메뉴 건너뛰기




Volumn 68, Issue 3, 2012, Pages 932-946

ARFI-prepared MRgHIFU in liver: Simultaneous mapping of ARFI-displacement and temperature elevation, using a fast GRE-EPI sequence

Author keywords

focused ultrasound; liver; radiation force; safety; targeting; thermometry

Indexed keywords

ACCIDENT PREVENTION; ACOUSTIC WAVE PROPAGATION; IMAGE RESOLUTION; LIVER; THERMOMETERS;

EID: 84865530295     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.23309     Document Type: Article
Times cited : (45)

References (49)
  • 2
    • 0031848730 scopus 로고    scopus 로고
    • Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry
    • Peters RD, Hinks RS, Henkelman RM,. Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magn Reson Med 1998; 40: 454-459. (Pubitemid 28391907)
    • (1998) Magnetic Resonance in Medicine , vol.40 , Issue.3 , pp. 454-459
    • Peters, R.D.1    Hinks, R.S.2    Henkelman, R.M.3
  • 3
    • 51849088469 scopus 로고    scopus 로고
    • MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: Segment-specific attainable precision and breathing influence
    • Rempp H, Martirosian P, Boss A, Clasen S, Kickhefel A, Kraiger M, Schraml C, Claussen C, Pereira P, Schick F,. MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: segment-specific attainable precision and breathing influence. MAGMA 2008; 21: 333-343.
    • (2008) MAGMA , vol.21 , pp. 333-343
    • Rempp, H.1    Martirosian, P.2    Boss, A.3    Clasen, S.4    Kickhefel, A.5    Kraiger, M.6    Schraml, C.7    Claussen, C.8    Pereira, P.9    Schick, F.10
  • 4
    • 48349094599 scopus 로고    scopus 로고
    • Magnetic resonance acoustic radiation force imaging
    • McDannold N, Maier SE,. Magnetic resonance acoustic radiation force imaging. Med Phys 2008; 35: 3748-3758.
    • (2008) Med Phys , vol.35 , pp. 3748-3758
    • McDannold, N.1    Maier, S.E.2
  • 6
    • 53549096544 scopus 로고    scopus 로고
    • Transient MR elastography (t-MRE) using ultrasound radiation force: Theory, safety, and initial experiments in vitro
    • Souchon R, Salomir R, Beuf O, Milot L, Grenier D, Lyonnet D, Chapelon JY, Rouviere O,. Transient MR elastography (t-MRE) using ultrasound radiation force: theory, safety, and initial experiments in vitro. Magn Reson Med 2008; 60: 871-881.
    • (2008) Magn Reson Med , vol.60 , pp. 871-881
    • Souchon, R.1    Salomir, R.2    Beuf, O.3    Milot, L.4    Grenier, D.5    Lyonnet, D.6    Chapelon, J.Y.7    Rouviere, O.8
  • 8
    • 33644802943 scopus 로고    scopus 로고
    • Feasibility of simultaneous temperature and tissue stiffness detection by MRE
    • DOI 10.1002/mrm.20801
    • Le Y, Glaser K, Rouviere O, Ehman R, Felmlee JP,. Feasibility of simultaneous temperature and tissue stiffness detection by MRE. Magn Reson Med 2006; 55: 700-705. (Pubitemid 43352572)
    • (2006) Magnetic Resonance in Medicine , vol.55 , Issue.3 , pp. 700-705
    • Le, Y.1    Glaser, K.2    Rouviere, O.3    Ehman, R.4    Felmlee, J.P.5
  • 12
    • 78649270482 scopus 로고    scopus 로고
    • Towards multifocal ultrasonic neural stimulation: Pattern generation algorithms
    • Hertzberg Y, Naor O, Volovick A, Shoham S,. Towards multifocal ultrasonic neural stimulation: pattern generation algorithms. J Neural Eng 2010; 7: 056002.
    • (2010) J Neural Eng , vol.7 , pp. 056002
    • Hertzberg, Y.1    Naor, O.2    Volovick, A.3    Shoham, S.4
  • 13
    • 77953530412 scopus 로고    scopus 로고
    • Ultrasound focusing using magnetic resonance acoustic radiation force imaging: Application to ultrasound transcranial therapy
    • Hertzberg Y, Volovick A, Zur Y, Medan Y, Vitek S, Navon G,. Ultrasound focusing using magnetic resonance acoustic radiation force imaging: application to ultrasound transcranial therapy. Med Phys 2010; 37: 2934-2942.
    • (2010) Med Phys , vol.37 , pp. 2934-2942
    • Hertzberg, Y.1    Volovick, A.2    Zur, Y.3    Medan, Y.4    Vitek, S.5    Navon, G.6
  • 14
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K, McDannold N, Vykhodtseva N, Jolesz FA,. Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 2001; 220: 640-646. (Pubitemid 32799969)
    • (2001) Radiology , vol.220 , Issue.3 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 15
    • 33947524046 scopus 로고    scopus 로고
    • Use of Ultrasound Pulses Combined with Definity for Targeted Blood-Brain Barrier Disruption: A Feasibility Study
    • DOI 10.1016/j.ultrasmedbio.2006.10.004, PII S0301562906018692
    • McDannold N, Vykhodtseva N, Hynynen K,. Use of ultrasound pulses combined with definity for targeted blood-brain barrier disruption: a feasibility study. Ultrasound Med Biol 2007; 33: 584-590. (Pubitemid 46467079)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.4 , pp. 584-590
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 16
    • 43849110904 scopus 로고    scopus 로고
    • Effects of Acoustic Parameters and Ultrasound Contrast Agent Dose on Focused-Ultrasound Induced Blood-Brain Barrier Disruption
    • DOI 10.1016/j.ultrasmedbio.2007.11.009, PII S0301562907005698
    • McDannold N, Vykhodtseva N, Hynynen K,. Effects of acoustic parameters and ultrasound contrast agent dose on focused-ultrasound induced blood-brain barrier disruption. Ultrasound Med Biol 2008; 34: 930-937. (Pubitemid 351697595)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.6 , pp. 930-937
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 17
    • 34547121440 scopus 로고    scopus 로고
    • Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound
    • DOI 10.1002/ijc.22732
    • Treat LH, McDannold N, Vykhodtseva N, Zhang Y, Tam K, Hynynen K,. Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound. Int J Cancer 2007; 121: 901-907. (Pubitemid 47106223)
    • (2007) International Journal of Cancer , vol.121 , Issue.4 , pp. 901-907
    • Treat, L.H.1    McDannold, N.2    Vykhodtseva, N.3    Zhang, Y.4    Tam, K.5    Hynynen, K.6
  • 18
    • 57249084281 scopus 로고    scopus 로고
    • Induction of apoptosis in sonoporation and ultrasonic gene transfer
    • Miller DL, Dou C,. Induction of apoptosis in sonoporation and ultrasonic gene transfer. Ultrasound Med Biol 2009; 35: 144-154.
    • (2009) Ultrasound Med Biol , vol.35 , pp. 144-154
    • Miller, D.L.1    Dou, C.2
  • 19
    • 0038402635 scopus 로고    scopus 로고
    • Sonoporation: Mechanical DNA delivery by ultrasonic cavitation
    • DOI 10.1023/A:1022983907223
    • Miller DL, Pislaru SV, Greenleaf JE,. Sonoporation: mechanical DNA delivery by ultrasonic cavitation. Somat Cell Mol Genet 2002; 27: 115-134. (Pubitemid 36553831)
    • (2001) Somatic Cell and Molecular Genetics , vol.27 , Issue.1-6 , pp. 115-134
    • Miller, D.L.1    Pislaru, S.V.2    Greenleaf, J.F.3
  • 21
    • 4644292155 scopus 로고    scopus 로고
    • Acoustically active liposomes for drug encapsulation and ultrasound-triggered release
    • DOI 10.1016/j.bbamem.2004.07.003, PII S0005273604001774
    • Huang SL, MacDonald RC,. Acoustically active liposomes for drug encapsulation and ultrasound-triggered release. Biochim Biophys Acta 2004; 1665: 134-141. (Pubitemid 39303578)
    • (2004) Biochimica et Biophysica Acta - Biomembranes , vol.1665 , Issue.1-2 , pp. 134-141
    • Huang, S.-L.1    MacDonald, R.C.2
  • 22
    • 76649106064 scopus 로고    scopus 로고
    • In vitro investigations into enhancement of tPA bioavailability in whole blood clots using pulsed-high intensity focused ultrasound exposures
    • Jones G, Hunter F, Hancock HA, Kapoor A, Stone MJ, Wood BJ, Xie J, Dreher MR, Frenkel V,. In vitro investigations into enhancement of tPA bioavailability in whole blood clots using pulsed-high intensity focused ultrasound exposures. IEEE Trans Biomed Eng 2010; 57: 33-36.
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 33-36
    • Jones, G.1    Hunter, F.2    Hancock, H.A.3    Kapoor, A.4    Stone, M.J.5    Wood, B.J.6    Xie, J.7    Dreher, M.R.8    Frenkel, V.9
  • 24
    • 36348972180 scopus 로고    scopus 로고
    • Pulsed-high intensity focused ultrasound enhanced tPA mediated thrombolysis in a novel in vivo clot model, a pilot study
    • DOI 10.1016/j.thromres.2007.03.023, PII S0049384807001259
    • Stone MJ, Frenkel V, Dromi S, Thomas P, Lewis RP, Li KC, Horne M, III, Wood BJ,. Pulsed-high intensity focused ultrasound enhanced tPA mediated thrombolysis in a novel in vivo clot model, a pilot study. Thromb Res 2007; 121: 193-202. (Pubitemid 350141674)
    • (2007) Thrombosis Research , vol.121 , Issue.2 , pp. 193-202
    • Stone, M.J.1    Frenkel, V.2    Dromi, S.3    Thomas, P.4    Lewis, R.P.5    Li, K.C.P.6    Horne III, M.7    Wood, B.J.8
  • 26
    • 0029654138 scopus 로고
    • Magnetic resonance elastography by direct visualization of propagating acoustic strain waves
    • Muthupillai R, Lomas DJ, Rossman PJ, Greenleaf JF, Manduca A, Ehman RL,. Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. Science 1995; 269: 1854-1857.
    • (1995) Science , vol.269 , pp. 1854-1857
    • Muthupillai, R.1    Lomas, D.J.2    Rossman, P.J.3    Greenleaf, J.F.4    Manduca, A.5    Ehman, R.L.6
  • 27
    • 77950621135 scopus 로고    scopus 로고
    • Optimization of encoding gradients for MR-ARFI
    • Chen J, Watkins R, Pauly KB,. Optimization of encoding gradients for MR-ARFI. Magn Reson Med 2010; 63: 1050-1058.
    • (2010) Magn Reson Med , vol.63 , pp. 1050-1058
    • Chen, J.1    Watkins, R.2    Pauly, K.B.3
  • 31
    • 53549111059 scopus 로고    scopus 로고
    • Evaluation of referenceless thermometry in MRI-guided focused ultrasound surgery of uterine fibroids
    • McDannold N, Tempany C, Jolesz F, Hynynen K,. Evaluation of referenceless thermometry in MRI-guided focused ultrasound surgery of uterine fibroids. J Magn Reson Imaging 2008; 28: 1026-1032.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1026-1032
    • McDannold, N.1    Tempany, C.2    Jolesz, F.3    Hynynen, K.4
  • 33
    • 58149267910 scopus 로고    scopus 로고
    • Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy
    • Rata M, Salomir R, Umathum R, Jenne J, Lafon C, Cotton F, Bock M,. Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy. Phys Med Biol 2008; 53: 6549-6567.
    • (2008) Phys Med Biol , vol.53 , pp. 6549-6567
    • Rata, M.1    Salomir, R.2    Umathum, R.3    Jenne, J.4    Lafon, C.5    Cotton, F.6    Bock, M.7
  • 34
    • 34548064624 scopus 로고    scopus 로고
    • Image-guided multipolar radiofrequency ablation of liver tumours: Initial clinical results
    • DOI 10.1007/s00330-007-0626-x
    • Terraz S, Constantin C, Majno PE, Spahr L, Mentha G, Becker CD,. Image-guided multipolar radiofrequency ablation of liver tumours: initial clinical results. Eur Radiol 2007; 17: 2253-2261. (Pubitemid 47288261)
    • (2007) European Radiology , vol.17 , Issue.9 , pp. 2253-2261
    • Terraz, S.1    Constantin, C.2    Majno, P.E.3    Spahr, L.4    Mentha, G.5    Becker, C.D.6
  • 35
    • 53849137361 scopus 로고    scopus 로고
    • Validation of fast MR thermometry at 1.5 T with gradient-echo echo planar imaging sequences: Phantom and clinical feasibility studies
    • Cernicanu A, Lepetit-Coiffe M, Roland J, Becker CD, Terraz S,. Validation of fast MR thermometry at 1.5 T with gradient-echo echo planar imaging sequences: phantom and clinical feasibility studies. NMR Biomed 2008; 21: 849-858.
    • (2008) NMR Biomed , vol.21 , pp. 849-858
    • Cernicanu, A.1    Lepetit-Coiffe, M.2    Roland, J.3    Becker, C.D.4    Terraz, S.5
  • 36
    • 77950566822 scopus 로고    scopus 로고
    • Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging
    • Viallon M, Terraz S, Roland J, Dumont E, Becker CD, Salomir R,. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging. Med Phys 2010; 37: 1491-1506.
    • (2010) Med Phys , vol.37 , pp. 1491-1506
    • Viallon, M.1    Terraz, S.2    Roland, J.3    Dumont, E.4    Becker, C.D.5    Salomir, R.6
  • 39
    • 15044352366 scopus 로고    scopus 로고
    • OsiriX: An open-source software for navigating in multidimensional DICOM images
    • DOI 10.1007/s10278-004-1014-6
    • Rosset A, Spadola L, Ratib O,. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging 2004; 17: 205-216. (Pubitemid 40378992)
    • (2004) Journal of Digital Imaging , vol.17 , Issue.3 , pp. 205-216
    • Rosset, A.1    Spadola, L.2    Ratib, O.3
  • 40
    • 0034087586 scopus 로고    scopus 로고
    • Hyperthermia by MR-guided focused ultrasound: Accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction
    • DOI 10.1002/(SICI)1522-2594(200003)43:3<342::AID-MRM4>3.0.CO;2-6
    • Salomir R, Vimeux FC, de Zwart JA, Grenier N, Moonen CT,. Hyperthermia by MR-guided focused ultrasound: accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction. Magn Reson Med 2000; 43: 342-347. (Pubitemid 30127519)
    • (2000) Magnetic Resonance in Medicine , vol.43 , Issue.3 , pp. 342-347
    • Salomir, R.1    Vimeux, F.C.2    De Zwart, J.A.3    Grenier, N.4    Moonen, C.T.W.5
  • 42
    • 77953685375 scopus 로고    scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG,. Statistical methods for assessing agreement between two methods of clinical measurement. Int J Nurs Stud 2010; 47: 931-936.
    • (2010) Int J Nurs Stud , vol.47 , pp. 931-936
    • Bland, J.M.1    Altman, D.G.2
  • 45
    • 0032975435 scopus 로고    scopus 로고
    • Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging
    • Yamada I, Aung W, Himeno Y, Nakagawa T, Shibuya H,. Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology 1999; 210: 617-623. (Pubitemid 29124018)
    • (1999) Radiology , vol.210 , Issue.3 , pp. 617-623
    • Yamada, I.1    Aung, W.2    Himeno, Y.3    Nakagawa, T.4    Shibuya, H.5
  • 47
    • 79951816274 scopus 로고    scopus 로고
    • Rapid MR-ARFI method for focal spot localization during focused ultrasound therapy
    • Kaye EA, Chen J, Pauly KB,. Rapid MR-ARFI method for focal spot localization during focused ultrasound therapy. Magn Reson Med 2011; 65: 738-743.
    • (2011) Magn Reson Med , vol.65 , pp. 738-743
    • Kaye, E.A.1    Chen, J.2    Pauly, K.B.3
  • 49


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.