메뉴 건너뛰기




Volumn 70, Issue 4, 2012, Pages 204-212

Schools, office buildings, leisure settings: Diversity of indoor air quality issues. Global review on indoor air quality in these settings;Écoles, bureaux, espaces de loisirs : Des lieux de vie variés, des pollutions intérieures contrastées. Revue générale des connaissances disponibles sur la qualité de l'air dans ces espaces

Author keywords

Ice rink; Indoor air quality; Office; School; Sport hall; Swimming pool

Indexed keywords

ICE;

EID: 84864111877     PISSN: 00034509     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.pharma.2012.06.003     Document Type: Review
Times cited : (10)

References (71)
  • 4
    • 56349108195 scopus 로고    scopus 로고
    • Characterization of indoor air quality in primary schools in Antwerp, Belgium
    • Stranger M., Potgieter-Vermaak S.S., Van Grieken R. Characterization of indoor air quality in primary schools in Antwerp, Belgium. Indoor Air 2008, 18:454-463.
    • (2008) Indoor Air , vol.18 , pp. 454-463
    • Stranger, M.1    Potgieter-Vermaak, S.S.2    Van Grieken, R.3
  • 5
    • 84872204514 scopus 로고    scopus 로고
    • Binnenlucht in Basisscholen (BIBA). Contract 071571. VITO, Mol, 2010. 251 pages.
    • Binnenlucht in Basisscholen (BIBA). Contract 071571. VITO, Mol, 2010. 251 pages.
  • 9
    • 77953098030 scopus 로고    scopus 로고
    • Phthalate and PAH concentrations in dust collected from Danish homes and daycare centers
    • Langer S., Weschler C.J., Fischer A. Phthalate and PAH concentrations in dust collected from Danish homes and daycare centers. Atmos Environ 2010, 44:2294-2301.
    • (2010) Atmos Environ , vol.44 , pp. 2294-2301
    • Langer, S.1    Weschler, C.J.2    Fischer, A.3
  • 10
    • 77952922463 scopus 로고    scopus 로고
    • Dust from U.K. primary school classrooms and daycare centers: the significance of dust as a pathway of exposure of young U.K. children to brominated flame retardants and polychlorinated biphenyls
    • Harrad S., Goosey E., Desborough J., Abdallah M.A.E., Roosens L., Covaci A. Dust from U.K. primary school classrooms and daycare centers: the significance of dust as a pathway of exposure of young U.K. children to brominated flame retardants and polychlorinated biphenyls. Environ Sci Technol 2010, 44:4198-4202.
    • (2010) Environ Sci Technol , vol.44 , pp. 4198-4202
    • Harrad, S.1    Goosey, E.2    Desborough, J.3    Abdallah, M.A.E.4    Roosens, L.5    Covaci, A.6
  • 11
    • 77954019073 scopus 로고    scopus 로고
    • Distribution and fate of polybrominated diphenyl ethers in indoor environments of elementary schools
    • Wu Q., Baek S.Y., Fang M., Chang Y.S. Distribution and fate of polybrominated diphenyl ethers in indoor environments of elementary schools. Indoor Air 2010, 20:263-270.
    • (2010) Indoor Air , vol.20 , pp. 263-270
    • Wu, Q.1    Baek, S.Y.2    Fang, M.3    Chang, Y.S.4
  • 12
    • 54049109926 scopus 로고    scopus 로고
    • Pyrethroid pesticides and their metabolites in vacuum cleaner dust collected from homes and day-care centers
    • Starr J., Graham S., Stout D., Andrews K., Nishioka M. Pyrethroid pesticides and their metabolites in vacuum cleaner dust collected from homes and day-care centers. Environ Res 2008, 108:271-279.
    • (2008) Environ Res , vol.108 , pp. 271-279
    • Starr, J.1    Graham, S.2    Stout, D.3    Andrews, K.4    Nishioka, M.5
  • 13
    • 78349306564 scopus 로고    scopus 로고
    • Perfluoroalkyl compounds in dust from Asian, Australian, European, and North American homes and UK cars, classrooms, and offices
    • Goosey E., Harrad S. Perfluoroalkyl compounds in dust from Asian, Australian, European, and North American homes and UK cars, classrooms, and offices. Environ Int 2011, 37:86-92.
    • (2011) Environ Int , vol.37 , pp. 86-92
    • Goosey, E.1    Harrad, S.2
  • 14
    • 79958245984 scopus 로고    scopus 로고
    • Levels and congener profiles among teachers in PCB-containing schools: a pilot study
    • Herrick R.F., Meeker J.D., Altshul L., Serum PCB levels and congener profiles among teachers in PCB-containing schools: a pilot study. Environ Health 2011, 10:56.
    • (2011) Environ Health , vol.10 , pp. 56
    • Herrick, R.F.1    Meeker, J.D.2    Altshul, L.3    Serum, P.C.B.4
  • 15
    • 51849098447 scopus 로고    scopus 로고
    • Particle size distribution and composition in a mechanically ventilated school building during air pollution episodes
    • Parker J.L., Larson R.R., Eskelson E., Wood E.M., Veranth J.M. Particle size distribution and composition in a mechanically ventilated school building during air pollution episodes. Indoor Air 2008, 18:386-393.
    • (2008) Indoor Air , vol.18 , pp. 386-393
    • Parker, J.L.1    Larson, R.R.2    Eskelson, E.3    Wood, E.M.4    Veranth, J.M.5
  • 16
    • 38649124011 scopus 로고    scopus 로고
    • Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom
    • Guo H., Morawska L., He C., Gilbert D. Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom. Atmos Environ 2008, 42:757-768.
    • (2008) Atmos Environ , vol.42 , pp. 757-768
    • Guo, H.1    Morawska, L.2    He, C.3    Gilbert, D.4
  • 18
    • 57449121461 scopus 로고    scopus 로고
    • Particulate matter and carbon dioxide in classrooms - the impact of cleaning and ventilation
    • Heudorf U., Neitzert V., Spark J. Particulate matter and carbon dioxide in classrooms - the impact of cleaning and ventilation. Int J Hyg Environ Health 2009, 212:45-55.
    • (2009) Int J Hyg Environ Health , vol.212 , pp. 45-55
    • Heudorf, U.1    Neitzert, V.2    Spark, J.3
  • 19
    • 39749138929 scopus 로고    scopus 로고
    • Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: model development and evaluation
    • Weichental S., Dufresne A., Infante-Rivard C., Joseph L. Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: model development and evaluation. Environ Res 2008, 106:349-360.
    • (2008) Environ Res , vol.106 , pp. 349-360
    • Weichental, S.1    Dufresne, A.2    Infante-Rivard, C.3    Joseph, L.4
  • 20
    • 78650910584 scopus 로고    scopus 로고
    • Ultrafine particle concentrations and exposures in six elementary school classrooms in northern California
    • Mullen N.A., Bhangar S., Hering S.V., Kreisberg N.M., Nazaroff W.W. Ultrafine particle concentrations and exposures in six elementary school classrooms in northern California. Indoor Air 2011, 21:77-87.
    • (2011) Indoor Air , vol.21 , pp. 77-87
    • Mullen, N.A.1    Bhangar, S.2    Hering, S.V.3    Kreisberg, N.M.4    Nazaroff, W.W.5
  • 21
    • 72849149529 scopus 로고    scopus 로고
    • Ultrafine particles in indoor air of a school: possible role of secondary organic aerosols
    • Morawska L., He C., Johnson G., Guo H., Uhde E., Ayoko G. Ultrafine particles in indoor air of a school: possible role of secondary organic aerosols. Environ Sci Technol 2009, 43:9103-9109.
    • (2009) Environ Sci Technol , vol.43 , pp. 9103-9109
    • Morawska, L.1    He, C.2    Johnson, G.3    Guo, H.4    Uhde, E.5    Ayoko, G.6
  • 22
    • 47549109830 scopus 로고    scopus 로고
    • Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation
    • Santamouris M., Synnefa A., Asssimakopoulos M., Livada I., Pavlou K., Papaglastra M., et al. Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation. Energy Build 2008, 40:1833-1843.
    • (2008) Energy Build , vol.40 , pp. 1833-1843
    • Santamouris, M.1    Synnefa, A.2    Asssimakopoulos, M.3    Livada, I.4    Pavlou, K.5    Papaglastra, M.6
  • 23
    • 80052629265 scopus 로고    scopus 로고
    • Respiratory symptoms, perceived air quality and physiological signs in elementary school pupils in relation to displacement and mixing ventilation system: an intervention study
    • Norbäck D., Wieslander G., Zhang X., Zhao Z. Respiratory symptoms, perceived air quality and physiological signs in elementary school pupils in relation to displacement and mixing ventilation system: an intervention study. Indoor Air 2011, 21:427-437.
    • (2011) Indoor Air , vol.21 , pp. 427-437
    • Norbäck, D.1    Wieslander, G.2    Zhang, X.3    Zhao, Z.4
  • 24
    • 52049114637 scopus 로고    scopus 로고
    • Comparing the effectiveness of interventions to improve ventilation behavior in primary schools
    • Geelen L.M., Huijbregts M.A., Ragas A.M., Bretveld R.W., Jans H.W., van Doorn W.J., et al. Comparing the effectiveness of interventions to improve ventilation behavior in primary schools. Indoor Air 2008, 18:416-424.
    • (2008) Indoor Air , vol.18 , pp. 416-424
    • Geelen, L.M.1    Huijbregts, M.A.2    Ragas, A.M.3    Bretveld, R.W.4    Jans, H.W.5    van Doorn, W.J.6
  • 25
    • 84863409527 scopus 로고    scopus 로고
    • Aircraft noise, overheating and poor air quality in classrooms in London primary schools
    • Montazani A., Wilson M., Nicol F. Aircraft noise, overheating and poor air quality in classrooms in London primary schools. Build Environ 2012, 52:129-141.
    • (2012) Build Environ , vol.52 , pp. 129-141
    • Montazani, A.1    Wilson, M.2    Nicol, F.3
  • 26
    • 61349122017 scopus 로고    scopus 로고
    • Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England
    • Mumovic D., Palmer J., Davies M., Orme M., Ridley I., Oreszczyn T., et al. Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England. Build Environ 2009, 44:1466-1477.
    • (2009) Build Environ , vol.44 , pp. 1466-1477
    • Mumovic, D.1    Palmer, J.2    Davies, M.3    Orme, M.4    Ridley, I.5    Oreszczyn, T.6
  • 28
    • 84872220162 scopus 로고    scopus 로고
    • SEARCH. International research project report.
    • Csobod E, Rudnai P, Vaskovi E. SEARCH. International research project report.
    • Csobod, E.1    Rudnai, P.2    Vaskovi, E.3
  • 30
    • 67651222110 scopus 로고    scopus 로고
    • Indoor allergens in school and day care environments
    • Salo P.M., Sever M.L., Zeldin D.C. Indoor allergens in school and day care environments. J Allergy Clin Immunol 2009, 124:185-192.
    • (2009) J Allergy Clin Immunol , vol.124 , pp. 185-192
    • Salo, P.M.1    Sever, M.L.2    Zeldin, D.C.3
  • 31
    • 13544255585 scopus 로고    scopus 로고
    • Do indoor pollutants and thermal comfort conditions in schools influence student performance? A critical review of the literature
    • Mendell M.J., Heath G.A. Do indoor pollutants and thermal comfort conditions in schools influence student performance? A critical review of the literature. Indoor Air 2005, 15:27-52.
    • (2005) Indoor Air , vol.15 , pp. 27-52
    • Mendell, M.J.1    Heath, G.A.2
  • 32
    • 79952508164 scopus 로고    scopus 로고
    • Association between substandard classroom ventilation rates and students' academic achievement
    • Haverinen-Shaughnessy U., Moschandreas D.J., Shaughnessy R. Association between substandard classroom ventilation rates and students' academic achievement. Indoor Air 2011, 21:121-131.
    • (2011) Indoor Air , vol.21 , pp. 121-131
    • Haverinen-Shaughnessy, U.1    Moschandreas, D.J.2    Shaughnessy, R.3
  • 33
    • 84872205148 scopus 로고    scopus 로고
    • http://www.sinphonie.eu/.
  • 34
    • 84880568166 scopus 로고    scopus 로고
    • Indoor air quality in 53 classrooms in Paris: chemical pollutants, allergens and ambiance parameters. Indoor Air 2011, Conference Proceedings.
    • Ravelomanantsoa H, Diallo S, Dusséaux M, Bordenave L, Barral S. Indoor air quality in 53 classrooms in Paris: chemical pollutants, allergens and ambiance parameters. Indoor Air 2011, Conference Proceedings.
    • Ravelomanantsoa, H.1    Diallo, S.2    Dusséaux, M.3    Bordenave, L.4    Barral, S.5
  • 36
    • 84880527031 scopus 로고    scopus 로고
    • Impact of airing behaviour on air stuffiness in schools and daycares centers: Development of a specific tool for ventilation management. Indoor Air 2011, Conference Proceedings.
    • Ribéron J, Derbez M, Lethrosne M, Kirchner S. Impact of airing behaviour on air stuffiness in schools and daycares centers: Development of a specific tool for ventilation management. Indoor Air 2011, Conference Proceedings.
    • Ribéron, J.1    Derbez, M.2    Lethrosne, M.3    Kirchner, S.4
  • 37
    • 84880556561 scopus 로고    scopus 로고
    • Impact of airing behavior on indoor air quality in schools and daycare centers. Indoor Air 2011, Conference Proceedings.
    • Derbez M, Ribéron J, Lethrosne M, Kirchner S. Impact of airing behavior on indoor air quality in schools and daycare centers. Indoor Air 2011, Conference Proceedings.
    • Derbez, M.1    Ribéron, J.2    Lethrosne, M.3    Kirchner, S.4
  • 38
    • 80054850966 scopus 로고    scopus 로고
    • Campagne pilote nationale de la surveillance de la qualité de l'air dans les écoles et crèches. Résultats de la première phase
    • Michelot N., Mandin C., Ramalho O., Ribéron J., Marchand C., Malherbe L., et al. Campagne pilote nationale de la surveillance de la qualité de l'air dans les écoles et crèches. Résultats de la première phase. Pollut Atm 2011, 211:267-279.
    • (2011) Pollut Atm , vol.211 , pp. 267-279
    • Michelot, N.1    Mandin, C.2    Ramalho, O.3    Ribéron, J.4    Marchand, C.5    Malherbe, L.6
  • 39
    • 84872211005 scopus 로고    scopus 로고
    • Contribution des appareils de bureautique à la pollution de l'air intérieur
    • Déléry L., Mandin C. Contribution des appareils de bureautique à la pollution de l'air intérieur. Pollut Atm 2009, 203:259-263.
    • (2009) Pollut Atm , vol.203 , pp. 259-263
    • Déléry, L.1    Mandin, C.2
  • 40
    • 33645243567 scopus 로고    scopus 로고
    • Organic compounds in office environment: sensory irritation, odor, measurements, and the role of reactive chemistry
    • Wolkoff P., Wilkins C.K., Clausen P.A., Nielsen G.D. Organic compounds in office environment: sensory irritation, odor, measurements, and the role of reactive chemistry. Indoor Air 2006, 16:7-19.
    • (2006) Indoor Air , vol.16 , pp. 7-19
    • Wolkoff, P.1    Wilkins, C.K.2    Clausen, P.A.3    Nielsen, G.D.4
  • 41
    • 33745698443 scopus 로고    scopus 로고
    • The modern office environment desiccates the eyes?
    • Wolkoff P., Nojgaard J.K., Franck C., Skov P. The modern office environment desiccates the eyes?. Indoor Air 2006, 16:258-265.
    • (2006) Indoor Air , vol.16 , pp. 258-265
    • Wolkoff, P.1    Nojgaard, J.K.2    Franck, C.3    Skov, P.4
  • 42
    • 84872221070 scopus 로고    scopus 로고
    • Building Assessment Survey and Evaluation (BASE) Study. U.S. Environmental Protection Agency.
    • Building Assessment Survey and Evaluation (BASE) Study. U.S. Environmental Protection Agency. http://www.epa.gov/iaq/base/.
  • 43
    • 77956229124 scopus 로고    scopus 로고
    • Comfort of workers in office buildings: The European HOPE project
    • Bluyssen P.M., Aries M., van Dommelen P. Comfort of workers in office buildings: The European HOPE project. Build Environ 2011, 46:280-288.
    • (2011) Build Environ , vol.46 , pp. 280-288
    • Bluyssen, P.M.1    Aries, M.2    van Dommelen, P.3
  • 44
    • 61549124420 scopus 로고    scopus 로고
    • Airborne concentrations of volatile organic compounds, formaldehyde and ammonia in Finnish office buildings with suspected indoor air problems
    • Salonen H., Pasanen A.-L., Lappalainen S., Riuttala H., Tuomi T., Pasanen P., et al. Airborne concentrations of volatile organic compounds, formaldehyde and ammonia in Finnish office buildings with suspected indoor air problems. J Occup Environ Hyg 2009, 6:200-209.
    • (2009) J Occup Environ Hyg , vol.6 , pp. 200-209
    • Salonen, H.1    Pasanen, A.-L.2    Lappalainen, S.3    Riuttala, H.4    Tuomi, T.5    Pasanen, P.6
  • 46
    • 77649271516 scopus 로고    scopus 로고
    • Speciation and diurnal variation of thoracic, fine thoracic and sub-micrometer airborne particulate matter at naturally ventilated office environments
    • Horemans B., Van Grieken R. Speciation and diurnal variation of thoracic, fine thoracic and sub-micrometer airborne particulate matter at naturally ventilated office environments. Atmos Environ 2010, 44:1497-1505.
    • (2010) Atmos Environ , vol.44 , pp. 1497-1505
    • Horemans, B.1    Van Grieken, R.2
  • 47
    • 77956877975 scopus 로고    scopus 로고
    • Brominated flame retardants and perfluorinated compounds in indoor dust from homes and offices in Flanders, Belgium
    • D'Hollander W., Roosens L., Covaci A., Cornelis C., Reynders H., Van Campenhout K., et al. Brominated flame retardants and perfluorinated compounds in indoor dust from homes and offices in Flanders, Belgium. Chemosphere 2010, 81:478-487.
    • (2010) Chemosphere , vol.81 , pp. 478-487
    • D'Hollander, W.1    Roosens, L.2    Covaci, A.3    Cornelis, C.4    Reynders, H.5    Van Campenhout, K.6
  • 49
    • 80052306547 scopus 로고    scopus 로고
    • Exposure to PBDEs in the office environment: evaluating the relationships between dust, handwipes, and serum
    • Watkins D.J., McClean M.D., Fraser A.J., Weinberg J., Stapleton H.M., Sjödin A., et al. Exposure to PBDEs in the office environment: evaluating the relationships between dust, handwipes, and serum. Environ Health Perspect 2011, 119:1247-1252.
    • (2011) Environ Health Perspect , vol.119 , pp. 1247-1252
    • Watkins, D.J.1    McClean, M.D.2    Fraser, A.J.3    Weinberg, J.4    Stapleton, H.M.5    Sjödin, A.6
  • 50
    • 42549126849 scopus 로고    scopus 로고
    • Decreasing irritation symptoms by replacing partially coated acoustic glass wool boards with fully coated boards
    • Palomäki E., Uitti J., Virtema P., Voutilainen R., Heinijoki L., Savolainen A. Decreasing irritation symptoms by replacing partially coated acoustic glass wool boards with fully coated boards. SJWEH Suppl 2008, 4:64-68.
    • (2008) SJWEH Suppl , vol.4 , pp. 64-68
    • Palomäki, E.1    Uitti, J.2    Virtema, P.3    Voutilainen, R.4    Heinijoki, L.5    Savolainen, A.6
  • 52
    • 40349111463 scopus 로고    scopus 로고
    • Structural equation analysis of the causal relationship between health and perceived indoor environment
    • Brauer C., Budtz-Jørgensen E., Mikkelsen S. Structural equation analysis of the causal relationship between health and perceived indoor environment. Int Arch Occup Environ Health 2008, 81:769-776.
    • (2008) Int Arch Occup Environ Health , vol.81 , pp. 769-776
    • Brauer, C.1    Budtz-Jørgensen, E.2    Mikkelsen, S.3
  • 53
    • 84872221111 scopus 로고    scopus 로고
    • RHEVA. Federation of European Heating and Air-conditioning Associations. Indoor Climate and Productivity in Offices, Guidebook N°6, 2006. Wargocki P, Seppänen O (editors).
    • RHEVA. Federation of European Heating and Air-conditioning Associations. Indoor Climate and Productivity in Offices, Guidebook N°6, 2006. Wargocki P, Seppänen O (editors).
  • 54
    • 80052624290 scopus 로고    scopus 로고
    • Benefits and costs of improved IEQ in U.S. offices
    • Fisk W.J., Black D., Brunner G. Benefits and costs of improved IEQ in U.S. offices. Indoor Air 2011, 21:357-367.
    • (2011) Indoor Air , vol.21 , pp. 357-367
    • Fisk, W.J.1    Black, D.2    Brunner, G.3
  • 55
    • 84872211451 scopus 로고    scopus 로고
    • http://www.officair-project.eu/.
  • 58
    • 81555204450 scopus 로고    scopus 로고
    • Health effects of disinfection byproducts in chlorinated swimming pools
    • Florentin A., Hautemanière A., Hartemann P. Health effects of disinfection byproducts in chlorinated swimming pools. Int J Hyg Environ Health 2011, 214:461-469.
    • (2011) Int J Hyg Environ Health , vol.214 , pp. 461-469
    • Florentin, A.1    Hautemanière, A.2    Hartemann, P.3
  • 59
    • 78649934096 scopus 로고    scopus 로고
    • Development of a multipathway probabilistic health risk assessment model for swimmers exposed to chloroform in indoor swimming pools
    • Chen M.J., Lin C.H., Duh J.M., Chou W.S., Hsu H.T. Development of a multipathway probabilistic health risk assessment model for swimmers exposed to chloroform in indoor swimming pools. J Hazard Mat 2011, 185:1037-1044.
    • (2011) J Hazard Mat , vol.185 , pp. 1037-1044
    • Chen, M.J.1    Lin, C.H.2    Duh, J.M.3    Chou, W.S.4    Hsu, H.T.5
  • 60
    • 80052271813 scopus 로고    scopus 로고
    • Trihalomethane exposures in indoor swimming pools: a level III fugacity model
    • Dyck R., Sadiq R., Rodriguez M.J., Simard S., Tardif R. Trihalomethane exposures in indoor swimming pools: a level III fugacity model. Water Res 2011, 45:5084-5098.
    • (2011) Water Res , vol.45 , pp. 5084-5098
    • Dyck, R.1    Sadiq, R.2    Rodriguez, M.J.3    Simard, S.4    Tardif, R.5
  • 62
    • 79955091249 scopus 로고    scopus 로고
    • Characterization of coarse particulate matter in school gyms
    • BraniŠ M., Šafránek J. Characterization of coarse particulate matter in school gyms. Environ Res 2011, 111:485-491.
    • (2011) Environ Res , vol.111 , pp. 485-491
    • Braniš, M.1    Šafránek, J.2
  • 63
    • 79955134107 scopus 로고    scopus 로고
    • Indoor and outdoor sources of size-resolved mass concentration of particulate matter in a school gym-implications for exposure of exercising children
    • BraniŠ M., Safránek J., Hytychová A. Indoor and outdoor sources of size-resolved mass concentration of particulate matter in a school gym-implications for exposure of exercising children. Environ Sci Pollut Res Int 2011, 18:598-609.
    • (2011) Environ Sci Pollut Res Int , vol.18 , pp. 598-609
    • Braniš, M.1    Safránek, J.2    Hytychová, A.3
  • 65
    • 41349118348 scopus 로고    scopus 로고
    • Phenyl mercuric acetate (PMA): mercury-bearing flexible gymnasium floors in schools-evaluation of hazards and controlled abatement
    • Beaulieu H.J., Beaulieu S., Brown C. Phenyl mercuric acetate (PMA): mercury-bearing flexible gymnasium floors in schools-evaluation of hazards and controlled abatement. J Occup Environ Hyg 2008, 5:360-366.
    • (2008) J Occup Environ Hyg , vol.5 , pp. 360-366
    • Beaulieu, H.J.1    Beaulieu, S.2    Brown, C.3
  • 66
    • 84872218127 scopus 로고    scopus 로고
    • Mercury emissions from polyurethane flooring in gymnasiums. Indoor Air 2011, Conference Proceedings.
    • Jones S, Liu Z, Little JC. Mercury emissions from polyurethane flooring in gymnasiums. Indoor Air 2011, Conference Proceedings.
    • Jones, S.1    Liu, Z.2    Little, J.C.3
  • 67
    • 84872220896 scopus 로고    scopus 로고
    • NILU. Measurement of air pollution in indoor artificial turf halls, Norwegian Institute for Air Research, Report NILU OR 03/2006, 39 pages.
    • NILU. Measurement of air pollution in indoor artificial turf halls, Norwegian Institute for Air Research, Report NILU OR 03/2006, 39 pages.
  • 69
    • 77957945527 scopus 로고    scopus 로고
    • Children's indoor leisure activities in France: time budget data for indoor air risk assessment
    • Guillam M.-T., Thomas N., Nedellec V., Derbez M., Kirchner S., Pédrono G., et al. Children's indoor leisure activities in France: time budget data for indoor air risk assessment. Hum Ecol Risk Assess 2010, 16:977-988.
    • (2010) Hum Ecol Risk Assess , vol.16 , pp. 977-988
    • Guillam, M.-T.1    Thomas, N.2    Nedellec, V.3    Derbez, M.4    Kirchner, S.5    Pédrono, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.