메뉴 건너뛰기




Volumn 27, Issue 2, 2012, Pages 132-140

Evaluation of three hollow-fiber membrane oxygenators without integrated arterial filters for neonatal cardiopulmonary bypass

Author keywords

cardiopulmonary bypass; emboli; hemodynamics; hollow fiber membrane oxygenator; neonatal; purge line flow

Indexed keywords

RINGER LACTATE SOLUTION;

EID: 84863358445     PISSN: 02676591     EISSN: 1477111X     Source Type: Journal    
DOI: 10.1177/0267659111430560     Document Type: Article
Times cited : (21)

References (8)
  • 1
    • 77950906582 scopus 로고    scopus 로고
    • Brain protection during pediatric cardiopulmonary bypass
    • Su XW, Ündar A. Brain protection during pediatric cardiopulmonary bypass. Artificial Organs. 2010 ; 34: 91-102
    • (2010) Artificial Organs , vol.34 , pp. 91-102
    • Su, X.W.1    Ündar, A.2
  • 3
    • 46249109869 scopus 로고    scopus 로고
    • Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperature
    • Schreiner RS, Rider AR, Myers JW, et al. Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperature. ASAIO J. 2008 ; 54: 316-324
    • (2008) ASAIO J , vol.54 , pp. 316-324
    • Schreiner, R.S.1    Rider, A.R.2    Myers, J.W.3
  • 4
    • 51149120650 scopus 로고    scopus 로고
    • "Stolen" blood flow: The effects of an open arterial filter purge line in a simulated neonatal CPB model
    • Wang S, Miller A, Myers JL, Ündar A. "Stolen" blood flow: the effects of an open arterial filter purge line in a simulated neonatal CPB model. ASAIO J. 2008 ; 54: 432-435
    • (2008) ASAIO J , vol.54 , pp. 432-435
    • Wang, S.1    Miller, A.2    Myers, J.L.3    Ündar, A.4
  • 5
    • 34548834165 scopus 로고    scopus 로고
    • Gaseous Microemboli Sizing in Extracorporeal Circuits Using Ultrasound Backscatter
    • DOI 10.1016/j.ultrasmedbio.2007.04.008, PII S0301562907002049
    • Lynch JE, Pouch A, Sanders R, Hinders M, Rudd K, Sevick J. Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter. Ultrasound in Med & Biol. 2007 ; 33: 1661-1675 (Pubitemid 47444479)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.10 , pp. 1661-1675
    • Lynch, J.E.1    Pouch, A.2    Sanders, R.3    Hinders, M.4    Rudd, K.5    Sevick, J.6
  • 7
    • 62449261047 scopus 로고    scopus 로고
    • Hemodynamic energy delivery of the pulsatile flow in a simulated pediatric extracorporeal circuit
    • Wang S, Haines N, Undar A. Hemodynamic energy delivery of the pulsatile flow in a simulated pediatric extracorporeal circuit. ASAIO J. 2009 ; 55 (1). 96-99
    • (2009) ASAIO J , vol.55 , Issue.1 , pp. 96-99
    • Wang, S.1    Haines, N.2    Undar, A.3
  • 8
    • 70450250005 scopus 로고    scopus 로고
    • Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops
    • Guan Y, Palanzo D, Kunselman A, Ündar A. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops. Artificial Organs. 2009 ; 33: 1037-1043
    • (2009) Artificial Organs , vol.33 , pp. 1037-1043
    • Guan, Y.1    Palanzo, D.2    Kunselman, A.3    Ündar, A.4