-
1
-
-
34247095550
-
Recommendations for radioembolization of hepatic malignancies using yttrium-90 microsphere brachytherapy: A consensus panel report from the radioembolization brachytherapy oncology consortium
-
DOI 10.1016/j.ijrobp.2006.11.060, PII S0360301607000971
-
Kennedy, A., Nag, S., Salem, R., Murthy, R., McEwan, A. J., Nutting, C., Benson, A., Eespat, J., Bilbao, J. I., Sharma, R. A., Thomas, J. P., and Coldwell, D., 2007, Recommendations for Radioembolizations of Hepatic Malignancies Using Yttrium-90 Microsphere Brachytherapy: A Concensus Panel Report From the Radioembolization Brachytherapy Oncology Consortium., Int. J. Radiat. Oncol. Biol. Phys. (Red Journal), 68 (1), pp. 13-3. (Pubitemid 46589861)
-
(2007)
International Journal of Radiation Oncology Biology Physics
, vol.68
, Issue.1
, pp. 13-23
-
-
Kennedy, A.1
Nag, S.2
Salem, R.3
Murthy, R.4
McEwan, A.J.5
Nutting, C.6
Benson III, A.7
Espat, J.8
Bilbao, J.I.9
Sharma, R.A.10
Thomas, J.P.11
Coldwell, D.12
-
2
-
-
33646237122
-
90y-microsphere brachytherapy for unresectable colorectal liver metastases: Modern usa experience
-
90Y-Microsphere Brachytherapy for Unresectable Colorectal Liver Metastases: Modern USA Experience., Int. J. Radiat. Oncol. Biol. Phys. (Red Journal), 65 (2), pp. 412-425.
-
(2006)
Int. J. Radiat. Oncol. Biol. Phys. (Red Journal)
, vol.65
, Issue.2
, pp. 412-425
-
-
Kennedy, A.S.1
Coldwell, D.2
Nutting, C.3
Murthy, R.4
Wertman, Jr.D.E.5
Loeher, S.P.6
Overton, C.7
Meranze, S.8
Niedzwiecki, J.9
Sailer, S.10
-
3
-
-
77951478799
-
Radioembolization (yttrium-90 microspheres) for primary and metastatic hepatic malignancies
-
Kennedy, A. S., and Salem, R., 2010, Radioembolization (Yttrium-90 Microspheres) for Primary and Metastatic Hepatic Malignancies., Cancer J., 16 (2), pp. 163-175.
-
(2010)
Cancer J.
, vol.16
, Issue.2
, pp. 163-175
-
-
Kennedy, A.S.1
Salem, R.2
-
4
-
-
77952010016
-
-
U.S. Patent and PCT Int'l Application No. PCT/US2010/043552, NC State University, Raleigh, NC
-
Kleinstreuer, C., 2011, Methods and Devices for Targeted Injection of Radioactive Microspheres., U.S. Patent and PCT Int'l Application No. PCT/US2010/043552, NC State University, Raleigh, NC.
-
(2011)
Methods and Devices for Targeted Injection of Radioactive Microspheres
-
-
Kleinstreuer, C.1
-
5
-
-
77952008886
-
Computer modeling of controlled microsphere release and targeting in a representative hepatic artery system
-
Basciano, C. A., Kleinstreuer, C., Kennedy, A. S., Dezarn, W. A., and Childress, E., 2010, Computer Modeling of Controlled Microsphere Release and Targeting in a Representative Hepatic Artery System., Ann. Biomed. Eng., 38 (5), pp. 1862-1879.
-
(2010)
Ann. Biomed. Eng.
, vol.38
, Issue.5
, pp. 1862-1879
-
-
Basciano, C.A.1
Kleinstreuer, C.2
Kennedy, A.S.3
Dezarn, W.A.4
Childress, E.5
-
6
-
-
73649120614
-
90y microsphere transport in the hepatic arterial tree to improve clinical outcomes
-
90Y Microsphere Transport in the Hepatic Arterial Tree to Improve Clinical Outcomes., Int. J. Radiat. Oncol. Biol. Phys. (Red Journal), 76 (2), pp. 631-637.
-
(2010)
Int. J. Radiat. Oncol. Biol. Phys. (Red Journal)
, vol.76
, Issue.2
, pp. 631-637
-
-
Kennedy, A.1
Kleinstreuer, C.2
Basciano, C.A.3
Dezarn, A.4
-
7
-
-
85134444566
-
-
CRC, Taylor and Francis, Boca Raton, FL
-
Kleinstreuer, C., 2006, Biofluid Dynamics: Principles and Selected Applications, CRC, Taylor and Francis, Boca Raton, FL.
-
(2006)
Biofluid Dynamics: Principles and Selected Applications
-
-
Kleinstreuer, C.1
-
8
-
-
84863334502
-
Controversy in yttrium-90 selective internal radiation therapy: Imaging discordance between catheter-directed ct hepatic angiography versus tc-99m-maa spect/ct as a possible first human demonstration of in-vivo microparticle trajectory selection for specific daughter vessel targeting
-
(Supplement 1)
-
Kao, Y. H., Tan, A. E. H., Ng, D. C. E., and Goh, A. S. W., 2011, Controversy in Yttrium-90 Selective Internal Radiation Therapy: Imaging Discordance between Catheter-Directed CT Hepatic Angiography Versus Tc-99m-MAA SPECT/CT as a Possible First Human Demonstration of In-Vivo Microparticle Trajectory Selection for Specific Daughter Vessel Targeting., J. Nucl. Med., 52 (Supplement 1), p. 1083.
-
(2011)
J. Nucl. Med.
, vol.52
, pp. 1083
-
-
Kao, Y.H.1
Tan, A.E.H.2
Ng, D.C.E.3
Goh, A.S.W.4
-
9
-
-
16644371375
-
Does variant hepatic artery anatomy in a liver transplant recipient increase the risk of hepatic artery complications after transplantation?
-
Ishigami, K., Zhang, Y., Rayhill, S., Katz, D., and Stolpen, A., 2004, Does Variant Hepatic Artery Anatomy in a Liver Transplant Recipient Increase the Risk of Hepatic Artery Complications after Transplantation, Am. J. Roentgenol., 183, pp. 1577-1584. (Pubitemid 44210523)
-
(2004)
American Journal of Roentgenology
, vol.183
, Issue.6
, pp. 1577-1584
-
-
Ishigami, K.1
Zhang, Y.2
Rayhill, S.3
Katz, D.4
Stolpen, A.5
-
10
-
-
0026543649
-
Estimation of total hepatic flow by duplex ultrasound
-
Carlisle, K. M., Halliwell, M., Read, A. E., and Wells, P. N., 1992, Estimation of Total Hepatic Flow by Duplex Ultrasound., Gut, 33, pp. 92-97.
-
(1992)
Gut
, vol.33
, pp. 92-97
-
-
Carlisle, K.M.1
Halliwell, M.2
Read, A.E.3
Wells, P.N.4
-
11
-
-
0036224363
-
Duplex Doppler ultrasound of the hepatic artery in patients with acute alcoholic hepatitis
-
DOI 10.1097/00004836-200205000-00019
-
Han, S. H. B., Rice, S., Cohen, S. M., Reynolds, T. B., and Fong, T. L., 2002, Duplex Doppler Ultrasound of the Hepatic Artery in Patients With Acute Alcoholic Hepatitis., J. Clin. Gastroenterol., 34 (5), pp. 573-577. (Pubitemid 34429421)
-
(2002)
Journal of Clinical Gastroenterology
, vol.34
, Issue.5
, pp. 573-577
-
-
Han, S.-H.B.1
Rice, S.2
Cohen, S.M.3
Reynolds, T.B.4
Fong, T.-L.5
-
12
-
-
65249138253
-
Respiratory self-gaiting for free-breathing abdominal phase-contrast blood flow measurements
-
Jin, N., Lewandowski, R. J., Omary, R. A., and Larson, A. C., 2009, Respiratory Self-Gaiting for Free-Breathing Abdominal Phase-Contrast Blood Flow Measurements., J. Magn. Reson. Imaging, 29, pp. 860-868.
-
(2009)
J. Magn. Reson. Imaging
, vol.29
, pp. 860-868
-
-
Jin, N.1
Lewandowski, R.J.2
Omary, R.A.3
Larson, A.C.4
-
13
-
-
28044465731
-
Yttrium-90 microsphere therapy for hepatic malignancy: Devices, indications, technical considerations, and potential complications
-
Murthy, R., Nunez, R., Szklaruk, J., Erwin, W., Madoff, D. C., Gupta, S., Ahar, K., Wallace, M. J., Cohen, A., Coldwell, D. M., Kennedy, A. S., and Hicks, M. E., 2005, Yttrium-90 Microsphere Therapy for Hepatic Malignancy: Devices, Indications, Technical Considerations, and Potential Complications., RadioGraphics, 25, pp. S41-S55.
-
(2005)
RadioGraphics
, vol.25
-
-
Murthy, R.1
Nunez, R.2
Szklaruk, J.3
Erwin, W.4
Madoff, D.C.5
Gupta, S.6
Ahar, K.7
Wallace, M.J.8
Cohen, A.9
Coldwell, D.M.10
Kennedy, A.S.11
Hicks, M.E.12
-
14
-
-
0034023446
-
Rheological effects on pulsatile hemodynamics in a stenosed tube
-
DOI 10.1016/S0045-7930(99)00019-5, PII S0045793099000195
-
Buchanan, J. R., Kleinstreuer, C., and Comer, J. K., 2000, Rheological Effects onPulsatile Hemodynamics in a Stenosed Tube., Comput. Fluids, 29, pp. 695-724. (Pubitemid 30306543)
-
(2000)
Computers and Fluids
, vol.29
, Issue.6
, pp. 695-724
-
-
Buchanan Jr., J.R.1
Kleinstreuer, C.2
Comer, J.K.3
-
15
-
-
0014594765
-
Rheology of blood
-
Merrill, E. W., 1969, Rheology of Blood., Physiol. Rev., 49 (4), pp. 863-888.
-
(1969)
Physiol. Rev.
, vol.49
, Issue.4
, pp. 863-888
-
-
Merrill, E.W.1
-
16
-
-
2442588688
-
Particle-hemodynamics simulations and design options for surgical reconstruction of diseased carotid artery bifurcations
-
DOI 10.1115/1.1688777
-
Hyun, S., Kleinstreuer, C., Longest, P. W., and Chen, C., 2004, Particle-Hemodynamics Simulations and Design Options for Surgical Reconstruction of Diseased Carotid Artery Bifurcations., ASME J. Biomech. Eng., 126 (2), pp. 188-195. (Pubitemid 38621131)
-
(2004)
Journal of Biomechanical Engineering
, vol.126
, Issue.2
, pp. 188-195
-
-
Hyun, S.1
Kleinstreuer, C.2
Longest, P.W.3
Chen, C.4
-
17
-
-
0242286607
-
Efficient computation of micro-particle dynamics including wall effects
-
DOI 10.1016/j.compfluid.2003.06.002
-
Longest, P. W., Kleinstreuer, C., and Buchanan, J. R., 2004, Efficient Computation of Micro-Particle Dynamics including Wall Effects., Comput. Fluids, 33, pp. 577-601. (Pubitemid 37358727)
-
(2004)
Computers and Fluids
, vol.33
, Issue.4
, pp. 577-601
-
-
Longest, P.W.1
Kleinstreuer, C.2
Buchanan, J.R.3
-
18
-
-
79958784662
-
-
Ph.D. dissertation, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC
-
Basciano, C. A., 2010, Computational Particle-Hemodynamics Analysis Applied to an Abdominal Aortic Aneurysm With Thrombus and Microsphere-Targeting of Liver Tumors., Ph.D. dissertation, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC.
-
(2010)
Computational Particle-Hemodynamics Analysis Applied to An Abdominal Aortic Aneurysm with Thrombus and Microsphere-Targeting of Liver Tumors
-
-
Basciano, C.A.1
-
19
-
-
84555202651
-
Experimental microsphere targeting in a representative hepatic artery system
-
Richards, A. L., Kleinstreuer, C., Kennedy, A. S., Childress, E., and Buckner, G. D., 2012, Experimental Microsphere Targeting in a Representative Hepatic Artery System., IEEE Trans. Biomed. Eng., 59, pp. 198-204.
-
(2012)
IEEE Trans. Biomed. Eng.
, vol.59
, pp. 198-204
-
-
Richards, A.L.1
Kleinstreuer, C.2
Kennedy, A.S.3
Childress, E.4
Buckner, G.D.5
|