메뉴 건너뛰기




Volumn 31, Issue 9, 2012, Pages 978-982

Corneal thickness measurement using orbscan, pentacam, galilei, and ultrasound in normal and post-femtosecond laser in situ keratomileusis eyes

Author keywords

central corneal thickness; dual Scheimpflug system; Femtosecond LASIK; rotating Scheimpflug imaging; slit scanning system

Indexed keywords

ADULT; ARTICLE; CORNEA; CORNEA THICKNESS; ECHOOCULOGRAPHY; FEMALE; FEMTOSECOND LASER; HUMAN; INTERMETHOD COMPARISON; KERATOMILEUSIS; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; OUTCOME ASSESSMENT; PREOPERATIVE PERIOD; PRIORITY JOURNAL; REFRACTION ERROR;

EID: 84865526345     PISSN: 02773740     EISSN: 15364798     Source Type: Journal    
DOI: 10.1097/ICO.0b013e31823d03fc     Document Type: Article
Times cited : (38)

References (24)
  • 1
    • 0347662615 scopus 로고
    • Ectasia after laser in situ keratomileusis
    • Binder PS. Ectasia after laser in situ keratomileusis. J Cataract Refract Surg. 1978;29:2419 - 2429.
    • (1978) J Cataract Refract Surg , vol.29 , pp. 2419-2429
    • Binder, P.S.1
  • 2
    • 12944305943 scopus 로고    scopus 로고
    • Central corneal pachymetry in patients undergoing laser in situ keratomileusis
    • Price FW Jr, Koller DL, Price MO. Central corneal pachymetry in patients undergoing laser in situ keratomileusis. Ophthalmology. 1999; 106:2216 - 2220.
    • (1999) Ophthalmology , vol.106 , pp. 2216-2220
    • Price Jr., F.W.1    Koller, D.L.2    Price, M.O.3
  • 3
    • 0033913306 scopus 로고    scopus 로고
    • Postoperative complications in laser in situ keratomileusis
    • Iskander NG, Peters NT, Penno EA, et al. Postoperative complications in laser in situ keratomileusis. Curr Opin Ophthalmol. 2000;11: 273 - 279.
    • (2000) Curr Opin Ophthalmol , vol.11 , pp. 273-279
    • Iskander, N.G.1    Peters, N.T.2    Penno, E.A.3
  • 4
    • 0942301213 scopus 로고    scopus 로고
    • Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness
    • Miglior S, Albe E, Guareschi M, et al. Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness. Br J Ophthalmol. 2004;88:174 - 177.
    • (2004) Br J Ophthalmol. , vol.88 , pp. 174-177
    • Miglior, S.1    Albe, E.2    Guareschi, M.3
  • 5
    • 0032930812 scopus 로고    scopus 로고
    • Corneal indentation during ultrasonic pachometry
    • Solomon OD. Corneal indentation during ultrasonic pachometry. Cornea. 1999;18:214 - 215.
    • (1999) Cornea , vol.18 , pp. 214-215
    • Solomon, O.D.1
  • 6
    • 14744278223 scopus 로고    scopus 로고
    • Central and peripheral corneal pachymetry - standard evaluation with the Pentacam system
    • Rufer F, Schroder A, Arvani MK, et al. Central and peripheral corneal pachymetry - standard evaluation with the Pentacam system. Klin Monatsbl Augenheilkd. 2005;222:117 - 122.
    • (2005) Klin Monatsbl Augenheilkd. , vol.222 , pp. 117-122
    • Rufer, F.1    Schroder, A.2    Arvani, M.K.3
  • 7
    • 52249090464 scopus 로고    scopus 로고
    • Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems
    • Menassa N, Kaufmann C, Goggin M, et al. Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems. J Cataract Refract Surg. 2008;34: 1742 - 1747.
    • (2008) J Cataract Refract Surg. , vol.34 , pp. 1742-1747
    • Menassa, N.1    Kaufmann, C.2    Goggin, M.3
  • 8
    • 78650709901 scopus 로고    scopus 로고
    • Corneal imaging with slit-scanning and Scheimpflug imaging techniques
    • doi:10.1111/j.1444 - 0938.2010.00509.x
    • Oliveira CM, Ribeiro C, Franco S. Corneal imaging with slit-scanning and Scheimpflug imaging techniques. Clin Exp Optom. 2011;94:33 - 42. doi:10.1111/j.1444 - 0938.2010.00509.x.
    • Clin Exp Optom. , vol.2011 , Issue.94 , pp. 33-42
    • Oliveira, C.M.1    Ribeiro, C.2    Franco, S.3
  • 9
    • 36448970833 scopus 로고    scopus 로고
    • Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry
    • Kim SW, Byun YJ, Kim EK, et al. Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry. J Refract Surg. 2007;23:888 - 894.
    • (2007) J Refract Surg , vol.23 , pp. 888-894
    • Kim, S.W.1    Byun, Y.J.2    Kim, E.K.3
  • 10
    • 33646906826 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography
    • Amano S, Honda N, Amano Y, et al. Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography. Ophthalmology. 2006;113:937 - 941.
    • (2006) Ophthalmology , vol.113 , pp. 937-941
    • Amano, S.1    Honda, N.2    Amano, Y.3
  • 11
    • 34548748620 scopus 로고    scopus 로고
    • Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia
    • Hashemi H, Mehravaran S. Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia. J Cataract Refract Surg. 2007;33: 1701 - 1707.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1701-1707
    • Hashemi, H.1    Mehravaran, S.2
  • 12
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with pentacam orbscan and ultrasound
    • Lackner B, Schmidinger G, Pieh S, et al. Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom Vis Sci. 2005;82:892 - 899.
    • (2005) Optom Vis Sci. , vol.82 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3
  • 13
    • 0033759092 scopus 로고    scopus 로고
    • The repeatability of corneal thickness measures
    • Marsich MW, Bullimore MA. The repeatability of corneal thickness measures. Cornea. 2000;19:792 - 795.
    • (2000) Cornea , vol.19 , pp. 792-795
    • Marsich, M.W.1    Bullimore, M.A.2
  • 14
    • 0037255230 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    • Gonzalez-Meijome JM, Cervino A, Yebra-Pimentel E, et al. Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry. J Cataract Refract Surg. 2003; 29:125 - 132.
    • (2003) J Cataract Refract Surg. , vol.29 , pp. 125-132
    • Gonzalez-Meijome, J.M.1    Cervino, A.2    Yebra-Pimentel, E.3
  • 15
    • 34250648821 scopus 로고    scopus 로고
    • Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia
    • Ho T, Cheng AC, Rao SK, et al. Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 2008;33: 1177 - 1182.
    • (2008) J Cataract Refract Surg , vol.33 , pp. 1177-1182
    • Ho, T.1    Cheng, A.C.2    Rao, S.K.3
  • 16
    • 77955896453 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry
    • Ladi JS, Shah NA. Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry. Indian J Ophthalmol. 2010;58:385 - 388.
    • (2010) Indian J Ophthalmol , vol.58 , pp. 385-388
    • Ladi, J.S.1    Shah, N.A.2
  • 17
    • 52249090464 scopus 로고    scopus 로고
    • Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems
    • Menassa N, Kaufmann C, Goggin M, et al. Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems. J Cataract Refract Surg. 2008;34: 1742 - 1747.
    • (2008) J Cataract Refract Surg. , vol.34 , pp. 1742-1747
    • Menassa, N.1    Kaufmann, C.2    Goggin, M.3
  • 18
    • 77958152090 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using Galilei, HR Pentacam, and ultrasound
    • Jahadi Hosseini HR, Katbab A, Khalili MR, et al. Comparison of corneal thickness measurements using Galilei, HR Pentacam, and ultrasound. Cornea. 2010;29:1091 - 1095.
    • (2010) Cornea , vol.29 , pp. 1091-1095
    • Jahadi Hosseini, H.R.1    Katbab, A.2    Khalili, M.R.3
  • 19
    • 0035161383 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes
    • Chakrabarti HS, Craig JP, Brahma A, et al. Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes. J Cataract Refract Surg. 2001;27: 1823 - 1828.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1823-1828
    • Chakrabarti, H.S.1    Craig, J.P.2    Brahma, A.3
  • 20
    • 0343773370 scopus 로고    scopus 로고
    • Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures
    • Iskander NG, Anderson Penno E, Peters NT, et al. Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures. J Cataract Refract Surg. 2001;27:681 - 685.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 681-685
    • Iskander, N.G.1    Anderson Penno, E.2    Peters, N.T.3
  • 21
    • 33645945900 scopus 로고    scopus 로고
    • Pachymetry assessment with Orbscan II in postoperative patients with myopic LASIK
    • Cheng AC, Rao SK, Tang E, et al. Pachymetry assessment with Orbscan II in postoperative patients with myopic LASIK. J Refract Surg. 2006;22: 363 - 366.
    • (2006) J Refract Surg , vol.22 , pp. 363-366
    • Cheng, A.C.1    Rao, S.K.2    Tang, E.3
  • 22
    • 0037373268 scopus 로고    scopus 로고
    • Reliability of pachymetric measurements using Orbscan after excimer refractive surgery
    • Prisant O, Calderon N, Chastang P, et al. Reliability of pachymetric measurements using Orbscan after excimer refractive surgery. Ophthalmology. 2003;110:511 - 515.
    • (2003) Ophthalmology , vol.110 , pp. 511-515
    • Prisant, O.1    Calderon, N.2    Chastang, P.3
  • 23
    • 1842609805 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis
    • Kawana K, Tokunaga T, Miyata K, et al. Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis. Br J Ophthalmol. 2004;88:466 - 468.
    • (2004) Br J Ophthalmol , vol.88 , pp. 466-468
    • Kawana, K.1    Tokunaga, T.2    Miyata, K.3
  • 24
    • 0036168963 scopus 로고    scopus 로고
    • Accuracy of Orbscan optical pachymetry in corneas with haze
    • Boscia F, La Tegola MG, Alessio G, et al. Accuracy of Orbscan optical pachymetry in corneas with haze. J Cataract Refract Surg. 2002;28: 253 - 258.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 253-258
    • Boscia, F.1    La Tegola, M.G.2    Alessio, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.