메뉴 건너뛰기




Volumn 8, Issue 1, 2008, Pages 71-80

Clinical evaluation of a novel interstitial fluid sensor system for remote continuous alcohol monitoring

Author keywords

Alcohol monitoring; Biological liquids; Biomedical transducers; Medical services; Wireless LAN

Indexed keywords

ALCOHOL CONCENTRATIONS; ALCOHOL LEVELS; BIOLOGICAL LIQUIDS; BIOMEDICAL TRANSDUCERS; CELLULAR PHONE NETWORKS; CLINICAL EVALUATION; CLINICAL STUDY; HEALTH MONITORING SYSTEM; HUMAN SUBJECTS; INTERSTITIAL FLUIDS; LABORATORY SET-UP; LINEAR RESPONSE; MEDICAL SERVICES; MICROPORES; MINIMALLY INVASIVE; NEAR-INFRARED LASERS; ORAL INTAKE; REMOTE MONITORING; SENSOR DATA; SENSOR READINGS; STRATUM CORNEUM; VACUUM PRESSURE; WIRELESS LAN;

EID: 71049152518     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2007.912544     Document Type: Article
Times cited : (65)

References (52)
  • 1
    • 0030879505 scopus 로고    scopus 로고
    • Dermal interstitial glucose as an indicator of ambient glycemia
    • F. J. Service, P. C. O'Brien, S. D. Wise, S. Ness, andS. M. LeBlanc, "Dermal interstitial glucose as an indicator of ambient glycemia," Diabetes Care, vol. 20, pp. 1426-1429, 1997.
    • (1997) Diabetes Care , vol.20 , pp. 1426-1429
    • Service, F.J.1    O'Brien, P.C.2    Wise, S.D.3    Ness, S.4    LeBlanc, S.M.5
  • 2
    • 0035180717 scopus 로고    scopus 로고
    • Barriers to non-insulin dependent diabetes mellitus (NIDDM) self-care practices among older women
    • N. E. Schoenberg andS. C. Drungle, "Barriers to non-insulin dependent diabetes mellitus (NIDDM) self-care practices among older women," J Aging Health, vol. 13, pp. 443-466, 2001.
    • (2001) J Aging Health , vol.13 , pp. 443-466
    • Schoenberg, N.E.1    Drungle, S.C.2
  • 3
    • 0026886448 scopus 로고
    • Diabetes health beliefs, self-care behaviors, and glycemic control among older adults with non-insulin-dependent diabetes mellitus
    • R. K. Polly, "Diabetes health beliefs, self-care behaviors, and glycemic control among older adults with non-insulin-dependent diabetes mellitus," Diabetes Edu., vol. 18, pp. 321-327, 1992.
    • (1992) Diabetes Edu. , vol.18 , pp. 321-327
    • Polly, R.K.1
  • 4
    • 0028067965 scopus 로고
    • Clinical usefulness of the glucose concentration in the subcutaneous tissue-Properties and pitfalls of electrochemical biosensors
    • U. Fischer, K. Rebrin, T. von Woedtke, and P. Abel, "Clinical usefulness of the glucose concentration in the subcutaneous tissue-Properties and pitfalls of electrochemical biosensors," Harm Metab. Res., vol. 26, pp. 515-522, 1994.
    • (1994) Harm Metab. Res. , vol.26 , pp. 515-522
    • Fischer, U.1    Rebrin, K.2    Von Woedtke, T.3    Abel, P.4
  • 5
    • 0029101233 scopus 로고
    • Subcutaneous glucose concentration in humans. Real estimation and continuous monitoring
    • F. Sternberg, C. Meyerhoff, F. J. Mennel, F. Bischof, andE. F. Pfeiffer, "Subcutaneous glucose concentration in humans. Real estimation and continuous monitoring," Diabetes Care, vol. 18, pp. 1266-1269, 1995.
    • (1995) Diabetes Care , vol.18 , pp. 1266-1269
    • Sternberg, F.1    Meyerhoff, C.2    Mennel, F.J.3    Bischof, F.4    Pfeiffer, E.F.5
  • 7
    • 0033188401 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Long-term implantable sensor approach
    • G. Y. Daniloff, "Continuous glucose monitoring: Long-term implantable sensor approach," Diabetes Technol Ther., vol. 1, pp. 261-266, 1999.
    • (1999) Diabetes Technol Ther. , vol.1 , pp. 261-266
    • Daniloff, G.Y.1
  • 8
    • 14844356007 scopus 로고    scopus 로고
    • Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles
    • P. M. Wang, M. Cornwell, andM. R. Prausnitz, "Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles," Diabetes Technol. Ther., vol. 7, pp. 131-141, 2005.
    • (2005) Diabetes Technol. Ther. , vol.7 , pp. 131-141
    • Wang, P.M.1    Cornwell, M.2    Prausnitz, M.R.3
  • 9
    • 0031257640 scopus 로고    scopus 로고
    • Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
    • J. P. Bantle and W. Thomas, "Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid," J. Lab. Clin. Med., vol. 130, pp. 436-441, 1997.
    • (1997) J. Lab. Clin. Med. , vol.130 , pp. 436-441
    • Bantle, J.P.1    Thomas, W.2
  • 10
    • 0031036953 scopus 로고    scopus 로고
    • Noninvasive blood glucose monitoring
    • D. C. Klonoff, "Noninvasive blood glucose monitoring," Diabetes Care, vol. 20, pp. 433-437, 1997.
    • (1997) Diabetes Care , vol.20 , pp. 433-437
    • Klonoff, D.C.1
  • 11
    • 0033086369 scopus 로고    scopus 로고
    • Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: Implications for glucose monitoring
    • A. Smith, D. Yang, H. Delcher, J. Eppstein, D. Williams, and S. Wilkes, "Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: Implications for glucose monitoring," Diabetes Technol. Ther., vol. 1, pp. 21-27, 1999.
    • (1999) Diabetes Technol. Ther. , vol.1 , pp. 21-27
    • Smith, A.1    Yang, D.2    Delcher, H.3    Eppstein, J.4    Williams, D.5    Wilkes, S.6
  • 12
    • 6044261446 scopus 로고    scopus 로고
    • A novel approach to mitigating the physiological lag between blood and interstitial fluid glucose measurements
    • P. J. Stout, J. R. Racchini, andM. E. Hilgers, "A novel approach to mitigating the physiological lag between blood and interstitial fluid glucose measurements," Diabetes Technol. Ther., vol. 6, pp. 635-644, 2004.
    • (2004) Diabetes Technol. Ther. , vol.6 , pp. 635-644
    • Stout, P.J.1    Racchini, J.R.2    Hilgers, M.E.3
  • 13
    • 0034780892 scopus 로고    scopus 로고
    • Clinical evaluation of the GlucoWatch biographer: A continual, noninvasive glucose monitor for patients with diabetes
    • M. J. Tierney, J. A. Tamada, R. O. Potts, L. Jovanovic, and S. Garg, "Clinical evaluation of the GlucoWatch biographer: A continual, noninvasive glucose monitor for patients with diabetes," Biosens. Bioelectron., vol. 16, pp. 621-629, 2001.
    • (2001) Biosens. Bioelectron. , vol.16 , pp. 621-629
    • Tierney, M.J.1    Tamada, J.A.2    Potts, R.O.3    Jovanovic, L.4    Garg, S.5
  • 14
    • 0036113697 scopus 로고    scopus 로고
    • Glucose monitoring by reverse iontophoresis
    • R. O. Potts, J. A. Tamada, andM. J. Tierney, "Glucose monitoring by reverse iontophoresis," Diabetes Metab. Res. Rev., vol. 18, pp. S49-S53, 2002, Suppl. 1.
    • (2002) Diabetes Metab. Res. Rev. , vol.18 , Issue.SUPPL. 1
    • Potts, R.O.1    Tamada, J.A.2    Tierney, M.J.3
  • 16
    • 1442275314 scopus 로고    scopus 로고
    • The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges
    • D. C. Klonoff, "The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges," Diabetes Care, vol. 27, pp. 834-836, 2004.
    • (2004) Diabetes Care , vol.27 , pp. 834-836
    • Klonoff, D.C.1
  • 18
    • 0037278431 scopus 로고    scopus 로고
    • Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor
    • G. M. Steil, K. Rebrin, J. Mastrototaro, B. Bernaba, andM. F. Saad, "Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor," Diabetes Technol. Ther., vol. 5, pp. 27-31, 2003.
    • (2003) Diabetes Technol. Ther. , vol.5 , pp. 27-31
    • Steil, G.M.1    Rebrin, K.2    Mastrototaro, J.3    Bernaba, B.4    Saad, M.F.5
  • 19
    • 0034491295 scopus 로고    scopus 로고
    • The MiniMed continuous glucose monitoring system
    • J. J. Mastrototaro, "The MiniMed continuous glucose monitoring system," Diabetes Technol. Ther., vol. 2, pp. S13-S18, 2000, Suppl. 1.
    • (2000) Diabetes Technol. Ther. , vol.2 , Issue.SUPPL. 1
    • Mastrototaro, J.J.1
  • 20
    • 0034095236 scopus 로고    scopus 로고
    • Transdermal alcohol measurement for estimation of blood alcohol concentration
    • R. Swift, "Transdermal alcohol measurement for estimation of blood alcohol concentration," Alcohol Clin. Exp. Res., vol. 24, pp. 422-423, 2000.
    • (2000) Alcohol Clin. Exp. Res. , vol.24 , pp. 422-423
    • Swift, R.1
  • 21
    • 0027327661 scopus 로고
    • Transdermal measurement of alcohol consumption
    • R. M. Swift, "Transdermal measurement of alcohol consumption," Addiction, vol. 88, pp. 1037-1039, 1993.
    • (1993) Addiction , vol.88 , pp. 1037-1039
    • Swift, R.M.1
  • 25
    • 43249091533 scopus 로고    scopus 로고
    • A new eye on law enforcement
    • B. Ver Steeg and T. Ridder, "A new eye on law enforcement," oeMagazine, vol. 5, pp. 26-28, 2005.
    • (2005) OeMagazine , vol.5 , pp. 26-28
    • Ver Steeg, B.1    Ridder, T.2
  • 26
    • 14044265604 scopus 로고    scopus 로고
    • Noninvasive alcohol testing using diffuse reflectance near-infrared spectroscopy
    • T. D. Ridder, S. P. Hendee, andC. D. Brown, "Noninvasive alcohol testing using diffuse reflectance near-infrared spectroscopy," Appl. Spectrosc., vol. 59, pp. 181-189, 2005.
    • (2005) Appl. Spectrosc. , vol.59 , pp. 181-189
    • Ridder, T.D.1    Hendee, S.P.2    Brown, C.D.3
  • 27
    • 33745319507 scopus 로고    scopus 로고
    • Coded aperture Raman spectroscopy for quantitative measurements of ethanol in a tissue phantom
    • S. T. McCain, M. E. Gehm, Y. Wang, N. P. Pitsianis, andD. J. Brady, "Coded aperture Raman spectroscopy for quantitative measurements of ethanol in a tissue phantom," Appl. Spectrosc., vol. 60, pp. 663-671, 2006.
    • (2006) Appl. Spectrosc. , vol.60 , pp. 663-671
    • McCain, S.T.1    Gehm, M.E.2    Wang, Y.3    Pitsianis, N.P.4    Brady, D.J.5
  • 28
    • 0034023939 scopus 로고    scopus 로고
    • Continuous glucose monitoring: The next step toward closing the loop
    • H. Shamoon, "Continuous glucose monitoring: The next step toward closing the loop," Diabetes Technol. Ther., vol. 2, pp. 57-59, 2000.
    • (2000) Diabetes Technol. Ther. , vol.2 , pp. 57-59
    • Shamoon, H.1
  • 30
    • 0030050878 scopus 로고    scopus 로고
    • Multivariate determination of glucose concentrations from optimally filtered frequency-warped NIR spectra of human blood serum
    • F. M. Ham, G. M. Cohen, I. Kostanic, andB. R. Gooch, "Multivariate determination of glucose concentrations from optimally filtered frequency-warped NIR spectra of human blood serum," Physiol. Meas., vol. 17, pp. 1-20, 1996.
    • (1996) Physiol. Meas. , vol.17 , pp. 1-20
    • Ham, F.M.1    Cohen, G.M.2    Kostanic, I.3    Gooch, B.R.4
  • 31
    • 0141465478 scopus 로고
    • Detection and classification of biological substances using infrared absorption spectroscopy and a hybrid artificial neural network
    • F. M. Ham, "Detection and classification of biological substances using infrared absorption spectroscopy and a hybrid artificial neural network," J. Artif. Neural Netw., vol. 1, pp. 101-114, 1994.
    • (1994) J. Artif. Neural Netw. , vol.1 , pp. 101-114
    • Ham, F.M.1
  • 32
    • 0034467470 scopus 로고    scopus 로고
    • The use of silicon microfabrication technology in painless blood glucose monitoring
    • W. H. Smart and. K. Subramanian, "The use of silicon microfabrication technology in painless blood glucose monitoring," Diabetes Technol. Ther., vol. 2, pp. 549-559, 2000.
    • (2000) Diabetes Technol. Ther. , vol.2 , pp. 549-559
    • Smart, W.H.1    Subramanian, K.2
  • 33
    • 32744461888 scopus 로고    scopus 로고
    • Lactate biosensors for continuous monitoring
    • J. W. Mo and W. Smart, "Lactate biosensors for continuous monitoring," Front Biosci., vol. 9, pp. 3384-3391, 2004.
    • (2004) Front Biosci. , vol.9 , pp. 3384-3391
    • Mo, J.W.1    Smart, W.2
  • 35
    • 34347393855 scopus 로고    scopus 로고
    • Isolation and characterization of mutated alcohol oxidases from the yeast Hansenula polymorpha with decreased affinity toward substrates and their use as selective elements of an amperometric biosensor
    • K. V. Dmytruk, O. V. Smutok, O. B. Ryabova, G. Z. Gayda, V. A. Sibirny, W. Schuhmann, M. V. Gonchar, andA. A. Sibirny, "Isolation and characterization of mutated alcohol oxidases from the yeast Hansenula polymorpha with decreased affinity toward substrates and their use as selective elements of an amperometric biosensor," BMC Biotechnol., vol. 7, p. 33, 2007.
    • (2007) BMC Biotechnol. , vol.7 , pp. 33
    • Dmytruk, K.V.1    Smutok, O.V.2    Ryabova, O.B.3    Gayda, G.Z.4    Sibirny, V.A.5    Schuhmann, W.6    Gonchar, M.V.7    Sibirny, A.A.8
  • 36
    • 0026836096 scopus 로고
    • An amperometric alcohol sensor based on chemically permeabilized methylotrophic microorganisms
    • J. C. Chen, T. J. Naglak, andH. Y. Wang, "An amperometric alcohol sensor based on chemically permeabilized methylotrophic microorganisms," Biotechnol. Prog., vol. 8, pp. 161-164, 1992.
    • (1992) Biotechnol. Prog. , vol.8 , pp. 161-164
    • Chen, J.C.1    Naglak, T.J.2    Wang, H.Y.3
  • 37
    • 0038721879 scopus 로고    scopus 로고
    • A revised pharmacokinetic model for alcohol
    • J. Lotsof, "A revised pharmacokinetic model for alcohol," Clin. Pharmacokinet, vol. 42, pp. 585-587, 2003.
    • (2003) Clin. Pharmacokinet , vol.42 , pp. 585-587
    • Lotsof, J.1
  • 38
    • 0032959604 scopus 로고    scopus 로고
    • A physiologically-based pharmacokinetic (PBPK) model for alcohol facilitates rapid BrAC clamping
    • V. A. Ramchandani, J. Bolane, T. K. Li, and S. O'Connor, "A physiologically-based pharmacokinetic (PBPK) model for alcohol facilitates rapid BrAC clamping," Alcohol Clin. Exp. Res., vol. 23, pp. 617-623, 1999.
    • (1999) Alcohol Clin. Exp. Res. , vol.23 , pp. 617-623
    • Ramchandani, V.A.1    Bolane, J.2    Li, T.K.3    O'Connor, S.4
  • 39
    • 19444388019 scopus 로고    scopus 로고
    • A physiologically based model for ethanol and acetaldehyde metabolism in human beings
    • D. M. Umulis, N. M. Gurmen, P. Singh, andH. S. Fogler, "A physiologically based model for ethanol and acetaldehyde metabolism in human beings," Alcohol, vol. 35, pp. 3-12, 2005.
    • (2005) Alcohol , vol.35 , pp. 3-12
    • Umulis, D.M.1    Gurmen, N.M.2    Singh, P.3    Fogler, H.S.4
  • 40
    • 0029999122 scopus 로고    scopus 로고
    • Acetaminophen, NSAIDs and alcohol
    • "Acetaminophen, NSAIDs and alcohol," Med. Lett. Drugs Ther., vol. 38, pp. 55-56, 1996.
    • (1996) Med. Lett. Drugs Ther. , vol.38 , pp. 55-56
  • 41
    • 0035692028 scopus 로고    scopus 로고
    • Acetaminophen use in patients who drink alcohol: Current study evidence
    • E. K. Kuffner andR. C. Dart, "Acetaminophen use in patients who drink alcohol: Current study evidence," Amer. J. Manage. Care, vol. 7, pp. S592-S596, 2001.
    • (2001) Amer. J. Manage. Care , vol.7
    • Kuffner, E.K.1    Dart, R.C.2
  • 45
    • 77956026626 scopus 로고    scopus 로고
    • Motes for mobile health monitoring and tele-medicine
    • A. Talukder, "Motes for mobile health monitoring and tele-medicine," Crossbow Solutions, vol. 6, pp. 1-4, 2005.
    • (2005) Crossbow Solutions , vol.6 , pp. 1-4
    • Talukder, A.1
  • 46
    • 85017378082 scopus 로고    scopus 로고
    • Energy management for battery-powered embedded systems
    • D. Rakhmatov and S. Vrudhula, "Energy management for battery-powered embedded systems," ACM Trans. Embedded Comput. Syst., vol. 2, pp. 277-324, 2003.
    • (2003) ACM Trans. Embedded Comput. Syst. , vol.2 , pp. 277-324
    • Rakhmatov, D.1    Vrudhula, S.2
  • 50
    • 1942439769 scopus 로고    scopus 로고
    • Distributed multisensor processing and classification under constrained resources for mobile health monitoring and remote environmental monitoring
    • A. Talukder, S. Monacos, and T. Sheikh, "Distributed multisensor processing and classification under constrained resources for mobile health monitoring and remote environmental monitoring," in Proc Int. Conf. lntell. Sensing Inf. Process (ISIP), 2004, pp. 212-217.
    • (2004) Proc Int. Conf. Lntell. Sensing Inf. Process (ISIP) , pp. 212-217
    • Talukder, A.1    Monacos, S.2    Sheikh, T.3
  • 51
    • 34247387468 scopus 로고    scopus 로고
    • Body sensor network-A wireless sensor platform for pervasive healthcare monitoring
    • H. W. Gellersen, R. Want, and A. Schmidt, Eds.
    • B. Lo, S. Thiemjarus, R. King, andG. Z. Yang, "Body sensor network-A wireless sensor platform for pervasive healthcare monitoring," in Proc. 3rd Int. Conf. Pervasive Comput. (PERVASIVE 2005), H. W. Gellersen, R. Want, and A. Schmidt, Eds., 2005, pp. 77-80.
    • (2005) Proc. 3rd Int. Conf. Pervasive Comput. (PERVASIVE 2005) , pp. 77-80
    • Lo, B.1    Thiemjarus, S.2    King, R.3    Yang, G.Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.