1
-
-
0027534580
-
Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter
-
Cosio FG, Lopez-Gil M, Goicolea A, Arribas F, Barroso JL. Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter. Am J Cardiol 1993;71:705-709.
-
(1993)
Am J Cardiol
, vol.71
, pp. 705-709
-
-
Cosio, F.G.1
Lopez-Gil, M.2
Goicolea, A.3
Arribas, F.4
Barroso, J.L.5
-
2
-
-
9444295300
-
Role of the tricuspid annulus and the Eustachian valve/ridge on atrial flutter. Relevance to catheter ablation of the septal isthmus and a new technique for rapid identificat-ion of ablation success
-
Nakagawa H, Lazzara R, Khastgir T, Beckman KJ, McClelland JH, Imai S, Pitha JV, Becker AE, Arruda M, Gonzalez MD, et al. Role of the tricuspid annulus and the Eustachian valve/ridge on atrial flutter. Relevance to catheter ablation of the septal isthmus and a new technique for rapid identificat-ion of ablation success. Circulation 1996;94:407-424.
-
(1996)
Circulation
, vol.94
, pp. 407-424
-
-
Nakagawa, H.1
Lazzara, R.2
Khastgir, T.3
Beckman, K.J.4
McClelland, J.H.5
Imai, S.6
Pitha, J.V.7
Becker, A.E.8
Arruda, M.9
Gonzalez, M.D.10
-
3
-
-
0029097778
-
Relation of pace mapping QRS configuration and conduction delay to ventricular tachycardia reentry circuits in human infarct scars
-
Stevenson WG, Sager PT, Natterson PD, Saxon LA, Middlekauff HR, Wiener I. Relation of pace mapping QRS configuration and conduction delay to ventricular tachycardia reentry circuits in human infarct scars. J Am Coll Cardiol 1995;26:481-488.
-
(1995)
J Am Coll Cardiol
, vol.26
, pp. 481-488
-
-
Stevenson, W.G.1
Sager, P.T.2
Natterson, P.D.3
Saxon, L.A.4
Middlekauff, H.R.5
Wiener, I.6
-
4
-
-
2342614876
-
Long-term outcome of catheter ablation for postinfarct ventricular tachycardia
-
Wilber DJ, Burke MC, Kall JG, Verdino RJ, Kopp DE. Long-term outcome of catheter ablation for postinfarct ventricular tachycardia. [Abstract]. Circulation 1997;96:I-318.
-
(1997)
Circulation
, vol.96
-
-
Wilber, D.J.1
Burke, M.C.2
Kall, J.G.3
Verdino, R.J.4
Kopp, D.E.5
-
5
-
-
0032127750
-
Bipolar radiofrequency catheter ablation creates confluent lesions at larger interelectrode spacing than does unipolar ablation from two electrodes in the porcine heart
-
Anfinsen OG, Kongsgaard E, Foerster A, Amlie JP, Aass H. Bipolar radiofrequency catheter ablation creates confluent lesions at larger interelectrode spacing than does unipolar ablation from two electrodes in the porcine heart. Eur Heart J 1998;19:1075-1084.
-
(1998)
Eur Heart J
, vol.19
, pp. 1075-1084
-
-
Anfinsen, O.G.1
Kongsgaard, E.2
Foerster, A.3
Amlie, J.P.4
Aass, H.5
-
6
-
-
0027295050
-
Temperature-guided radiofrequency catheter ablation with very large distal electrodes
-
Langberg JJ, Gallagher M, Strickberger SA, Amirana O. Temperature-guided radiofrequency catheter ablation with very large distal electrodes. Circulation 1993;88:245-249.
-
(1993)
Circulation
, vol.88
, pp. 245-249
-
-
Langberg, J.J.1
Gallagher, M.2
Strickberger, S.A.3
Amirana, O.4
-
7
-
-
0025095887
-
Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo
-
Langberg JJ, Lee MA, Chin MC, Rosenqvist M. Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo. PACE 1990;13:1242-1248.
-
(1990)
PACE
, vol.13
, pp. 1242-1248
-
-
Langberg, J.J.1
Lee, M.A.2
Chin, M.C.3
Rosenqvist, M.4
-
8
-
-
0025293526
-
Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model
-
Haines DE, Watson DD, Verow AF. Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model. Circ Res 1990;67:124-129.
-
(1990)
Circ Res
, vol.67
, pp. 124-129
-
-
Haines, D.E.1
Watson, D.D.2
Verow, A.F.3
-
9
-
-
0029000109
-
Use of the saline infusion electrode catheter for improved energy delivery and increased lesion size in radiofrequency catheter ablation
-
Mittleman RS, Huang SK, de Guzman WT, Cuenoud H, Wagshal AB, Pires LA. Use of the saline infusion electrode catheter for improved energy delivery and increased lesion size in radiofrequency catheter ablation. PACE 1995;18:1022-1027.
-
(1995)
PACE
, vol.18
, pp. 1022-1027
-
-
Mittleman, R.S.1
Huang, S.K.2
De Guzman, W.T.3
Cuenoud, H.4
Wagshal, A.B.5
Pires, L.A.6
-
10
-
-
0029559129
-
Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart
-
Ruffy R, Imran MA, Santel DJ, Wharton JM. Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart. J Cardiovasc Electrophysiol 1995;6:1089-1096.
-
(1995)
J Cardiovasc Electrophysiol
, vol.6
, pp. 1089-1096
-
-
Ruffy, R.1
Imran, M.A.2
Santel, D.J.3
Wharton, J.M.4
-
11
-
-
0028942447
-
Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
-
Nakagawa H, Yamanashi WS, Pitha JV, Arruda M, Wang X, Ohtomo K, Beckman KJ, McClelland JH, Lazzara R, Jackman WM. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995;91: 2264-2273.
-
(1995)
Circulation
, vol.91
, pp. 2264-2273
-
-
Nakagawa, H.1
Yamanashi, W.S.2
Pitha, J.V.3
Arruda, M.4
Wang, X.5
Ohtomo, K.6
Beckman, K.J.7
McClelland, J.H.8
Lazzara, R.9
Jackman, W.M.10
-
12
-
-
0343200962
-
Is 8 mm really more effective than 4 mm tip-ablation catheter for ablation of atrial flutter?
-
Chen SA, Tai CT, Yu WC, Chen YJ, Ding YA, Chang MS. Is 8 mm really more effective than 4 mm tip-ablation catheter for ablation of atrial flutter? [Abstract]. Circulation 1998;98:I-19.
-
(1998)
Circulation
, vol.98
-
-
Chen, S.A.1
Tai, C.T.2
Yu, W.C.3
Chen, Y.J.4
Ding, Y.A.5
Chang, M.S.6
-
13
-
-
0032151268
-
Effect of catheter tip length and position on lesion volume in temperature controlled RF ablation in canine tricuspid valve annulus
-
Mehdirad A, Gaiser J, Baker P, West S, Lehmkuhl L, Yong P, Meimer J, Nelson S. Effect of catheter tip length and position on lesion volume in temperature controlled RF ablation in canine tricuspid valve annulus. J Intervent Cardiac Electrophysiol 1998;2:279-284.
-
(1998)
J Intervent Cardiac Electrophysiol
, vol.2
, pp. 279-284
-
-
Mehdirad, A.1
Gaiser, J.2
Baker, P.3
West, S.4
Lehmkuhl, L.5
Yong, P.6
Meimer, J.7
Nelson, S.8
-
14
-
-
0031933716
-
Radiofrequency current ablation of porcine right atrium: Increased lesion size within bipolar two catheter technique compared to unipolar application in vitro and in vivo
-
Anfinsen OG, Kongsgaard E, Foerster A, Aass H, Amlie JP. Radiofrequency current ablation of porcine right atrium: Increased lesion size within bipolar two catheter technique compared to unipolar application in vitro and in vivo. PACE 1998;21:69-78.
-
(1998)
PACE
, vol.21
, pp. 69-78
-
-
Anfinsen, O.G.1
Kongsgaard, E.2
Foerster, A.3
Aass, H.4
Amlie, J.P.5
-
15
-
-
0010455143
-
Factors influencing transcatheter radiofrequency ablation of the myocardium
-
Hoyt RH, Huang SK, Jordan N, Marcus F. Factors influencing transcatheter radiofrequency ablation of the myocardium. [Abstract]. Circulation 1987;72:III-473.
-
(1987)
Circulation
, vol.72
-
-
Hoyt, R.H.1
Huang, S.K.2
Jordan, N.3
Marcus, F.4
-
16
-
-
0024364286
-
Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and supervised canine right ventricular free wall
-
Haines DE, Watson DD. Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and supervised canine right ventricular free wall. PACE 1989;12:962-976.
-
(1989)
PACE
, vol.12
, pp. 962-976
-
-
Haines, D.E.1
Watson, D.D.2
-
17
-
-
0008551190
-
Transmural ablation of the atrial tissue using an irrigated tip electrode with monitoring the electrogram at the ablation site
-
Satake S, Okishige K, Azegami K, Sasano T. Transmural ablation of the atrial tissue using an irrigated tip electrode with monitoring the electrogram at the ablation site. [Abstract]. Circulation 1997;96:I-576.
-
(1997)
Circulation
, vol.96
-
-
Satake, S.1
Okishige, K.2
Azegami, K.3
Sasano, T.4
-
18
-
-
24544435155
-
Impact of ablation location on impedence pop occurrence with irrigated tip energy delivery in dogs
-
Johnson S. Impact of ablation location on impedence pop occurrence with irrigated tip energy delivery in dogs. [Abstract]. Circulation 1997;96:I-576.
-
(1997)
Circulation
, vol.96
-
-
Johnson, S.1
-
19
-
-
0028025688
-
Power and temperature guided radiofrequency catheter ablation of the right atrium in pigs
-
Kongsgaard E, Foerster A, Aass H, Madsen S, Amlie JP. Power and temperature guided radiofrequency catheter ablation of the right atrium in pigs. PACE 1994;17:1610-1620.
-
(1994)
PACE
, vol.17
, pp. 1610-1620
-
-
Kongsgaard, E.1
Foerster, A.2
Aass, H.3
Madsen, S.4
Amlie, J.P.5
-
20
-
-
0027316390
-
The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring
-
Haines DE. The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring. PACE 1993;16:586-591.
-
(1993)
PACE
, vol.16
, pp. 586-591
-
-
Haines, D.E.1
-
21
-
-
0030988916
-
Coronary artery involvement early and late after radiofrequency current application in young pigs
-
Paul T, Bokenkamp R, Mahnert B, Trappe HJ. Coronary artery involvement early and late after radiofrequency current application in young pigs. Am Heart J 1997;133:436-440.
-
(1997)
Am Heart J
, vol.133
, pp. 436-440
-
-
Paul, T.1
Bokenkamp, R.2
Mahnert, B.3
Trappe, H.J.4
-
22
-
-
0027223222
-
Effect on coronary artery anatomy of radiofrequency catheter ablation of atrial insertion sites of accessory pathways
-
Solomon AJ, Tracy CM, Swartz JF, Reagan KM, Karasik PE, Fletcher RD. Effect on coronary artery anatomy of radiofrequency catheter ablation of atrial insertion sites of accessory pathways. J Am Coll Cardiol 1993;21:1440-1444.
-
(1993)
J Am Coll Cardiol
, vol.21
, pp. 1440-1444
-
-
Solomon, A.J.1
Tracy, C.M.2
Swartz, J.F.3
Reagan, K.M.4
Karasik, P.E.5
Fletcher, R.D.6
-
23
-
-
0027457373
-
Evaluation of possible long-term adverse consequences of radiofrequency ablation of accessory pathways
-
Strickberger SA, Okishige K, Meyerovitz M, Shea J, Friedman PL. Evaluation of possible long-term adverse consequences of radiofrequency ablation of accessory pathways. Am J Cardiol 1993;71:473-475.
-
(1993)
Am J Cardiol
, vol.71
, pp. 473-475
-
-
Strickberger, S.A.1
Okishige, K.2
Meyerovitz, M.3
Shea, J.4
Friedman, P.L.5
-
24
-
-
0026582617
-
Curative percutaneous catheter ablation using radiofrequency energy for accessory pathways in all locations: Results in 100 consecutive patients
-
Lesh MD, Van Hare GF, Schamp DJ, Chien W, Lee MA, Griffin JC, Langberg JJ, Cohen TJ, Lurie KG, Scheinman MM. Curative percutaneous catheter ablation using radiofrequency energy for accessory pathways in all locations: results in 100 consecutive patients. J Am Coll Cardiol 1992;19:1303-1309.
-
(1992)
J Am Coll Cardiol
, vol.19
, pp. 1303-1309
-
-
Lesh, M.D.1
Van Hare, G.F.2
Schamp, D.J.3
Chien, W.4
Lee, M.A.5
Griffin, J.C.6
Langberg, J.J.7
Cohen, T.J.8
Lurie, K.G.9
Scheinman, M.M.10
-
25
-
-
0029012441
-
Left main coronary thrombosis after radiofrequency ablation: Successful treatment with percutaneous transluminal angioplasty
-
Hope EJ, Haigney MC, Calkins H, Resar JR. Left main coronary thrombosis after radiofrequency ablation: Successful treatment with percutaneous transluminal angioplasty. Am Heart J 1995;129:1217-1219.
-
(1995)
Am Heart J
, vol.129
, pp. 1217-1219
-
-
Hope, E.J.1
Haigney, M.C.2
Calkins, H.3
Resar, J.R.4
-
26
-
-
0030850757
-
Chronic left main coronary artery occlusion: A complication of radiofrequency ablation of idiopathic left ventricular tachycardia
-
Pons M, Beck L, Leclercq F, Fernere M, Albat B, Davy JM. Chronic left main coronary artery occlusion: A complication of radiofrequency ablation of idiopathic left ventricular tachycardia. PACE 1997;20:1874-1876.
-
(1997)
PACE
, vol.20
, pp. 1874-1876
-
-
Pons, M.1
Beck, L.2
Leclercq, F.3
Fernere, M.4
Albat, B.5
Davy, J.M.6
-
27
-
-
0029124834
-
The risk of atrial fibrillation following radiofrequency catheter ablation of atrial flutter
-
Philippon F, Plumb VJ, Epstein AE, Kay GN. The risk of atrial fibrillation following radiofrequency catheter ablation of atrial flutter. Circulation 1995;92:430-435.
-
(1995)
Circulation
, vol.92
, pp. 430-435
-
-
Philippon, F.1
Plumb, V.J.2
Epstein, A.E.3
Kay, G.N.4
-
28
-
-
0028903876
-
Radiofrequency catheter ablation of common atrial flutter in 80 patients
-
Fischer B, Haissaguerre M, Garrigues S, Poquet F, Gencel L, Clementy J, Marcus FI. Radiofrequency catheter ablation of common atrial flutter in 80 patients. J Am Coll Cardiol 1995;25:1365-1372.
-
(1995)
J Am Coll Cardiol
, vol.25
, pp. 1365-1372
-
-
Fischer, B.1
Haissaguerre, M.2
Garrigues, S.3
Poquet, F.4
Gencel, L.5
Clementy, J.6
Marcus, F.I.7
-
29
-
-
0030045654
-
Electrophysiological effects of catheter ablation of inferior vena cava-tricuspid annulus isthmus in common atrial flutter
-
Cauchemez B, Haissaguerre M, Fischer B, Thomas O, Clementy J, Coumel P. Electrophysiological effects of catheter ablation of inferior vena cava-tricuspid annulus isthmus in common atrial flutter. Circulation 1996;93:284-294.
-
(1996)
Circulation
, vol.93
, pp. 284-294
-
-
Cauchemez, B.1
Haissaguerre, M.2
Fischer, B.3
Thomas, O.4
Clementy, J.5
Coumel, P.6
-
30
-
-
0029867927
-
Radiofrequency catheter ablation of common atrial flutter: Comparison of electrophysiologically guided focal ablation technique and linear ablation technique
-
Chen SA, Chiang CE, Wu TJ, Tai CT, Lee SH, Cheng CC, Chiou CW, Ueng KC, Wen ZC, Chang MS. Radiofrequency catheter ablation of common atrial flutter: Comparison of electrophysiologically guided focal ablation technique and linear ablation technique. J Am Coll Cardiol 1996;27: 860-868.
-
(1996)
J Am Coll Cardiol
, vol.27
, pp. 860-868
-
-
Chen, S.A.1
Chiang, C.E.2
Wu, T.J.3
Tai, C.T.4
Lee, S.H.5
Cheng, C.C.6
Chiou, C.W.7
Ueng, K.C.8
Wen, Z.C.9
Chang, M.S.10
-
31
-
-
0028280525
-
Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms
-
Lesh MD, Van Hare GF, Epstein LM, Fitzpatrick AP, Scheinman MM, Lee RJ, Kwasman MA, Grogin HR, Griffin JC. Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms. Circulation 1994;89:1074-1089.
-
(1994)
Circulation
, vol.89
, pp. 1074-1089
-
-
Lesh, M.D.1
Van Hare, G.F.2
Epstein, L.M.3
Fitzpatrick, A.P.4
Scheinman, M.M.5
Lee, R.J.6
Kwasman, M.A.7
Grogin, H.R.8
Griffin, J.C.9
-
32
-
-
0029101339
-
Linear ablation of the isthmus between the inferior vena cava and tricuspid annulus for the treatment of atrial flutter. A study in the canine atrial flutter model
-
Tabuchi T, Okumura K, Matsunaga T, Tsunoda R, Jougasaki M, Yasue H. Linear ablation of the isthmus between the inferior vena cava and tricuspid annulus for the treatment of atrial flutter. A study in the canine atrial flutter model. Circulation 1995;92:1312-1319.
-
(1995)
Circulation
, vol.92
, pp. 1312-1319
-
-
Tabuchi, T.1
Okumura, K.2
Matsunaga, T.3
Tsunoda, R.4
Jougasaki, M.5
Yasue, H.6
-
33
-
-
0030953697
-
Temperature guided radiofrequency catheter ablation of myocardium: Comparison of catheter tip and tissue temperatures in vitro
-
Kongsgaard E, Steen T, Jensen O, Aass H, Amlie JP. Temperature guided radiofrequency catheter ablation of myocardium: Comparison of catheter tip and tissue temperatures in vitro. PACE 1997;20:1252-1260.
-
(1997)
PACE
, vol.20
, pp. 1252-1260
-
-
Kongsgaard, E.1
Steen, T.2
Jensen, O.3
Aass, H.4
Amlie, J.P.5
-
34
-
-
0029074563
-
Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: An examination of electrode thermistor positioning for measurement accuracy
-
McRury ID, Whayne JG, Haines DE. Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: An examination of electrode thermistor positioning for measurement accuracy. J Cardiovasc Electrophysiol 1995;6:268-278.
-
(1995)
J Cardiovasc Electrophysiol
, vol.6
, pp. 268-278
-
-
McRury, I.D.1
Whayne, J.G.2
Haines, D.E.3
-
35
-
-
0030425347
-
Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor
-
Anfinsen OG, Kongsgaard E, Aass H, Amlie JP. Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor. Eur JCPE 1996;6:195-203.
-
(1996)
Eur JCPE
, vol.6
, pp. 195-203
-
-
Anfinsen, O.G.1
Kongsgaard, E.2
Aass, H.3
Amlie, J.P.4
|