-
1
-
-
84988719809
-
-
WHO
-
WHO, "Diabetes," http://www.who.int/mediacentre/factsheets/fs312/en/.
-
Diabetes
-
-
-
2
-
-
26844548373
-
Monitoring glycemic control: The importance of self-monitoring of blood glucose
-
E. Renard, "Monitoring glycemic control: the importance of self-monitoring of blood glucose," Am. J. Med. 118, 12S-19S (2005).
-
(2005)
Am. J. Med
, vol.118
-
-
Renard, E.1
-
3
-
-
44349148840
-
Current development in non-invasive glucose monitoring
-
C. E. F. do Amaral and B. Wolf, "Current development in non-invasive glucose monitoring," Med. Eng. Phys. 30, 541-549 (2008).
-
(2008)
Med. Eng. Phys
, vol.30
, pp. 541-549
-
-
do Amaral, C.E.F.1
Wolf, B.2
-
4
-
-
0032995738
-
Spectroscopic and clinical aspects of noninvasive glucose measurements
-
O. S. Khalil, "Spectroscopic and clinical aspects of noninvasive glucose measurements," Clin. Chem. 45, 165-177 (1999).
-
(1999)
Clin. Chem
, vol.45
, pp. 165-177
-
-
Khalil, O.S.1
-
5
-
-
6044275963
-
Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the millennium
-
O. S. Khalil, "Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the millennium," Diabetes Technol. Ther. 6, 660-697 (2004).
-
(2004)
Diabetes Technol. Ther
, vol.6
, pp. 660-697
-
-
Khalil, O.S.1
-
6
-
-
0033624437
-
Optical glucose sensing in biological fluids: An overview
-
R. J. McNichols and G. L. Cotè, "Optical glucose sensing in biological fluids: an overview," J. Biomed. Opt. 5, 5-16 (2000).
-
(2000)
J. Biomed. Opt
, vol.5
, pp. 5-16
-
-
McNichols, R.J.1
Cotè, G.L.2
-
7
-
-
0000242875
-
Noninvasive glucose monitoring in vivo with an optical heterodyne polarimeter
-
C. Chou, C. Han, W. Kuo, Y. Huang, C. Feng, and J. Shyu, "Noninvasive glucose monitoring in vivo with an optical heterodyne polarimeter," Appl. Opt. 37, 3553-3557 (1998).
-
(1998)
Appl. Opt
, vol.37
, pp. 3553-3557
-
-
Chou, C.1
Han, C.2
Kuo, W.3
Huang, Y.4
Feng, C.5
Shyu, J.6
-
8
-
-
77951730780
-
Real-time, closed-loop dual-wavelength optical polarimetry for glucose monitoring
-
B. H. Malik, "Real-time, closed-loop dual-wavelength optical polarimetry for glucose monitoring," J. Biomed.Opt. 15, 017002 (2010).
-
(2010)
J. Biomed.Opt
, vol.15
, pp. 017002
-
-
Malik, B.H.1
-
9
-
-
27744577462
-
Ramanspectroscopy for noninvasive glucose measurements
-
A. M. K. Enejder, T. G. Scecina, J. Oh, M. Hunter, W. Shih, S. Sasic, G. L. Horowitz, and M. S. Feld, "Ramanspectroscopy for noninvasive glucose measurements," J. Biomed. Opt. 10, 031114 (2005).
-
(2005)
J. Biomed. Opt
, vol.10
, pp. 031114
-
-
Enejder, A.M.K.1
Scecina, T.G.2
Oh, J.3
Hunter, M.4
Shih, W.5
Sasic, S.6
Horowitz, G.L.7
Feld, M.S.8
-
10
-
-
23844450565
-
Glucose determination in human aqueous humor with Raman spectroscopy
-
J. L. Lambert, C. C. Pelletier, and M. Borchert, "Glucose determination in human aqueous humor with Raman spectroscopy," J. Biomed. Opt. 10, 031110 (2005).
-
(2005)
J. Biomed. Opt
, vol.10
, pp. 031110
-
-
Lambert, J.L.1
Pelletier, C.C.2
Borchert, M.3
-
11
-
-
84891711974
-
Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip
-
R. Marbach, T. Koschinsky, F. A. Gries, and H. M. Heise, "Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip," Appl. Spectrosc. 47, 875-881 (1993).
-
(1993)
Appl. Spectrosc
, vol.47
, pp. 875-881
-
-
Marbach, R.1
Koschinsky, T.2
Gries, F.A.3
Heise, H.M.4
-
12
-
-
0242269450
-
In vivo noninvasive measurement of blood glucose by nearinfrared diffuse-reflectance spectroscopy
-
K. Maruo, M. Tsurugi, M. Tamura, and Y. Ozaki, "In vivo noninvasive measurement of blood glucose by nearinfrared diffuse-reflectance spectroscopy," Appl. Spectrosc. 57, 1236-1244 (2003).
-
(2003)
Appl. Spectrosc
, vol.57
, pp. 1236-1244
-
-
Maruo, K.1
Tsurugi, M.2
Tamura, M.3
Ozaki, Y.4
-
13
-
-
79952095787
-
Continuous glucose monitoring by means of mid-infrared transmission laser spectroscopy in vitro
-
C. Vrancic, A. Fomichova, N. Gretz, C. Herrmann, S. Neudecker, A. Pucci, andW. Petrich, "Continuous glucose monitoring by means of mid-infrared transmission laser spectroscopy in vitro," Analyst 136, 1192-1198 (2011).
-
(2011)
Analyst
, vol.136
, pp. 1192-1198
-
-
Vrancic, C.1
Fomichova, A.2
Gretz, N.3
Herrmann, C.4
Neudecker, S.5
Pucci, A.6
Petrich, W.7
-
14
-
-
0033366694
-
Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia
-
I. Gabriely, R. Wozniak, M. Mevorach, J. Kaplan, Y. Aharon, and H. Shamoon, "Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia," Diabetes Care 22, 2026-2032 (1999).
-
(1999)
Diabetes Care
, vol.22
, pp. 2026-2032
-
-
Gabriely, I.1
Wozniak, R.2
Mevorach, M.3
Kaplan, J.4
Aharon, Y.5
Shamoon, H.6
-
15
-
-
0030355178
-
New concept for the non-invasive determination of physiological glucose concentrations using modulated laser diodes
-
G. Spanner and R. Niessner, "New concept for the non-invasive determination of physiological glucose concentrations using modulated laser diodes." Fresenius J. Anal. Chem. 355, 327-328 (1996).
-
(1996)
Fresenius J. Anal. Chem
, vol.355
, pp. 327-328
-
-
Spanner, G.1
Niessner, R.2
-
16
-
-
1642432727
-
A novel noninvasive blood glucose monitor
-
C. D. Malchoff, K. Shoukri, J. I. Landau, and J. M. Buchert, "A novel noninvasive blood glucose monitor," Diabetes Care 25, 2268-2275 (2002).
-
(2002)
Diabetes Care
, vol.25
, pp. 2268-2275
-
-
Malchoff, C.D.1
Shoukri, K.2
Landau, J.I.3
Buchert, J.M.4
-
17
-
-
77950814327
-
Wavelength-modulated differential laser photothermal radiometry for blood glucose measurements
-
X. Guo, A. Mandelis, A. Matvienko, K. Sivagurunathan, and B. Zinman, "Wavelength-modulated differential laser photothermal radiometry for blood glucose measurements," J. Phys. Conf. Ser. 214, 012025 (2010).
-
(2010)
J. Phys. Conf. Ser
, vol.214
, pp. 012025
-
-
Guo, X.1
Mandelis, A.2
Matvienko, A.3
Sivagurunathan, K.4
Zinman, B.5
-
18
-
-
33748423435
-
In vivo performance evaluation of a transdermal nearinfrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring
-
R. Ballerstadt, C. Evans, A. Gowda, and R. McNichols, "In vivo performance evaluation of a transdermal nearinfrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring," Diabetes Technol. Ther. 8, 296-311 (2006).
-
(2006)
Diabetes Technol. Ther
, vol.8
, pp. 296-311
-
-
Ballerstadt, R.1
Evans, C.2
Gowda, A.3
McNichols, R.4
-
19
-
-
33748423133
-
Fluorescent measurement in the non-invasice contact lens glucose sensor
-
W. March, D. Lazzaro, and S. Rastogi, "Fluorescent measurement in the non-invasice contact lens glucose sensor," Diabetes Technol. Ther. 8, 312-317 (2006).
-
(2006)
Diabetes Technol. Ther
, vol.8
, pp. 312-317
-
-
March, W.1
Lazzaro, D.2
Rastogi, S.3
-
20
-
-
80052419177
-
New photoacoustic cell design for studying aqueous solutions and gels
-
J. Kottmann, J. M. Rey, and M. W. Sigrist, "New photoacoustic cell design for studying aqueous solutions and gels," Rev. Sci. Instrum. 82, 084903 (2011).
-
(2011)
Rev. Sci. Instrum
, vol.82
, pp. 084903
-
-
Kottmann, J.1
Rey, J.M.2
Sigrist, M.W.3
-
21
-
-
0030356131
-
Noninvasive determination of blood constituents using an array of modulated laser diodes and a photoacoustic sensor head
-
G. Spanner and R. Niessner, "Noninvasive determination of blood constituents using an array of modulated laser diodes and a photoacoustic sensor head." Fresenius J. Anal. Chem. 354, 306-310 (1996).
-
(1996)
Fresenius J. Anal. Chem
, vol.354
, pp. 306-310
-
-
Spanner, G.1
Niessner, R.2
-
23
-
-
0001337773
-
Measurement of glucose in water first-overtone near-infrared spectra
-
K. H. Hazen, M. A. Arnold, and G. W. Small, "Measurement of glucose in water first-overtone near-infrared spectra," Appl. Spectrosc. 52, 1597-1605 (1998).
-
(1998)
Appl. Spectrosc
, vol.52
, pp. 1597-1605
-
-
Hazen, K.H.1
Arnold, M.A.2
Small, G.W.3
-
24
-
-
30344489001
-
Tunable laser diode system for noninvasive bloodglucose measutements
-
J. T. Olesberg, M. A. Arnold, C. Mermelstein, and J. Schmitz, "Tunable laser diode system for noninvasive bloodglucose measutements." Appl. Spectrosc. 59, 1480-1484 (2005).
-
(2005)
Appl. Spectrosc
, vol.59
, pp. 1480-1484
-
-
Olesberg, J.T.1
Arnold, M.A.2
Mermelstein, C.3
Schmitz, J.4
-
25
-
-
0032871481
-
Evaluation of measurement sites for noninvasive blood glucose sensing with near-infrared transmission spectroscopy
-
J. J. Burmeister and M. A. Arnold, "Evaluation of measurement sites for noninvasive blood glucose sensing with near-infrared transmission spectroscopy," Clin. Chem. 45, 1621-1627 (1999).
-
(1999)
Clin. Chem
, vol.45
, pp. 1621-1627
-
-
Burmeister, J.J.1
Arnold, M.A.2
-
26
-
-
0029510969
-
-
in The 8th International Conference on Solid-State Sensors and Actuators, 1995 and Eurosensors IX. Transducers '95
-
A. Duncan, J. Hannigan, S. S. Freeborn, and H. A. MacKenzie, "A portable non-invasive blood glucose monitor," in The 8th International Conference on Solid-State Sensors and Actuators, 1995 and Eurosensors IX. Transducers '95 (1995), pp. 455-458.
-
(1995)
A portable non-invasive blood glucose monitor
, pp. 455-458
-
-
Duncan, A.1
Hannigan, J.2
Freeborn, S.S.3
Mackenzie, H.A.4
-
27
-
-
0009699051
-
Blood glucose measurements by photoacoustics
-
AIP AIP Conference Proceedings
-
H. Ashton, H. A. Mac Kenzie, P. Rae, Y. C. Shen, S. Spiers, and J. Lindberg, "Blood glucose measurements by photoacoustics," in Proceedings of the 10th International Conference on Photoacoustic and Photothermal Phenomena, Vol. 463 of AIP Conference Proceedings (AIP, 1999), pp. 570-572.
-
(1999)
Proceedings of the 10th International Conference On Photoacoustic and Photothermal Phenomena
, vol.463
, pp. 570-572
-
-
Ashton, H.1
Mac-Kenzie, H.A.2
Rae, P.3
Shen, Y.C.4
Spiers, S.5
Lindberg, J.6
-
28
-
-
0032820949
-
Advances in photoacoustic noninvasive glucose testing
-
H. A. MacKenzie, H. Ashton, S. Spiers, and Y. Shen, "Advances in photoacoustic noninvasive glucose testing," Clin. Chem. 45, 1587-1595 (1999).
-
(1999)
Clin. Chem
, vol.45
, pp. 1587-1595
-
-
Mackenzie, H.A.1
Ashton, H.2
Spiers, S.3
Shen, Y.4
-
29
-
-
0027754155
-
Glucose determinaton by a pulsed photoacoustic techinque: An experimental study using a gelatin-based tissue phantom
-
K. M. Quan, G. B. Christison, H. A. MacKenzie, and P. Hodgson, "Glucose determinaton by a pulsed photoacoustic techinque: an experimental study using a gelatin-based tissue phantom." Phys. Med. Biol. 38, 1911-1922 (1993).
-
(1993)
Phys. Med. Biol
, vol.38
, pp. 1911-1922
-
-
Quan, K.M.1
Christison, G.B.2
Mackenzie, H.A.3
Hodgson, P.4
-
30
-
-
0000439352
-
Optical constants of water in the infrared
-
H. D. Downing and D. Williams, "Optical constants of water in the infrared," J. Geophys. Res. 80, 1656-1661 (1975).
-
(1975)
J. Geophys. Res
, vol.80
, pp. 1656-1661
-
-
Downing, H.D.1
Williams, D.2
-
32
-
-
12444301362
-
Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum
-
S. Gebhart, M. Faupel, R. Fowler, C. Kapsner, D. Lincoln, V. McGee, J. Pasqua, L. Steed, M. Wangsness, F. Xu, and M. Vanstory, "Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum," Diabetes Technol. Ther. 5, 159-166 (2003).
-
(2003)
Diabetes Technol. Ther
, vol.5
, pp. 159-166
-
-
Gebhart, S.1
Faupel, M.2
Fowler, R.3
Kapsner, C.4
Lincoln, D.5
McGee, V.6
Pasqua, J.7
Steed, L.8
Wangsness, M.9
Xu, F.10
Vanstory, M.11
-
33
-
-
71049152518
-
Clinical evaluation of a novel interstitial fluid sensor system for remote continuous alcohol monitoring
-
M. Venugopal, K. E. Feuvrel, D. Mongin, and et al., "Clinical evaluation of a novel interstitial fluid sensor system for remote continuous alcohol monitoring." IEEE Sensors J. 8, 71-80 (2008).
-
(2008)
IEEE Sensors J
, vol.8
, pp. 71-80
-
-
Venugopal, M.1
Feuvrel, K.E.2
Mongin, D.3
-
34
-
-
1542707453
-
Noninvasive glucose monitoring by back diffusionvia skin: Chemical and physical enhancements
-
Y. Huang, J. Fang, P. Wu, T. Chen, M. Tsai, and Y. Tsai, "Noninvasive glucose monitoring by back diffusionvia skin: chemical and physical enhancements," Biol. Pharm. Bull. 26, 983-987 (2003).
-
(2003)
Biol. Pharm. Bull
, vol.26
, pp. 983-987
-
-
Huang, Y.1
Fang, J.2
Wu, P.3
Chen, T.4
Tsai, M.5
Tsai, Y.6
-
35
-
-
50049089140
-
Modeling glucose and water dynamics in human skin
-
W. Groenendaal, K. A. Schmidt, G. von Basum, N. A. W. van Riel, and P. A. J. Hilbers, "Modeling glucose and water dynamics in human skin," Diabetes Technol. Ther. 10, 283-293 (2008).
-
(2008)
Diabetes Technol. Ther
, vol.10
, pp. 283-293
-
-
Groenendaal, W.1
Schmidt, K.A.2
von Basum, G.3
van Riel, N.A.W.4
Hilbers, P.A.J.5
-
36
-
-
0036435657
-
Mid-FTIR-microspectroscopy of stratum corneum single cells and stratum corneum tissue
-
P. Garidel, "Mid-FTIR-microspectroscopy of stratum corneum single cells and stratum corneum tissue," Phys.Chem. Chem. Phys. 4, 5671-5677 (2002).
-
(2002)
Phys.Chem. Chem. Phys
, vol.4
, pp. 5671-5677
-
-
Garidel, P.1
-
37
-
-
0042121374
-
Barrier function of the skin: "La raison d'être" of the epidermis
-
K. C. Madison, "Barrier function of the skin: "La raison d'être" of the epidermis," J. Invest. Dermatol. 121, 231-241 (2003).
-
(2003)
J. Invest. Dermatol
, vol.121
, pp. 231-241
-
-
Madison, K.C.1
-
38
-
-
0032095047
-
Application of mid-infrared transmission spectrometry to the direct determination of glucose inwhole blood
-
R. Vonach, "Application of mid-infrared transmission spectrometry to the direct determination of glucose inwhole blood," Appl. Spectrosc. 52, 820-822 (1998).
-
(1998)
Appl. Spectrosc
, vol.52
, pp. 820-822
-
-
Vonach, R.1
-
39
-
-
78349274978
-
Tunable external cavity quantum cascade laser for simultaneous determination of glucose and lactate in aqueous phase
-
M. Brandstetter, A. Genner, K. Anic, and B. Lendl, "Tunable external cavity quantum cascade laser for simultaneous determination of glucose and lactate in aqueous phase," Analyst 135, 3260-3265 (2010).
-
(2010)
Analyst
, vol.135
, pp. 3260-3265
-
-
Brandstetter, M.1
Genner, A.2
Anic, K.3
Lendl, B.4
-
40
-
-
0027593874
-
Laser photoacoustic determination of physiological glucose concentrations in human whole blood
-
G. B. Christison and H. A. MacKenzie, "Laser photoacoustic determination of physiological glucose concentrations in human whole blood," Med. Biol. Eng. Comput. 31, 284-290 (1993).
-
(1993)
Med. Biol. Eng. Comput
, vol.31
, pp. 284-290
-
-
Christison, G.B.1
Mackenzie, H.A.2
-
41
-
-
22144457131
-
A novel approch to non-invasive glucose measurement by mid-infrared spectroscopy: The combination of quantum cascade lasers (QCL) and photoacoustic detection
-
H. von Lilienfeld-Toal, M. Weidenmüller, A. Xhelaj, and W. Mäntele, "A novel approch to non-invasive glucose measurement by mid-infrared spectroscopy: The combination of quantum cascade lasers (QCL) and photoacoustic detection," Vib. Spectrosc. 38, 209-215 (2005).
-
(2005)
Vib. Spectrosc
, vol.38
, pp. 209-215
-
-
von Lilienfeld-Toal, H.1
Weidenmüller, M.2
Xhelaj, A.3
Mäntele, W.4
-
42
-
-
81155128014
-
Infrared spectroscopic analysis of human interstitial fluid in vitro and in vivo using FT-IR spectroscopy and pulsed quantum cascade lasers (QCL): Establishing a new approach to non invasive glucose measurement
-
M. Pleitez, H. von Lilienfeld-Toal, and W. Mäntele, "Infrared spectroscopic analysis of human interstitial fluid in vitro and in vivo using FT-IR spectroscopy and pulsed quantum cascade lasers (QCL): Establishing a new approach to non invasive glucose measurement," Spectrochim. Acta A 85, 61-65 (2012).
-
(2012)
Spectrochim. Acta A
, vol.85
, pp. 61-65
-
-
Pleitez, M.1
von Lilienfeld-Toal, H.2
Mäntele, W.3
-
43
-
-
0016873312
-
Theory of photoacoustic effect with solids
-
A. Rosencwaig and A. Gersho, "Theory of photoacoustic effect with solids," J. Appl. Phys. 47, 64-69 (1976).
-
(1976)
J. Appl. Phys
, vol.47
, pp. 64-69
-
-
Rosencwaig, A.1
Gersho, A.2
-
44
-
-
0039531581
-
Applications of photoacoustic sensing techniques
-
A. C. Tam, "Applications of photoacoustic sensing techniques," Rev. Mod. Phys. 58, 381-431 (1986).
-
(1986)
Rev. Mod. Phys
, vol.58
, pp. 381-431
-
-
Tam, A.C.1
-
45
-
-
84859318079
-
New photoacoustic cell with diamond window for mid-infrared investigations on biological samples
-
J. Kottmann, J. M. Rey, and M. W. Sigrist, "New photoacoustic cell with diamond window for mid-infrared investigations on biological samples," Proc. SPIE 8223, 82231A (2012).
-
(2012)
Proc. SPIE 8223
, pp. 82231
-
-
Kottmann, J.1
Rey, J.M.2
Sigrist, M.W.3
-
47
-
-
84988143968
-
Fourier transform Raman and infrared vibrational study of human skin: Assignment of spectral bands
-
R. W. Barry, H. G. M. Edwards, and A. C. Williams, "Fourier transform Raman and infrared vibrational study of human skin: Assignment of spectral bands," J. Raman Spectrosc. 23, 641-645 (1992).
-
(1992)
J. Raman Spectrosc
, vol.23
, pp. 641-645
-
-
Barry, R.W.1
Edwards, H.G.M.2
Williams, A.C.3
-
48
-
-
0032115511
-
Band analysis of hydrated human skin stratum corneum attenuated total reflectance fourier transform infrared spectra in vivo
-
G.W. Lucassen, G. N. A. van Veen, and J. A. J. Jansen, "Band analysis of hydrated human skin stratum corneum attenuated total reflectance fourier transform infrared spectra in vivo," J. Biomed. Opt. 3, 267-280 (1998).
-
(1998)
J. Biomed. Opt
, vol.3
, pp. 267-280
-
-
Lucassen, G.W.1
van Veen, G.N.A.2
Jansen, J.A.J.3
-
49
-
-
0021843914
-
A noninvasive, in vivo technique to quantitativelymeasure water concentration of the stratum corneum using attenuated total-reflectance Infrared spectroscopy
-
R. O. Potts, B. G. Guzek, R. R. Harris, and J. E. McKie, "A noninvasive, in vivo technique to quantitativelymeasure water concentration of the stratum corneum using attenuated total-reflectance Infrared spectroscopy," Arch. Dermatol. Res. 277, 489-495 (1985).
-
(1985)
Arch. Dermatol. Res
, vol.277
, pp. 489-495
-
-
Potts, R.O.1
Guzek, B.G.2
Harris, R.R.3
McKie, J.E.4
-
50
-
-
0019802369
-
On the use of infrared spectroscopy for the in vivo measurement ofthe water content of the horny layer after application of dermatologic Ointments
-
M. Gloor, G. Hirsch, and U. Willebrand, "On the use of infrared spectroscopy for the in vivo measurement ofthe water content of the horny layer after application of dermatologic Ointments," Arch. Dermatol. Res. 271, 305-313 (1981).
-
(1981)
Arch. Dermatol. Res
, vol.271
, pp. 305-313
-
-
Gloor, M.1
Hirsch, G.2
Willebrand, U.3
|