Volumn , Issue , 2012, Pages 1546-1550

Systematic distance deviation error compensation for a ToF-camera in the close-up range

Author keywords

high resolution; optical distance measurement component; Phase measurement; phase shift algorithm; photonic mixer devices (PMD); time of flight (TOF)

Indexed keywords

HIGH RESOLUTION; OPTICAL DISTANCE MEASUREMENTS; PHASE SHIFT ALGORITHMS; PHOTONIC MIXER DEVICE; TIME OF FLIGHT;

EID: 84864272658     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/I2MTC.2012.6229118     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 4
    • 0031329024 scopus 로고    scopus 로고
    • New electro-optical mixing and correlating sensor: Facilities and applications of the photonic mixer device (PMD)
    • R. Schwarte, Z. Xu, H. Heinol, J. Olk, R. Klein, B. Buxbaum, H. Fischer and J. Schulte, "New electro-optical mixing and correlating sensor: facilities and applications of the photonic mixer device (PMD)," in Proc. SPIE, vol. 3100, pp. 245-53, 1997.
    • (1997) Proc. SPIE , vol.3100 , pp. 245-253
    • Schwarte, R.1    Xu, Z.2    Heinol, H.3    Olk, J.4    Klein, R.5    Buxbaum, B.6    Fischer, H.7    Schulte, J.8
  • 6
    • 0035279429 scopus 로고    scopus 로고
    • Solid-state time-of-flight range camera
    • Robert Lange and Peter Seitz, "Solid-state time-of-flight range camera," IEEE Journal of Quantum Electronics, vol. 37, no. 3, pp. 390-397, 2001.
    • (2001) IEEE Journal of Quantum Electronics , vol.37 , Issue.3 , pp. 390-397
    • Lange, R.1    Seitz, P.2
  • 9
    • 33845425129 scopus 로고    scopus 로고
    • Lateral and depth calibration of PMD distance sensors
    • Springer
    • M. Lindner and A. Kolb, "Lateral and depth calibration of PMD distance sensors," in Int. Symp. on Visual Computing (ISVC), 2, pp. 524-533, Springer, 2006.
    • (2006) Int. Symp. on Visual Computing (ISVC) , vol.2 , pp. 524-533
    • Lindner, M.1    Kolb, A.2
  • 10
    • 42449138396 scopus 로고    scopus 로고
    • Calibration of the intensity-related distance error of the PMD TOF-camera lateral and depth calibration of PMD distance sensors
    • M. Lindner and A. Kolb, "Calibration of the Intensity-Related Distance Error of the PMD TOF-Camera Lateral and depth calibration of PMD distance sensors," in Proc.SPIE, Intelligent Robots and Computer Vision, volume 6764, pages 6764-35, 2007.
    • (2007) Proc.SPIE, Intelligent Robots and Computer Vision , vol.6764 , pp. 6764-6835
    • Lindner, M.1    Kolb, A.2