메뉴 건너뛰기




Volumn 6, Issue 4, 2012, Pages 282-289

Gating the mechanical channel Piezo1: A comparison between whole-cell and patch recording

Author keywords

Cell swelling; Channel gating; Cytoskeleton; Inactivation; Mechanical ion channels; Patch currents; Piezo1; Whole cell currents

Indexed keywords

ACTIN; CALCIUM ION; CYTOCHALASIN D; IOBENZAMIC ACID; ION CHANNEL; MAGNESIUM ION; PIEZO1 ION CHANNEL; UNCLASSIFIED DRUG; ZINC ION; CALCIUM; MAGNESIUM; PIEZO1 PROTEIN, HUMAN; ZINC;

EID: 84865297043     PISSN: 19336950     EISSN: 19336969     Source Type: Journal    
DOI: 10.4161/chan.21064     Document Type: Article
Times cited : (160)

References (30)
  • 1
    • 77957332682 scopus 로고    scopus 로고
    • Piezo1 and Piezo2 are essential components of distinct mechanically activated cation channels
    • PMID:20813920
    • Coste B, Mathur J, Schmidt M, Earley TJ, Ranade S, Petrus MJ, et al. Piezo1 and Piezo2 are essential components of distinct mechanically activated cation channels. Science 2010; 330:55-60; PMID:20813920; http://dx.doi.org/10. 1126/science.1193270.
    • (2010) Science , vol.330 , pp. 55-60
    • Coste, B.1    Mathur, J.2    Schmidt, M.3    Earley, T.J.4    Ranade, S.5    Petrus, M.J.6
  • 2
    • 84862777142 scopus 로고    scopus 로고
    • Piezo proteins are pore-forming subunits of mechanically activated channels
    • PMID:22343900
    • Coste B, Xiao B, Santos JS, Syeda R, Grandl J, Spencer KS, et al. Piezo proteins are pore-forming subunits of mechanically activated channels. Nature 2012; 483:176-81; PMID:22343900; http://dx.doi.org/10.1038/nature10812.
    • (2012) Nature , vol.483 , pp. 176-181
    • Coste, B.1    Xiao, B.2    Santos, J.S.3    Syeda, R.4    Grandl, J.5    Spencer, K.S.6
  • 3
    • 79960498823 scopus 로고    scopus 로고
    • The mechanosensitive ion channel Piezo1 is inhibited by the peptide GsMTx4
    • PMID:21696149
    • Bae C, Sachs F, Gottlieb PA. The mechanosensitive ion channel Piezo1 is inhibited by the peptide GsMTx4. Biochemistry 2011; 50:6295-300; PMID:21696149; http://dx.doi.org/10.1021/bi200770q.
    • (2011) Biochemistry , vol.50 , pp. 6295-6300
    • Bae, C.1    Sachs, F.2    Gottlieb, P.A.3
  • 4
    • 84862776759 scopus 로고    scopus 로고
    • The role of Drosophila Piezo in mechanical nociception
    • PMID:22343891
    • Kim SE, Coste B, Chadha A, Cook B, Patapoutian A. The role of Drosophila Piezo in mechanical nociception. Nature 2012; 483:209-12; PMID:22343891; http://dx.doi.org/10.1038/nature10801.
    • (2012) Nature , vol.483 , pp. 209-212
    • Kim, S.E.1    Coste, B.2    Chadha, A.3    Cook, B.4    Patapoutian, A.5
  • 5
    • 68849117075 scopus 로고    scopus 로고
    • Biophysics and structure of the patch and the gigaseal
    • PMID:19651032
    • Suchyna TM, Markin VS, Sachs F. Biophysics and structure of the patch and the gigaseal. Biophys J 2009; 97:738-47; PMID:19651032; http://dx.doi.org/10. 1016/j.bpj.2009.05.018.
    • (2009) Biophys J , vol.97 , pp. 738-747
    • Suchyna, T.M.1    Markin, V.S.2    Sachs, F.3
  • 6
    • 33646469698 scopus 로고    scopus 로고
    • Desensitization of mechano-gated K2P channels
    • PMID:16636285
    • Honoré E, Patel AJ, Chemin J, Suchyna T, Sachs F. Desensitization of mechano-gated K2P channels. Proc Natl Acad Sci USA 2006; 103:6859-64; PMID:16636285; http://dx.doi.org/10.1073/pnas.0600463103.
    • (2006) Proc Natl Acad Sci USA , vol.103 , pp. 6859-6864
    • Honoré, E.1    Patel, A.J.2    Chemin, J.3    Suchyna, T.4    Sachs, F.5
  • 7
    • 17844405808 scopus 로고    scopus 로고
    • Maximum likelihood estimation of ion channel kinetics from macroscopic currents
    • PMID:15681642
    • Milescu LS, Akk G, Sachs F. Maximum likelihood estimation of ion channel kinetics from macroscopic currents. Biophys J 2005; 88:2494-515; PMID:15681642; http://dx.doi.org/10.1529/biophysj.104.053256.
    • (2005) Biophys J , vol.88 , pp. 2494-2515
    • Milescu, L.S.1    Akk, G.2    Sachs, F.3
  • 8
    • 84865288128 scopus 로고    scopus 로고
    • The link between patch capacitance and mechanosensitive channel function probed with MSC blockers and activators
    • SuchynaT, SachsF. The link between patch capacitance and mechanosensitive channel function probed with MSC blockers and activators. Biophysical Journal 2004; 86:548.
    • (2004) Biophysical Journal , vol.86 , pp. 548
    • Suchyna, T.1    Sachs, F.2
  • 9
    • 54749149081 scopus 로고    scopus 로고
    • Atomic force microscopy analysis of cell volume regulation
    • PMID:18851074
    • Spagnoli C, Beyder A, BeschS, Sachs F. Atomic force microscopy analysis of cell volume regulation. Phys Rev E Stat Nonlin Soft Matter Phys 2008; 78:031916; PMID:18851074; http://dx.doi.org/10.1103/PhysRevE.78.031916.
    • (2008) Phys Rev e Stat Nonlin Soft Matter Phys , vol.78 , pp. 031916
    • Spagnoli, C.1    Beyder, A.2    Besch, S.3    Sachs, F.4
  • 10
    • 80053426150 scopus 로고    scopus 로고
    • Kinetics of hole nucleation in biomembrane rupture
    • PMID:21966242
    • Evans E, Smith BA. Kinetics of hole nucleation in biomembrane rupture. New J Phys 2011; 13:095010; PMID:21966242; http://dx.doi.org/10.1088/1367-2630/ 13/9/095010.
    • (2011) New J Phys , vol.13 , pp. 095010
    • Evans, E.1    Smith, B.A.2
  • 11
    • 33745460232 scopus 로고    scopus 로고
    • Membrane electroporation theories: A review
    • PMID:16929916
    • Chen C, Smye SW, Robinson MP, Evans JA. Membrane electroporation theories: a review. Med Biol Eng Comput 2006; 44:5-14; PMID:16929916; http://dx.doi.org/10.1007/s11517-005-0020-2.
    • (2006) Med Biol Eng Comput , vol.44 , pp. 5-14
    • Chen, C.1    Smye, S.W.2    Robinson, M.P.3    Evans, J.A.4
  • 12
    • 0031808801 scopus 로고    scopus 로고
    • The breakdown of cell membranes by electrical and mechanical stress
    • PMID:9649384
    • Akinlaja J, Sachs F. The breakdown of cell membranes by electrical and mechanical stress. Biophys J 1998; 75:247-54; PMID:9649384; http://dx.doi.org/ 10.1016/S0006-3495(98)77511-3.
    • (1998) Biophys J , vol.75 , pp. 247-254
    • Akinlaja, J.1    Sachs, F.2
  • 13
    • 82955168986 scopus 로고    scopus 로고
    • Modeling ion channels in the gigaseal
    • PMID:22261052
    • Bae C, Markin V, Suchyna T, Sachs F. Modeling ion channels in the gigaseal. Biophys J 2011; 101:2645-51; PMID:22261052; http://dx.doi.org/10.1016/ j.bpj.2011.11.002.
    • (2011) Biophys J , vol.101 , pp. 2645-2651
    • Bae, C.1    Markin, V.2    Suchyna, T.3    Sachs, F.4
  • 14
    • 0031079796 scopus 로고    scopus 로고
    • Mechanogated channels in Xenopus oocytes: Different gating modes enable a channel to switch from a phasic to a tonic mechanotransducer
    • PMID:9057280
    • Hamill OP, McBride DW Jr. Mechanogated channels in Xenopus oocytes: different gating modes enable a channel to switch from a phasic to a tonic mechanotransducer. Biol Bull 1997; 192:121-2; PMID:9057280; http://dx.doi.org/ 10.2307/1542583.
    • (1997) Biol Bull , vol.192 , pp. 121-122
    • Hamill, O.P.1    McBride Jr., D.W.2
  • 15
    • 34248172959 scopus 로고    scopus 로고
    • Mechanosensitive channel properties and membrane mechanics in mouse dystrophic myotubes
    • PMID:17255168
    • Suchyna T, Sachs F. Mechanosensitive channel properties and membrane mechanics in mouse dystrophic myotubes. J Physiol 2007; 581:369-87; PMID:17255168; http://dx.doi.org/10.1113/jphysiol.2006.125021.
    • (2007) J Physiol , vol.581 , pp. 369-387
    • Suchyna, T.1    Sachs, F.2
  • 16
    • 33646542514 scopus 로고    scopus 로고
    • Dynamic regulation of mechanosensitive channels: Capacitance used to monitor patch tension in real time
    • PMID:16204817
    • Suchyna TM, Besch SR, Sachs F. Dynamic regulation of mechanosensitive channels: capacitance used to monitor patch tension in real time. Phys Biol 2004; 1:1-18; PMID:16204817; http://dx.doi.org/10.1088/1478-3967/1/1/001.
    • (2004) Phys Biol , vol.1 , pp. 1-18
    • Suchyna, T.M.1    Besch, S.R.2    Sachs, F.3
  • 17
    • 3142652571 scopus 로고    scopus 로고
    • Bilayer-dependent inhibition of mechanosensitive channels by neuroactive peptide enantiomers
    • PMID:15241420
    • Suchyna TM, Tape SE, Koeppe RE 2nd, Andersen OS, Sachs F, Gottlieb PA. Bilayer-dependent inhibition of mechanosensitive channels by neuroactive peptide enantiomers. Nature 2004; 430:235-40; PMID:15241420; http://dx.doi.org/10.1038/ nature02743.
    • (2004) Nature , vol.430 , pp. 235-240
    • Suchyna, T.M.1    Tape, S.E.2    Koeppe II, R.E.3    Andersen, O.S.4    Sachs, F.5    Gottlieb, P.A.6
  • 18
    • 0032444901 scopus 로고    scopus 로고
    • Lipid and cell membranes in the presence of gadolinium and other ions with high affinity to lipids. 2. A dipole component of the boundary potential on membranes with different surface charge
    • PMID:10024973
    • Ermakov YuA, Averbakh AZ, Arbuzova AB, Sukharev SI. Lipid and cell membranes in the presence of gadolinium and other ions with high affinity to lipids. 2. A dipole component of the boundary potential on membranes with different surface charge. Membr Cell Biol 1998; 12:411-26; PMID:10024973.
    • (1998) Membr Cell Biol , vol.12 , pp. 411-426
    • Ermakov, Yu.A.1    Averbakh, A.Z.2    Arbuzova, A.B.3    Sukharev, S.I.4
  • 19
    • 0031413431 scopus 로고    scopus 로고
    • Lipid and cell membranes in the presence of gadolinium and other ions with high affinity to lipids. 1. Dipole and diffuse components of the boundary potential
    • PMID:9553941
    • Ermakov YuA, Averbakh AZ, Sukharev SI. Lipid and cell membranes in the presence of gadolinium and other ions with high affinity to lipids. 1. Dipole and diffuse components of the boundary potential. Membr Cell Biol 1997; 11:539-54; PMID:9553941.
    • (1997) Membr Cell Biol , vol.11 , pp. 539-554
    • Ermakov, Yu.A.1    Averbakh, A.Z.2    Sukharev, S.I.3
  • 20
    • 0003099248 scopus 로고
    • Functional reconstitution as an assay for biochemical isolation of channel proteins: Application to the molecuar identification of a bacterial mechanosensitive channel
    • Sukharev SI, Martinac B, Blount P, Kung C. Functional reconstitution as an assay for biochemical isolation of channel proteins: application to the molecuar identification of a bacterial mechanosensitive channel. Methods: A Companion to Methods in Enzymology 1994; 6:51-9.
    • (1994) Methods: A Companion to Methods in Enzymology , vol.6 , pp. 51-59
    • Sukharev, S.I.1    Martinac, B.2    Blount, P.3    Kung, C.4
  • 21
    • 0028224356 scopus 로고
    • A large-conductance mechanosensitive channel in E. coli encoded by mscL alone
    • PMID:7511799
    • Sukharev SI, Blount P, Martinac B, Blattner FR, Kung C. A large-conductance mechanosensitive channel in E. coli encoded by mscL alone. Nature 1994; 368:265-8; PMID:7511799; http://dx.doi.org/10.1038/368265a0.
    • (1994) Nature , vol.368 , pp. 265-268
    • Sukharev, S.I.1    Blount, P.2    Martinac, B.3    Blattner, F.R.4    Kung, C.5
  • 22
    • 79953192175 scopus 로고    scopus 로고
    • Ankyrin-B interactions with spectrin and dynactin-4 are required for dystrophin-based protection of skeletal muscle from exercise injury
    • PMID:21186323
    • Ayalon G, Hostettler JD, Hoffman J, Kizhatil K, Davis JQ, Bennett V. Ankyrin-B interactions with spectrin and dynactin-4 are required for dystrophin-based protection of skeletal muscle from exercise injury. J Biol Chem 2011; 286:7370-8; PMID:21186323; http://dx.doi.org/10.1074/jbc.M110.187831.
    • (2011) J Biol Chem , vol.286 , pp. 7370-7378
    • Ayalon, G.1    Hostettler, J.D.2    Hoffman, J.3    Kizhatil, K.4    Davis, J.Q.5    Bennett, V.6
  • 23
    • 34547098347 scopus 로고    scopus 로고
    • In situ measurements of calpain activity in isolated muscle fibres from normal and dystrophin-lacking mdx mice
    • PMID:17510188
    • Gailly P, De Backer F, Van Schoor M, Gillis JM. In situ measurements of calpain activity in isolated muscle fibres from normal and dystrophin-lacking mdx mice. J Physiol 2007; 582:1261-75; PMID:17510188; http://dx.doi.org/10.1113/ jphysiol.2007.132191.
    • (2007) J Physiol , vol.582 , pp. 1261-1275
    • Gailly, P.1    De Backer, F.2    Van Schoor, M.3    Gillis, J.M.4
  • 24
    • 12744268414 scopus 로고    scopus 로고
    • Effects of stretch-activated channel blockers on [Ca2+]i and muscle damage in the mdx mouse
    • PMID:15528244
    • Yeung EW, Whitehead NP, Suchyna TM, Gottlieb PA, Sachs F, Allen DG. Effects of stretch-activated channel blockers on [Ca2+]i and muscle damage in the mdx mouse. J Physiol 2005; 562:367-80; PMID:15528244; http://dx.doi.org/10. 1113/jphysiol.2004.075275.
    • (2005) J Physiol , vol.562 , pp. 367-380
    • Yeung, E.W.1    Whitehead, N.P.2    Suchyna, T.M.3    Gottlieb, P.A.4    Sachs, F.5    Allen, D.G.6
  • 25
    • 77649297696 scopus 로고    scopus 로고
    • Hypoxia activates a Ca2+-permeable cation conductance sensitive to carbon monoxide and to GsMTx-4 in human and mouse sickle erythrocytes
    • PMID:20090940
    • Vandorpe DH, Xu C, Shmukler BE, Otterbein LE, Trudel M, Sachs F, et al. Hypoxia activates a Ca2+-permeable cation conductance sensitive to carbon monoxide and to GsMTx-4 in human and mouse sickle erythrocytes. PLoS One 2010; 5:8732; PMID:20090940; http://dx.doi.org/10.1371/journal.pone.0008732.
    • (2010) PLoS One , vol.5 , pp. 8732
    • Vandorpe, D.H.1    Xu, C.2    Shmukler, B.E.3    Otterbein, L.E.4    Trudel, M.5    Sachs, F.6
  • 26
    • 0030986861 scopus 로고    scopus 로고
    • Mechanical transduction by ion channels: How forces reach the channel
    • [Review] [52 refs]. PMID:9210231
    • Sachs F. Mechanical transduction by ion channels: how forces reach the channel. [Review] [52 refs]. Soc Gen Physiol Ser 1997; 52:209-18; PMID:9210231.
    • (1997) Soc Gen Physiol ser , vol.52 , pp. 209-218
    • Sachs, F.1
  • 27
    • 0034141771 scopus 로고    scopus 로고
    • Whole-cell mechanosensitive currents in rat ventricular myocytes activated by direct stimulation
    • PMID:10667920
    • Bett GCL, Sachs F. Whole-cell mechanosensitive currents in rat ventricular myocytes activated by direct stimulation. J Membr Biol 2000; 173:255-63; PMID:10667920; http://dx.doi.org/10.1007/s002320001024.
    • (2000) J Membr Biol , vol.173 , pp. 255-263
    • Bett, G.C.L.1    Sachs, F.2
  • 28
    • 76349102806 scopus 로고    scopus 로고
    • Stretch-activated ion channels: What are they?
    • (Bethesda) PMID:20134028
    • Sachs F. Stretch-activated ion channels: what are they? Physiology (Bethesda) 2010; 25:50-6; PMID:20134028; http://dx.doi.org/10.1152/physiol. 00042.2009.
    • (2010) Physiology , vol.25 , pp. 50-56
    • Sachs, F.1
  • 29
    • 43149122905 scopus 로고    scopus 로고
    • Endocytic pathways: Combined scanning ion conductance and surface confocal microscopy study
    • PMID:18180951
    • Shevchuk AI, Hobson P, Lab MJ, Klenerman D, Krauzewicz N, Korchev YE. Endocytic pathways: combined scanning ion conductance and surface confocal microscopy study. Pflugers Arch 2008; 456:227-35; PMID:18180951; http://dx.doi.org/10.1007/s00424-007-0410-4.
    • (2008) Pflugers Arch , vol.456 , pp. 227-235
    • Shevchuk, A.I.1    Hobson, P.2    Lab, M.J.3    Klenerman, D.4    Krauzewicz, N.5    Korchev, Y.E.6
  • 30
    • 0036812080 scopus 로고    scopus 로고
    • High-speed pressure clamp
    • PMID:12397401
    • Besch SR, Suchyna T, Sachs F. High-speed pressure clamp. Pflugers Arch 2002; 445:161-6; PMID:12397401; http://dx.doi.org/10.1007/s00424-002-0903-0.
    • (2002) Pflugers Arch , vol.445 , pp. 161-166
    • Besch, S.R.1    Suchyna, T.2    Sachs, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.