메뉴 건너뛰기




Volumn 26, Issue 6, 2011, Pages 1324-1332

A 5-Year prospective multicenter study of early loaded titanium implants with a sandblasted and acid-etched surface

Author keywords

Clinical trial; Dental implants; Early loading; Implant supported prostheses; Multicenter study

Indexed keywords

TITANIUM;

EID: 84863192532     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (80)

References (52)
  • 1
    • 0014636440 scopus 로고
    • Intra-osseous anchorage of dental prostheses. I. Experimental studies
    • Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969;3: 81-100.
    • (1969) Scand J Plast Reconstr Surg , vol.3 , pp. 81-100
    • Ohlsson, A.1
  • 2
    • 0019414459 scopus 로고
    • The reaction of bone, connective tissue and epithelium to endosteal implants with titanium-sprayed surfaces
    • Schroeder A, van der Zypen E, Stich H, Sutter F. The reaction of bone, connective tissue and epithelium to endosteal implants with titanium-sprayed surfaces. J Maxillofac Surg 1981;9: 15-25.
    • (1981) J Maxillofac Surg , vol.9 , pp. 15-25
    • Schroeder, A.1    van der Zypen, E.2    Stich, H.3    Sutter, F.4
  • 3
    • 0016980179 scopus 로고
    • Gewebsreaktion auf ein Titan-Hohlzylinderimplantat mit Titan-Spritzschichtoberfläche [in German]
    • Schroeder A, Pohler O, Sutter F. Gewebsreaktion auf ein Titan-Hohlzylinderimplantat mit Titan-Spritzschichtoberfläche [in German]. Schweiz Monatsschr Zahnheilkd 1976;86: 713-727.
    • (1976) Schweiz Monatsschr Zahnheilkd , vol.86 , pp. 713-727
    • Schroeder, A.1    Pohler, O.2    Sutter, F.3
  • 4
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a ten-year period
    • Bränemark P-I, Hannsson BO, Adell R. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a ten-year period. Scand J Plast Reconstr Surg 1977;16(suppl): 1-132.
    • (1977) Scand J Plast Reconstr Surg , vol.16 , pp. 1-132
    • Bränemark, P.-I.1    Hannsson, B.O.2    Adell, R.3
  • 5
    • 12244283740 scopus 로고    scopus 로고
    • Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants
    • Cochran DL, Morton D, Weber HP. Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants. Int J Oral Maxillofac Implants 2004; 19(suppl): 109-113.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 109-113
    • Cochran, D.L.1    Morton, D.2    Weber, H.P.3
  • 6
    • 44349157607 scopus 로고    scopus 로고
    • Clinical outcomes of immediate/early loading of dental implants. A literature review of recent controlled prospective clinical studies
    • Sennerby L, Gottlow J. Clinical outcomes of immediate/early loading of dental implants. A literature review of recent controlled prospective clinical studies. Aust Dent J 2008;53(suppl 1): S82-S88.
    • (2008) Aust Dent J , vol.53 , pp. S82-S88
    • Sennerby, L.1    Gottlow, J.2
  • 7
    • 0036547410 scopus 로고    scopus 로고
    • The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants
    • Cochran DL, Buser D, ten Bruggenkate CM, et al. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants. Clin Oral Implants Res 2002;12: 144-153.
    • (2002) Clin Oral Implants Res , vol.12 , pp. 144-153
    • Cochran, D.L.1    Buser, D.2    ten Bruggenkate, C.M.3
  • 8
    • 50849085742 scopus 로고    scopus 로고
    • A retrospective analysis of sandblasted, acid-etched implants with reduced healing times with an observation period of up to 5 years
    • Nelson K, Semper W, Hildebrand D, Özyuvaci H. A retrospective analysis of sandblasted, acid-etched implants with reduced healing times with an observation period of up to 5 years. Int J Oral Maxillofac Implants 2008;23: 726-732.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 726-732
    • Nelson, K.1    Semper, W.2    Hildebrand, D.3    Özyuvaci, H.4
  • 9
    • 77953274080 scopus 로고    scopus 로고
    • Early loading at 21 days of non-submerged titanium implants with a chemically modified sandblasted and acid-etched surface: 3-year results of a prospective study in the posterior mandible
    • Bornstein MM, Wittneben J-G, Brägger U, Buser D. Early loading at 21 days of non-submerged titanium implants with a chemically modified sandblasted and acid-etched surface: 3-year results of a prospective study in the posterior mandible. J Periodontol 2010; 81: 809-818.
    • (2010) J Periodontol , vol.81 , pp. 809-818
    • Bornstein, M.M.1    Wittneben, J.-G.2    Brägger, U.3    Buser, D.4
  • 10
    • 76549114139 scopus 로고    scopus 로고
    • Early loading after 21 days of healing of nonsubmerged titanium implants with a chemically modified sandblasted and acid-etched surface: Two-year results of a prospective two-center study
    • Morton D, Bornstein MM, Wittneben J-G, et al. Early loading after 21 days of healing of nonsubmerged titanium implants with a chemically modified sandblasted and acid-etched surface: Two-year results of a prospective two-center study. Clin Implant Dent Relat Res 2010;12: 9-17.
    • (2010) Clin Implant Dent Relat Res , vol.12 , pp. 9-17
    • Morton, D.1    Bornstein, M.M.2    Wittneben, J.-G.3
  • 11
    • 0033252636 scopus 로고    scopus 로고
    • A comparison of endosseous dental implant surfaces: State of the art review
    • Cochran DL. A comparison of endosseous dental implant surfaces: State of the art review. J Periodontol 1999;70: 1523-1539.
    • (1999) J Periodontol , vol.70 , pp. 1523-1539
    • Cochran, D.L.1
  • 12
    • 0023302919 scopus 로고
    • Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants
    • Johansson C, Albrektsson T. Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987;2: 69-75.
    • (1987) Int J Oral Maxillofac Implants , vol.2 , pp. 69-75
    • Johansson, C.1    Albrektsson, T.2
  • 13
    • 0026300431 scopus 로고
    • Histomorphometric studies of hydroxylapatite- coated and uncoated CP titanium threaded implants in bone
    • Gottlander M, Albrektsson T. Histomorphometric studies of hydroxylapatite- coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants 1991;6: 399-404.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 399-404
    • Gottlander, M.1    Albrektsson, T.2
  • 14
    • 0026301882 scopus 로고
    • A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and Vitallium implants
    • Johansson CB, Sennerby L, Albrektsson T. A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and Vitallium implants. Int J Oral Maxillofac Implants 1991;6: 437-441.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 437-441
    • Johansson, C.B.1    Sennerby, L.2    Albrektsson, T.3
  • 15
    • 0027024580 scopus 로고
    • A histomorphometric study of unthreaded hydroxyapatite-coated and titanium-coated implants in rabbit bone
    • Gottlander M, Albrektsson T, Carlsson LV. A histomorphometric study of unthreaded hydroxyapatite-coated and titanium-coated implants in rabbit bone. Int J Oral Maxillofac Implants 1992;7: 485-490.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 485-490
    • Gottlander, M.1    Albrektsson, T.2    Carlsson, L.V.3
  • 16
    • 0032053958 scopus 로고    scopus 로고
    • Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible
    • Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J Biomed Mater Res 1998;40: 1-11.
    • (1998) J Biomed Mater Res , vol.40 , pp. 1-11
    • Cochran, D.L.1    Schenk, R.K.2    Lussi, A.3    Higginbottom, F.L.4    Buser, D.5
  • 17
    • 0031067775 scopus 로고    scopus 로고
    • Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible
    • Cochran DL, Hermann JS, Schenk RK, Higginbottom FL, Buser D. Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible. J Periodontol 1997;68: 186-198.
    • (1997) J Periodontol , vol.68 , pp. 186-198
    • Cochran, D.L.1    Hermann, J.S.2    Schenk, R.K.3    Higginbottom, F.L.4    Buser, D.5
  • 18
    • 0041922478 scopus 로고    scopus 로고
    • Bone-implant contact on machined and dual acid-etched surfaces after 2 months of healing in the human maxilla
    • Trisi P, Lazzara R, Rebaudi A, Rao W, Testori T, Porter SS. Bone-implant contact on machined and dual acid-etched surfaces after 2 months of healing in the human maxilla. J Periodontol 2003;74: 945-956.
    • (2003) J Periodontol , vol.74 , pp. 945-956
    • Trisi, P.1    Lazzara, R.2    Rebaudi, A.3    Rao, W.4    Testori, T.5    Porter, S.S.6
  • 19
    • 0023583441 scopus 로고
    • The microbiota associated with successful or failing osseointegrated titanium implants
    • Mombelli A, van Oosten MA, Schurch E Jr, Lang NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 1987;2: 145-151.
    • (1987) Oral Microbiol Immunol , vol.2 , pp. 145-151
    • Mombelli, A.1    van Oosten, M.A.2    Schurch Jr, E.3    Lang, N.P.4
  • 20
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implant. Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implant. Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997;8: 161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 21
    • 0033140229 scopus 로고    scopus 로고
    • Clinical experience with one-stage, non-submerged dental implants
    • Buser D, Mericske-Stern R, Dula K, Lang NP. Clinical experience with one-stage, non-submerged dental implants. Adv Dent Res 1999;13: 153-161.
    • (1999) Adv Dent Res , vol.13 , pp. 153-161
    • Buser, D.1    Mericske-Stern, R.2    Dula, K.3    Lang, N.P.4
  • 22
    • 0030224083 scopus 로고    scopus 로고
    • Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: Radiographic results
    • Cochran DL, Nummikoski PV, Higginbottom FL, Hermann JS, Makins SR, Buser D. Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: Radiographic results. Clin Oral Implants Res 1996;7: 240-252.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 240-252
    • Cochran, D.L.1    Nummikoski, P.V.2    Higginbottom, F.L.3    Hermann, J.S.4    Makins, S.R.5    Buser, D.6
  • 23
    • 0029256715 scopus 로고
    • Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63)
    • Martin JY, Schwartz Z, Hummert TW, et al. Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63). J Biomed Mater Res 1995;29: 389-401.
    • (1995) J Biomed Mater Res , vol.29 , pp. 389-401
    • Martin, J.Y.1    Schwartz, Z.2    Hummert, T.W.3
  • 25
    • 0033135482 scopus 로고    scopus 로고
    • Interface shear strength of titanium implants with a sandblasted and acid-etched surface: A biomechanical study in the maxilla of miniature pigs
    • Buser D, Nydegger T, Oxlant T, et al. Interface shear strength of titanium implants with a sandblasted and acid-etched surface: A biomechanical study in the maxilla of miniature pigs. J Biomed Mater Res 1999;45: 75-83.
    • (1999) J Biomed Mater Res , vol.45 , pp. 75-83
    • Buser, D.1    Nydegger, T.2    Oxlant, T.3
  • 27
    • 0036185427 scopus 로고    scopus 로고
    • Biomechanical comparison of the sandblasted and acid-etched and the machined and acidetched titanium surface for dental implants
    • Li D, Ferguson SJ, Beutler T, et al. Biomechanical comparison of the sandblasted and acid-etched and the machined and acidetched titanium surface for dental implants. J Biomed Mater Res 2002;60: 325-332.
    • (2002) J Biomed Mater Res , vol.60 , pp. 325-332
    • Li, D.1    Ferguson, S.J.2    Beutler, T.3
  • 28
    • 0036782259 scopus 로고    scopus 로고
    • Bone response to alteration of surface topography and surface composition of sandblasted and acid etched (SLA) implants
    • Perrin D, Szmukler-Moncler S, Echikou C, Pointaire P, Bernard JP. Bone response to alteration of surface topography and surface composition of sandblasted and acid etched (SLA) implants. Clin Oral Implants Res 2002;13: 465-469.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 465-469
    • Perrin, D.1    Szmukler-Moncler, S.2    Echikou, C.3    Pointaire, P.4    Bernard, J.P.5
  • 30
    • 0142088696 scopus 로고    scopus 로고
    • Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    • Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2003;18: 641-651.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 641-651
    • Barewal, R.M.1    Oates, T.W.2    Meredith, N.3    Cochran, D.L.4
  • 31
    • 34247554173 scopus 로고    scopus 로고
    • Histologic evaluation of human bone integration on machined and sandblasted acid-etched titanium surfaces in type IV bone
    • Grassi S, Piattelli A, Ferrari DS, et al. Histologic evaluation of human bone integration on machined and sandblasted acid-etched titanium surfaces in type IV bone. J Oral Implantol 2007;33: 8-12.
    • (2007) J Oral Implantol , vol.33 , pp. 8-12
    • Grassi, S.1    Piattelli, A.2    Ferrari, D.S.3
  • 33
    • 0035650821 scopus 로고    scopus 로고
    • Early loading of sandblasted and acid-etched (SLA) implants: A prospective split-mouth comparative study
    • Roccuzzo M, Bunino M, Prioglio F, Bianchi SD. Early loading of sandblasted and acid-etched (SLA) implants: A prospective split-mouth comparative study. Clin Oral Implants Res 2001;12: 572-578.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 572-578
    • Roccuzzo, M.1    Bunino, M.2    Prioglio, F.3    Bianchi, S.D.4
  • 34
    • 0036780887 scopus 로고    scopus 로고
    • A prospective study evaluating a protocol for 6 weeks’ loading of SLA implants in the posterior maxilla: One-year results
    • Roccuzzo M, Wilson T. A prospective study evaluating a protocol for 6 weeks’ loading of SLA implants in the posterior maxilla: One-year results. Clin Oral Implants Res 2002;13: 502-507.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 502-507
    • Roccuzzo, M.1    Wilson, T.2
  • 35
    • 0036977870 scopus 로고    scopus 로고
    • Conventional and early loading of unsplinted ITI implants supporting mandibular overdentures
    • Payne AG, Tawse-Smith A, Duncan WD, Kumara R. Conventional and early loading of unsplinted ITI implants supporting mandibular overdentures. Clin Oral Implants Res 2002;13: 603-609.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 603-609
    • Payne, A.G.1    Tawse-Smith, A.2    Duncan, W.D.3    Kumara, R.4
  • 37
    • 0142088695 scopus 로고    scopus 로고
    • Early loading of nonsubmerged titanium implants with a sandblasted and acidetched (SLA) surface: 3-year results of a prospective study in partially edentulous patients
    • Bornstein MM, Lussi A, Schmid B, Belser UC, Buser D. Early loading of nonsubmerged titanium implants with a sandblasted and acidetched (SLA) surface: 3-year results of a prospective study in partially edentulous patients. Int J Oral Maxillofac Implants 2003;18: 659-666.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 659-666
    • Bornstein, M.M.1    Lussi, A.2    Schmid, B.3    Belser, U.C.4    Buser, D.5
  • 38
    • 2942657499 scopus 로고    scopus 로고
    • Early loading (2 or 6 weeks) of sandblasted and acid-etched (SLA) ITI implants in the posterior mandibl. A 1-year randomized controlled clinical trial
    • Salvi GE, Gallini G, Lang NP. Early loading (2 or 6 weeks) of sandblasted and acid-etched (SLA) ITI implants in the posterior mandibl. A 1-year randomized controlled clinical trial. Clin Oral Implants Res 2004;15: 142-149.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 142-149
    • Salvi, G.E.1    Gallini, G.2    Lang, N.P.3
  • 39
    • 2342439421 scopus 로고    scopus 로고
    • Radiologic follow-up of periimplant bone loss around machine-surfaced and rough-surfaced interforaminal implants in the mandible functionally loaded for 3 to 7 years
    • Zechner W, Trinkl N, Watzek G, et al. Radiologic follow-up of periimplant bone loss around machine-surfaced and rough-surfaced interforaminal implants in the mandible functionally loaded for 3 to 7 years. Int J Oral Maxillofac Implants 2004;19: 216-221.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 216-221
    • Zechner, W.1    Trinkl, N.2    Watzek, G.3
  • 40
    • 11444265467 scopus 로고    scopus 로고
    • A 3-arm study of early loading of rough-surfaced implants in the completely edentulous maxilla and in the edentulous posterior maxilla and mandible: Results after 1 year of loading
    • Nordin T, Nilsson R, Frykholm A, Hallman M. A 3-arm study of early loading of rough-surfaced implants in the completely edentulous maxilla and in the edentulous posterior maxilla and mandible: Results after 1 year of loading. Int J Oral Maxillofac Implants 2004;19: 880-886.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 880-886
    • Nordin, T.1    Nilsson, R.2    Frykholm, A.3    Hallman, M.4
  • 41
    • 14844341586 scopus 로고    scopus 로고
    • Early loading of sandblasted, acid-etched implants in the posterior maxilla and mandible: A 1-year follow-up report from a multicenter 3-year prospective study
    • Luongo G, Di Raimondo R, Filippini P, Gualini F, Paoleschi C. Early loading of sandblasted, acid-etched implants in the posterior maxilla and mandible: A 1-year follow-up report from a multicenter 3-year prospective study. Int J Oral Maxillofac Implants 2005;20: 84-91.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 84-91
    • Luongo, G.1    Di Raimondo, R.2    Filippini, P.3    Gualini, F.4    Paoleschi, C.5
  • 42
    • 33644673024 scopus 로고    scopus 로고
    • Early loading of non-submerged titanium implants with a sandblasted and acidetched surface. 5-year results of a prospective study in partially edentulous patients
    • Bornstein MM, Schmid B, Belser UC, Lussi A, Buser D. Early loading of non-submerged titanium implants with a sandblasted and acidetched surface. 5-year results of a prospective study in partially edentulous patients. Clin Oral Implants Res 2005;16: 631-638.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 631-638
    • Bornstein, M.M.1    Schmid, B.2    Belser, U.C.3    Lussi, A.4    Buser, D.5
  • 43
    • 34547361066 scopus 로고    scopus 로고
    • Early functional loading of sand-blasted and acid-etched (SLA) Straumann implants following immediate placement in maxillary extraction sockets. Clinical and radiographic result
    • Nordin T, Graf J, Frykholm A, Helldén L. Early functional loading of sand-blasted and acid-etched (SLA) Straumann implants following immediate placement in maxillary extraction sockets. Clinical and radiographic result. Clin Oral Implants Res 2007;18: 441-451.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 441-451
    • Nordin, T.1    Graf, J.2    Frykholm, A.3    Helldén, L.4
  • 44
    • 34548583008 scopus 로고    scopus 로고
    • Clinical performance of wide-body implants with a sandblasted and acid-etched (SLA) surface: Results of a 3-year follow-up study in a referral clinic
    • Bornstein MM, Harnisch H, Lussi A, Buser D. Clinical performance of wide-body implants with a sandblasted and acid-etched (SLA) surface: Results of a 3-year follow-up study in a referral clinic. Int J Oral Maxillofac Implants 2007;22: 631-638.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 631-638
    • Bornstein, M.M.1    Harnisch, H.2    Lussi, A.3    Buser, D.4
  • 45
    • 36049049424 scopus 로고    scopus 로고
    • Roles of bone scintigraphy and resonance frequency analysis in evaluating osseointegration of endosseous implant
    • Zhou Y, Jiang T, Qian M, et al. Roles of bone scintigraphy and resonance frequency analysis in evaluating osseointegration of endosseous implant. Biomaterials 2008;29: 461-474.
    • (2008) Biomaterials , vol.29 , pp. 461-474
    • Zhou, Y.1    Jiang, T.2    Qian, M.3
  • 46
    • 37849006816 scopus 로고    scopus 로고
    • Early loading of sandblasted and acid-etched implants: A randomized-controlled double-blind split-mouth study. Five-year results
    • Roccuzzo M, Aglietta M, Bunino M, Bonino L. Early loading of sandblasted and acid-etched implants: A randomized-controlled double-blind split-mouth study. Five-year results. Clin Oral Implants Res 2008;19: 148-152.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 148-152
    • Roccuzzo, M.1    Aglietta, M.2    Bunino, M.3    Bonino, L.4
  • 48
    • 78049450800 scopus 로고    scopus 로고
    • A 5-year report from a multicentre randomized clinical trial: Immediate non-occlusal versus early loading of dental implants in partially edentulous patients
    • Capelli M, Esposito M, Zuffetti F, Galli F, Del Fabbro M, Testori T. A 5-year report from a multicentre randomized clinical trial: Immediate non-occlusal versus early loading of dental implants in partially edentulous patients. Eur J Oral Implantol 2010;3: 209-219.
    • (2010) Eur J Oral Implantol , vol.3 , pp. 209-219
    • Capelli, M.1    Esposito, M.2    Zuffetti, F.3    Galli, F.4    Del Fabbro, M.5    Testori, T.6
  • 49
    • 77953748799 scopus 로고    scopus 로고
    • Marginal bone level changes and prosthetic maintenance of mandibular overdentures supported by 2 implants: A 5-year randomized clinical trial
    • Cehreli MC, Uysal S, Akca K. Marginal bone level changes and prosthetic maintenance of mandibular overdentures supported by 2 implants: A 5-year randomized clinical trial. Clin Implant Dent Relat Res 2010;12: 114-121.
    • (2010) Clin Implant Dent Relat Res , vol.12 , pp. 114-121
    • Cehreli, M.C.1    Uysal, S.2    Akca, K.3
  • 50
    • 77953574254 scopus 로고    scopus 로고
    • Early versus delayed loading of mandibular implant-supported overdentures: 5-year results
    • Turkyilmaz I, Tözüm TF, Tumer C. Early versus delayed loading of mandibular implant-supported overdentures: 5-year results. Clin Implant Dent Relat Res 2010;12(suppl 1): e39-e46.
    • (2010) Clin Implant Dent Relat Res , vol.12 , pp. e39-e46
    • Turkyilmaz, I.1    Tözüm, T.F.2    Tumer, C.3
  • 51
    • 47249119659 scopus 로고    scopus 로고
    • A 5-year prospective multicenter study on 1-stage smooth-surface Brånemark System implants with early loading in edentulous mandibles
    • Friberg B, Raghoebar GM, Grunert I, Hobkirk JA, Tepper G. A 5-year prospective multicenter study on 1-stage smooth-surface Brånemark System implants with early loading in edentulous mandibles. Int J Oral Maxillofac Implants 2008;23: 481-486.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 481-486
    • Friberg, B.1    Raghoebar, G.M.2    Grunert, I.3    Hobkirk, J.A.4    Tepper, G.5
  • 52
    • 42149193139 scopus 로고    scopus 로고
    • Five-year results from a randomized, controlled trial on early and delayed loading of implants supporting full-arch prosthesis in the edentulous maxilla
    • Fischer K, Stenberg T, Hedin M, Sennerby L. Five-year results from a randomized, controlled trial on early and delayed loading of implants supporting full-arch prosthesis in the edentulous maxilla. Clin Oral Implants Res 2008;19: 433-441.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 433-441
    • Fischer, K.1    Stenberg, T.2    Hedin, M.3    Sennerby, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.