메뉴 건너뛰기




Volumn 32, Issue 5, 2009, Pages 570-572

Defibrillation threshold testing: Tradition or necessity?

Author keywords

Defibrillation threshold testing; Implantable cardioverter defibrillator; Sudden cardiac death

Indexed keywords

DEFIBRILLATION; DEFIBRILLATOR; ENERGY; HEART PACING; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTATION; MORTALITY; PRIMARY PREVENTION; REVIEW; SECONDARY PREVENTION; SUDDEN DEATH; SURVIVAL;

EID: 65649130785     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2009.02328.x     Document Type: Review
Times cited : (30)

References (19)
  • 1
    • 33749239027 scopus 로고    scopus 로고
    • ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death
    • Zipes DP, Camm AJ, Borggrefe M, Buxton AE, Chaitman B, Fromer M, Gregoratos G, et al. ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Europace 2006 8 : 746 837.
    • (2006) Europace , vol.8 , pp. 746-837
    • Zipes, D.P.1    Camm, A.J.2    Borggrefe, M.3    Buxton, A.E.4    Chaitman, B.5    Fromer, M.6    Gregoratos, G.7
  • 3
    • 9644263976 scopus 로고    scopus 로고
    • Prophylactic implantable cardioverter-defibrillator therapy in patients with left ventricular systolic dysfunction: A pooled analysis of 10 primary prevention trials
    • DOI 10.1016/j.jacc.2004.08.054, PII S0735109704017449
    • Nanthakumar K, Epstein A, Kay N, Plumb VJ, Lee DS. Prophylactic implantable cardioverter-defibrillator therapy in patients with left ventricular systolic dysfunction. A pooled analysis of 10 primary prevention trials. J Am Coll Cardiol 2004 44 : 2166 2172. (Pubitemid 39576036)
    • (2004) Journal of the American College of Cardiology , vol.44 , Issue.11 , pp. 2166-2172
    • Nanthakumar, K.1    Epstein, A.E.2    Kay, G.N.3    Plumb, V.J.4    Lee, D.S.5
  • 4
    • 0023786718 scopus 로고
    • Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator
    • DOI 10.1016/0002-9149(88)90965-4
    • Marchlinski FE, Flores B, Miller JM, Gottlieb CD, Hargrove WC III. Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator. Am J Cardiol 1988 62 : 393 398. (Pubitemid 18207236)
    • (1988) American Journal of Cardiology , vol.62 , Issue.7 , pp. 393-398
    • Marchlinski, F.E.1    Flores, B.2    Miller, J.M.3    Gottlieb, C.D.4    Hargrove III, W.C.5
  • 6
    • 39649116512 scopus 로고    scopus 로고
    • Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation
    • Lever NA, Newall EG, Larsen PD. Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation. Europace 2007 9 : 1054 1058.
    • (2007) Europace , vol.9 , pp. 1054-1058
    • Lever, N.A.1    Newall, E.G.2    Larsen, P.D.3
  • 7
    • 0037188571 scopus 로고    scopus 로고
    • Impact of myocardial ischemia and reperfusion on ventricular defibrillation patterns, energy requirements, and detection of recovery
    • Qin H, Walcott GP, Killingsworth CR, Rollins DL, Smith WM, Ideker RE. Impact of myocardial ischemia and reperfusion on ventricular defibrillation patterns, energy requirements, and detection of recovery. Circulation 2002 105 : 2537 2542.
    • (2002) Circulation , vol.105 , pp. 2537-2542
    • Qin, H.1    Walcott, G.P.2    Killingsworth, C.R.3    Rollins, D.L.4    Smith, W.M.5    Ideker, R.E.6
  • 8
    • 44649093349 scopus 로고    scopus 로고
    • High defibrillation energy requirements are encountered rarely with modern dual-chamber implantable cardioverter-defibrillator systems
    • INTRINSIC RV Study Investigators.
    • Day JD, Olshansky B, Moore S, Brown S, Stolen KQ, Lerew DR, INTRINSIC RV Study Investigators. High defibrillation energy requirements are encountered rarely with modern dual-chamber implantable cardioverter-defibrillator systems. Europace 2008 10 : 347 350.
    • (2008) Europace , vol.10 , pp. 347-350
    • Day, J.D.1    Olshansky, B.2    Moore, S.3    Brown, S.4    Stolen, K.Q.5    Lerew, D.R.6
  • 9
    • 33644784089 scopus 로고    scopus 로고
    • Defibrillation energy requirements in an ICD population receiving cardiac resynchronization therapy
    • DOI 10.1111/j.1540-8167.2006.00345.x
    • Schuger C, Ellenbogen K, Faddis M, Knight BP, Yong P, Sample R VENTAK CHF/CONTAK CD Study Investigators. Defibrillation energy requirements in an ICD population receiving cardiac resynchronization therapy. J Cardiovasc Electrophysiol 2006 17 : 247 250. (Pubitemid 43344931)
    • (2006) Journal of Cardiovascular Electrophysiology , vol.17 , Issue.3 , pp. 247-250
    • Schuger, C.1    Ellenbogen, K.A.2    Faddis, M.3    Knight, B.P.4    Yong, P.5    Sample, R.6
  • 11
    • 0037197741 scopus 로고    scopus 로고
    • Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: Primary results from the Low Energy Safety Study (LESS)
    • DOI 10.1161/01.CIR.0000015508.59749.F5
    • Gold MR, Higgins S, Klein R, Gilliam FR, Kopelman H, Hessen S, Payne J, et al. Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: Primary results from the low energy safety study (LESS). Circulation 2002 105 : 2043 2048. (Pubitemid 34465266)
    • (2002) Circulation , vol.105 , Issue.17 , pp. 2043-2048
    • Gold, M.R.1    Higgins, S.2    Klein, R.3    Gilliam, F.R.4    Kopelman, H.5    Hessen, S.6    Payne, J.7    Strickberger, S.A.8    Breiter, D.9    Hahn, S.10
  • 13
    • 0032921461 scopus 로고    scopus 로고
    • The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in human
    • Windecker S, Ideker RE, Plumb VJ, Kay GN, Walcott GP, Epstein AE. The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in human. J Am Coll Cardiol 1998 33 : 33 38.
    • (1998) J Am Coll Cardiol , vol.33 , pp. 33-38
    • Windecker, S.1    Ideker, R.E.2    Plumb, V.J.3    Kay, G.N.4    Walcott, G.P.5    Epstein, A.E.6
  • 14
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing fast ventricular tachycardia reduces shock therapies (PainFREE Rx II) trial results
    • DOI 10.1161/01.CIR.0000145610.64014.E4
    • Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, Canby RC, et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation 2004 110 : 2591 2596. (Pubitemid 39453007)
    • (2004) Circulation , vol.110 , Issue.17 , pp. 2591-2596
    • Wathen, M.S.1    DeGroot, P.J.2    Sweeney, M.O.3    Stark, A.J.4    Otterness, M.F.5    Adkisson, W.O.6    Canby, R.C.7    Khalighi, K.8    Machado, C.9    Rubenstein, D.S.10    Volosin, K.J.11
  • 16
    • 34547887245 scopus 로고    scopus 로고
    • Defibrillation testing at the time of implantation of cardioverter defibrillator in the clinical practice: A nation-wide survey
    • DOI 10.1093/europace/eum083
    • Brignole M, Raciti G, Bongiorni MG, De Martino G, Favale S, Gasparini M, Luise R, et al. Defibrillation testing at the time of implantation of cardioverter defibrillation in the clinical practice: A nation-wide survey. Europace 2007 9 : 540 543 (Pubitemid 47249446)
    • (2007) Europace , vol.9 , Issue.7 , pp. 540-543
    • Brignole, M.1    Raciti, G.2    Bongiorni, M.G.3    De Martino, G.4    Favale, S.5    Gasparini, M.6    Luise, R.7    Occhetta, E.8    Proclemer, A.9
  • 19
    • 0035052674 scopus 로고    scopus 로고
    • Ventricular fibrillation sensing and detection by implantable defibrillators: Is one better than the others? A prospective, comparative study
    • Panotopoulos P, Krum D, Axtell K, Dhala A, Sra J, Akhtar M, Deshpande S. Ventricular fibrillation sensing and detection by implantable defibrillators: Is one better than the others? A prospective, comparative study. J Cardiovasc Electrophysiol 2001 12 : 445 452. (Pubitemid 32324659)
    • (2001) Journal of Cardiovascular Electrophysiology , vol.12 , Issue.4 , pp. 445-452
    • Panotopoulos, P.1    Krum, D.2    Axtell, K.3    Dhala, A.4    Sra, J.5    Akhtar, M.6    Deshpande, S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.