메뉴 건너뛰기




Volumn 49, Issue 1, 2012, Pages 82-87

Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2

Author keywords

[No Author keywords available]

Indexed keywords

AB INITIO CALCULATIONS; ATOMIC WAVE PACKETS; FREQUENCY BIAS; FREQUENCY ERRORS; FREQUENCY MEASUREMENTS; FREQUENCY SHIFT; MICROWAVE AMPLITUDE; PHASE FREQUENCY; PHYSIKALISCH-TECHNISCHE BUNDESANSTALT; SYSTEMATIC UNCERTAINTIES;

EID: 84863393888     PISSN: 00261394     EISSN: 16817575     Source Type: Journal    
DOI: 10.1088/0026-1394/49/1/012     Document Type: Article
Times cited : (88)

References (22)
  • 1
    • 84863402362 scopus 로고    scopus 로고
    • BIPM Circular T, monthly, available at
    • BIPM Circular T, monthly, available at: http://www.bipm.org/jsp/en/ TimeFtp.jsp
  • 2
    • 21044457967 scopus 로고    scopus 로고
    • Atomic fountain clocks
    • Wynands R and Weyers S 2005 Atomic fountain clocks Metrologia 42 S64-79
    • (2005) Metrologia , vol.42 , Issue.3
    • Wynands, R.1    Weyers, S.2
  • 3
    • 77957852680 scopus 로고    scopus 로고
    • Evaluating and minimizing distributed cavity phase errors in atomic clocks
    • Li R and Gibble K 2010 Evaluating and minimizing distributed cavity phase errors in atomic clocks Metrologia 47 534-51
    • (2010) Metrologia , vol.47 , Issue.5 , pp. 534-551
    • Li, R.1    Gibble, K.2
  • 4
    • 80053191152 scopus 로고    scopus 로고
    • Evaluation of Doppler shifts to improve the accuracy of primary atomic fountain clocks
    • Guéna J, Li R, Gibble K, Bize S and Clairon A 2011 Evaluation of Doppler shifts to improve the accuracy of primary atomic fountain clocks Phys. Rev. Lett. 106 130801
    • (2011) Phys. Rev. Lett. , vol.106 , Issue.13 , pp. 130801
    • Guéna, J.1    Li, R.2    Gibble, K.3    Bize, S.4    Clairon, A.5
  • 5
    • 80053177118 scopus 로고    scopus 로고
    • Improved accuracy of the NPL-CsF2 primary frequency standard: Evaluation of distributed cavity phase and microwave lensing frequency shifts
    • Li R, Gibble K and Szymaniec K 2011 Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts Metrologia 48 283-9
    • (2011) Metrologia , vol.48 , Issue.5 , pp. 283-289
    • Li, R.1    Gibble, K.2    Szymaniec, K.3
  • 6
    • 11044239222 scopus 로고    scopus 로고
    • Phase variations in microwave cavities for atomic clocks
    • DOI 10.1088/0026-1394/41/6/004, PII S0026139404856548
    • Li R and Gibble K 2004 Phase variations in microwave cavities for atomic clocks Metrologia 41 376-86 (Pubitemid 40043975)
    • (2004) Metrologia , vol.41 , Issue.6 , pp. 376-386
    • Li, R.1    Gibble, K.2
  • 9
    • 33747289338 scopus 로고    scopus 로고
    • Difference between a photon's momentum and an atom's recoil
    • Gibble K 2006 Difference between a photon's momentum and an atom's recoil Phys. Rev. Lett. 97 073002
    • (2006) Phys. Rev. Lett. , vol.97 , Issue.7 , pp. 073002
    • Gibble, K.1
  • 11
    • 0032269037 scopus 로고    scopus 로고
    • Performance of the PTB reconstructed primary clock CS1 and an estimate of its current uncertainty
    • Bauch A, Fischer B, Heindorff T and Schröder R 1998 Performance of the PTB reconstructed primary clock CS1 and an estimate of its current uncertainty Metrologia 35 829-45 (Pubitemid 128677964)
    • (1998) Metrologia , vol.35 , Issue.6 , pp. 829-845
    • Bauch, A.1    Fischer, B.2    Heindorff, T.3    Schroder, R.4
  • 12
    • 0036949947 scopus 로고    scopus 로고
    • Accuracy evaluation of NIST-F1
    • Jefferts S R et al 2002 Accuracy evaluation of NIST-F1 Metrologia 39 321-36
    • (2002) Metrologia , vol.39 , Issue.4 , pp. 321-336
    • Jefferts, S.R.1
  • 13
    • 33846585603 scopus 로고    scopus 로고
    • Distributed cavity phase and the associated power dependence
    • DOI 10.1109/FREQ.2005.1573909, 1573909, 2005 Joint IEEE International Frequency Controlo Symposium (FCS) and Precise Tome and Time INterval (PTTI) Systems and Applications Meeting
    • Li R and Gibble K 2005 Distributed cavity phase and the associated power dependence Proc. Joint IEEE Int. Frequency Control Symp. and Precise Time and Time Interval Systems and Applications Meeting (Vancouver, BC, Canada) pp 99-104 (Pubitemid 46170939)
    • (2005) Proceedings of the IEEE International Frequency Control Symposium and Exposition , vol.2005 , pp. 99-104
    • Li, R.1    Gibble, K.2
  • 18
    • 0035217651 scopus 로고    scopus 로고
    • Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
    • DOI 10.1088/0026-1394/38/4/7
    • Weyers S, Hübner U, Schröder R, Tamm Chr and Bauch A 2001 Uncertainty evaluation of the atomic caesium fountain CSF1 of PTB Metrologia 38 343-52 (Pubitemid 33149222)
    • (2001) Metrologia , vol.38 , Issue.4 , pp. 343-352
    • Weyers, S.1    Hubner, U.2    Schroder, R.3    Tamm, C.4    Bauch, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.