-
1
-
-
70349957086
-
-
Geneva: WHO, World Health Organization
-
World Health Organization Global status report on road safety: time for action 2009, Geneva: WHO, http://whqlibdoc.who.int/publications/2009/9789241563840_eng.pdf, World Health Organization.
-
(2009)
Global status report on road safety: time for action
-
-
-
2
-
-
0003413139
-
-
Chicago: American College of Surgeons, American College of Surgeons Committee on Trauma
-
American College of Surgeons Committee on Trauma Advanced Trauma Life Support (7th Edition) 2007, Chicago: American College of Surgeons, American College of Surgeons Committee on Trauma.
-
(2007)
Advanced Trauma Life Support (7th Edition)
-
-
-
4
-
-
0031906985
-
Out-of-hospital spinal immobilization: its effect on neurologic injury
-
10.1111/j.1553-2712.1998.tb02615.x, 9523928
-
Hauswald M, Ong G, Tandberg D, Omal Z. Out-of-hospital spinal immobilization: its effect on neurologic injury. Acad Emerg Med 1998, 5(3):214-219. 10.1111/j.1553-2712.1998.tb02615.x, 9523928.
-
(1998)
Acad Emerg Med
, vol.5
, Issue.3
, pp. 214-219
-
-
Hauswald, M.1
Ong, G.2
Tandberg, D.3
Omal, Z.4
-
5
-
-
75649130065
-
Spine immobilization in penetrating trauma: more harm than good?
-
Haut ER, Kalish BT, Efron DT, Haider AH, Stevens KA, Kieninger AN, Cornwell EE, Chang DC. Spine immobilization in penetrating trauma: more harm than good?. J Trauma-Injury Infect Crit Care 2010, 68(1):115-121.
-
(2010)
J Trauma-Injury Infect Crit Care
, vol.68
, Issue.1
, pp. 115-121
-
-
Haut, E.R.1
Kalish, B.T.2
Efron, D.T.3
Haider, A.H.4
Stevens, K.A.5
Kieninger, A.N.6
Cornwell, E.E.7
Chang, D.C.8
-
6
-
-
77951663823
-
Cervical spine motion during extrication: a pilot study
-
2691505, 19561822
-
Shafer JS, Naunheim RS. Cervical spine motion during extrication: a pilot study. West J Emerg Med 2009, 10(2):74-8. 2691505, 19561822.
-
(2009)
West J Emerg Med
, vol.10
, Issue.2
, pp. 74-78
-
-
Shafer, J.S.1
Naunheim, R.S.2
-
7
-
-
2542577921
-
Comparison of cervical spine motion during application among 4 rigid immobilization collars
-
419507, 15173864
-
James CY, Riemann BL, Munkasy BA, Joyner AB. Comparison of cervical spine motion during application among 4 rigid immobilization collars. J Athl Train 2004, 39(2):138-145. 419507, 15173864.
-
(2004)
J Athl Train
, vol.39
, Issue.2
, pp. 138-145
-
-
James, C.Y.1
Riemann, B.L.2
Munkasy, B.A.3
Joyner, A.B.4
-
8
-
-
36048971925
-
Range-of-motion restriction and craniofacial tissue-interface pressure from four cervical collars
-
10.1097/TA.0b013e3180487d0f, 17993960
-
Tescher AN, Rindflesch AB, Youdas JW, Jacobson TM, Downer LL, Miers AG, Basford JR, Cullinane DC, Stevens SR, Pankratz VS, Decker PA. Range-of-motion restriction and craniofacial tissue-interface pressure from four cervical collars. J Trauma 2007, 63(5):1120-1126. 10.1097/TA.0b013e3180487d0f, 17993960.
-
(2007)
J Trauma
, vol.63
, Issue.5
, pp. 1120-1126
-
-
Tescher, A.N.1
Rindflesch, A.B.2
Youdas, J.W.3
Jacobson, T.M.4
Downer, L.L.5
Miers, A.G.6
Basford, J.R.7
Cullinane, D.C.8
Stevens, S.R.9
Pankratz, V.S.10
Decker, P.A.11
-
9
-
-
70350676809
-
A comparison of three cervical immobilization devices
-
Hostler D, Colburn D, Seitz SR. A comparison of three cervical immobilization devices. Prehospital Emerg Care 2009, 13(2):256-260.
-
(2009)
Prehospital Emerg Care
, vol.13
, Issue.2
, pp. 256-260
-
-
Hostler, D.1
Colburn, D.2
Seitz, S.R.3
-
10
-
-
33744550589
-
Reproducibility of the measurement of active and passive cervical range of motion
-
Hoppenbrouwers M, Eckhardt M, Verkerk K, Verhagen A. Reproducibility of the measurement of active and passive cervical range of motion. J Manip Physiol Ther 2006, 29(5):363-367.
-
(2006)
J Manip Physiol Ther
, vol.29
, Issue.5
, pp. 363-367
-
-
Hoppenbrouwers, M.1
Eckhardt, M.2
Verkerk, K.3
Verhagen, A.4
-
11
-
-
3843116933
-
Spine-board transfer techniques and the unstable cervical spine
-
10.1097/01.BRS.0000116986.48166.D0, 15087809
-
Del Rossi G, Horodyski M, Heffernan TP, Powers ME, Siders R, Brunt D, Rechtine GR. Spine-board transfer techniques and the unstable cervical spine. Spine 2004, 29(7):E134-8. 10.1097/01.BRS.0000116986.48166.D0, 15087809.
-
(2004)
Spine
, vol.29
, Issue.7
-
-
Del Rossi, G.1
Horodyski, M.2
Heffernan, T.P.3
Powers, M.E.4
Siders, R.5
Brunt, D.6
Rechtine, G.R.7
-
12
-
-
0034989113
-
The stabilizing effects of different orthoses in the intact and unstable upper cervical spine: a cadaver study
-
Richter D, Latta L, Milne E, Varkarakis G, Biedermann L, Ekkernkamp A, Ostermann P. The stabilizing effects of different orthoses in the intact and unstable upper cervical spine: a cadaver study. J Trauma Inj, Infect Crit Care 2001, 50(5):848-854.
-
(2001)
J Trauma Inj, Infect Crit Care
, vol.50
, Issue.5
, pp. 848-854
-
-
Richter, D.1
Latta, L.2
Milne, E.3
Varkarakis, G.4
Biedermann, L.5
Ekkernkamp, A.6
Ostermann, P.7
-
13
-
-
67650300511
-
Cervical motion assessment using virtual reality
-
10.1097/BRS.0b013e31819b3254, 19404177
-
Sarig-Bahat H, Weiss PL, Laufer Y. Cervical motion assessment using virtual reality. Spine 2009, 34(10):1018-1024. 10.1097/BRS.0b013e31819b3254, 19404177.
-
(2009)
Spine
, vol.34
, Issue.10
, pp. 1018-1024
-
-
Sarig-Bahat, H.1
Weiss, P.L.2
Laufer, Y.3
-
14
-
-
78149257609
-
"The fly": a new clinical assessment and treatment method for deficits of movement control in the cervical spine: reliability and validity
-
10.1097/BRS.0b013e3181e7fc0a, 20975484
-
Kristjansson E, Oddsdottir GL. "The fly": a new clinical assessment and treatment method for deficits of movement control in the cervical spine: reliability and validity. Spine 2010, 35(23):E1298-305. 10.1097/BRS.0b013e3181e7fc0a, 20975484.
-
(2010)
Spine
, vol.35
, Issue.23
-
-
Kristjansson, E.1
Oddsdottir, G.L.2
-
15
-
-
26644437702
-
A comparison of head movement during back boarding by motorized spine-board and log-roll techniques
-
1250254, 16284635
-
Swartz EE, Nowak J, Shirley C, Decoster LC. A comparison of head movement during back boarding by motorized spine-board and log-roll techniques. J Athl Train 2005, 40(3):162-168. 1250254, 16284635.
-
(2005)
J Athl Train
, vol.40
, Issue.3
, pp. 162-168
-
-
Swartz, E.E.1
Nowak, J.2
Shirley, C.3
Decoster, L.C.4
-
16
-
-
31544458430
-
Comparison of the Ferno Scoop Stretcher with the long backboard for spinal immobilization
-
Krell JM, Mccoy MS, Sparto PJ, Fisher GL, Stoy WA, Hostler DP. Comparison of the Ferno Scoop Stretcher with the long backboard for spinal immobilization. Prehospital Emerg Care 2006, 10(1):46-51.
-
(2006)
Prehospital Emerg Care
, vol.10
, Issue.1
, pp. 46-51
-
-
Krell, J.M.1
Mccoy, M.S.2
Sparto, P.J.3
Fisher, G.L.4
Stoy, W.A.5
Hostler, D.P.6
-
17
-
-
51549121777
-
Cervical motion testing: methodology and clinical implications
-
Prushansky T, Dvir Z. Cervical motion testing: methodology and clinical implications. J Manip Physiol Ther 2008, 31(7):503-508.
-
(2008)
J Manip Physiol Ther
, vol.31
, Issue.7
, pp. 503-508
-
-
Prushansky, T.1
Dvir, Z.2
-
18
-
-
0036491461
-
A comparison of methods of evaluating cervical range of motion
-
Wolfenberger VA, Bui Q, Batenchuk DC. A comparison of methods of evaluating cervical range of motion. J Manip Physiol Ther 2002, 25(3):154-160.
-
(2002)
J Manip Physiol Ther
, vol.25
, Issue.3
, pp. 154-160
-
-
Wolfenberger, V.A.1
Bui, Q.2
Batenchuk, D.C.3
-
19
-
-
78751630294
-
Motion within the unstable cervical spine during patient maneuvering: the neck pivot-shift phenomenon
-
10.1097/TA.0b013e3181fd0ebf, 21217496
-
Lador R, Ben-Galim P, Hipp JA. Motion within the unstable cervical spine during patient maneuvering: the neck pivot-shift phenomenon. J Trauma 2011, 70(1):247-251. 10.1097/TA.0b013e3181fd0ebf, 21217496.
-
(2011)
J Trauma
, vol.70
, Issue.1
, pp. 247-251
-
-
Lador, R.1
Ben-Galim, P.2
Hipp, J.A.3
-
20
-
-
80052037622
-
Reliability of the universal and invented gravity goniometers in measuring active cervical range of motion in normal healthy subjects
-
Yankai A, Manosan P. Reliability of the universal and invented gravity goniometers in measuring active cervical range of motion in normal healthy subjects. Int J Appl Biomed Eng 2009, 2(1):49-53.
-
(2009)
Int J Appl Biomed Eng
, vol.2
, Issue.1
, pp. 49-53
-
-
Yankai, A.1
Manosan, P.2
-
21
-
-
77953391870
-
Reproducibility and validity of digital inclinometry for measuring cervical range of motion in normal subjects
-
Prushansky T, Deryi O, Jabarreen B. Reproducibility and validity of digital inclinometry for measuring cervical range of motion in normal subjects. Physiother Res Int 2010, 15(1):42-48.
-
(2010)
Physiother Res Int
, vol.15
, Issue.1
, pp. 42-48
-
-
Prushansky, T.1
Deryi, O.2
Jabarreen, B.3
-
22
-
-
33645788765
-
Criterion validity study of the cervical range of motion (CROM) device for rotational range of motion on healthy adults
-
Tousignant M, Smeesters C, Breton A, Breton E, Corriveau H. Criterion validity study of the cervical range of motion (CROM) device for rotational range of motion on healthy adults. J Orthop Sports Phys Ther 2006, 36(4):242-248.
-
(2006)
J Orthop Sports Phys Ther
, vol.36
, Issue.4
, pp. 242-248
-
-
Tousignant, M.1
Smeesters, C.2
Breton, A.3
Breton, E.4
Corriveau, H.5
-
23
-
-
77953463419
-
Validity and between-day reliability of the cervical range of motion (CROM) device
-
Audette I, Dumas J, Cote JN, De Serres S. Validity and between-day reliability of the cervical range of motion (CROM) device. J Orthop Sports Phys Ther 2010, 40(5):318-323.
-
(2010)
J Orthop Sports Phys Ther
, vol.40
, Issue.5
, pp. 318-323
-
-
Audette, I.1
Dumas, J.2
Cote, J.N.3
De Serres, S.4
-
24
-
-
77956397272
-
Comparison of methods of measuring active cervical range of motion
-
10.1097/BRS.0b013e3181cd6176, 20700085
-
Whitcroft KL, Massouh L, Amirfeyz R, Bannister G. Comparison of methods of measuring active cervical range of motion. Spine 2010, 35(19):E976-80. 10.1097/BRS.0b013e3181cd6176, 20700085.
-
(2010)
Spine
, vol.35
, Issue.19
-
-
Whitcroft, K.L.1
Massouh, L.2
Amirfeyz, R.3
Bannister, G.4
-
25
-
-
76449098901
-
A systematic review of reliability and validity studies of methods for measuring active and passive cervical range of motion
-
Williams MA, Mccarthy CJ, Chorti A, Cooke MW, Gates S. A systematic review of reliability and validity studies of methods for measuring active and passive cervical range of motion. J Manip Physiol Ther 2010, 33(2):138-155.
-
(2010)
J Manip Physiol Ther
, vol.33
, Issue.2
, pp. 138-155
-
-
Williams, M.A.1
Mccarthy, C.J.2
Chorti, A.3
Cooke, M.W.4
Gates, S.5
-
26
-
-
78751487958
-
Active cervical range of motion recovery following the rugby off-season
-
Lark S, McCarthy P. Active cervical range of motion recovery following the rugby off-season. J Sports Med Phys Fit 2010, 50(3):318-325.
-
(2010)
J Sports Med Phys Fit
, vol.50
, Issue.3
, pp. 318-325
-
-
Lark, S.1
McCarthy, P.2
-
27
-
-
79951862853
-
A comparison of neck movement in the soft cervical collar and rigid cervical brace in healthy subjects
-
Whitcroft KL, Massouh L, Amirfeyz R, Bannister GC. A comparison of neck movement in the soft cervical collar and rigid cervical brace in healthy subjects. J Manip Physiol Ther 2011, 34(2):119-122.
-
(2011)
J Manip Physiol Ther
, vol.34
, Issue.2
, pp. 119-122
-
-
Whitcroft, K.L.1
Massouh, L.2
Amirfeyz, R.3
Bannister, G.C.4
-
28
-
-
33846070553
-
Reduction in head and intervertebral motion provided by 7 contemporary cervical orthoses in 45 individuals
-
10.1097/01.brs.0000251019.24917.44, 17202874
-
Schneider AM, Hipp JA, Nguyen L, Reitman CA. Reduction in head and intervertebral motion provided by 7 contemporary cervical orthoses in 45 individuals. Spine 2007, 32(1):E1-6. 10.1097/01.brs.0000251019.24917.44, 17202874.
-
(2007)
Spine
, vol.32
, Issue.1
-
-
Schneider, A.M.1
Hipp, J.A.2
Nguyen, L.3
Reitman, C.A.4
-
29
-
-
49149119306
-
Assessment of the cervical range of motion over time, differences between results of the Flock of Birds and the EDI-320: a comparison between an electromagnetic tracking system and an electronic inclinometer
-
10.1016/j.math.2007.05.012, 17681865
-
Assink N, Bergman G, Knoester B, Winters JC, Dijkstra PU. Assessment of the cervical range of motion over time, differences between results of the Flock of Birds and the EDI-320: a comparison between an electromagnetic tracking system and an electronic inclinometer. Man Ther 2008, 13(5):450-455. 10.1016/j.math.2007.05.012, 17681865.
-
(2008)
Man Ther
, vol.13
, Issue.5
, pp. 450-455
-
-
Assink, N.1
Bergman, G.2
Knoester, B.3
Winters, J.C.4
Dijkstra, P.U.5
-
30
-
-
59449102782
-
Three-dimensional analysis of cervical spine motion: reliability of a computer assisted magnetic tracking device compared to inclinometer
-
10.1007/s00586-008-0853-0, 2899335, 19096884
-
Gelalis ID, Defrate LE, Stafilas KS, Pakos EE, Kang JD, Gilbertson LG. Three-dimensional analysis of cervical spine motion: reliability of a computer assisted magnetic tracking device compared to inclinometer. Eur Spine J 2009, 18(2):276-281. 10.1007/s00586-008-0853-0, 2899335, 19096884.
-
(2009)
Eur Spine J
, vol.18
, Issue.2
, pp. 276-281
-
-
Gelalis, I.D.1
Defrate, L.E.2
Stafilas, K.S.3
Pakos, E.E.4
Kang, J.D.5
Gilbertson, L.G.6
-
31
-
-
24944507601
-
Validation of the Spin-T goniometer, a cervical range of motion device
-
Agarwal S, Allison GT, Singer KP. Validation of the Spin-T goniometer, a cervical range of motion device. J Manip Physiol Ther 2005, 28(8):604-609.
-
(2005)
J Manip Physiol Ther
, vol.28
, Issue.8
, pp. 604-609
-
-
Agarwal, S.1
Allison, G.T.2
Singer, K.P.3
-
32
-
-
64049118222
-
Comparing cervical spine motion with different halo devices in a cadaveric cervical instability model
-
10.1097/BRS.0b013e3181920e7c, 19139664
-
Dipaola CP, Sawers A, Conrad BP, Horodyski M, Dipaola MJ, Del Rossi G, Rechtine G. Comparing cervical spine motion with different halo devices in a cadaveric cervical instability model. Spine 2009, 34(2):149-155. 10.1097/BRS.0b013e3181920e7c, 19139664.
-
(2009)
Spine
, vol.34
, Issue.2
, pp. 149-155
-
-
Dipaola, C.P.1
Sawers, A.2
Conrad, B.P.3
Horodyski, M.4
Dipaola, M.J.5
Del Rossi, G.6
Rechtine, G.7
-
33
-
-
74249120387
-
Cervical spine motion generated with manual versus Jackson table turning methods in a cadaveric c1-c2 global instability model
-
10.1097/BRS.0b013e3181b7eddb, 20010399
-
Dipaola CP, Conrad BP, Horodyski M, Dipaola MJ, Sawers A, Rechtine G. Cervical spine motion generated with manual versus Jackson table turning methods in a cadaveric c1-c2 global instability model. Spine 2009, 34(26):2912-2918. 10.1097/BRS.0b013e3181b7eddb, 20010399.
-
(2009)
Spine
, vol.34
, Issue.26
, pp. 2912-2918
-
-
Dipaola, C.P.1
Conrad, B.P.2
Horodyski, M.3
Dipaola, M.J.4
Sawers, A.5
Rechtine, G.6
-
34
-
-
79955749664
-
Removing a patient from the spine board: Is the lift and slide safer than the log roll?
-
10.1097/TA.0b013e31820ff2bc, 21610441
-
Horodyski M, Conrad BP, Del Rossi G, Dipaola CP, Rechtine G. Removing a patient from the spine board: Is the lift and slide safer than the log roll?. J Trauma 2011, 70(5):1282-1285. 10.1097/TA.0b013e31820ff2bc, 21610441.
-
(2011)
J Trauma
, vol.70
, Issue.5
, pp. 1282-1285
-
-
Horodyski, M.1
Conrad, B.P.2
Del Rossi, G.3
Dipaola, C.P.4
Rechtine, G.5
-
35
-
-
77951992918
-
Neck motion due to the halo-vest in prone and supine positions
-
Ivancic PC, Telles CJ. Neck motion due to the halo-vest in prone and supine positions. Spine 2010, 35(10):E400-6.
-
(2010)
Spine
, vol.35
, Issue.10
-
-
Ivancic, P.C.1
Telles, C.J.2
-
36
-
-
77955905934
-
Motion in the unstable cervical spine during hospital bed transfers
-
10.1097/TA.0b013e3181e89f58, 20699754
-
Conrad BP, Rechtine G, Weight M, Clarke J, Horodyski M. Motion in the unstable cervical spine during hospital bed transfers. J Trauma 2010, 69(2):432-436. 10.1097/TA.0b013e3181e89f58, 20699754.
-
(2010)
J Trauma
, vol.69
, Issue.2
, pp. 432-436
-
-
Conrad, B.P.1
Rechtine, G.2
Weight, M.3
Clarke, J.4
Horodyski, M.5
-
37
-
-
0042974005
-
Measuring range of active cervical rotation in a position of full head flexion using the three-dimensional Fastrak measurement system: an intratester reliability study
-
10.1016/S1356-689X(03)00009-2, 12909439
-
Amiri M, Jull G, Bullock-Saxton J. Measuring range of active cervical rotation in a position of full head flexion using the three-dimensional Fastrak measurement system: an intratester reliability study. Man Ther 2003, 8(3):176-9. 10.1016/S1356-689X(03)00009-2, 12909439.
-
(2003)
Man Ther
, vol.8
, Issue.3
, pp. 176-179
-
-
Amiri, M.1
Jull, G.2
Bullock-Saxton, J.3
-
38
-
-
4744341795
-
Motion generated in the unstable spine during hospital bed transfers
-
Rechtine G, Del Rossi G, Conrad B, Horodyski M. Motion generated in the unstable spine during hospital bed transfers. J Trauma-Inj Infect Crit Care 2004, 57(3):609-612.
-
(2004)
J Trauma-Inj Infect Crit Care
, vol.57
, Issue.3
, pp. 609-612
-
-
Rechtine, G.1
Del Rossi, G.2
Conrad, B.3
Horodyski, M.4
-
39
-
-
34548218634
-
Wireless orientation sensors: their suitability to measure head movement for neck pain assessment
-
10.1016/j.math.2006.07.005, 16971158
-
Jasiewicz JM, Treleaven J, Condie P, Jull G. Wireless orientation sensors: their suitability to measure head movement for neck pain assessment. Man Ther 2007, 12(4):380-385. 10.1016/j.math.2006.07.005, 16971158.
-
(2007)
Man Ther
, vol.12
, Issue.4
, pp. 380-385
-
-
Jasiewicz, J.M.1
Treleaven, J.2
Condie, P.3
Jull, G.4
|