메뉴 건너뛰기




Volumn 21, Issue 5, 2008, Pages 333-343

MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: Segment-specific attainable precision and breathing influence

Author keywords

Proton resonance frequency shift method; Radiofrequency ablation; Temperature mapping; Thermoablative therapies; Thermometry

Indexed keywords

ADULT; ARTICLE; BREATHING PATTERN; CONTROLLED STUDY; EXPIRATORY FLOW; FEMALE; HUMAN; HUMAN EXPERIMENT; KIDNEY PARENCHYMA; LIVER PARENCHYMA; MAGNETIC FIELD; MALE; NORMAL HUMAN; PRIORITY JOURNAL; PROTON NUCLEAR MAGNETIC RESONANCE; TEMPERATURE MEASUREMENT; THERMOMETRY;

EID: 51849088469     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-008-0139-x     Document Type: Article
Times cited : (20)

References (36)
  • 1
    • 0034853643 scopus 로고    scopus 로고
    • Image-guided radiofrequency tumor ablation: Challenges and opportunities
    • SN Goldberg DE Dupuy 2001 Image-guided radiofrequency tumor ablation: challenges and opportunities I J Vasc Interv Radiol 12 1021 1032
    • (2001) I J Vasc Interv Radiol , vol.12 , pp. 1021-1032
    • Goldberg, S.N.1    Dupuy, D.E.2
  • 3
    • 30344483975 scopus 로고    scopus 로고
    • Percutaneous microwave and radiofrequency ablation for hepatocellular carcinoma: A retrospective comparative study
    • 11
    • MD Lu HX Xu XY Xie XY Yin JW Chen M Kuang ZF Xu GJ Liu YL Zheng 2005 Percutaneous microwave and radiofrequency ablation for hepatocellular carcinoma: a retrospective comparative study J Gastroenterol 40 11 1054 1060
    • (2005) J Gastroenterol , vol.40 , pp. 1054-1060
    • Lu, M.D.1    Xu, H.X.2    Xie, X.Y.3    Yin, X.Y.4    Chen, J.W.5    Kuang, M.6    Xu, Z.F.7    Liu, G.J.8    Zheng, Y.L.9
  • 4
    • 1642540074 scopus 로고    scopus 로고
    • Colorectal carcinoma metastases in liver: Laser-induced interstitial thermotherapy-local tumor control rate and survival data
    • 2
    • TJ Vogl R Straub K Eichler O Sollner MG Mack 2004 Colorectal carcinoma metastases in liver: laser-induced interstitial thermotherapy-local tumor control rate and survival data Radiology 230 2 450 458
    • (2004) Radiology , vol.230 , pp. 450-458
    • Vogl, T.J.1    Straub, R.2    Eichler, K.3    Sollner, O.4    MacK, M.G.5
  • 5
    • 16644364409 scopus 로고    scopus 로고
    • Extracorporeal high intensity focused ultrasound ablation in the treatment of patients with large hepatocellular carcinoma
    • 12
    • F Wu ZB Wang WZ Chen H Zhu J Bai JZ Zou KQ Li CB Jin FL Xie HB Su 2004 Extracorporeal high intensity focused ultrasound ablation in the treatment of patients with large hepatocellular carcinoma Ann Surg Oncol 11 12 1061 1069
    • (2004) Ann Surg Oncol , vol.11 , pp. 1061-1069
    • Wu, F.1    Wang, Z.B.2    Chen, W.Z.3    Zhu, H.4    Bai, J.5    Zou, J.Z.6    Li, K.Q.7    Jin, C.B.8    Xie, F.L.9    Su, H.B.10
  • 11
    • 33745011884 scopus 로고    scopus 로고
    • Thermal diffusivity and nuclear spin relaxation: A continuous wave free precession NMR study
    • 1
    • T Venancio M Engelsberg RB Azeredo LA Colnago 2006 Thermal diffusivity and nuclear spin relaxation: a continuous wave free precession NMR study J Magn Reson 181 1 29 34
    • (2006) J Magn Reson , vol.181 , pp. 29-34
    • Venancio, T.1    Engelsberg, M.2    Azeredo, R.B.3    Colnago, L.A.4
  • 12
    • 0020629894 scopus 로고
    • Temperature distribution measurements in two-dimensional NMR imaging
    • DL Parker V Smith P Sheldon LE Crooks L Fussel 1983 Temperature distribution measurements in two-dimensional NMR imaging Med phys 10 321 325
    • (1983) Med Phys , vol.10 , pp. 321-325
    • Parker, D.L.1    Smith, V.2    Sheldon, P.3    Crooks, L.E.4    Fussel, L.5
  • 14
    • 33745111183 scopus 로고    scopus 로고
    • Noninvasive magnetic resonance thermography of soft tissue sarcomas during regional hyperthermia: Correlation with response and direct thermometry
    • 6
    • J Gellermann B Hildebrandt R Issels H Ganter W Wlodarczyk V Budach R Felix PU Tunn P Reichardt P Wust 2006 Noninvasive magnetic resonance thermography of soft tissue sarcomas during regional hyperthermia: correlation with response and direct thermometry Cancer 107 6 1373 1382
    • (2006) Cancer , vol.107 , pp. 1373-1382
    • Gellermann, J.1    Hildebrandt, B.2    Issels, R.3    Ganter, H.4    Wlodarczyk, W.5    Budach, V.6    Felix, R.7    Tunn, P.U.8    Reichardt, P.9    Wust, P.10
  • 15
    • 36849111386 scopus 로고
    • Proton resonance shift of water in the gas and liquid state
    • JC Hindman 1966 Proton resonance shift of water in the gas and liquid state J Chem Phys 44 4582 4592
    • (1966) J Chem Phys , vol.44 , pp. 4582-4592
    • Hindman, J.C.1
  • 16
    • 0029112548 scopus 로고
    • Noninvasive MRI thermometry with the proton resonance frequency method: Study of susceptibility effects
    • 3
    • J De Poorter 1995 Noninvasive MRI thermometry with the proton resonance frequency method: study of susceptibility effects Magn Reson Med 34 3 359 367
    • (1995) Magn Reson Med , vol.34 , pp. 359-367
    • De Poorter, J.1
  • 17
    • 0028854080 scopus 로고
    • Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: In vivo results in human muscle
    • 1
    • J De Poorter C De Wagter Y De Deene C Thomsen F Ståhlberg E Achten 1995 Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle Magn Reson Med 33 1 74 81
    • (1995) Magn Reson Med , vol.33 , pp. 74-81
    • De Poorter, J.1    De Wagter, C.2    De Deene, Y.3    Thomsen, C.4    Ståhlberg, F.5    Achten, E.6
  • 18
    • 0031848730 scopus 로고    scopus 로고
    • Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry
    • 3
    • RD Peters RS Hinks RM Henkelman 1998 Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry Magn Reson Med 40 3 454 459
    • (1998) Magn Reson Med , vol.40 , pp. 454-459
    • Peters, R.D.1    Hinks, R.S.2    Henkelman, R.M.3
  • 19
    • 0035116428 scopus 로고    scopus 로고
    • Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation
    • 3
    • RM Botnar P Steiner B Dubno P Erhart GK von Schulthess JF Debatin 2001 Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation J Magn Reson Imaging 13 3 437 444
    • (2001) J Magn Reson Imaging , vol.13 , pp. 437-444
    • Botnar, R.M.1    Steiner, P.2    Dubno, B.3    Erhart, P.4    Von Schulthess, G.K.5    Debatin, J.F.6
  • 22
    • 33748456010 scopus 로고    scopus 로고
    • Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver : aan ex vivo study
    • O Seror M Lepetit-Coiffé B Quesson H Trillaud CT Moonen 2006 Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver : an ex vivo study Eur Radiol 16 2265 2274
    • (2006) Eur Radiol , vol.16 , pp. 2265-2274
    • Seror, O.1    Lepetit-Coiffé, M.2    Quesson, B.3    Trillaud, H.4    Moonen, C.T.5
  • 23
    • 0242290981 scopus 로고    scopus 로고
    • Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion
    • 5
    • KK Vigen BL Daniel JM Pauly 2003 Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion Magn Reson Med 50 5 1003 1010
    • (2003) Magn Reson Med , vol.50 , pp. 1003-1010
    • Vigen, K.K.1    Daniel, B.L.2    Pauly, J.M.3
  • 24
    • 33748556205 scopus 로고    scopus 로고
    • Correction of proton resonance frequency shift temperature maps for magnetic field disturbances caused by breathing
    • AV Shmatukha CJG Bakker 2006 Correction of proton resonance frequency shift temperature maps for magnetic field disturbances caused by breathing Phys Med Biol 41 4689 705
    • (2006) Phys Med Biol , vol.41 , pp. 4689-705
    • Shmatukha, A.V.1    Bakker, C.J.G.2
  • 25
    • 33847635628 scopus 로고    scopus 로고
    • Correction of proton resonance frequency shift temperature maps for magnetic field disturbances using fat signal
    • MS Shmatukha PR Harvey CJG Bakker 2007 Correction of proton resonance frequency shift temperature maps for magnetic field disturbances using fat signal J Magn Reson Imaging 25 579 87
    • (2007) J Magn Reson Imaging , vol.25 , pp. 579-87
    • Shmatukha, M.S.1    Harvey, P.R.2    Bakker, C.J.G.3
  • 28
    • 0033818660 scopus 로고    scopus 로고
    • Magnetic resonance temperature imaging for guidance of thermotherapy
    • 4
    • B Quesson JA de Zwart CT Moonen 2000 Magnetic resonance temperature imaging for guidance of thermotherapy J Magn Reson Imaging 12 4 525 533
    • (2000) J Magn Reson Imaging , vol.12 , pp. 525-533
    • Quesson, B.1    De Zwart, J.A.2    Moonen, C.T.3
  • 29
    • 0029958301 scopus 로고    scopus 로고
    • Optimization of spoiled gradient-echo phase imaging for in vivo location of a focused ultrasound beam
    • 5
    • AH Chung K Hynynen V Colucci K Oshio HE Cline FA Jolesz 1996 Optimization of spoiled gradient-echo phase imaging for in vivo location of a focused ultrasound beam Magn Reson Med 36 5 745 752
    • (1996) Magn Reson Med , vol.36 , pp. 745-752
    • Chung, A.H.1    Hynynen, K.2    Colucci, V.3    Oshio, K.4    Cline, H.E.5    Jolesz, F.A.6
  • 30
    • 0028785052 scopus 로고
    • A precise and fast temperature mapping using water proton chemical shift
    • 6
    • Y Ishihara A Calderon H Watanabe 1995 A precise and fast temperature mapping using water proton chemical shift Magn Reson Med 34 6 814 823
    • (1995) Magn Reson Med , vol.34 , pp. 814-823
    • Ishihara, Y.1    Calderon, A.2    Watanabe, H.3
  • 33
    • 77956889208 scopus 로고
    • Recovery of inter-block information when block sizes are unequal
    • 3
    • HD Patterson R Thompson 1971 Recovery of inter-block information when block sizes are unequal Biometrika 58 3 545 554
    • (1971) Biometrika , vol.58 , pp. 545-554
    • Patterson, H.D.1    Thompson, R.2
  • 34
    • 0031933418 scopus 로고    scopus 로고
    • Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle
    • 2
    • SJ Graham MJ Bronskill RM Henkelman 1998 Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle Magn Reson Med 39 2 198 03
    • (1998) Magn Reson Med , vol.39 , pp. 198-03
    • Graham, S.J.1    Bronskill, M.J.2    Henkelman, R.M.3
  • 36
    • 28444464393 scopus 로고    scopus 로고
    • Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method
    • A Boss H Graf B Müller-Bierl S Clasen D Schmidt PL Pereira F Schick 2005 Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method J Magn Reson Imaging 22 813 820
    • (2005) J Magn Reson Imaging , vol.22 , pp. 813-820
    • Boss, A.1    Graf, H.2    Müller-Bierl, B.3    Clasen, S.4    Schmidt, D.5    Pereira, P.L.6    Schick, F.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.