Volumn 14, Issue 6, 2012, Pages 343-346

Implantable cardioverter defibrillator with and without defibrillation threshold testing

Author keywords

Anti tachycardia pacing (ATP); Defibrillation threshold (DFT); Implantable cardioverter defibrillator (ICD); Sudden death; Ventricular fibrillation (VF); Ventricular tachycardia (VT)

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOGENIC SHOCK; COHORT ANALYSIS; COMPARATIVE STUDY; DEFIBRILLATION; DEFIBRILLATION THRESHOLD TESTING; DEFIBRILLATOR; FEMALE; FOLLOW UP; HEART DEATH; HEART PACING; HUMAN; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; MATERIALS TESTING; MORTALITY; OUTCOME ASSESSMENT; RETROSPECTIVE STUDY; TACHYCARDIA;

EID: 84863335209     PISSN: 15651088     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (24)
  • 1
    • 9844224486 scopus 로고    scopus 로고
    • A comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias
    • The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators
    • The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. N Engl J Med 1997; 337: 1576-83.
    • (1997) N Engl J Med , vol.337 , pp. 1576-1583
  • 2
    • 0038408832 scopus 로고    scopus 로고
    • Effectiveness of implantable defibrillators for preventing arrhythmic events and death: A meta-analysis
    • Lee DS, Green LD, Liu PP, et al. Effectiveness of implantable defibrillators for preventing arrhythmic events and death: a meta-analysis. J Am Coll Cardiol 2003; 41: 1573-82.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 1573-1582
    • Lee, D.S.1    Green, L.D.2    Liu, P.P.3
  • 3
    • 0021997027 scopus 로고
    • Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator
    • Echt DS, Armstrong K, Schmidt P, Oyer PE, Stinson EB, Winkle RA. Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. Circulation 1985; 71: 289-96.
    • (1985) Circulation , vol.71 , pp. 289-296
    • Echt, D.S.1    Armstrong, K.2    Schmidt, P.3    Oyer, P.E.4    Stinson, E.B.5    Winkle, R.A.6
  • 4
    • 44649093349 scopus 로고    scopus 로고
    • High defibrillation energy requirements are encountered rarely with modern dual-chamber implantable cardioverter-defibrillator systems
    • Day JD, Olshansky B, Moore S, Brown S, Stolen KQ, Lerew DR. High defibrillation energy requirements are encountered rarely with modern dual-chamber implantable cardioverter-defibrillator systems. Europace 2008; 10: 347-50.
    • (2008) Europace , vol.10 , pp. 347-350
    • Day, J.D.1    Olshansky, B.2    Moore, S.3    Brown, S.4    Stolen, K.Q.5    Lerew, D.R.6
  • 5
    • 0037197741 scopus 로고    scopus 로고
    • Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: Primary results from the low energy safety study (LESS)
    • Gold MR, Higgins S, Klein R, et al. Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the low energy safety study (LESS). Circulation 2002; 105: 2043-8.
    • (2002) Circulation , vol.105 , pp. 2043-2048
    • Gold, M.R.1    Higgins, S.2    Klein, R.3
  • 6
    • 39649116512 scopus 로고    scopus 로고
    • Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation
    • Lever NA, Newall EG, Larsen PD. Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation. Europace 2007; 9: 1054-8.
    • (2007) Europace , vol.9 , pp. 1054-1058
    • Lever, N.A.1    Newall, E.G.2    Larsen, P.D.3
  • 7
    • 39649085555 scopus 로고    scopus 로고
    • The top 10 reasons to avoid defibrillation threshold testing during ICD implantation
    • Viskin S, Rosso R. The top 10 reasons to avoid defibrillation threshold testing during ICD implantation. Heart Rhythm 2008; 5: 391-3.
    • (2008) Heart Rhythm , vol.5 , pp. 391-393
    • Viskin, S.1    Rosso, R.2
  • 8
    • 33747826289 scopus 로고    scopus 로고
    • Elevated defibrillation thresholds in patients undergoing biventricular defibrillator implantation: Incidence and predictors
    • Mainigi SK, Cooper JM, Russo AM, et al. Elevated defibrillation thresholds in patients undergoing biventricular defibrillator implantation: incidence and predictors. Heart Rhythm 2006; 3: 1010-16.
    • (2006) Heart Rhythm , vol.3 , pp. 1010-1016
    • Mainigi, S.K.1    Cooper, J.M.2    Russo, A.M.3
  • 9
    • 48449087090 scopus 로고    scopus 로고
    • Defibrillation threshold testing in implantable cardioverterdefibrillators: Might less be more than enough
    • Curtis AB. Defibrillation threshold testing in implantable cardioverterdefibrillators: might less be more than enough. J Am Coll Cardiol 2008; 52: 557-8.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 557-558
    • Curtis, A.B.1
  • 10
    • 39649088013 scopus 로고    scopus 로고
    • Complications associated with defibrillation threshold testing: The Canadian experience
    • Birnie D, Tung S, Simpson C, et al. Complications associated with defibrillation threshold testing: the Canadian experience. Heart Rhythm 2008; 5: 387-90.
    • (2008) Heart Rhythm , vol.5 , pp. 387-390
    • Birnie, D.1    Tung, S.2    Simpson, C.3
  • 11
    • 34547887245 scopus 로고    scopus 로고
    • Defibrillation testing at the time of implantation of cardioverter defibrillator in the clinical practice: A nation-wide survey
    • Brignole M, Raciti G, Bongiorni MG, et al. Defibrillation testing at the time of implantation of cardioverter defibrillator in the clinical practice: a nation-wide survey. Europace 2007; 9: 540-3.
    • (2007) Europace , vol.9 , pp. 540-543
    • Brignole, M.1    Raciti, G.2    Bongiorni, M.G.3
  • 12
    • 15644375417 scopus 로고    scopus 로고
    • Effect of ventricular shock strength on cardiac hemodynamics
    • Tokano T, Bach D, Chang J, et al. Effect of ventricular shock strength on cardiac hemodynamics. J Cardiovasc Electrophysiol 1998; 9: 791-7.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 791-797
    • Tokano, T.1    Bach, D.2    Chang, J.3
  • 13
    • 0031009221 scopus 로고    scopus 로고
    • Myocardial injury after electrical therapy for cardiac arrhythmias assessed by troponin-T release
    • Runsiö M, Kallner A, Källner G, et al. Myocardial injury after electrical therapy for cardiac arrhythmias assessed by troponin-T release. Am J Cardiol 1997; 79: 1241-5.
    • (1997) Am J Cardiol , vol.79 , pp. 1241-1245
    • Runsiö, M.1    Kallner, A.2    Källner, G.3
  • 14
    • 0012556209 scopus 로고    scopus 로고
    • Myocardial cell damage after repeated ICD therapies demonstrated by circulating cardiac specific proteins
    • Stix G, Hirschl M, Vukovich T, et al. Myocardial cell damage after repeated ICD therapies demonstrated by circulating cardiac specific proteins. PACE 1998; 21: 910.
    • (1998) PACE , vol.21 , pp. 910
    • Stix, G.1    Hirschl, M.2    Vukovich, T.3
  • 15
    • 48449094224 scopus 로고    scopus 로고
    • For the SCD-HeFT Investigators. No benefit from defibrillation threshold testing in the Sudden Cardiac Death in Heart Failure Trial
    • Blatt JA, Poole JE, Johnson GW, et al. for the SCD-HeFT Investigators. No benefit from defibrillation threshold testing in the Sudden Cardiac Death in Heart Failure Trial. J Am Coll Cardiol 2008; 52: 551-6.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 551-556
    • Blatt, J.A.1    Poole, J.E.2    Johnson, G.W.3
  • 16
    • 65649083360 scopus 로고    scopus 로고
    • Primary prevention implantation of cardioverter defibrillator without defibrillation threshold testing: 2-year follow-up
    • Bianchi S, Ricci RP, Biscione F, et al. Primary prevention implantation of cardioverter defibrillator without defibrillation threshold testing: 2-year follow-up. PACE 2009; 32: 573-8.
    • (2009) PACE , vol.32 , pp. 573-578
    • Bianchi, S.1    Ricci, R.P.2    Biscione, F.3
  • 17
    • 71849086249 scopus 로고    scopus 로고
    • Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: Do we really need it?
    • Calvi V, Dugo D, Capodanno D, et al. Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: do we really need it? Am Heart J 2010; 159: 98-102.
    • (2010) Am Heart J , vol.159 , pp. 98-102
    • Calvi, V.1    Dugo, D.2    Capodanno, D.3
  • 18
    • 3242794231 scopus 로고    scopus 로고
    • Is defibrillation testing required for defibrillator implantation?
    • Strickberger SA, Klein GJ. Is defibrillation testing required for defibrillator implantation? J Am Coll Cardiol 2004; 44: 88-91.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 88-91
    • Strickberger, S.A.1    Klein, G.J.2
  • 19
    • 77749320077 scopus 로고    scopus 로고
    • Does defibrillation threshold increase as left ventricular ejection fraction decreases?
    • Val-Mejias JE, Oza A. Does defibrillation threshold increase as left ventricular ejection fraction decreases? Europace 2010; 12: 385-8.
    • (2010) Europace , vol.12 , pp. 385-388
    • Val-Mejias, J.E.1    Oza, A.2
  • 20
    • 33747070573 scopus 로고    scopus 로고
    • Effect of amiodarone and sotalol on ventricular defibrillation threshold. The optimal pharmacological therapy in cardioverter defibrillator patients (OPTIC) trial
    • Hohnloser SH, Dorian P, Roberts R, et al. Effect of amiodarone and sotalol on ventricular defibrillation threshold. The optimal pharmacological therapy in cardioverter defibrillator patients (OPTIC) trial. Circulation 2006; 114: 104-9.
    • (2006) Circulation , vol.114 , pp. 104-109
    • Hohnloser, S.H.1    Dorian, P.2    Roberts, R.3
  • 21
    • 33644784089 scopus 로고    scopus 로고
    • VENTAK CHF/CONTAK CD Study Investigators. Defibrillation energy requirements in an ICD population receiving cardiac resynchronization therapy
    • Schuger C, Ellenbogen K, Faddis M, Knight BP, Young P, Sample R; VENTAK CHF/CONTAK CD Study Investigators. Defibrillation energy requirements in an ICD population receiving cardiac resynchronization therapy. J Cardiovasc Electrophysiol 2006; 17: 247-50.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 247-250
    • Schuger, C.1    Ellenbogen, K.2    Faddis, M.3    Knight, B.P.4    Young, P.5    Sample, R.6
  • 22
    • 20244387585 scopus 로고    scopus 로고
    • Defibrillation threshold testing: Is it really necessary at the time of implantable cardioverter-defibrillator insertion?
    • Russo AM, Sauer W, Gerstenfeld EP, et al. Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion? Heart Rhythm 2005; 2: 456-61.
    • (2005) Heart Rhythm , vol.2 , pp. 456-461
    • Russo, A.M.1    Sauer, W.2    Gerstenfeld, E.P.3
  • 23
    • 0037197741 scopus 로고    scopus 로고
    • Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: Primary results from the low energy safety study (LESS)
    • Gold MR, Higgins S, Klein R, et al. Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the low energy safety study (LESS). Circulation 2002; 105: 2043-8.
    • (2002) Circulation , vol.105 , pp. 2043-2048
    • Gold, M.R.1    Higgins, S.2    Klein, R.3
  • 24
    • 65649130785 scopus 로고    scopus 로고
    • Defibrillation threshold testing: Tradition or necessity?
    • Kolb C, Tzeis S, Zrenner B. Defibrillation threshold testing: tradition or necessity? PACE 2009; 32: 570-2.
    • (2009) PACE , vol.32 , pp. 570-572
    • Kolb, C.1    Tzeis, S.2    Zrenner, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.