메뉴 건너뛰기




Volumn 71-72, Issue , 2012, Pages 24-30

Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry

Author keywords

Analysis of silica; Graphite furnace atomic absorption spectrometry; Hazardous elements; Solid sampling

Indexed keywords

AMORPHOUS SILICA; ATOMIZATION TEMPERATURES; CALIBRATION CURVES; COST-EFFECTIVE ANALYSIS; DIRECT ANALYSIS; FAST SCREENING; FOOD INDUSTRIES; GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY; GRAPHITE POWDER; HAZARDOUS ELEMENTS; LEGAL REQUIREMENTS; LOW LIMITS OF DETECTIONS; SOLID SAMPLING; STANDARD SOLUTIONS; WORKING CONDITIONS;

EID: 84864465701     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2012.03.005     Document Type: Conference Paper
Times cited : (11)

References (40)
  • 2
    • 84894081173 scopus 로고    scopus 로고
    • Synthetic Amorphous Silica (CAS N°7631-86-9)
    • European Centre for Ecotoxicology and Toxicology of Chemicals Brussels
    • Synthetic Amorphous Silica (CAS N°7631-86-9) Joint Assessment of Commodity Chemicals Report N°51 2006 European Centre for Ecotoxicology and Toxicology of Chemicals Brussels 1 237
    • (2006) Joint Assessment of Commodity Chemicals Report N°51 , pp. 1-237
  • 3
    • 80053004131 scopus 로고    scopus 로고
    • 7th ed. United Book Press Inc Baltimore
    • Food Chemicals Codex 7th ed. 2010 United Book Press Inc Baltimore
    • (2010) Food Chemicals Codex
  • 8
    • 0029539533 scopus 로고
    • An objective assessment of analytical method precision: Comparison of ICP-AES and XRF for the analysis of silicate rocks
    • M.H. Ramsey, P.J. Potts, P.C. Webb, P. Watkins, J.S. Watson, and B.J. Coles An objective assessment of analytical method precision: comparison of ICP-AES and XRF for the analysis of silicate rocks Chem. Geol. 124 1995 1 19
    • (1995) Chem. Geol. , vol.124 , pp. 1-19
    • Ramsey, M.H.1    Potts, P.J.2    Webb, P.C.3    Watkins, P.4    Watson, J.S.5    Coles, B.J.6
  • 9
    • 0030302375 scopus 로고    scopus 로고
    • Determination of trace elements in silicate rocks by X-ray fluorescence spectrometry on 1:5 glass discs: Comparison of accuracy and precision with pressed powder pellet analysis
    • J. Enzweiler, and P.C. Webb Determination of trace elements in silicate rocks by X-ray fluorescence spectrometry on 1:5 glass discs: comparison of accuracy and precision with pressed powder pellet analysis Chem. Geol. 130 1996 195 202
    • (1996) Chem. Geol. , vol.130 , pp. 195-202
    • Enzweiler, J.1    Webb, P.C.2
  • 12
    • 36649022068 scopus 로고    scopus 로고
    • Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
    • B. Welz, M.G.R. Vale, D.L.G. Borges, and U. Heitmann Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry Anal. Bioanal. Chem. 389 2007 2085 2095
    • (2007) Anal. Bioanal. Chem. , vol.389 , pp. 2085-2095
    • Welz, B.1    Vale, M.G.R.2    Borges, D.L.G.3    Heitmann, U.4
  • 13
    • 0036903394 scopus 로고    scopus 로고
    • Direct solid sampling with electrothermal atomization/vaporization. What for and how?
    • M.A. Belarra, M. Resano, F. Vanhaecke, and L. Moens Direct solid sampling with electrothermal atomization/vaporization. What for and how? Trends Anal. Chem. 21 2002 828 839
    • (2002) Trends Anal. Chem. , vol.21 , pp. 828-839
    • Belarra, M.A.1    Resano, M.2    Vanhaecke, F.3    Moens, L.4
  • 14
    • 33745253401 scopus 로고    scopus 로고
    • Current status of direct solid sampling for electrothermal atomic absorption spectrometry - A critical review of the development between 1995 and 2005
    • M.G.R. Vale, N. Oleszczuk, and W.N.L. dos Santos Current status of direct solid sampling for electrothermal atomic absorption spectrometry - A critical review of the development between 1995 and 2005 Appl. Spectrosc. Rev. 41 2006 377 400
    • (2006) Appl. Spectrosc. Rev. , vol.41 , pp. 377-400
    • Vale, M.G.R.1    Oleszczuk, N.2    Dos Santos, W.N.L.3
  • 15
    • 54949083109 scopus 로고    scopus 로고
    • Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry - A critical review with focus on solid sampling and slurry analysis
    • M. Resano, F. Vanhaecke, and M.T.C. de Loos-Vollebregt Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry - a critical review with focus on solid sampling and slurry analysis J. Anal. At. Spectrom. 23 2008 1450 1475
    • (2008) J. Anal. At. Spectrom. , vol.23 , pp. 1450-1475
    • Resano, M.1    Vanhaecke, F.2    De Loos-Vollebregt, M.T.C.3
  • 16
    • 33745125748 scopus 로고    scopus 로고
    • Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of silver at trace and ultratrace levels
    • M. Resano, M. Aramendía, E. Garcia-Ruiz, C. Crespo, and M.A. Belarra Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of silver at trace and ultratrace levels Anal. Chim. Acta 571 2006 142 149
    • (2006) Anal. Chim. Acta , vol.571 , pp. 142-149
    • Resano, M.1    Aramendía, M.2    Garcia-Ruiz, E.3    Crespo, C.4    Belarra, M.A.5
  • 17
    • 0142061177 scopus 로고    scopus 로고
    • Direct determination of cobalt and zinc in samples of different volatility by means of solid sampling - Graphite furnace atomic absorption spectrometry
    • M.A. Belarra, C. Crespo, M.P. Martínez-Garbayo, and M. Resano Direct determination of cobalt and zinc in samples of different volatility by means of solid sampling - graphite furnace atomic absorption spectrometry Spectrochim. Acta Part B 58 2003 1847 1858
    • (2003) Spectrochim. Acta Part B , vol.58 , pp. 1847-1858
    • Belarra, M.A.1    Crespo, C.2    Martínez-Garbayo, M.P.3    Resano, M.4
  • 18
    • 79651471514 scopus 로고    scopus 로고
    • A study of the direct determination of Cd, Cr, Cu, Pb and Zn in certified reference materials of soils by solid sampling electrothermal atomic absorption spectrometry
    • P. Török, and M. Žemberyová A study of the direct determination of Cd, Cr, Cu, Pb and Zn in certified reference materials of soils by solid sampling electrothermal atomic absorption spectrometry Spectrochim. Acta Part B 66 2011 93 97
    • (2011) Spectrochim. Acta Part B , vol.66 , pp. 93-97
    • Török, P.1    Žemberyová, M.2
  • 19
    • 77951139871 scopus 로고    scopus 로고
    • 2 modifiers for the direct determination of As and Sb in soils, sewage sludge and sediments by solid sampling electrothermal atomic absorption spectrometry
    • 2 modifiers for the direct determination of As and Sb in soils, sewage sludge and sediments by solid sampling electrothermal atomic absorption spectrometry Spectrochim. Acta Part B 65 2010 291 296
    • (2010) Spectrochim. Acta Part B , vol.65 , pp. 291-296
    • Török, P.1    Žemberyová, M.2
  • 20
    • 70350710042 scopus 로고    scopus 로고
    • Determination of silver in geological samples using high-resolution continuum source electrothermal atomic absorption spectrometry and direct solid sampling
    • I.M. Dittert, D.L.G. Borges, B. Welz, A.J. Curtius, and H. Becker-Ross Determination of silver in geological samples using high-resolution continuum source electrothermal atomic absorption spectrometry and direct solid sampling Microchim. Acta 167 2009 1 6
    • (2009) Microchim. Acta , vol.167 , pp. 1-6
    • Dittert, I.M.1    Borges, D.L.G.2    Welz, B.3    Curtius, A.J.4    Becker-Ross, H.5
  • 21
    • 34548650576 scopus 로고    scopus 로고
    • Determination of cadmium, copper and lead in alumina based catalysts by direct solid sampling graphite furnace atomic absorption spectrometry
    • L.F. Rodrigues, J.C.P. de Mattos, V.L. Dressler, D. Pozebon, and E.M.M. Flores Determination of cadmium, copper and lead in alumina based catalysts by direct solid sampling graphite furnace atomic absorption spectrometry Spectrochim. Acta Part B 62 2007 933 938
    • (2007) Spectrochim. Acta Part B , vol.62 , pp. 933-938
    • Rodrigues, L.F.1    De Mattos, J.C.P.2    Dressler, V.L.3    Pozebon, D.4    Flores, E.M.M.5
  • 22
    • 35448998902 scopus 로고    scopus 로고
    • Chromium determination in pharmaceutical grade barium sulfate by solid sampling electrothermal atomic absorption spectrometry with Zeeman-effect background correction
    • R.C. Bolzan, L.F. Rodrigues, J.C.P. de Mattos, V.L. Dressler, and E.M.M. Flores Chromium determination in pharmaceutical grade barium sulfate by solid sampling electrothermal atomic absorption spectrometry with Zeeman-effect background correction Talanta 74 2007 119 124
    • (2007) Talanta , vol.74 , pp. 119-124
    • Bolzan, R.C.1    Rodrigues, L.F.2    De Mattos, J.C.P.3    Dressler, V.L.4    Flores, E.M.M.5
  • 23
    • 0036007346 scopus 로고    scopus 로고
    • Control of spectral and non-spectral interferences in the determination of thallium in river and marine sediments using solid sampling electrothermal atomic absorption spectrometry
    • M.G.R. Vale, M.M. Silva, B. Welz, and R. Nowka Control of spectral and non-spectral interferences in the determination of thallium in river and marine sediments using solid sampling electrothermal atomic absorption spectrometry J. Anal. At. Spectrom. 17 2002 38 45
    • (2002) J. Anal. At. Spectrom. , vol.17 , pp. 38-45
    • Vale, M.G.R.1    Silva, M.M.2    Welz, B.3    Nowka, R.4
  • 24
    • 0030189812 scopus 로고    scopus 로고
    • Solution and slurry sampling electrothermal atomic absorption spectrometry for the analysis of high purity quartz
    • S. Hauptkorn, and V. Krivan Solution and slurry sampling electrothermal atomic absorption spectrometry for the analysis of high purity quartz Spectrochim. Acta Part B 51 1996 1197 1210
    • (1996) Spectrochim. Acta Part B , vol.51 , pp. 1197-1210
    • Hauptkorn, S.1    Krivan, V.2
  • 25
    • 79451474142 scopus 로고    scopus 로고
    • High-resolution continuum source graphite furnace atomic absorption spectrometry: Is it as good as it sounds? A critical review
    • M. Resano, and E. García-Ruiz High-resolution continuum source graphite furnace atomic absorption spectrometry: Is it as good as it sounds? A critical review Anal. Bioanal. Chem. 399 2011 323 330
    • (2011) Anal. Bioanal. Chem. , vol.399 , pp. 323-330
    • Resano, M.1    García-Ruiz, E.2
  • 28
    • 0032681865 scopus 로고    scopus 로고
    • Theoretical evaluation of solid sampling-electrothermal atomic absorption spectrometry for screening purposes
    • M.A. Belarra, M. Resano, and J.R. Castillo Theoretical evaluation of solid sampling-electrothermal atomic absorption spectrometry for screening purposes J. Anal. At. Spectrom. 14 1999 547 552
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 547-552
    • Belarra, M.A.1    Resano, M.2    Castillo, J.R.3
  • 29
    • 4344645971 scopus 로고    scopus 로고
    • Evaluation of solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry and solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Cr in various materials using solution- based calibration approaches
    • M. Resano, E. Garcia-Ruiz, F. Vanhaecke, C. Crespo, and M.A. Belarra Evaluation of solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry and solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Cr in various materials using solution- based calibration approaches J. Anal. At. Spectrom. 19 2004 958 965
    • (2004) J. Anal. At. Spectrom. , vol.19 , pp. 958-965
    • Resano, M.1    Garcia-Ruiz, E.2    Vanhaecke, F.3    Crespo, C.4    Belarra, M.A.5
  • 30
    • 0034227308 scopus 로고    scopus 로고
    • Direct determination of copper and lead in sewage sludge by solid sampling-graphite furnace atomic absorption spectrometry-study of the interference reduction in the gaseous phase working in non-stop flow conditions
    • M.A. Belarra, C. Crespo, M. Resano, and J.R. Castillo Direct determination of copper and lead in sewage sludge by solid sampling-graphite furnace atomic absorption spectrometry-study of the interference reduction in the gaseous phase working in non-stop flow conditions Spectrochim. Acta Part B 55 2000 865 874
    • (2000) Spectrochim. Acta Part B , vol.55 , pp. 865-874
    • Belarra, M.A.1    Crespo, C.2    Resano, M.3    Castillo, J.R.4
  • 31
    • 33845679058 scopus 로고    scopus 로고
    • Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissues
    • M. Resano, J. Briceño, M. Aramendía, and M.A. Belarra Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissues Anal. Chim. Acta 582 2007 214 222
    • (2007) Anal. Chim. Acta , vol.582 , pp. 214-222
    • Resano, M.1    Briceño, J.2    Aramendía, M.3    Belarra, M.A.4
  • 32
    • 18844410857 scopus 로고    scopus 로고
    • Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Au in samples of various natures
    • M. Resano, M. Aramendía, E. Garcia-Ruiz, and M.A. Belarra Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Au in samples of various natures J. Anal. At. Spectrom. 20 2005 479 481
    • (2005) J. Anal. At. Spectrom. , vol.20 , pp. 479-481
    • Resano, M.1    Aramendía, M.2    Garcia-Ruiz, E.3    Belarra, M.A.4
  • 33
    • 0346906966 scopus 로고    scopus 로고
    • Solid sampling-graphite furnace atomic absorption spectrometry for palladium determination at trace and ultratrace levels
    • M. Resano, E. Garcia-Ruiz, C. Crespo, F. Vanhaecke, and M.A. Belarra Solid sampling-graphite furnace atomic absorption spectrometry for palladium determination at trace and ultratrace levels J. Anal. At. Spectrom. 18 2003 1477 1484
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 1477-1484
    • Resano, M.1    Garcia-Ruiz, E.2    Crespo, C.3    Vanhaecke, F.4    Belarra, M.A.5
  • 34
    • 77950627778 scopus 로고    scopus 로고
    • Simultaneous determination of Cd and Fe in sewage sludge by high-resolution continuum source electrothermal atomic absorption spectrometry with slurry sampling
    • F. Vignola, D.L.G. Borges, A.J. Curtius, B. Welz, and H. Becker-Ross Simultaneous determination of Cd and Fe in sewage sludge by high-resolution continuum source electrothermal atomic absorption spectrometry with slurry sampling Microchem. J. 95 2010 333 336
    • (2010) Microchem. J. , vol.95 , pp. 333-336
    • Vignola, F.1    Borges, D.L.G.2    Curtius, A.J.3    Welz, B.4    Becker-Ross, H.5
  • 35
    • 47249092276 scopus 로고    scopus 로고
    • Determination of trace elements in aquatic plants by means of solid sampling Zeeman atomic absorption spectrometry (SS-ZAAS)
    • A. Detcheva, and K.H. Grobecker Determination of trace elements in aquatic plants by means of solid sampling Zeeman atomic absorption spectrometry (SS-ZAAS) Environ. Chem. Lett. 6 2008 183 187
    • (2008) Environ. Chem. Lett. , vol.6 , pp. 183-187
    • Detcheva, A.1    Grobecker, K.H.2
  • 36
    • 0035980207 scopus 로고    scopus 로고
    • Determination of cadmium, copper and lead in mineral coal using solid sampling graphite furnace atomic absorption spectrometry
    • M.G.R. Vale, M.M. Silva, B. Welz, and É.C. Lima Determination of cadmium, copper and lead in mineral coal using solid sampling graphite furnace atomic absorption spectrometry Spectrochim. Acta Part B 56 2001 1859 1873
    • (2001) Spectrochim. Acta Part B , vol.56 , pp. 1859-1873
    • Vale, M.G.R.1    Silva, M.M.2    Welz, B.3    Lima, É.C.4
  • 37
    • 0033329804 scopus 로고    scopus 로고
    • The use of chemical modifiers in the determination of cadmium in sewage sludge and tin in PVC by solid sampling-graphite furnace atomic absorption spectrometry
    • M.A. Belarra, M. Resano, S. Rodríguez, J. Urchaga, and J.R. Castillo The use of chemical modifiers in the determination of cadmium in sewage sludge and tin in PVC by solid sampling-graphite furnace atomic absorption spectrometry Spectrochim. Acta Part B 54 1999 787 795
    • (1999) Spectrochim. Acta Part B , vol.54 , pp. 787-795
    • Belarra, M.A.1    Resano, M.2    Rodríguez, S.3    Urchaga, J.4    Castillo, J.R.5
  • 38
    • 0034252433 scopus 로고    scopus 로고
    • Rapid determination of lead and cadmium in sewage sludge samples using electrothermal atomic absorption spectrometry with slurry sample introduction
    • I. López-García, P. Viñas, J. Arroyo-Cortéz, and M. Hernández-Córdoba Rapid determination of lead and cadmium in sewage sludge samples using electrothermal atomic absorption spectrometry with slurry sample introduction Fresenius J. Anal. Chem. 367 2000 727 732
    • (2000) Fresenius J. Anal. Chem. , vol.367 , pp. 727-732
    • López-García, I.1    Viñas, P.2    Arroyo-Cortéz, J.3    Hernández-Córdoba, M.4
  • 39
    • 0032178727 scopus 로고    scopus 로고
    • Solid sampling electrothermal atomic absorption spectrometry for analysis of aluminium oxide powders
    • M. Lucic, and V. Krivan Solid sampling electrothermal atomic absorption spectrometry for analysis of aluminium oxide powders J. Anal. At. Spectrom. 13 1998 1133 1139
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 1133-1139
    • Lucic, M.1    Krivan, V.2
  • 40
    • 28944440138 scopus 로고    scopus 로고
    • Solid sampling-graphite furnace atomic absorption spectrometry for Hg monitoring in soils. Performance as a quantitative and as a screening method
    • M. Resano, E. García-Ruiz, M. Aramendía, and M.A. Belarra Solid sampling-graphite furnace atomic absorption spectrometry for Hg monitoring in soils. Performance as a quantitative and as a screening method J. Anal. At. Spectrom. 20 2005 1374 1390
    • (2005) J. Anal. At. Spectrom. , vol.20 , pp. 1374-1390
    • Resano, M.1    García-Ruiz, E.2    Aramendía, M.3    Belarra, M.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.