메뉴 건너뛰기




Volumn 29, Issue 4, 2009, Pages 860-868

Respiratory self-gating for free-breathing abdominal phase-contrast blood flow measurements

Author keywords

Abdomen; Flow; Phase contrast; Respiratory self gating

Indexed keywords

ARTICLE; ARTIFACT; BLOOD FLOWMETRY; BLOOD VESSEL DIAMETER; BLOOD VOLUME; BREATH HOLDING; BREATHING; BREATHING MECHANICS; FEASIBILITY STUDY; HEPATIC ARTERY; HUMAN; IMAGE ANALYSIS; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PORTAL VEIN; PRIORITY JOURNAL; QUALITATIVE RESEARCH; RENAL ARTERY;

EID: 65249138253     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21711     Document Type: Article
Times cited : (22)

References (27)
  • 1
    • 0024551349 scopus 로고
    • Human abdominal aorta: Comparative measurements of blood flow with MR imaging and multigated Doppler US
    • Maier SE, Meier D, Boesiger P, Moser UT, Vieli A. Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US. Radiology 1989;171:487-492.
    • (1989) Radiology , vol.171 , pp. 487-492
    • Maier, S.E.1    Meier, D.2    Boesiger, P.3    Moser, U.T.4    Vieli, A.5
  • 2
    • 0023679091 scopus 로고
    • Quantitative flow measurements on phantoms and on blood vessels with MR
    • Meier D, Maier S, Bosiger P. Quantitative flow measurements on phantoms and on blood vessels with MR. Magn Reson Med 1988; 8:25-34.
    • (1988) Magn Reson Med , vol.8 , pp. 25-34
    • Meier, D.1    Maier, S.2    Bosiger, P.3
  • 3
    • 0023113452 scopus 로고
    • Quantitative phase- flow MR imaging in dogs by using standard sequences: Comparison with in vivo flow-meter measurements
    • Pettigrew RI, Dannels W, Galloway JR, et al. Quantitative phase- flow MR imaging in dogs by using standard sequences: comparison with in vivo flow-meter measurements. AJR Am J Roentgenol 1987; 148:411-414.
    • (1987) AJR Am J Roentgenol , vol.148 , pp. 411-414
    • Pettigrew, R.I.1    Dannels, W.2    Galloway, J.R.3
  • 4
    • 0021972302 scopus 로고
    • Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method
    • Moran PR, Moran RA, Karstaedt N. Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method. Radiology 1985;154:433-441.
    • (1985) Radiology , vol.154 , pp. 433-441
    • Moran, P.R.1    Moran, R.A.2    Karstaedt, N.3
  • 6
    • 14044270785 scopus 로고    scopus 로고
    • Comparison of the hepatic perfusion index measured with gadolinium-enhanced volumetric MRI in controls and in patients with colorectal cancer
    • Totman JJ, O'Gorman R L, Kane PA, Karani JB. Comparison of the hepatic perfusion index measured with gadolinium-enhanced volumetric MRI in controls and in patients with colorectal cancer. Br J Radiol 2005;78:105-109.
    • (2005) Br J Radiol , vol.78 , pp. 105-109
    • Totman, J.J.1    O'Gorman, R.L.2    Kane, P.A.3    Karani, J.B.4
  • 7
    • 0027487475 scopus 로고
    • Early detection of occult colorectal hepatic metastases using duplex colour Doppler sonography
    • Leen E, Goldberg JA, Robertson J, et al. Early detection of occult colorectal hepatic metastases using duplex colour Doppler sonography. Br J Surg 1993;80:1249-1251.
    • (1993) Br J Surg , vol.80 , pp. 1249-1251
    • Leen, E.1    Goldberg, J.A.2    Robertson, J.3
  • 8
    • 0028144633 scopus 로고
    • Renal artery blood flow: Quantitation with phase-contrast MR imaging with and without breath holding
    • Debatin JF, Ting RH, Wegmuller H, et al. Renal artery blood flow: quantitation with phase-contrast MR imaging with and without breath holding. Radiology 1994;190:371-378.
    • (1994) Radiology , vol.190 , pp. 371-378
    • Debatin, J.F.1    Ting, R.H.2    Wegmuller, H.3
  • 9
    • 0027564412 scopus 로고
    • Accuracy of phase-contrast flow measurements in the presence of partial-volume effects
    • Tang C, Blatter DD, Parker DL. Accuracy of phase-contrast flow measurements in the presence of partial-volume effects. J Magn Reson Imaging 1993;3:377-385.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 377-385
    • Tang, C.1    Blatter, D.D.2    Parker, D.L.3
  • 10
    • 44949196855 scopus 로고    scopus 로고
    • Respiratory self-gated four-dimensional coronary MR angiography: A feasibility study
    • Lai P, Larson AC, Park J, Carr JC, Li D. Respiratory self-gated four-dimensional coronary MR angiography: a feasibility study. Magn Reson Med 2008;59:1378-1385.
    • (2008) Magn Reson Med , vol.59 , pp. 1378-1385
    • Lai, P.1    Larson, A.C.2    Park, J.3    Carr, J.C.4    Li, D.5
  • 11
    • 12144262426 scopus 로고    scopus 로고
    • Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI
    • Larson AC, Kellman P, Arai A, et al. Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI. Magn Reson Med 2005;53:159-168.
    • (2005) Magn Reson Med , vol.53 , pp. 159-168
    • Larson, A.C.1    Kellman, P.2    Arai, A.3
  • 12
    • 32544435924 scopus 로고    scopus 로고
    • Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging
    • Brau AC, Brittain JH. Generalized self-navigated motion detection technique: preliminary investigation in abdominal imaging. Magn Reson Med 2006;55:263-270.
    • (2006) Magn Reson Med , vol.55 , pp. 263-270
    • Brau, A.C.1    Brittain, J.H.2
  • 16
    • 30344456972 scopus 로고    scopus 로고
    • PC VIPR: A high-speed 3D phase-contrast method for flow quantification and high-resolution angiography
    • Gu T, Korosec FR, Block WF, et al. PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography. AJNR Am J Neuroradiol 2005;26:743-749.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 743-749
    • Gu, T.1    Korosec, F.R.2    Block, W.F.3
  • 17
    • 65249102505 scopus 로고    scopus 로고
    • Velikina J, Johnson K, Wu Y, Turski P, Mistretta C. PC HYPR flow: a technique for rapid imaging of contrast dynamics. In: Proc ISMRM, Toronto, 2008. p 465.
    • Velikina J, Johnson K, Wu Y, Turski P, Mistretta C. PC HYPR flow: a technique for rapid imaging of contrast dynamics. In: Proc ISMRM, Toronto, 2008. p 465.
  • 18
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL. Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 1996;198:55-60.
    • (1996) Radiology , vol.198 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 19
    • 34047115315 scopus 로고    scopus 로고
    • Time-resolved 3D MR velocity mapping at 3T: Improved navigator-gated assessment of vascular anatomy and blood flow
    • Markl M, Harloff A, Bley TA, et al. Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging 2007;25:824-831.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 824-831
    • Markl, M.1    Harloff, A.2    Bley, T.A.3
  • 20
    • 0027258288 scopus 로고
    • Volumetric flow rates in the portal venous system: Measurement with cine phase-contrast MR imaging
    • Burkart DJ, Johnson CD, Morton MJ, Wolf RL, Ehman RL. Volumetric flow rates in the portal venous system: measurement with cine phase-contrast MR imaging. AJR Am J Roentgenol 1993;160: 1113-1118.
    • (1993) AJR Am J Roentgenol , vol.160 , pp. 1113-1118
    • Burkart, D.J.1    Johnson, C.D.2    Morton, M.J.3    Wolf, R.L.4    Ehman, R.L.5
  • 21
    • 0035084261 scopus 로고    scopus 로고
    • Coronary arteries: Magnetization- prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography
    • Li D, Carr JC, Shea SM, et al. Coronary arteries: magnetization- prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography. Radiology 2001;219:270-277.
    • (2001) Radiology , vol.219 , pp. 270-277
    • Li, D.1    Carr, J.C.2    Shea, S.M.3
  • 22
    • 0025135213 scopus 로고
    • Estimation of hepatic blood flow in branches of hepatic vessels utilizing a noninvasive, duplex Doppler method
    • Horn JR, Zierler B, Bauer LA, Reiss W, Strandness DE Jr. Estimation of hepatic blood flow in branches of hepatic vessels utilizing a noninvasive, duplex Doppler method. J Clin Pharmacol 1990;30: 922-929.
    • (1990) J Clin Pharmacol , vol.30 , pp. 922-929
    • Horn, J.R.1    Zierler, B.2    Bauer, L.A.3    Reiss, W.4    Strandness Jr., D.E.5
  • 23
    • 0032758126 scopus 로고    scopus 로고
    • Portal venous blood flow while breath-holding after inspiration or expiration and during normal respiration in controls and cirrhotics
    • Sugano S, Yamamoto K, Sasao K, Watanabe M. Portal venous blood flow while breath-holding after inspiration or expiration and during normal respiration in controls and cirrhotics. J Gastroenterol 1999;34:613-618.
    • (1999) J Gastroenterol , vol.34 , pp. 613-618
    • Sugano, S.1    Yamamoto, K.2    Sasao, K.3    Watanabe, M.4
  • 24
    • 0031828994 scopus 로고    scopus 로고
    • MR quantification of flow in abdominal vessels
    • Debatin JF. MR quantification of flow in abdominal vessels. Abdom Imaging 1998;23:485-495.
    • (1998) Abdom Imaging , vol.23 , pp. 485-495
    • Debatin, J.F.1
  • 25
    • 0035195107 scopus 로고    scopus 로고
    • A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    • discussion 295-286
    • Du YP, McVeigh ER, Bluemke DA, Silber HA, Foo TK. A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography. Int J Cardiovasc Imaging 2001;17:287- 294; discussion 295-286.
    • (2001) Int J Cardiovasc Imaging , vol.17 , pp. 287-294
    • Du, Y.P.1    McVeigh, E.R.2    Bluemke, D.A.3    Silber, H.A.4    Foo, T.K.5
  • 26
    • 12244274310 scopus 로고    scopus 로고
    • Time-resolved three-dimensional phase-contrast MRI
    • Markl M, Chan FP, Alley MT, et al. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 2003;17:499- 506.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 499-506
    • Markl, M.1    Chan, F.P.2    Alley, M.T.3
  • 27
    • 33845239018 scopus 로고    scopus 로고
    • Cardiorespiratory-resolved magnetic resonance imaging: Measuring respiratory modulation of cardiac function
    • Thompson RB, McVeigh ER. Cardiorespiratory-resolved magnetic resonance imaging: measuring respiratory modulation of cardiac function. Magn Reson Med 2006;56:1301-1310.
    • (2006) Magn Reson Med , vol.56 , pp. 1301-1310
    • Thompson, R.B.1    McVeigh, E.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.