Volumn 6, Issue 5, 2012, Pages 539-547

Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples

Author keywords

Automation; DNA extraction; Forensic science; Liquid handling robot; Magnetic beads

Indexed keywords

GENOMIC DNA;

EID: 84863777969     PISSN: 18724973     EISSN: 18780326     Source Type: Journal    
DOI: 10.1016/j.fsigen.2012.01.002     Document Type: Article
Times cited : (44)

References (19)
  • 1
    • 0038416063 scopus 로고    scopus 로고
    • Isolation of genomic DNA from buccal swabs for forensic analysis, using fully automated silica-membrane purification technology
    • T.O. Hanselle, M. Otte, T. Schnibbe, E. Smythe, F. Krieg-Schneider, Isolation of genomic DNA from buccal swabs for forensic analysis, using fully automated silica-membrane purification technology, Legal Med. 5 (Suppl. 1) (2003) 145-149.
    • (2003) Legal Med. , vol.5 , Issue.SUPPL. 1 , pp. 145-149
    • Hanselle, T.O.1    Otte, M.2    Schnibbe, T.3    Smythe, E.4    Krieg-Schneider, F.5
  • 2
    • 0347651827 scopus 로고    scopus 로고
    • Application of the BioMek 2000 Laboratory Automation Workstation and the DNA IQ System to the Extraction of Forensic Casework Samples
    • S.A. Greenspoon, J.D. Ban, K. Sykes, E.J. Ballard, S.S. Edler, M. Baisden, B.L. Covington, Application of the BioMek 2000 Laboratory Automation Workstation and the DNA IQ System to the extraction of forensic casework samples, J. Forensic Sci. 49 (2004) 29-39. (Pubitemid 38063779)
    • (2004) Journal of Forensic Sciences , vol.49 , Issue.1 , pp. 29-39
    • Greenspoon, S.A.1    Ban, J.D.2    Sykes, K.3    Ballard, E.J.4    Edler, S.S.5    Baisden, M.6    Covington, B.L.7
  • 3
    • 20444391732 scopus 로고    scopus 로고
    • Optimization and validation of a fully automated silica-coated magnetic beads purification technology in forensics
    • DOI 10.1016/j.forsciint.2005.02.027, PII S0379073805001349
    • M. Nagy, P. Otremba, C. Kruger, S. Bergner-Greiner, P. Anders, B. Henske,M. Prinz, L. Roewer, Optimization and validation of a fully automated silica-coated magnetic beads purification technology in forensics, Forensic Sci. Int. 152 (2005) 13-22. (Pubitemid 40804495)
    • (2005) Forensic Science International , vol.152 , Issue.1 , pp. 13-22
    • Nagy, M.1    Otremba, P.2    Kruger, C.3    Bergner-Greiner, S.4    Anders, P.5    Henske, B.6    Prinz, M.7    Roewer, L.8
  • 4
    • 43449133847 scopus 로고    scopus 로고
    • Automated processing of forensic casework samples using robotic workstations equipped with nondisposable tips: Contamination prevention
    • DOI 10.1111/j.1556-4029.2008.00697.x
    • C.J. Fregeau, C.M. Lett, J. Elliott, C. Yensen, R.M. Fourney, Automated processing of forensic casework samples using robotic workstations equipped with nondisposable tips: contamination prevention, J. Forensic Sci. 53 (2008) 632-651. (Pubitemid 351667639)
    • (2008) Journal of Forensic Sciences , vol.53 , Issue.3 , pp. 632-651
    • Fregeau, C.J.1    Marc, L.C.2    Elliott, J.3    Yensen, C.4    Fourney, R.M.5
  • 5
    • 79955000781 scopus 로고    scopus 로고
    • Automated extraction of DNA from blood and PCR setup using a Tecan Freedom EVO liquid handler for forensic genetic STR typing of reference samples
    • M. Stangegaard, T.G. Frosley, A.J. Frank-Hansen, N. Morling, Automated extraction of DNA from blood and PCR setup using a Tecan Freedom EVO liquid handler for forensic genetic STR typing of reference samples, JALA 16 (2011) 134-140.
    • (2011) JALA , vol.16 , pp. 134-140
    • Stangegaard, M.1    Frosley, T.G.2    Frank-Hansen, A.J.3    Morling, N.4
  • 6
    • 84857059846 scopus 로고    scopus 로고
    • A comparison of methods for forensic DNA extraction: Chelex-100 and the QIAGEN DNA Investigator Kit (manual and automated)
    • in press, doi:10.1016/j.fsigen.2011.04.018
    • K. Philips, N. McCallum, L. Welch, A comparison of methods for forensic DNA extraction: Chelex-100 and the QIAGEN DNA Investigator Kit (manual and automated), Forensic Sci. Int. Genet. (2011), in press, doi:10.1016/j.fsigen. 2011.04.018.
    • (2011) Forensic Sci. Int. Genet.
    • Philips, K.1    McCallum, N.2    Welch, L.3
  • 7
    • 84863780502 scopus 로고    scopus 로고
    • Tecan/Applied Biosystems, Tecan Document Number 395576 v 1.0, Applied Biosystems Publication Number 112BR08-01
    • Tecan/Applied Biosystems, The HID EVOlution - Extraction System, Tecan Document Number 395576 v 1.0, Applied Biosystems Publication Number 112BR08-01, 2008.
    • (2008) The HID EVOlution - Extraction System
  • 8
    • 84863775234 scopus 로고    scopus 로고
    • Tecan/Applied Biosystems, Applied Biosystems Publication Number 112BR04-01
    • Tecan/Applied Biosystems, The HID EVOlution System, Applied Biosystems Publication Number 112BR04-01, 2007.
    • (2007) The HID EVOlution System
  • 9
    • 77956934318 scopus 로고    scopus 로고
    • The DNA IQ System on the Tecan Freedom EVO 100
    • C. Cowan, The DNA IQ System on the Tecan Freedom EVO 100, Profiles DNA 9 (2006) 8-10.
    • (2006) Profiles DNA , vol.9 , pp. 8-10
    • Cowan, C.1
  • 13
    • 0015061285 scopus 로고
    • Formation of disulphide bonds in the nucleus and accessory structures of mammalian spermatozoa during maturation in the epididymis
    • H.I. Calvin, J.M. Bedford, Formation of disulphide bonds in the nucleus and accessory structures of mammalian spermatozoa during maturation in the epididymis, J. Reprod. Fertil. 13 (1971) 65-75.
    • (1971) J. Reprod. Fertil. , vol.13 , pp. 65-75
    • Calvin, H.I.1    Bedford, J.M.2
  • 14
    • 0022344309 scopus 로고
    • Forensic application of DNA fingerprints
    • P. Gill, A.J. Jeffreys, D.J. Werrett, Forensic application of DNA fingerprints, Nature 318 (1985) 577-579.
    • (1985) Nature , vol.318 , pp. 577-579
    • Gill, P.1    Jeffreys, A.J.2    Werrett, D.J.3
  • 15
    • 0028948179 scopus 로고
    • The modified method of two-step differential extraction of sperm and vaginal epithelial cell DNA from vaginal fluid mixed with semen
    • K. Yoshida, K. Sekiguchi, N. Mizuno, K. Kasai, I. Sakai, H. Sato, S. Seta, The modified method of two-step differential extraction of sperm and vaginal epithelial cell DNA from vaginal fluid mixed with semen, Forensic Sci. Int. 72 (1995) 25-33.
    • (1995) Forensic Sci. Int. , vol.72 , pp. 25-33
    • Yoshida, K.1    Sekiguchi, K.2    Mizuno, N.3    Kasai, K.4    Sakai, I.5    Sato, H.6    Seta, S.7
  • 17
    • 65349137014 scopus 로고    scopus 로고
    • Developmental validationof the PrepFiler ForensicDNAExtractionKit for extraction of genomic DNA from biological samples
    • M.G. Brevnov, H.S. Pawar, J. Mundt, L.M. Calandro, M.R. Furtado, J.G. Shewale, Developmental validationof the PrepFiler ForensicDNAExtractionKit for extraction of genomic DNA from biological samples, J. Forensic Sci. 54 (2009) 599-607.
    • (2009) J. Forensic Sci. , vol.54 , pp. 599-607
    • Brevnov, M.G.1    Pawar, H.S.2    Mundt, J.3    Calandro, L.M.4    Furtado, M.R.5    Shewale, J.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.