메뉴 건너뛰기




Volumn 13, Issue 5, 2008, Pages 450-455

Assessment of the cervical range of motion over time, differences between results of the Flock of Birds and the EDI-320: A comparison between an electromagnetic tracking system and an electronic inclinometer

Author keywords

Assessment; Natural variation; Range of motion; Reliability

Indexed keywords

ADULT; ARTICLE; CERVICAL SPINE; CLINICAL ASSESSMENT; DEVICE; DIAGNOSTIC PROCEDURE; ELECTROMAGNETIC FIELD; FEMALE; HUMAN; HUMAN EXPERIMENT; INCLINOMETER; INTERMETHOD COMPARISON; JOINT FUNCTION; MALE; NORMAL HUMAN; PRIORITY JOURNAL; RANGE OF MOTION;

EID: 49149119306     PISSN: 1356689X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.math.2007.05.012     Document Type: Article
Times cited : (19)

References (16)
  • 3
    • 15244354998 scopus 로고    scopus 로고
    • Variation in the cervical range of motion over time measured by the "flock of birds" electromagnetic tracking system
    • Bergman G.J., Knoester B., Assink N., Dijkstra P.U., and Winters J.C. Variation in the cervical range of motion over time measured by the "flock of birds" electromagnetic tracking system. Spine 30 6 (2005) 650-654
    • (2005) Spine , vol.30 , Issue.6 , pp. 650-654
    • Bergman, G.J.1    Knoester, B.2    Assink, N.3    Dijkstra, P.U.4    Winters, J.C.5
  • 4
    • 0033855460 scopus 로고    scopus 로고
    • Biomechanics of the cervical spine. I: Normal kinematics
    • Bogduk N., and Mercer S. Biomechanics of the cervical spine. I: Normal kinematics. Clinical Biomechanics (Bristol, Avon) 15 9 (2000) 633-648
    • (2000) Clinical Biomechanics (Bristol, Avon) , vol.15 , Issue.9 , pp. 633-648
    • Bogduk, N.1    Mercer, S.2
  • 5
    • 0032776562 scopus 로고    scopus 로고
    • Meta-analysis of normative cervical motion
    • Chen J., Solinger A.B., Poncet J.F., and Lantz C.A. Meta-analysis of normative cervical motion. Spine 24 15 (1999) 1571-1578
    • (1999) Spine , vol.24 , Issue.15 , pp. 1571-1578
    • Chen, J.1    Solinger, A.B.2    Poncet, J.F.3    Lantz, C.A.4
  • 6
    • 0027505276 scopus 로고
    • Interrater reliability of the Cybex EDI-320 and fluid goniometer in normals and patients with low back pain
    • Chiarello C.M., and Savidge R. Interrater reliability of the Cybex EDI-320 and fluid goniometer in normals and patients with low back pain. Archives of Physical Medicine and Rehabilitation 74 1 (1993) 32-37
    • (1993) Archives of Physical Medicine and Rehabilitation , vol.74 , Issue.1 , pp. 32-37
    • Chiarello, C.M.1    Savidge, R.2
  • 8
    • 0034992226 scopus 로고    scopus 로고
    • 'Coupled motions' in cervical spine rotation can be misleading
    • Comment on V. Feipel, B. Rondelet, J.-P. Le Pallec, M. Rooze. Normal global motion of the cervical spine: an electrogoniometric study. Clinical Biomechanics (Bristol, Avon) 1999;14:462-70
    • Hof A.L., Koerhuis C.L., and Winters J.C. 'Coupled motions' in cervical spine rotation can be misleading. Comment on V. Feipel, B. Rondelet, J.-P. Le Pallec, M. Rooze. Normal global motion of the cervical spine: an electrogoniometric study. Clinical Biomechanics (Bristol, Avon) 1999;14:462-70. Clinical Biomechanics (Bristol, Avon) 16 5 (2001) 455-458
    • (2001) Clinical Biomechanics (Bristol, Avon) , vol.16 , Issue.5 , pp. 455-458
    • Hof, A.L.1    Koerhuis, C.L.2    Winters, J.C.3
  • 11
    • 4944264738 scopus 로고    scopus 로고
    • Zebris versus Myrin: a comparative study between a three-dimensional ultrasound movement analysis and an inclinometer/compass method: intradevice reliability, concurrent validity, intertester comparison, intratester reliability, and intraindividual variability
    • Malmstrom E.M., Karlberg M., Melander A., and Magnusson M. Zebris versus Myrin: a comparative study between a three-dimensional ultrasound movement analysis and an inclinometer/compass method: intradevice reliability, concurrent validity, intertester comparison, intratester reliability, and intraindividual variability. Spine 28 21 (2003) E433-E440
    • (2003) Spine , vol.28 , Issue.21
    • Malmstrom, E.M.1    Karlberg, M.2    Melander, A.3    Magnusson, M.4
  • 12
    • 0032920203 scopus 로고    scopus 로고
    • Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies
    • Meskers C.G., Fraterman H., van der Helm F.C., Vermeulen H.M., and Rozing P.M. Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies. Journal of Biomechanics 32 6 (1999) 629-633
    • (1999) Journal of Biomechanics , vol.32 , Issue.6 , pp. 629-633
    • Meskers, C.G.1    Fraterman, H.2    van der Helm, F.C.3    Vermeulen, H.M.4    Rozing, P.M.5
  • 15
    • 0035183012 scopus 로고    scopus 로고
    • Intratester and intertester reliability of the Cybex electronic digital inclinometer (EDI-320) for measurement of active neck flexion and extension in healthy subjects
    • Tousignant M., Boucher N., Bourbonnais J., Gravelle T., Quesnel M., and Brosseau L. Intratester and intertester reliability of the Cybex electronic digital inclinometer (EDI-320) for measurement of active neck flexion and extension in healthy subjects. Manual Therapy 6 4 (2001) 235-241
    • (2001) Manual Therapy , vol.6 , Issue.4 , pp. 235-241
    • Tousignant, M.1    Boucher, N.2    Bourbonnais, J.3    Gravelle, T.4    Quesnel, M.5    Brosseau, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.