메뉴 건너뛰기




Volumn 19, Issue 6, 2008, Pages 641-644

Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: Comparison between 8 mm tip and open irrigation catheters

Author keywords

Atrioesophageal fistula; Catheter ablation; Complications; Esophagus; Pulmonary vein isolation

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; CATHETER; CATHETER ABLATION; COMPARATIVE STUDY; CONTROLLED STUDY; DOG; ESOPHAGUS; HEART LEFT ATRIUM; NONHUMAN; OPEN IRRIGATED TIP CATHETER; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; TEMPERATURE MEASUREMENT;

EID: 45149095735     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2008.01130.x     Document Type: Article
Times cited : (61)

References (14)
  • 2
    • 15544368055 scopus 로고    scopus 로고
    • Left atrial-esophageal fistula complicating radiofrequency catheter ablation of atrial fibrillation
    • Sosa E, Scanavacca M: Left atrial-esophageal fistula complicating radiofrequency catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 2005 16: 249 250.
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 249-250
    • Sosa, E.1    Scanavacca, M.2
  • 5
    • 0344493893 scopus 로고    scopus 로고
    • Esophageal perforation during left atrial radiofrequency ablation: Is the risk too high?
    • author reply 1662.
    • Gillinov AM, Pettersson G, Rice TW: Esophageal perforation during left atrial radiofrequency ablation: Is the risk too high? J Thorac Cardiovasc Surg 2003 126: 1661 1662 author reply 1662.
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 1661-1662
    • Gillinov, A.M.1    Pettersson, G.2    Tw, R.3
  • 6
    • 0035783628 scopus 로고    scopus 로고
    • Esophageal injury during radiofrequency ablation for atrial fibrillation
    • Gillinov AM, Pettersson G, Rice TW: Esophageal injury during radiofrequency ablation for atrial fibrillation. J Thorac Cardiovasc Surg 2001 122: 1239 1240.
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 1239-1240
    • Gillinov, A.M.1    Pettersson, G.2    Rice, T.W.3
  • 7
    • 33750042225 scopus 로고    scopus 로고
    • Rapid detection and successful treatment of esophageal perforation after radiofrequency ablation of atrial fibrillation: Lessons from five cases
    • Dagres N, Kottkamp H, Piorkowski C, Doll N, Mohr F, Horlitz M, Kremastinos DTh, Hindricks G: Rapid detection and successful treatment of esophageal perforation after radiofrequency ablation of atrial fibrillation: Lessons from five cases. J Cardiovasc Electrophysiol 2006 17: 1213 1215.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1213-1215
    • Dagres, N.1    Kottkamp, H.2    Piorkowski, C.3    Doll, N.4    Mohr, F.5    Horlitz, M.6    Dth, K.7    Hindricks, G.8
  • 9
    • 0037636441 scopus 로고    scopus 로고
    • A tailored anatomical approach to prevent complications during left atrial ablation
    • Benussi S, Nascimbene S, Calvi S, Alfieri O: A tailored anatomical approach to prevent complications during left atrial ablation. Ann Thorac Surg 2003 75: 1979 1981.
    • (2003) Ann Thorac Surg , vol.75 , pp. 1979-1981
    • Benussi, S.1    Nascimbene, S.2    Calvi, S.3    Alfieri, O.4
  • 10
    • 33846361056 scopus 로고    scopus 로고
    • Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: A pilot study
    • Tsuchiya T, Ashikaga K, Nakagawa S, Hayashida K, Kugimiya H: Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: A pilot study. J Cardiovasc Electrophysiol 2007 18: 145 150.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 145-150
    • Tsuchiya, T.1    Ashikaga, K.2    Nakagawa, S.3    Hayashida, K.4    Kugimiya, H.5
  • 11
    • 10844249881 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Esophageal migration during left atrial catheter ablation for atrial fibrillation
    • Han J, Good E, Morady F, Oral H: Images in cardiovascular medicine. Esophageal migration during left atrial catheter ablation for atrial fibrillation. Circulation 2004 110: e528.
    • (2004) Circulation , vol.110
    • Han, J.1    Good, E.2    Morady, F.3    Oral, H.4
  • 14
    • 33645297948 scopus 로고    scopus 로고
    • Esophageal temperature during radiofrequency-catheter ablation of left atrium: A three-dimensional computer modeling study
    • Hornero F, Berjano EJ: Esophageal temperature during radiofrequency- catheter ablation of left atrium: A three-dimensional computer modeling study. J Cardiovasc Electrophysiol 2006 17: 405 410.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 405-410
    • Hornero, F.1    Berjano, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.