메뉴 건너뛰기




Volumn 7, Issue 2, 2012, Pages 225-231

Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA

Author keywords

2D 3D reconstruction; Cup orientation; Statistical shape model; Total hip arthroplasty; X ray radiograph

Indexed keywords

ACCURACY; ACETABULUM; ADULT; AGED; ANTHROPOMETRIC PARAMETERS; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CUP ORIENTATION; FEMALE; HUMAN; IMAGE RECONSTRUCTION; MALE; PELVIS RADIOGRAPHY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY; RETROSPECTIVE STUDY; SYSTEMATIC ERROR; THREE DIMENSIONAL IMAGING; TOTAL HIP PROSTHESIS; TWO DIMENSIONAL IMAGING; VALIDATION STUDY;

EID: 84863004959     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-011-0644-7     Document Type: Article
Times cited : (24)

References (33)
  • 2
    • 0025679123 scopus 로고
    • Dislocation after total hip arthroplasty. Causes and prevention
    • McCollum DE, Gray WJG (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop 261:159-170
    • (1990) Clin Orthop , vol.261 , pp. 159-170
    • McCollum, D.E.1    Gray, W.J.G.2
  • 4
    • 0034945667 scopus 로고    scopus 로고
    • The effects of implant position, design and wear on the range of motion after total hip arthroplasty
    • Bader RJ, Steinhauser E, Willmann G, Gradinger R (2001) The effects of implant position, design and wear on the range of motion after total hip arthroplasty. Hip Int 11:80-90
    • (2001) Hip Int , vol.11 , pp. 80-90
    • Bader, R.J.1    Steinhauser, E.2    Willmann, G.3    Gradinger, R.4
  • 7
    • 34547791362 scopus 로고    scopus 로고
    • Containment versus impingement: Finding a compromise for cup placement in total hip arthroplasty
    • Widmer KH (2007) Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty. Int Orthop 31(suppl 1):S29-S33
    • (2007) Int Orthop , vol.31 , Issue.SUPPL. 1
    • Widmer, K.H.1
  • 8
    • 33646079156 scopus 로고    scopus 로고
    • Position of the acetabular cup-accuracy of radiographic calculation compared to CT-based measurement
    • Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J (2006) Position of the acetabular cup-accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58: 294-300
    • (2006) Eur J Radiol , vol.58 , pp. 294-300
    • Kalteis, T.1    Handel, M.2    Herold, T.3    Perlick, L.4    Paetzel, C.5    Grifka, J.6
  • 9
    • 33746878867 scopus 로고    scopus 로고
    • Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
    • Marx A, von Knoch M, Pförtner J, Wiese M, Saxler G (2006) Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg 126:487-492
    • (2006) Arch Orthop Trauma Surg , vol.126 , pp. 487-492
    • Marx, A.1    Von Knoch, M.2    Pförtner, J.3    Wiese, M.4    Saxler, G.5
  • 10
    • 24344492709 scopus 로고    scopus 로고
    • Tilt and rotation correction of acetabular version on pelvic radiographs
    • Tannast M, Zheng G, Anderegg C et al (2005) Tilt and rotation correction of acetabular version on pelvic radiographs. Clin Orthop 438:182-190
    • (2005) Clin Orthop , vol.438 , pp. 182-190
    • Tannast, M.1    Zheng, G.2    Anderegg, C.3
  • 11
    • 0033050961 scopus 로고    scopus 로고
    • Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs
    • Pradhan R (1999) Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg Br 81(B):431-435
    • (1999) J Bone Joint Surg Br , vol.81 , Issue.B , pp. 431-435
    • Pradhan, R.1
  • 12
    • 1942422237 scopus 로고    scopus 로고
    • A simplified method to determine acetabular cup anteversion from plain radiographs
    • Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 19:387-390
    • (2004) J Arthroplasty , vol.19 , pp. 387-390
    • Widmer, K.H.1
  • 13
    • 1642540073 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: Evaluation at a minimum of 20 years
    • Della Valle CJ, Kaplan K, Jazrawi A, Ahmed S, Jaffe WL (2004) Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years. J Arthroplasty 19:23-26
    • (2004) J Arthroplasty , vol.19 , pp. 23-26
    • Della Valle, C.J.1    Kaplan, K.2    Jazrawi, A.3    Ahmed, S.4    Jaffe, W.L.5
  • 14
    • 74249097495 scopus 로고    scopus 로고
    • Minimal radiation dose computed tomography for measurement of cup orientation in total hip arthroplasty
    • Arai N, Nakamura S, Matsushita T, Suzuki S (2010) Minimal radiation dose computed tomography for measurement of cup orientation in total hip arthroplasty. J Arthroplasty 25:263-267
    • (2010) J Arthroplasty , vol.25 , pp. 263-267
    • Arai, N.1    Nakamura, S.2    Matsushita, T.3    Suzuki, S.4
  • 16
    • 27244451801 scopus 로고    scopus 로고
    • Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching
    • Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia AM (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10:37-43
    • (2005) Comput Aided Surg , vol.10 , pp. 37-43
    • Blendea, S.1    Eckman, K.2    Jaramaz, B.3    Levison, T.J.4    Digioia, A.M.5
  • 20
    • 77958151892 scopus 로고    scopus 로고
    • Computer assisted determination of ace-tabular cup orientation using 2D-3D image registration
    • Zheng G, Zhang X (2010) Computer assisted determination of ace-tabular cup orientation using 2D-3D image registration. Int J CARS 5:437-447
    • (2010) Int J CARS , vol.5 , pp. 437-447
    • Zheng, G.1    Zhang, X.2
  • 21
    • 72049132419 scopus 로고    scopus 로고
    • Validation of a new method for determination of cup orientation in THA
    • Steppacher SD, Tannast M, Zheng G et al (2009) Validation of a new method for determination of cup orientation in THA. J Orthop Res 27:1583-1588
    • (2009) J Orthop Res , vol.27 , pp. 1583-1588
    • Steppacher, S.D.1    Tannast, M.2    Zheng, G.3
  • 22
    • 0031690023 scopus 로고    scopus 로고
    • Computer assisted measurement of cup placement in total hip replacement
    • Jaramaz B, DiGioia AM, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70-81
    • (1998) Clin Orthop , vol.354 , pp. 70-81
    • Jaramaz, B.1    Digioia, A.M.2    Blackwell, M.3    Nikou, C.4
  • 24
  • 26
    • 77956735395 scopus 로고    scopus 로고
    • Statistically deformable 2D/3D registration for estimating post-operative cup orientation from a single standard AP X-ray radiograph
    • Zheng G (2010) Statistically deformable 2D/3D registration for estimating post-operative cup orientation from a single standard AP X-ray radiograph. Ann Biomed Eng 38(9):2910-2927
    • (2010) Ann Biomed Eng , vol.38 , Issue.9 , pp. 2910-2927
    • Zheng, G.1
  • 27
    • 0020053240 scopus 로고
    • Analysis of version in the acetabular cup
    • Seradge H, Nagle KR, Miller RJ (1982) Analysis of version in the acetabular cup. Clin Orthop 166:152-157
    • (1982) Clin Orthop , vol.166 , pp. 152-157
    • Seradge, H.1    Nagle, K.R.2    Miller, R.J.3
  • 28
    • 0029975750 scopus 로고    scopus 로고
    • Measurement error and correlation coefficients
    • Bland JM, Altman DG (1996) Measurement error and correlation coefficients. BMJ 313(7048):41-42
    • (1996) BMJ , vol.313 , Issue.7048 , pp. 41-42
    • Bland, J.M.1    Altman, D.G.2
  • 29
    • 84863007873 scopus 로고    scopus 로고
    • http://faculty.vassar.edu/lowry/webtext.html
  • 30
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 32
    • 49649103408 scopus 로고    scopus 로고
    • Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetab-ular cup in total hip arthroplasty: A cadaver study
    • Lin F, Lim D, Wixson RL, Milos S, Hendrix RW, Makhsous M (2008) Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetab-ular cup in total hip arthroplasty: a cadaver study. Clin Biomech 23:1004-1011
    • (2008) Clin Biomech , vol.23 , pp. 1004-1011
    • Lin, F.1    Lim, D.2    Wixson, R.L.3    Milos, S.4    Hendrix, R.W.5    Makhsous, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.