevance for ablation of atrial fibrillation. Circulation, 112, 1400-1405.
    • (2005) Circulation , vol.112 , pp. 1400-1405
    • Sanchez-Quintana, D.1    Cabrera, J.A.2    Climent, V.3    Farre, J.4    De Mendonca, M.C.5    Ho, S.Y.6
  • 17
    • 79958816503 scopus 로고    scopus 로고
    • Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: Results of a pilot study
    • 21325208 10.1161/CIRCEP.110.960328
    • Leite, L. R., Santos, S. N., Maia, H., Henz, B. D., Giuseppin, F., Oliverira, A., et al. (2011). Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study. Circulation. Arrhythmia and Electrophysiology, 4(2), 149-156.
    • (2011) Circulation. Arrhythmia and Electrophysiology , vol.4 , Issue.2 , pp. 149-156
    • Leite, L.R.1    Santos, S.N.2    Maia, H.3    Henz, B.D.4    Giuseppin, F.5    Oliverira, A.6
  • 18
    • 79957706725 scopus 로고    scopus 로고
    • Prevalence and characteristics of asymptomatic excessive transmural injury after radiofrequency catheter ablation of atrial fibrillation
    • 21315839 10.1016/j.hrthm.2011.01.045
    • Yamasaki, H., Tada, H., Sekiguchi, Y., Igarashi, M., Arimoto, T., Machino, T., et al. (2011). Prevalence and characteristics of asymptomatic excessive transmural injury after radiofrequency catheter ablation of atrial fibrillation. Heart Rhythm, 8(6), 826-832.
    • (2011) Heart Rhythm , vol.8 , Issue.6 , pp. 826-832
    • Yamasaki, H.1    Tada, H.2    Sekiguchi, Y.3    Igarashi, M.4    Arimoto, T.5    MacHino, T.6
  • 19
    • 33644776087 scopus 로고    scopus 로고
    • Real-time monitoring of luminal esophageal temperature during left atrial radiofrequency catheter ablation for atrial fibrillation: Observations about esophageal heating during ablation at the pulmonary vein ostia and posterior left atrium
    • 16533254 10.1111/j.1540-8167.2005.00333.x
    • Perzanowski, C., Teplitsky, L., Hranitzky, P. M., & Bahnson, T. D. (2006). Real-time monitoring of luminal esophageal temperature during left atrial radiofrequency catheter ablation for atrial fibrillation: observations about esophageal heating during ablation at the pulmonary vein ostia and posterior left atrium. Journal of Cardiovascular Electrophysiology, 17(2), 166-170.
    • (2006) Journal of Cardiovascular Electrophysiology , vol.17 , Issue.2 , pp. 166-170
    • Perzanowski, C.1    Teplitsky, L.2    Hranitzky, P.M.3    Bahnson, T.D.4
  • 20
    • 77957345385 scopus 로고    scopus 로고
    • Computational method to predict esophageal temperature elevations during pulmonary vein isolation
    • 20546158 10.1111/j.1540-8159.2010.02804.x
    • Musat, D., Aziz, E. F., Koneru, J., Arshad, A., Kamath, G. S., Mittal, S., et al. (2010). Computational method to predict esophageal temperature elevations during pulmonary vein isolation. Pacing and Clinical Electrophysiology, 33(10), 1239-1248.
    • (2010) Pacing and Clinical Electrophysiology , vol.33 , Issue.10 , pp. 1239-1248
    • Musat, D.1    Aziz, E.F.2    Koneru, J.3    Arshad, A.4    Kamath, G.S.5    Mittal, S.6
  • 21
    • 70349308416 scopus 로고    scopus 로고
    • Canine model of esophageal injury and atrial-esophageal fistula after applications of forward-firing high-intensity focused ultrasound and side-firing unfocused ultrasound in the left atrium and inside the pulmonary vein
    • 19808443 10.1161/CIRCEP.108.807925
    • Yokoyama, K., Nakagawa, H., Seres, K. A., Jung, E., Merino, J., Zou, Y., et al. (2009). Canine model of esophageal injury and atrial-esophageal fistula after applications of forward-firing high-intensity focused ultrasound and side-firing unfocused ultrasound in the left atrium and inside the pulmonary vein. Circulation. Arrhythmia and Electrophysiology, 2, 41-49.
    • (2009) Circulation. Arrhythmia and Electrophysiology , vol.2 , pp. 41-49
    • Yokoyama, K.1    Nakagawa, H.2    Seres, K.A.3    Jung, E.4    Merino, J.5    Zou, Y.6
  • 22
    • 67549085521 scopus 로고    scopus 로고
    • Esophageal damage during radiofrequency ablation of atrial fibrillation: Impact of energy settings, lesion sets, and esophageal visualization
    • 19207781 10.1111/j.1540-8167.2008.01426.x 1:STN:280: DC%2BD1MvnvFSqug%3D%3D
    • Martinek, M., Bencsik, G., Aichinger, J., Hassanein, S., Schoefl, R., Kuchinka, P., et al. (2009). Esophageal damage during radiofrequency ablation of atrial fibrillation: impact of energy settings, lesion sets, and esophageal visualization. Journal of Cardiovascular Electrophysiology, 20(7), 726-733.
    • (2009) Journal of Cardiovascular Electrophysiology , vol.20 , Issue.7 , pp. 726-733
    • Martinek, M.1    Bencsik, G.2    Aichinger, J.3    Hassanein, S.4    Schoefl, R.5    Kuchinka, P.6
  • 23
    • 15544374097 scopus 로고    scopus 로고
    • Novel imaging techniques of the esophagus enhancing safety of left atrial ablation
    • 15817079 10.1046/j.1540-8167.2005.40560.x
    • Pollak, S. J., Monir, G., Chernoby, M. S., & Elenberger, C. D. (2005). Novel imaging techniques of the esophagus enhancing safety of left atrial ablation. Journal of Cardiovascular Electrophysiology, 16, 244-248.
    • (2005) Journal of Cardiovascular Electrophysiology , vol.16 , pp. 244-248
    • Pollak, S.J.1    Monir, G.2    Chernoby, M.S.3    Elenberger, C.D.4
  • 24
    • 58149117951 scopus 로고    scopus 로고
    • Safe and effective ablation of atrial fibrillation: Importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation
    • 18775045 10.1111/j.1540-8167.2008.01280.x
    • Kuwahara, T., Takahashi, A., Kobori, A., Miyazaki, S., Takahashi, Y., Takei, A., et al. (2009). Safe and effective ablation of atrial fibrillation: importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 20, 1-6.
    • (2009) Journal of Cardiovascular Electrophysiology , vol.20 , pp. 1-6
    • Kuwahara, T.1    Takahashi, A.2    Kobori, A.3    Miyazaki, S.4    Takahashi, Y.5    Takei, A.6
  • 25
    • 60749110393 scopus 로고    scopus 로고
    • Mechanical displacement of the esophagus in patients undergoing left atrial ablation of atrial fibrillation
    • 19251204 10.1016/j.hrthm.2008.12.010
    • Chugh, A., Rubenstein, J., Good, E., Ebinger, M., Jongnarangsin, K., Fortino, J., et al. (2009). Mechanical displacement of the esophagus in patients undergoing left atrial ablation of atrial fibrillation. Heart Rhythm, 6(3), 319-322.
    • (2009) Heart Rhythm , vol.6 , Issue.3 , pp. 319-322
    • Chugh, A.1    Rubenstein, J.2    Good, E.3    Ebinger, M.4    Jongnarangsin, K.5    Fortino, J.6
  • 28
    • 34249098038 scopus 로고    scopus 로고
    • Randomized comparison between open irrigation technology and intracardiac-echo-guided delivery for pulmonary vein antrum isolation: Procedural parameters, outcomes and the effect on esophageal injury
    • 17490437 10.1111/j.1540-8167.2007.00879.x
    • Marrouche, N. F., Guenther, J., Segerson, J. M., Daccarett, M., Rittger, H., Marschang, H., et al. (2007). Randomized comparison between open irrigation technology and intracardiac-echo-guided delivery for pulmonary vein antrum isolation: procedural parameters, outcomes and the effect on esophageal injury. Journal of Cardiovascular Electrophysiology, 18, 583-588.
    • (2007) Journal of Cardiovascular Electrophysiology , vol.18 , pp. 583-588
    • Marrouche, N.F.1    Guenther, J.2    Segerson, J.M.3    Daccarett, M.4    Rittger, H.5    Marschang, H.6
  • 29
    • 41949089867 scopus 로고    scopus 로고
    • Incidence of oesophageal wall injury post-pulmonary vein antrum isolation for treatment of patients with atrial fibrillation
    • 18256125 10.1093/europace/eun001
    • Schmidt, M., Nolker, G., Marschang, H., Gutleben, K. J., Schibgilla, V., Rittger, H., et al. (2008). Incidence of oesophageal wall injury post-pulmonary vein antrum isolation for treatment of patients with atrial fibrillation. Europace, 10(2), 205-209.
    • (2008) Europace , vol.10 , Issue.2 , pp. 205-209
    • Schmidt, M.1    Nolker, G.2    Marschang, H.3    Gutleben, K.J.4    Schibgilla, V.5    Rittger, H.6
  • 30
    • 77956227341 scopus 로고    scopus 로고
    • Identification of a high-risk population for esophageal injury during radiofrequency catheter ablation of atrial fibrillation: Procedural and anatomical considerations
    • 20188859 10.1016/j.hrthm.2010.02.027
    • Martinek, M., Meyer, C., Hassanein, S., Aichinger, J., Bencsik, G., Schoefl, R., et al. (2010). Identification of a high-risk population for esophageal injury during radiofrequency catheter ablation of atrial fibrillation: procedural and anatomical considerations. Heart Rhythm, 7(9), 1224-1230.
    • (2010) Heart Rhythm , vol.7 , Issue.9 , pp. 1224-1230
    • Martinek, M.1    Meyer, C.2    Hassanein, S.3    Aichinger, J.4    Bencsik, G.5    Schoefl, R.6
  • 31
    • 45149095735 scopus 로고    scopus 로고
    • Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: Comparison between 8 mm tip and open irrigation catheters
    • 18373604 10.1111/j.1540-8167.2008.01130.x
    • Cummings, J. E., Barrett, C. D., Litwak, K. N., DI Biase, L., Chowdhury, P., Oh, S., et al. (2008). Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: comparison between 8 mm tip and open irrigation catheters. Journal of Cardiovascular Electrophysiology, 19(6), 641-644.
    • (2008) Journal of Cardiovascular Electrophysiology , vol.19 , Issue.6 , pp. 641-644
    • Cummings, J.E.1    Barrett, C.D.2    Litwak, K.N.3    Di Biase, L.4    Chowdhury, P.5    Oh, S.6
  • 32
    • 0035783628 scopus 로고    scopus 로고
    • Esophageal injury during radiofrequency ablation for atrial fibrillation
    • 11726904 10.1067/mtc.2001.118041 1:STN:280:DC%2BD3MnotVGrsQ%3D%3D
    • Gillinov, A. M., Pettersson, G., & Rice, T. W. (2001). Esophageal injury during radiofrequency ablation for atrial fibrillation. The Journal of Thoracic and Cardiovascular Surgery, 122(6), 1239-1240.
    • (2001) The Journal of Thoracic and Cardiovascular Surgery , vol.122 , Issue.6 , pp. 1239-1240
    • Gillinov, A.M.1    Pettersson, G.2    Rice, T.W.3
  • 33
    • 0036587117 scopus 로고    scopus 로고
    • Curative treatment of atrial fibrillation with intraoperative radiofrequency ablation: Short-term and midterm results
    • 12019377 10.1067/mtc.2002.120730
    • Mohr, F. W., Fabricius, A. M., Falk, V., Autschbach, R., Doll, N., Von Oppell, U., et al. (2002). Curative treatment of atrial fibrillation with intraoperative radiofrequency ablation: short-term and midterm results. The Journal of Thoracic and Cardiovascular Surgery, 123(5), 919-927.
    • (2002) The Journal of Thoracic and Cardiovascular Surgery , vol.123 , Issue.5 , pp. 919-927
    • Mohr, F.W.1    Fabricius, A.M.2    Falk, V.3    Autschbach, R.4    Doll, N.5    Von Oppell, U.6
  • 34
    • 0037662135 scopus 로고    scopus 로고
    • A fatal complication due to radiofrequency ablation for atrial fibrillation: Atrio-esophageal fistula
    • 12842562 10.1016/S0003-4975(03)00006-7
    • Sonmez, B., Demirsoy, E., Yagan, N., Unal, M., Arbatli, H., Sener, D., et al. (2003). A fatal complication due to radiofrequency ablation for atrial fibrillation: atrio-esophageal fistula. The Annals of Thoracic Surgery, 76(1), 281-283.
    • (2003) The Annals of Thoracic Surgery , vol.76 , Issue.1 , pp. 281-283
    • Sonmez, B.1    Demirsoy, E.2    Yagan, N.3    Unal, M.4    Arbatli, H.5    Sener, D.6
  • 36
    • 23744437914 scopus 로고    scopus 로고
    • What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis
    • 16088072 10.1088/0967-3334/26/5/020
    • Berjano, E. J., & Hornero, F. (2005). What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis. Physiological Measurement, 26, 837-848.
    • (2005) Physiological Measurement , vol.26 , pp. 837-848
    • Berjano, E.J.1    Hornero, F.2
  • 38
    • 77951948055 scopus 로고    scopus 로고
    • Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote navigation system
    • 20233761 10.1093/europace/euq061
    • Rillig, A., Meyerfeldt, U., Birkmeyer, R., Wiest, S., Sauer, B. M., Staritz, M., et al. (2010). Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote navigation system. Europace, 12, 655-661.
    • (2010) Europace , vol.12 , pp. 655-661
    • Rillig, A.1    Meyerfeldt, U.2    Birkmeyer, R.3    Wiest, S.4    Sauer, B.M.5    Staritz, M.6
  • 39
    • 8544236990 scopus 로고    scopus 로고
    • Analysis of catheter-tip (8-mm) and actual tissue temperatures achieved during radiofrequency ablation at the orifice of the pulmonary vein
    • 15505085 10.1161/01.CIR.0000146905.19945.99
    • Bunch, T. J., Bruce, G. K., Johnson, S. B., Sarabanda, A., Milton, M. A., & Packer, D. L. (2004). Analysis of catheter-tip (8-mm) and actual tissue temperatures achieved during radiofrequency ablation at the orifice of the pulmonary vein. Circulation, 110(19), 2988-2995.
    • (2004) Circulation , vol.110 , Issue.19 , pp. 2988-2995
    • Bunch, T.J.1    Bruce, G.K.2    Johnson, S.B.3    Sarabanda, A.4    Milton, M.A.5    Packer, D.L.6
  • 40
    • 82455194858 scopus 로고    scopus 로고
    • Luminal esophageal temperature rise and esophageal lesion formation following remote-controlled magnetic pulmonary vein isolation
    • 21802392 10.1016/j.hrthm.2011.07.031
    • Konstantinidou, M., Wissner, E., Chun, J. K., Koektuerk, B., Metzner, A., Tilz, R. R., et al. (2011). Luminal esophageal temperature rise and esophageal lesion formation following remote-controlled magnetic pulmonary vein isolation. Heart Rhythm, 8(12), 1875-1880.
    • (2011) Heart Rhythm , vol.8 , Issue.12 , pp. 1875-1880
    • Konstantinidou, M.1    Wissner, E.2    Chun, J.K.3    Koektuerk, B.4    Metzner, A.5    Tilz, R.R.6
  • 41
    • 77958124442 scopus 로고    scopus 로고
    • Limiting esophageal temperature in radiofrequency ablation of left atrial tachyarrhythmias results in low incidence of thermal esophageal lesions
    • 20977747 10.1186/1471-2261-10-52
    • Sause, A., Tutdibi, O., Pomsel, K., Dinh, W., Füth, R., Lankisch, M., et al. (2010). Limiting esophageal temperature in radiofrequency ablation of left atrial tachyarrhythmias results in low incidence of thermal esophageal lesions. BMC Cardiovascular Disorders, 10, 52.
    • (2010) BMC Cardiovascular Disorders , vol.10 , pp. 52
    • Sause, A.1    Tutdibi, O.2    Pomsel, K.3    Dinh, W.4    Füth, R.5    Lankisch, M.6
  • 42
    • 79952512982 scopus 로고    scopus 로고
    • Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation
    • 20958829 10.1111/j.1540-8167.2010.01916.x
    • Deneke, T., Bunz, K., Bastian, A., Pasler, M., Anders, H., Lehmann, R., et al. (2011). Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation. Journal of Cardiovascular Electrophysiology, 22(3), 255-261.
    • (2011) Journal of Cardiovascular Electrophysiology , vol.22 , Issue.3 , pp. 255-261
    • Deneke, T.1    Bunz, K.2    Bastian, A.3    Pasler, M.4    Anders, H.5    Lehmann, R.6
  • 43
    • 79952509640 scopus 로고    scopus 로고
    • The esophageal temperature probe: Helpful monitoring device or inadvertent amplifier of risk?
    • 20958839 10.1111/j.1540-8167.2010.01936.x
    • Musat, D., & Mittal, S. (2011). The esophageal temperature probe: helpful monitoring device or inadvertent amplifier of risk? Journal of Cardiovascular Electrophysiology, 22(3), 262-264.
    • (2011) Journal of Cardiovascular Electrophysiology , vol.22 , Issue.3 , pp. 262-264
    • Musat, D.1    Mittal, S.2
  • 44
    • 77949275782 scopus 로고    scopus 로고
    • Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias
    • 19888201 10.1038/ajg.2009.625
    • Halm, U., Gaspar, T., Zachaus, M., Sack, S., Arya, A., Piorkowski, C., et al. (2010). Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias. American Journal of Gastroenterology, 105, 551-556.
    • (2010) American Journal of Gastroenterology , vol.105 , pp. 551-556
    • Halm, U.1    Gaspar, T.2    Zachaus, M.3    Sack, S.4    Arya, A.5    Piorkowski, C.6
  • 45
    • 59749099384 scopus 로고    scopus 로고
    • Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter
    • 19084796 10.1016/j.hrthm.2008.08.037
    • Boersma, L. V., Wijffels, M. C., Oral, H., Wever, E. F., & Morady, F. (2008). Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter. Heart Rhythm, 5, 1635-1642.
    • (2008) Heart Rhythm , vol.5 , pp. 1635-1642
    • Boersma, L.V.1    Wijffels, M.C.2    Oral, H.3    Wever, E.F.4    Morady, F.5
  • 46
    • 77950246414 scopus 로고    scopus 로고
    • Results of short-term and long-term pulmonary vein isolation for paroxysmal atrial fibrillation using duty-cycled bipolar and unipolar radiofrequency energy
    • 19909386 10.1111/j.1540-8167.2009.01640.x
    • Wieczorek, M., Hoeltgen, R., Akin, E., Salili, A. R., Oral, H., & Morady, F. (2010). Results of short-term and long-term pulmonary vein isolation for paroxysmal atrial fibrillation using duty-cycled bipolar and unipolar radiofrequency energy. Journal of Cardiovascular Electrophysiology, 21, 399-405.
    • (2010) Journal of Cardiovascular Electrophysiology , vol.21 , pp. 399-405
    • Wieczorek, M.1    Hoeltgen, R.2    Akin, E.3    Salili, A.R.4    Oral, H.5    Morady, F.6
  • 47
    • 77950367473 scopus 로고    scopus 로고
    • Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: First clinical results
    • 19937098 10.1007/s10840-009-9446-z
    • Wieczorek, M., Hoeltgen, R., Brueck, M., Bandorski, D., Akin, E., & Salili, A. R. (2010). Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: First clinical results. Journal of Interventional Cardiac Electrophysiology, 27, 23-31.
    • (2010) Journal of Interventional Cardiac Electrophysiology , vol.27 , pp. 23-31
    • Wieczorek, M.1    Hoeltgen, R.2    Brueck, M.3    Bandorski, D.4    Akin, E.5    Salili, A.R.6
  • 48
    • 70350774373 scopus 로고    scopus 로고
    • Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator
    • 19493155 10.1111/j.1540-8167.2009.01501.x
    • Fredersdorf, S., Weber, S., Jilek, C., Heinicke, N., VonBarry, C., Jungbauer, C., et al. (2009). Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator. Journal of Cardiovascular Electrophysiology, 20, 1097-1101.
    • (2009) Journal of Cardiovascular Electrophysiology , vol.20 , pp. 1097-1101
    • Fredersdorf, S.1    Weber, S.2    Jilek, C.3    Heinicke, N.4    Vonbarry, C.5    Jungbauer, C.6
  • 49
    • 26244438356 scopus 로고    scopus 로고
    • A cooled intraesophageal balloon to prevent thermal injury during endocardial surgical radiofrequency ablation of the left atrium: A finite element study
    • 16204868 10.1088/0031-9155/50/20/N03
    • Berjano, E. J., & Hornero, F. (2005). A cooled intraesophageal balloon to prevent thermal injury during endocardial surgical radiofrequency ablation of the left atrium: a finite element study. Physics in Medicine and Biology, 50, N269-N279.
    • (2005) Physics in Medicine and Biology , vol.50
    • Berjano, E.J.1    Hornero, F.2
  • 50
    • 33846361056 scopus 로고    scopus 로고
    • Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: A pilot study
    • 17239114 10.1111/j.1540-8167.2006.00693.x
    • Tsuchiya, T., Ashikaga, K., Nakagawa, S., Hayashida, K., & Kugimiya, H. (2007). Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: a pilot study. Journal of Cardiovascular Electrophysiology, 18, 145-150.
    • (2007) Journal of Cardiovascular Electrophysiology , vol.18 , pp. 145-150
    • Tsuchiya, T.1    Ashikaga, K.2    Nakagawa, S.3    Hayashida, K.4    Kugimiya, H.5
  • 51
    • 76849103314 scopus 로고    scopus 로고
    • Acute development of gastroesophageal reflux after radiofrequency catheter ablation of atrial fibrillation
    • 19716773 10.1016/j.hrthm.2009.06.022
    • Martinek, M., Hassanein, S., Bencsik, G., Aichinger, J., Schoefl, R., Bachl, A., et al. (2009). Acute development of gastroesophageal reflux after radiofrequency catheter ablation of atrial fibrillation. Heart Rhythm, 6(10), 1457-1462.
    • (2009) Heart Rhythm , vol.6 , Issue.10 , pp. 1457-1462
    • Martinek, M.1    Hassanein, S.2    Bencsik, G.3    Aichinger, J.4    Schoefl, R.5    Bachl, A.6
  • 52
    • 76849102931 scopus 로고    scopus 로고
    • Gastroesophageal reflux and atrial-esophageal fistula
    • 19968925 10.1016/j.hrthm.2009.07.023
    • Stevenson, W. G., & Saltzman, J. R. (2009). Gastroesophageal reflux and atrial-esophageal fistula. Heart Rhythm, 6(10), 1463-1464.
    • (2009) Heart Rhythm , vol.6 , Issue.10 , pp. 1463-1464
    • Stevenson, W.G.1    Saltzman, J.R.2
  • 53
    • 82455175259 scopus 로고    scopus 로고
    • Severity of esophageal injury predicts time to healing after radiofrequency catheter ablation for atrial fibrillation
    • 21782773 10.1016/j.hrthm.2011.07.022
    • Contreras-Valdes, F. M., Heist, E. K., Danik, S. B., Barrett, C. D., Blendea, D., Brugge, W. R., et al. (2011). Severity of esophageal injury predicts time to healing after radiofrequency catheter ablation for atrial fibrillation. Heart Rhythm, 8(12), 1862-1868.
    • (2011) Heart Rhythm , vol.8 , Issue.12 , pp. 1862-1868
    • Contreras-Valdes, F.M.1    Heist, E.K.2    Danik, S.B.3    Barrett, C.D.4    Blendea, D.5    Brugge, W.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.