메뉴 건너뛰기




Volumn 62, Issue 2, 2012, Pages 648-651

Correction of geometric distortion in fMRI data

Author keywords

Echo planar imaging; FMRI; Functional magnetic resonance imaging; Geometric distortions

Indexed keywords

ANALYTICAL PARAMETERS; DATA PROCESSING; ECHO PLANAR IMAGING; FUNCTIONAL MAGNETIC RESONANCE IMAGING; GEOMETRIC DISTORTION; HEAD MOVEMENT; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; NATIONAL HEALTH ORGANIZATION; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; REVIEW; SIGNAL PROCESSING; STATISTICAL ANALYSIS;

EID: 84863007553     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2011.09.010     Document Type: Review
Times cited : (69)

References (20)
  • 1
    • 0142074685 scopus 로고    scopus 로고
    • How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    • Andersson J.L., Skare S., Ashburner J. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage 2003, 20(2):870-888.
    • (2003) Neuroimage , vol.20 , Issue.2 , pp. 870-888
    • Andersson, J.L.1    Skare, S.2    Ashburner, J.3
  • 2
    • 85027958019 scopus 로고    scopus 로고
    • An improved PSF mapping method for EPI distortion correction in human brain at ultra high field (7T)
    • Chung J.Y., In M.H., Oh S.H., Zaitsev M., Speck O., Cho Z.H. An improved PSF mapping method for EPI distortion correction in human brain at ultra high field (7T). MAGMA 2011, 24(3):179-190.
    • (2011) MAGMA , vol.24 , Issue.3 , pp. 179-190
    • Chung, J.Y.1    In, M.H.2    Oh, S.H.3    Zaitsev, M.4    Speck, O.5    Cho, Z.H.6
  • 3
    • 77955104403 scopus 로고    scopus 로고
    • Reducing distortions in diffusion-weighted echo planar imaging with a dual-echo blip-reversed sequence
    • Gallichan D., Andersson J.L., Jenkinson M., Robson M.D., Miller K.L. Reducing distortions in diffusion-weighted echo planar imaging with a dual-echo blip-reversed sequence. Magn. Reson. Med. 2010, 64(2):382-390.
    • (2010) Magn. Reson. Med. , vol.64 , Issue.2 , pp. 382-390
    • Gallichan, D.1    Andersson, J.L.2    Jenkinson, M.3    Robson, M.D.4    Miller, K.L.5
  • 4
    • 75349084742 scopus 로고    scopus 로고
    • Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging
    • Holland D., Kuperman J.M., Dale A.M. Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging. Neuroimage 2010, 50(1):175-183.
    • (2010) Neuroimage , vol.50 , Issue.1 , pp. 175-183
    • Holland, D.1    Kuperman, J.M.2    Dale, A.M.3
  • 6
    • 0037225733 scopus 로고    scopus 로고
    • Fast, automated, N-dimensional phase-unwrapping algorithm
    • Jenkinson M. Fast, automated, N-dimensional phase-unwrapping algorithm. Magn. Reson. Med. 2003, 49(1):193-197.
    • (2003) Magn. Reson. Med. , vol.49 , Issue.1 , pp. 193-197
    • Jenkinson, M.1
  • 7
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from B0 field variations
    • Jezzard P., Balaban R.S. Correction for geometric distortion in echo planar images from B0 field variations. Magn. Reson. Med. 1995, 34(1):65-73.
    • (1995) Magn. Reson. Med. , vol.34 , Issue.1 , pp. 65-73
    • Jezzard, P.1    Balaban, R.S.2
  • 8
    • 0032883422 scopus 로고    scopus 로고
    • Sources of distortion in functional MRI data
    • Jezzard P., Clare S. Sources of distortion in functional MRI data. Hum. Brain Mapp. 1999, 8(2-3):80-85.
    • (1999) Hum. Brain Mapp. , vol.8 , Issue.2-3 , pp. 80-85
    • Jezzard, P.1    Clare, S.2
  • 9
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P. Multi-planar image formation using NMR spin echoes. J. Phys. Chem. 1977, 10:L55-L58.
    • (1977) J. Phys. Chem. , vol.10
    • Mansfield, P.1
  • 10
    • 1842590302 scopus 로고    scopus 로고
    • Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method
    • Morgan P.S., Bowtell R.W., McIntyre D.J., Worthington B.S. Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method. J. Magn. Reson. Imaging 2004, 19(4):499-507.
    • (2004) J. Magn. Reson. Imaging , vol.19 , Issue.4 , pp. 499-507
    • Morgan, P.S.1    Bowtell, R.W.2    McIntyre, D.J.3    Worthington, B.S.4
  • 12
    • 0031910857 scopus 로고    scopus 로고
    • Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps
    • Reber P.J., Wong E.C., Buxton R.B., Frank L.R. Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps. Magn. Reson. Med. 1998, 39(2):328-330.
    • (1998) Magn. Reson. Med. , vol.39 , Issue.2 , pp. 328-330
    • Reber, P.J.1    Wong, E.C.2    Buxton, R.B.3    Frank, L.R.4
  • 13
    • 0030726765 scopus 로고    scopus 로고
    • Measurement of the point spread function in MRI using constant time imaging
    • Robson M.D., Gore J.C., Constable R.T. Measurement of the point spread function in MRI using constant time imaging. Magn. Reson. Med. 1997, 38(5):733-740.
    • (1997) Magn. Reson. Med. , vol.38 , Issue.5 , pp. 733-740
    • Robson, M.D.1    Gore, J.C.2    Constable, R.T.3
  • 14
    • 0141840792 scopus 로고    scopus 로고
    • Single-shot magnetic field mapping embedded in echo-planar time-course imaging
    • Roopchansingh V., Cox R.W., Jesmanowicz A., Ward B.D., Hyde J.S. Single-shot magnetic field mapping embedded in echo-planar time-course imaging. Magn. Reson. Med. 2003, 50(4):839-843.
    • (2003) Magn. Reson. Med. , vol.50 , Issue.4 , pp. 839-843
    • Roopchansingh, V.1    Cox, R.W.2    Jesmanowicz, A.3    Ward, B.D.4    Hyde, J.S.5
  • 15
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays
    • Sodickson D.K., Manning W.J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn. Reson. Med. 1997, 38(4):591-603.
    • (1997) Magn. Reson. Med. , vol.38 , Issue.4 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 16
    • 0002112769 scopus 로고
    • Correcting gross distortion on echo planar images
    • Weiskoff R.M., Davis T.L. Correcting gross distortion on echo planar images. Proc. SMRM. 1992, 4515.
    • (1992) Proc. SMRM. , pp. 4515
    • Weiskoff, R.M.1    Davis, T.L.2
  • 17
    • 12844268705 scopus 로고    scopus 로고
    • Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRI
    • Weiskopf N., Klose U., Birbaumer N., Mathiak K. Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRI. Neuroimage 2005, 24(4):1068-1079.
    • (2005) Neuroimage , vol.24 , Issue.4 , pp. 1068-1079
    • Weiskopf, N.1    Klose, U.2    Birbaumer, N.3    Mathiak, K.4
  • 18
    • 0028067128 scopus 로고
    • The design and test of a new volume coil for high field imaging
    • Wen H., Chesnick A.S., Balaban R.S. The design and test of a new volume coil for high field imaging. Magn. Reson. Med. 1994, 32(4):492-498.
    • (1994) Magn. Reson. Med. , vol.32 , Issue.4 , pp. 492-498
    • Wen, H.1    Chesnick, A.S.2    Balaban, R.S.3
  • 19
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and reslicing PET images
    • Woods R.P., Cherry S.R., Mazziotta J.C. Rapid automated algorithm for aligning and reslicing PET images. J. Comput. Assist. Tomogr. 1992, 16(4):620-633.
    • (1992) J. Comput. Assist. Tomogr. , vol.16 , Issue.4 , pp. 620-633
    • Woods, R.P.1    Cherry, S.R.2    Mazziotta, J.C.3
  • 20
    • 7544248836 scopus 로고    scopus 로고
    • Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction
    • Zaitsev M., Hennig J., Speck O. Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction. Magn. Reson. Med. 2004, 52(5):1156-1166.
    • (2004) Magn. Reson. Med. , vol.52 , Issue.5 , pp. 1156-1166
    • Zaitsev, M.1    Hennig, J.2    Speck, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.