Volumn 2005, Issue , 2005, Pages 99-104

Distributed cavity phase and the associated power dependence

Author keywords

[No Author keywords available]

Indexed keywords

CAVITY RESONATORS; ELECTRIC VARIABLES MEASUREMENT; MEASUREMENT ERRORS; MICROWAVES;

EID: 33846585603     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/FREQ.2005.1573909     Document Type: Conference Paper
Times cited : (13)

References (14)
  • 1
    • 1542304145 scopus 로고
    • Measurement of the frequency shift due to distributed cavity phase difference in an atomic clock
    • A. Bauch, T. Heindorff, and R. Schroeder, "Measurement of the frequency shift due to distributed cavity phase difference in an atomic clock," IEEE Trans. Instrum. Meas., vol. 34, 1985, pp. 136-138.
    • (1985) IEEE Trans. Instrum. Meas , vol.34 , pp. 136-138
    • Bauch, A.1    Heindorff, T.2    Schroeder, R.3
  • 2
    • 11044239222 scopus 로고    scopus 로고
    • Phase variations in microwave cavities for atomic clocks
    • R. Li and K. Gibble, "Phase variations in microwave cavities for atomic clocks" Metrologia, vol. 41, pp. 376-386, 2004.
    • (2004) Metrologia , vol.41 , pp. 376-386
    • Li, R.1    Gibble, K.2
  • 3
    • 84983154343 scopus 로고    scopus 로고
    • Microwave cavities for atomic clocks: Phase variations and associated power dependences
    • Besancon, in press
    • R. Li and K. Gibble, "Microwave cavities for atomic clocks: phase variations and associated power dependences," 2005 Proc. 19th Eur. Frequency and Time Forum (Besancon), in press.
    • (2005) Proc. 19th Eur. Frequency and Time Forum
    • Li, R.1    Gibble, K.2
  • 4
    • 0029696210 scopus 로고    scopus 로고
    • Theoretical description and experimental evaluation of the effect of the interrogation oscillator frequency noise on the stability of a pulsed atomic frequency standard
    • G. Santarelli, P. Laurent, A. Clairon, G.J. Dick, C.A. Greenhall and C. Audoin, "Theoretical description and experimental evaluation of the effect of the interrogation oscillator frequency noise on the stability of a pulsed atomic frequency standard," Proc. Eur. Frequency and Time Forum, vol. 45, 1996, pp. 66-71.
    • (1996) Proc. Eur. Frequency and Time Forum , vol.45 , pp. 66-71
    • Santarelli, G.1    Laurent, P.2    Clairon, A.3    Dick, G.J.4    Greenhall, C.A.5    Audoin, C.6
  • 6
    • 1542334175 scopus 로고    scopus 로고
    • Evaluation des performances de la fontaine atomique PHARAO, Participation à l'étude de l'horloge spatiale PHARAO
    • Ph.D. thesis
    • M. Abgrall, "Evaluation des performances de la fontaine atomique PHARAO, Participation à l'étude de l'horloge spatiale PHARAO", Ph.D. thesis, 2003, p. 147.
    • (2003) , pp. 147
    • Abgrall, M.1
  • 7
    • 84908664877 scopus 로고    scopus 로고
    • On the power dependence of extranenous microwave fields in atomic frequency standardes, in these prodeedings
    • in press
    • S. R. Jefferts, J. H. Shirley, E. A. Donley, T. P. Heavner an T.E. Parker, "On the power dependence of extranenous microwave fields in atomic frequency standardes," in these prodeedings, in press.
    • Jefferts, S.R.1    Shirley, J.H.2    Donley, E.A.3    Heavner an, T.P.4    Parker, T.E.5
  • 9
    • 32844460338 scopus 로고    scopus 로고
    • Power Dependence of Distributed Cavity Phase Induced Frequency Biases in Atomic Fountain Frequency Standards, 2005 IEEE Trans. Ultrason. Ferr
    • See also, in press
    • See also S. R. Jefferts, J. H. Shirley, E. A. Burt, and G. J. Dick, "Power Dependence of Distributed Cavity Phase Induced Frequency Biases in Atomic Fountain Frequency Standards," 2005 IEEE Trans. Ultrason. Ferr. in press.
    • Jefferts, S.R.1    Shirley, J.H.2    Burt, E.A.3    Dick, G.J.4
  • 12
    • 10144257870 scopus 로고    scopus 로고
    • Advances in atomic fountains
    • S. Bize et al., "Advances in atomic fountains," C. R. Physique vol. 5 829-843, (2004).
    • (2004) C. R. Physique , vol.5 , pp. 829-843
    • Bize, S.1
  • 13
    • 0035217651 scopus 로고    scopus 로고
    • Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
    • S. Weyers, U. Hubner, R. Schroder, C. Tamm, A. Bauch, "Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB," Metrologia vol. 38 343-352 (2001).
    • (2001) Metrologia , vol.38 , pp. 343-352
    • Weyers, S.1    Hubner, U.2    Schroder, R.3    Tamm, C.4    Bauch, A.5