메뉴 건너뛰기




Volumn 26, Issue 6, 2011, Pages 1279-1287

Influence of implant design on the biomechanical environment of immediately placed implants: Computed tomography-based nonlinear three-dimensional finite element analysis

Author keywords

Dental implant design; Finite element analysis; Immediate implant loading; Immediate implant placement

Indexed keywords

ARTICLE; BIOMECHANICS; BONE REGENERATION; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; DENTAL SURGERY; FINITE ELEMENT ANALYSIS; HUMAN; METHODOLOGY; PHYSIOLOGY; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOOTH SOCKET;

EID: 84863191149     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (34)

References (53)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plastic Reconstr Surg 1977;16(suppl):1-132.
    • (1977) Scand J Plastic Reconstr Surg , vol.16 , pp. 1-132
    • Brånemark, P.I.1    Hansson, B.O.2    Adell, R.3
  • 2
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.I.4
  • 3
    • 84988998521 scopus 로고
    • The long-term efficacy of currently used dental implants: A review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3    Eriksson, A.R.4
  • 4
    • 0034172846 scopus 로고    scopus 로고
    • A 5-year prospective study of Astra single tooth implants
    • Palmer RM, Palmer PJ, Smith BJ. A 5-year prospective study of Astra single tooth implants. Clin Oral Implants Res 2000;11:179-182.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 179-182
    • Palmer, R.M.1    Palmer, P.J.2    Smith, B.J.3
  • 5
    • 0037928812 scopus 로고    scopus 로고
    • A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years
    • Berglundh T, Persson L, Klinge B. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. J Clin Periodontol 2002;29(suppl 3):197-212.
    • (2002) J Clin Periodontol , vol.29 , pp. 197-212
    • Berglundh, T.1    Persson, L.2    Klinge, B.3
  • 7
    • 33744969864 scopus 로고    scopus 로고
    • Effect of controlled early implant loading on bone healing and bone mass in guinea pigs, as assessed by micro-CT and histology
    • De Smet E, Jaecques SV, Wevers M, et al. Effect of controlled early implant loading on bone healing and bone mass in guinea pigs, as assessed by micro-CT and histology. Eur J Oral Sci 2006;114:232-242.
    • (2006) Eur J Oral Sci , vol.114 , pp. 232-242
    • De Smet, E.1    Jaecques, S.V.2    Wevers, M.3
  • 8
    • 35348866752 scopus 로고    scopus 로고
    • Effect of intermittent loading and surface roughness on peri-implant bone formation in a bone chamber model
    • Duyck J, Slaets E, Sasaguri K, Vandamme K, Naert I. Effect of intermittent loading and surface roughness on peri-implant bone formation in a bone chamber model. J Clin Periodontol 2007;34:998-1006.
    • (2007) J Clin Periodontol , vol.34 , pp. 998-1006
    • Duyck, J.1    Slaets, E.2    Sasaguri, K.3    Vandamme, K.4    Naert, I.5
  • 9
    • 38549126296 scopus 로고    scopus 로고
    • Effect of implant surface roughness and loading on peri-implant bone formation
    • Vandamme K, Naert I, Vander Sloten J, Puers R, Duyck J. Effect of implant surface roughness and loading on peri-implant bone formation. J Periodontol 2008;79:150-157.
    • (2008) J Periodontol , vol.79 , pp. 150-157
    • Vandamme, K.1    Naert, I.2    Vander Sloten, J.3    Puers, R.4    Duyck, J.5
  • 10
    • 3042577848 scopus 로고    scopus 로고
    • Immediate occlusal loading of osseotite implants in the lower edentulous jaw. A multicenter prospective study
    • Testori T, Meltzer A, Del Fabbro M, et al. Immediate occlusal loading of osseotite implants in the lower edentulous jaw. A multicenter prospective study. Clin Oral Implants Res 2004;15:278-284.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 278-284
    • Testori, T.1    Meltzer, A.2    Del Fabbro, M.3
  • 11
    • 47149110190 scopus 로고    scopus 로고
    • Immediate functional loading of implants in single-tooth replacement:A prospective clinical multicenter study
    • Donati M, La Scala V, Billi M, Di Dino B, Torrisi P, Berglundh T. Immediate functional loading of implants in single-tooth replacement:A prospective clinical multicenter study. Clin Oral Implants Res 2008;19:740-748.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 740-748
    • Donati, M.1    La Scala, V.2    Billi, M.3    Di Dino, B.4    Torrisi, P.5    Berglundh, T.6
  • 12
    • 0026521288 scopus 로고
    • Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs
    • Søballe K, Brockstedt-Rasmussen H, Hansen ES, Bünger C. Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthop Scand 1992;63:128-140.
    • (1992) Acta Orthop Scand , vol.63 , pp. 128-140
    • Søballe, K.1    Brockstedt-Rasmussen, H.2    Hansen, E.S.3    Bünger, C.4
  • 13
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone-dental implant interface
    • Brunski JB. Biomechanical factors affecting the bone-dental implant interface. Clin Mater 1992;10:153-201.
    • (1992) Clin Mater , vol.10 , pp. 153-201
    • Brunski, J.B.1
  • 14
    • 0027683837 scopus 로고
    • Avoid pitfalls of overloading and micromotion of intraosseous implants
    • Brunski JB. Avoid pitfalls of overloading and micromotion of intraosseous implants. Dent Implantol Update 1993;4:77-81.
    • (1993) Dent Implantol Update , vol.4 , pp. 77-81
    • Brunski, J.B.1
  • 15
    • 1842418824 scopus 로고    scopus 로고
    • Numerical simulation of tissue differentiation around loaded titanium implants in a bone chamber
    • Geris L, Andreykiv A, Van Oosterwyck H, et al. Numerical simulation of tissue differentiation around loaded titanium implants in a bone chamber. J Biomech 2004;37:763-769.
    • (2004) J Biomech , vol.37 , pp. 763-769
    • Geris, L.1    Andreykiv, A.2    Van Oosterwyck, H.3
  • 16
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
    • Isidor F. Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 1996;7:143-152.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 143-152
    • Isidor, F.1
  • 17
    • 0031061799 scopus 로고    scopus 로고
    • Histological evaluation of periimplant bone at implants subjected to occlusal overload or plaque accumulation
    • Isidor F. Histological evaluation of periimplant bone at implants subjected to occlusal overload or plaque accumulation. Clin Oral Implants Res 1997;8:1-9.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 1-9
    • Isidor, F.1
  • 18
    • 84995804550 scopus 로고
    • Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling
    • Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 19
    • 0023492075 scopus 로고
    • Bone "mass" and the "mechanostat": A proposal
    • Frost HM. Bone "mass" and the "mechanostat": A proposal. Anat Rec 1987;219:1-9.
    • (1987) Anat Rec , vol.219 , pp. 1-9
    • Frost, H.M.1
  • 20
    • 18044403181 scopus 로고    scopus 로고
    • The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study
    • Duyck J, Ronald HJ, Van Oosterwyck H, Naert I, Vander Sloten J, Ellingsen JE. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study. Clin Oral Implants Res 2001;12:207-218.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 207-218
    • Duyck, J.1    Ronald, H.J.2    Van Oosterwyck, H.3    Naert, I.4    Vander Sloten, J.5    Ellingsen, J.E.6
  • 21
    • 9944241763 scopus 로고    scopus 로고
    • Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis
    • Bozkaya D, Muftu S, Muftu A. Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis. J Prosthet Dent 2004;92:523-530.
    • (2004) J Prosthet Dent , vol.92 , pp. 523-530
    • Bozkaya, D.1    Muftu, S.2    Muftu, A.3
  • 22
    • 34250200457 scopus 로고    scopus 로고
    • Effect of constant strain rate, composed by varying amplitude and frequency, of early loading on peri-implant bone (re)modelling
    • De Smet E, Jaecques SVN, Jansen JJ, et al. Effect of constant strain rate, composed by varying amplitude and frequency, of early loading on peri-implant bone (re)modelling. J Clin Periodontol 2007;34:618-624.
    • (2007) J Clin Periodontol , vol.34 , pp. 618-624
    • De Smet, E.1    Jaecques, S.V.N.2    Jansen, J.J.3
  • 23
    • 33846378773 scopus 로고    scopus 로고
    • Influence of controlled immediate loading and implant design on peri-implant bone formation
    • Vandamme K, Naert I, Geris L, Vander Sloten J, Puers R, Duyck J. Influence of controlled immediate loading and implant design on peri-implant bone formation. J Clin Periodontol 2007;34:172-181.
    • (2007) J Clin Periodontol , vol.34 , pp. 172-181
    • Vandamme, K.1    Naert, I.2    Geris, L.3    Vander Sloten, J.4    Puers, R.5    Duyck, J.6
  • 24
    • 77955257108 scopus 로고    scopus 로고
    • Influence of implant connection type on the biomechanical environment of immediately placed implants: CT-based nonlinear, 3D finite element analysis
    • Pessoa RS, Muraru L, Marcantonio E Jr, et al. Influence of implant connection type on the biomechanical environment of immediately placed implants: CT-based nonlinear, 3D finite element analysis. Clin Implant Dent Relat Res 2010;12:219-234.
    • (2010) Clin Implant Dent Relat Res , vol.12 , pp. 219-234
    • Pessoa, R.S.1    Muraru, L.2    Marcantonio Jr, E.3
  • 25
    • 79952058637 scopus 로고    scopus 로고
    • Biomechanical evaluation of platform switching in different implant protocols: Computed tomography-based threedimensional finite element analysis
    • Pessoa RS, Vaz LG, Marcantonio E Jr, Vander Sloten J, Duyck J, Jaecques SVN. Biomechanical evaluation of platform switching in different implant protocols: Computed tomography-based threedimensional finite element analysis. Int J Oral Maxillofac Implant 2010;25:911-919.
    • (2010) Int J Oral Maxillofac Implant , vol.25 , pp. 911-919
    • Pessoa, R.S.1    Vaz, L.G.2    Marcantonio Jr, E.3    Vander Sloten, J.4    Duyck, J.5    Jaecques, S.V.N.6
  • 26
    • 21344466549 scopus 로고    scopus 로고
    • A positive correlation between occlusal trauma and peri-implant bone loss:Literature support
    • Misch CE, Suzuki JB, Misch-Dietsh FM, Bidez MW. A positive correlation between occlusal trauma and peri-implant bone loss:Literature support. Implant Dent 2005;14:108-116.
    • (2005) Implant Dent , vol.14 , pp. 108-116
    • Misch, C.E.1    Suzuki, J.B.2    Misch-Dietsh, F.M.3    Bidez, M.W.4
  • 27
    • 0033212422 scopus 로고    scopus 로고
    • The implant neck: Smooth or provided with retention elements: A biomechanical approach
    • Hansson S. The implant neck: Smooth or provided with retention elements: A biomechanical approach, Clin Oral Implants Res 1999;10:394-405.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 394-405
    • Hansson, S.1
  • 28
    • 43049178206 scopus 로고    scopus 로고
    • Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: A non-linear finite element study
    • Huang HL, Hsu JT, Fuh LJ, Tu MG, Ko CC, Shen YW. Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: A non-linear finite element study. J Dent 2008;36:409-417.
    • (2008) J Dent , vol.36 , pp. 409-417
    • Huang, H.L.1    Hsu, J.T.2    Fuh, L.J.3    Tu, M.G.4    Ko, C.C.5    Shen, Y.W.6
  • 29
    • 70449360693 scopus 로고    scopus 로고
    • Micromotion and stress distribution of immediate loaded implants: A finite element analysis
    • Fazel A, Aalai S, Rismanchian M, Sadr-Eshkevari P. Micromotion and stress distribution of immediate loaded implants: A finite element analysis. Clin Implant Dent Relat Res 2009;11:267-271.
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 267-271
    • Fazel, A.1    Aalai, S.2    Rismanchian, M.3    Sadr-Eshkevari, P.4
  • 30
    • 70449381091 scopus 로고    scopus 로고
    • Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants
    • Ding X, Liao S-H, Zhu X-H, Zhang X-H, Zhang L. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants. Clin Implant Dent Relat Res 2009;11:279-287.
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 279-287
    • Ding, X.1    Liao, S.-H.2    Zhu, X.-H.3    Zhang, X.-H.4    Zhang, L.5
  • 32
    • 0345862402 scopus 로고    scopus 로고
    • Individualised, micro CT-based finite element modelling as a tool for biomechanical analysis related to tissue engineering of bone
    • Jaecques SVN, Van Oosterwyck H, Muraru L, et al. Individualised, micro CT-based finite element modelling as a tool for biomechanical analysis related to tissue engineering of bone. Biomaterials 2004;25:1683-1696.
    • (2004) Biomaterials , vol.25 , pp. 1683-1696
    • Jaecques, S.V.N.1    Van Oosterwyck, H.2    Muraru, L.3
  • 33
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001;85:585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.2    Liu, G.R.3
  • 34
    • 0034218915 scopus 로고    scopus 로고
    • Mechanics of the implantabutment connection: An 8-degree taper compared to a butt joint connection
    • Merz BR, Hunenbart S, Belser UC. Mechanics of the implantabutment connection: An 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-526.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 519-526
    • Merz, B.R.1    Hunenbart, S.2    Belser, U.C.3
  • 36
    • 0036348012 scopus 로고    scopus 로고
    • Statistical methods in finite element analysis
    • Dar FH, Meakina JR, Aspden RM. Statistical methods in finite element analysis. J Biomech 2002;35:1155-1161.
    • (2002) J Biomech , vol.35 , pp. 1155-1161
    • Dar, F.H.1    Meakina, J.R.2    Aspden, R.M.3
  • 37
    • 0036689634 scopus 로고    scopus 로고
    • Healing of marginal defects at implants placed in fresh extraction sockets or after 4-6 weeks of healing. A comparative study
    • Nemcovsky CE, Artzi Z, Moses O, Gelernter I. Healing of marginal defects at implants placed in fresh extraction sockets or after 4-6 weeks of healing. A comparative study. Clin Oral Implants Res 2002;13:410-419.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 410-419
    • Nemcovsky, C.E.1    Artzi, Z.2    Moses, O.3    Gelernter, I.4
  • 38
    • 0038749490 scopus 로고    scopus 로고
    • Bone healing following immediate versus delayed placement of titanium implants into extraction sockets: A retrospective clinical study
    • Schropp L, Kostopoulos L, Wenzel A. Bone healing following immediate versus delayed placement of titanium implants into extraction sockets: A retrospective clinical study. Int J Oral Maxillofac Implants 2003;18:189-199.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 189-199
    • Schropp, L.1    Kostopoulos, L.2    Wenzel, A.3
  • 39
    • 18744396684 scopus 로고    scopus 로고
    • Implant design and intraosseous stability of immediately placed implants:A human cadaver study
    • Akkocaoglu M, Uysal S, Tekdemir I, Akca K, Cehreli MC. Implant design and intraosseous stability of immediately placed implants:A human cadaver study. Clin Oral Implants Res 2005;16:202-209.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 202-209
    • Akkocaoglu, M.1    Uysal, S.2    Tekdemir, I.3    Akca, K.4    Cehreli, M.C.5
  • 40
    • 0025807515 scopus 로고
    • Axial movement and tibial fractures. A controlled randomized trial of treatment
    • Kenwright J, Richardson JB, Cunningham JL, et al. Axial movement and tibial fractures. A controlled randomized trial of treatment. J Bone Joint Surg Br 1991;73:654-659.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 654-659
    • Kenwright, J.1    Richardson, J.B.2    Cunningham, J.L.3
  • 41
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
    • Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature. J Biomed Mater Res 1998;43:192-203.
    • (1998) J Biomed Mater Res , vol.43 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3    Dubruille, J.H.4
  • 42
    • 77954862317 scopus 로고    scopus 로고
    • The effect of thread design on stress distribution in a solid screw implant: A 3D finite element analysis
    • Eraslan O, Inan O. The effect of thread design on stress distribution in a solid screw implant: A 3D finite element analysis. Clin Oral Investig 2010;14:411-416.
    • (2010) Clin Oral Investig , vol.14 , pp. 411-416
    • Eraslan, O.1    Inan, O.2
  • 43
    • 0035458527 scopus 로고    scopus 로고
    • A bioengineered implant for a predetermined bone cellular response to loading forces. A literature review and case report
    • Misch CE, Bidez MW, Sharawy M. A bioengineered implant for a predetermined bone cellular response to loading forces. A literature review and case report. J Periodontol 2001;72:1276-1286.
    • (2001) J Periodontol , vol.72 , pp. 1276-1286
    • Misch, C.E.1    Bidez, M.W.2    Sharawy, M.3
  • 44
  • 45
    • 7044249030 scopus 로고    scopus 로고
    • Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants
    • Bozkaya D, Müftü S. Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants. J Biomech 2005;38:87-97.
    • (2005) J Biomech , vol.38 , pp. 87-97
    • Bozkaya, D.1    Müftü, S.2
  • 46
    • 84988999869 scopus 로고
    • Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
    • Siegele D, Soltesz U. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants 1989;4:333-340.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 333-340
    • Siegele, D.1    Soltesz, U.2
  • 47
    • 0034570059 scopus 로고    scopus 로고
    • Implant-abutment interface: Biomechanical study of flat top versus conical
    • Hansson S. Implant-abutment interface: Biomechanical study of flat top versus conical. Clin Implant Dent Relat Res 2000;2:33-41.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 33-41
    • Hansson, S.1
  • 48
    • 0346461396 scopus 로고    scopus 로고
    • Influence of implant length and diameter on stress distribution: A finite element analysis
    • Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distribution: A finite element analysis. J Prosthet Dent 2004;91:20-25.
    • (2004) J Prosthet Dent , vol.91 , pp. 20-25
    • Himmlova, L.1    Dostalova, T.2    Kacovsky, A.3    Konvickova, S.4
  • 49
    • 0041418181 scopus 로고    scopus 로고
    • Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    • Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2003;18:357-368.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 357-368
    • Tada, S.1    Stegaroiu, R.2    Kitamura, E.3    Miyakawa, O.4    Kusakari, H.5
  • 50
    • 0021676239 scopus 로고
    • Static vs dynamic loads as an influence on bone remodelling
    • Lanyon LE, Rubin CT. Static vs dynamic loads as an influence on bone remodelling. J Biomech 1984;17:897-905.
    • (1984) J Biomech , vol.17 , pp. 897-905
    • Lanyon, L.E.1    Rubin, C.T.2
  • 51
    • 0034896710 scopus 로고    scopus 로고
    • Modulation of appositional and longitudinal bone growth in the rat ulna by applied static and dynamic force
    • Robling AG, Duijvelaar KM, Geevers JV, Ohashi N, Turner CH. Modulation of appositional and longitudinal bone growth in the rat ulna by applied static and dynamic force. Bone 2001;29:105-113.
    • (2001) Bone , vol.29 , pp. 105-113
    • Robling, A.G.1    Duijvelaar, K.M.2    Geevers, J.V.3    Ohashi, N.4    Turner, C.H.5
  • 52
    • 0027992966 scopus 로고
    • The response of rat tibiae to incremental bouts of mechanical loading: A quantum concept for bone formation
    • Forwood MR, Turner CH. The response of rat tibiae to incremental bouts of mechanical loading: A quantum concept for bone formation. Bone 1994;15:603-609.
    • (1994) Bone , vol.15 , pp. 603-609
    • Forwood, M.R.1    Turner, C.H.2
  • 53
    • 0035064222 scopus 로고    scopus 로고
    • Effects of loading frequency on mechanically induced bone formation
    • Hsieh YF, Turner CH. Effects of loading frequency on mechanically induced bone formation. J Bone Miner Res 2001;16:918-924.
    • (2001) J Bone Miner Res , vol.16 , pp. 918-924
    • Hsieh, Y.F.1    Turner, C.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.