Volumn 39, Issue 6, 2012, Pages 3031-3040

Establishing a standard calibration methodology for MOSFET detectors in computed tomography dosimetry

Author keywords

CT; MOSFET; radiation dosimetry

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DOSIMETRY; METALS; MOS DEVICES; MOSFET DEVICES; OXIDE SEMICONDUCTORS; PHANTOMS; RADIATION DECONTAMINATION; X RAY RADIOGRAPHY; X RAY TUBES; X RAYS;

EID: 84863526871     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4712221     Document Type: Article
Times cited : (19)

References (26)
  • 1
    • 0033013459 scopus 로고    scopus 로고
    • Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology
    • D. J. Peet and M. D. Pryor, Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology., Br. J. Radiol. 72, 562-568 (1999).
    • (1999) Br. J. Radiol. , vol.72 , pp. 562-568
    • Peet, D.J.1    Pryor, M.D.2
  • 2
    • 44649108419 scopus 로고    scopus 로고
    • Surface dosimetry in a CT scanner using MOSFET detectors and Monte Carlo simulations
    • 10.1088/1742-6596/102/1/01206
    • F. Verhaegen, M. Lemire, A. Hallil, and G. Hegyi, Surface dosimetry in a CT scanner using MOSFET detectors and Monte Carlo simulations., J. Phys.: Conf. Ser. 102, 1-7 (2008). 10.1088/1742-6596/102/1/01206
    • (2008) J. Phys.: Conf. Ser. , vol.102 , pp. 1-7
    • Verhaegen, F.1    Lemire, M.2    Hallil, A.3    Hegyi, G.4
  • 3
    • 36249002355 scopus 로고    scopus 로고
    • Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: Implications for cancer induction
    • 10.1148/radiol.2453062046
    • L. M. Hurwitz, R. E. Reiman, T. T. Yoshizumi, P. C. Goodman, G. Toncheva, G. Nguyen, and C. Lowry, Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: implications for cancer induction., Radiology 245, 742-750 (2007). 10.1148/radiol.2453062046
    • (2007) Radiology , vol.245 , pp. 742-750
    • Hurwitz, L.M.1    Reiman, R.E.2    Yoshizumi, T.T.3    Goodman, P.C.4    Toncheva, G.5    Nguyen, G.6    Lowry, C.7
  • 4
    • 34648819024 scopus 로고    scopus 로고
    • Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols
    • 10.1097/RCT.0b013e31802d3dd2
    • L. M. Hurwitz, T. T. Yoshizumi, P. C. Goodman, D. P. Frush, G. Nguyen, G. Toncheva, and C. Lowry, Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols., J. Comput. Assist. Tomogr. 31, 544-549 (2007). 10.1097/RCT.0b013e31802d3dd2
    • (2007) J. Comput. Assist. Tomogr. , vol.31 , pp. 544-549
    • Hurwitz, L.M.1    Yoshizumi, T.T.2    Goodman, P.C.3    Frush, D.P.4    Nguyen, G.5    Toncheva, G.6    Lowry, C.7
  • 5
    • 0035990013 scopus 로고    scopus 로고
    • Comparisons of point and average organ dose within an anthropomorphic physical phantom and a computational model of the newborn patient
    • 10.1118/1.1481516
    • J. B. Sessions, J. N. Roshau, M. A. Tressler, D. E. Hintenlang, M. M. Arreola, J. L. Williams, L. G. Bouchet, and W. E. Bolch, Comparisons of point and average organ dose within an anthropomorphic physical phantom and a computational model of the newborn patient., Med. Phys. 29, 1080-1089 (2002). 10.1118/1.1481516
    • (2002) Med. Phys. , vol.29 , pp. 1080-1089
    • Sessions, J.B.1    Roshau, J.N.2    Tressler, M.A.3    Hintenlang, D.E.4    Arreola, M.M.5    Williams, J.L.6    Bouchet, L.G.7    Bolch, W.E.8
  • 6
    • 33748315075 scopus 로고    scopus 로고
    • A tomographic physical phantom of the newborn child with real-time dosimetry. II. Scaling factors for calculation of mean organ dose in pediatric radiography
    • 10.1118/1.2256687
    • R. J. Staton, A. K. Jones, C. Lee, D. E. Hintenlang, M. M. Arreola, J. L. Williams, and W. E. Bolch, A tomographic physical phantom of the newborn child with real-time dosimetry. II. Scaling factors for calculation of mean organ dose in pediatric radiography., Med. Phys. 33, 3283-3289 (2006). 10.1118/1.2256687
    • (2006) Med. Phys. , vol.33 , pp. 3283-3289
    • Staton, R.J.1    Jones, A.K.2    Lee, C.3    Hintenlang, D.E.4    Arreola, M.M.5    Williams, J.L.6    Bolch, W.E.7
  • 7
    • 34247606356 scopus 로고    scopus 로고
    • Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: Comparison with thermoluminescent dosimetry
    • 10.2214/AJR.06.0742
    • T. T. Yoshizumi, P. C. Goodman, D. P. Frush, G. Nguyen, G. Toncheva, M. Sarder, and L. Barnes, Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: Comparison with thermoluminescent dosimetry., AJR, Am. J. Roentgenol. 188, 1332-1336 (2007). 10.2214/AJR.06.0742
    • (2007) AJR, Am. J. Roentgenol. , vol.188 , pp. 1332-1336
    • Yoshizumi, T.T.1    Goodman, P.C.2    Frush, D.P.3    Nguyen, G.4    Toncheva, G.5    Sarder, M.6    Barnes, L.7
  • 8
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter
    • 10.1118/1.597314
    • M. Soubra, J. Cygler, and G. Mackay, Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter., Med. Phys. 21, 567-572 (1994). 10.1118/1.597314
    • (1994) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    MacKay, G.3
  • 10
    • 78649746437 scopus 로고    scopus 로고
    • Absorbed radiation dose in radiosensitive organs during coronary CT angiography using 320-MDCT: Effect of maximum tube voltage and heart rate variations
    • 10.2214/AJR.10.4333
    • B. Nikolic, F. Khosa, P. J. Lin, A. N. Khan, S. Sarwar, C. S. Yam, L. E. Court, V. Raptopoulos, and M. E. Clouse, Absorbed radiation dose in radiosensitive organs during coronary CT angiography using 320-MDCT: Effect of maximum tube voltage and heart rate variations., AJR, Am. J. Roentgenol. 195, 1347-1354 (2010). 10.2214/AJR.10.4333
    • (2010) AJR, Am. J. Roentgenol. , vol.195 , pp. 1347-1354
    • Nikolic, B.1    Khosa, F.2    Lin, P.J.3    Khan, A.N.4    Sarwar, S.5    Yam, C.S.6    Court, L.E.7    Raptopoulos, V.8    Clouse, M.E.9
  • 11
    • 33947189982 scopus 로고    scopus 로고
    • Abdominal multislice CT for obese patients: Effect on image quality and radiation dose in a phantom study
    • 10.1016/j.acra.2007.01.030
    • S. T. Schindera, R. C. Nelson, E. R. Lee, D. M. Delong, G. Ngyen, G. Toncheva, and T. T. Yoshizumi, Abdominal multislice CT for obese patients: effect on image quality and radiation dose in a phantom study., Acad. Radiol. 14, 486-494 (2007). 10.1016/j.acra.2007.01.030
    • (2007) Acad. Radiol. , vol.14 , pp. 486-494
    • Schindera, S.T.1    Nelson, R.C.2    Lee, E.R.3    Delong, D.M.4    Ngyen, G.5    Toncheva, G.6    Yoshizumi, T.T.7
  • 12
    • 79251479069 scopus 로고    scopus 로고
    • Direct quantification of breast dose during coronary CT angiography and evaluation of dose reduction strategies
    • 10.2214/AJR.10.4626
    • S. Abadi, H. Mehrez, A. Ursani, M. Parker, and N. Paul, Direct quantification of breast dose during coronary CT angiography and evaluation of dose reduction strategies., AJR, Am. J. Roentgenol. 196, W152-W158 (2011). 10.2214/AJR.10.4626
    • (2011) AJR, Am. J. Roentgenol. , vol.196
    • Abadi, S.1    Mehrez, H.2    Ursani, A.3    Parker, M.4    Paul, N.5
  • 13
    • 77956308118 scopus 로고    scopus 로고
    • Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures
    • 10.1118/1.3476455
    • S. Brady, T. Yoshizumi, G. Toncheva, and D. Frus, Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures., Med. Phys. 37, 4782-4792 (2010). 10.1118/1.3476455
    • (2010) Med. Phys. , vol.37 , pp. 4782-4792
    • Brady, S.1    Yoshizumi, T.2    Toncheva, G.3    Frus, D.4
  • 14
    • 84863529362 scopus 로고    scopus 로고
    • Free in air characterization of metal oxide semiconductor field effect transistor (MOSFET) dosimeters using computed tomography radiation beam delivery system
    • 10.1118/1.2760424
    • I. Hussain, S. Anderson, B. Yee, and R. Kaufman, Free in air characterization of metal oxide semiconductor field effect transistor (MOSFET) dosimeters using computed tomography radiation beam delivery system., Med. Phys. 34, 2348 (2007). 10.1118/1.2760424
    • (2007) Med. Phys. , vol.34 , pp. 2348
    • Hussain, I.1    Anderson, S.2    Yee, B.3    Kaufman, R.4
  • 15
    • 84863502413 scopus 로고    scopus 로고
    • Characterizing metal oxide semiconductor field effect transistor (MOSFET) radiaiton detectors in a scatter medium using CT radiation beam delivery system
    • 10.1118/1.3182426
    • I. H. Bercha, A. Maghsoodpour, G. Keyes, and R. Kaufman, Characterizing metal oxide semiconductor field effect transistor (MOSFET) radiaiton detectors in a scatter medium using CT radiation beam delivery system., Med. Phys. 36, 2747 (2009). 10.1118/1.3182426
    • (2009) Med. Phys. , vol.36 , pp. 2747
    • Bercha, I.H.1    Maghsoodpour, A.2    Keyes, G.3    Kaufman, R.4
  • 16
    • 0036888598 scopus 로고    scopus 로고
    • Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF:Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology
    • 10.1016/S0969-8043(02)00235-X
    • S. L. Dong, T. C. Chu, G. Y. Lan, T. H. Wu, Y. C. Lin, and J. S. Lee, Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF:Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology., Appl. Radiat. Isot. 57, 883-891 (2002). 10.1016/S0969-8043(02)00235-X
    • (2002) Appl. Radiat. Isot. , vol.57 , pp. 883-891
    • Dong, S.L.1    Chu, T.C.2    Lan, G.Y.3    Wu, T.H.4    Lin, Y.C.5    Lee, J.S.6
  • 17
    • 13644255923 scopus 로고    scopus 로고
    • Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV
    • 10.1088/0031-9155/50/2/008
    • C. Ehringfeld, S. Schmid, K. Poljanc, C. Kirisits, H. Aiginger, and D. Georg, Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV., Phys. Med. Biol. 50, 289-303 (2005). 10.1088/0031-9155/50/2/008
    • (2005) Phys. Med. Biol. , vol.50 , pp. 289-303
    • Ehringfeld, C.1    Schmid, S.2    Poljanc, K.3    Kirisits, C.4    Aiginger, H.5    Georg, D.6
  • 18
    • 0034973266 scopus 로고    scopus 로고
    • AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology
    • 10.1118/1.1374247
    • C. M. Ma, C. W. Coffey, L. A. DeWerd, C. Liu, R. Nath, S. M. Seltzer, and J. P. Seuntjens, AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology., Med. Phys. 28, 868-893 (2001). 10.1118/1.1374247
    • (2001) Med. Phys. , vol.28 , pp. 868-893
    • Ma, C.M.1    Coffey, C.W.2    Dewerd, L.A.3    Liu, C.4    Nath, R.5    Seltzer, S.M.6    Seuntjens, J.P.7
  • 19
    • 0035073371 scopus 로고    scopus 로고
    • Comparison of angular free-in-air and tissue-equivalent phantom response measurements in p-MOSFET dosimeters
    • 10.1097/00004032-200105000-00011
    • B. D. Pomije, C. H. Huh, M. A. Tressler, D. E. Hintenlang, and W. E. Bolch, Comparison of angular free-in-air and tissue-equivalent phantom response measurements in p-MOSFET dosimeters., Health Phys. 80, 497-505 (2001). 10.1097/00004032-200105000-00011
    • (2001) Health Phys. , vol.80 , pp. 497-505
    • Pomije, B.D.1    Huh, C.H.2    Tressler, M.A.3    Hintenlang, D.E.4    Bolch, W.E.5
  • 20
    • 2442646488 scopus 로고    scopus 로고
    • Monte Carlo modeling of a high-sensitivity MOSFET dosimeter for low- and medium-energy photon sources
    • 10.1118/1.1688272
    • B. Wang, C. H. Kim, and X. G. Xua, Monte Carlo modeling of a high-sensitivity MOSFET dosimeter for low- and medium-energy photon sources., Med. Phys. 31, 1003-1008 (2004). 10.1118/1.1688272
    • (2004) Med. Phys. , vol.31 , pp. 1003-1008
    • Wang, B.1    Kim, C.H.2    Xua, X.G.3
  • 21
    • 33749392945 scopus 로고    scopus 로고
    • Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and 60 Co
    • 10.1118/1.2349301
    • M. C. Lavallee, L. Gingras, and L. Beaulieu, Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and 60 Co., Med. Phys. 33, 3683-3689 (2006). 10.1118/1.2349301
    • (2006) Med. Phys. , vol.33 , pp. 3683-3689
    • Lavallee, M.C.1    Gingras, L.2    Beaulieu, L.3
  • 22
    • 84863508511 scopus 로고    scopus 로고
    • Variation of MOSFET calibration factor as a function of dosimeter age
    • 10.1118/1.3468100
    • G. Toncheva, M. Fredrickson, and T. T. Yoshizumi, Variation of MOSFET calibration factor as a function of dosimeter age., Med. Phys. 37, 3116-3117 (2010). 10.1118/1.3468100
    • (2010) Med. Phys. , vol.37 , pp. 3116-3117
    • Toncheva, G.1    Fredrickson, M.2    Yoshizumi, T.T.3
  • 24
    • 31044451240 scopus 로고    scopus 로고
    • A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT
    • 10.1118/1.2148916
    • J. H. Siewerdsen, M. J. Daly, B. Bakhtiar, D. J. Moseley, S. Richard, H. Keller, and D. A. Jaffray, A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT., Med. Phys. 33, 187-197 (2006). 10.1118/1.2148916
    • (2006) Med. Phys. , vol.33 , pp. 187-197
    • Siewerdsen, J.H.1    Daly, M.J.2    Bakhtiar, B.3    Moseley, D.J.4    Richard, S.5    Keller, H.6    Jaffray, D.A.7
  • 25
    • 0019948998 scopus 로고
    • The build-up of backscatter in the energy range 1 mm Al to 8 mm Al HVT
    • 10.1088/0031-9155/27/8/005
    • S. C. Klevenhagen, The build-up of backscatter in the energy range 1 mm Al to 8 mm Al HVT., Phys. Med. Biol. 27, 1035-1043 (1982). 10.1088/0031-9155/27/ 8/005
    • (1982) Phys. Med. Biol. , vol.27 , pp. 1035-1043
    • Klevenhagen, S.C.1
  • 26
    • 0031812771 scopus 로고    scopus 로고
    • Superficial and orthovoltage x-ray beam dosimetry
    • 10.1118/1.598309
    • E. Podgorsak, M. Gosselin, and M. Evans, Superficial and orthovoltage x-ray beam dosimetry., Med. Phys. 25, 1206-1211 (1998). 10.1118/1.598309
    • (1998) Med. Phys. , vol.25 , pp. 1206-1211
    • Podgorsak, E.1    Gosselin, M.2    Evans, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.