메뉴 건너뛰기




Volumn 436, Issue , 2005, Pages 144-150

Anatomic referencing of cup orientation in total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ADULT; AGED; ARTICLE; CALCULATION; CLINICAL ARTICLE; COMPUTER; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER MODEL; CONTROLLED STUDY; FEMALE; HUMAN; MALE; MEASUREMENT; NOMOGRAM; PELVIS; PELVIS RADIOGRAPHY; PRIORITY JOURNAL; TOTAL HIP PROSTHESIS;

EID: 21844460572     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/01.blo.0000157657.22894.29     Document Type: Article
Times cited : (145)

References (34)
  • 2
    • 0035676423 scopus 로고    scopus 로고
    • Computer assisted navigated cup placement of different cup types in hip arthroplasty: A randomised controlled trial
    • Bernsmann K, Langlotz U, Ansari B, Wiese M: Computer assisted navigated cup placement of different cup types in hip arthroplasty: A randomised controlled trial. Z Orthop Ihre Grenzgeb 139:512-517, 2001.
    • (2001) Z Orthop Ihre Grenzgeb , vol.139 , pp. 512-517
    • Bernsmann, K.1    Langlotz, U.2    Ansari, B.3    Wiese, M.4
  • 3
    • 0032178167 scopus 로고    scopus 로고
    • The Otto Aufranc Award: Image guided navigation system to measure intraoperatively acetabular implant alignment
    • DiGioia AM, Jaramaz B, Blackwell M, et al: The Otto Aufranc Award: Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8-22, 1998.
    • (1998) Clin Orthop , vol.355 , pp. 8-22
    • DiGioia, A.M.1    Jaramaz, B.2    Blackwell, M.3
  • 4
    • 0036220612 scopus 로고    scopus 로고
    • Comparison of a mechanical acetabular alignment guide with computer placement of the socket
    • DiGioia AM, Jaramaz B, Plakseychuk AY, et al: Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17:359-364, 2002.
    • (2002) J Arthroplasty , vol.17 , pp. 359-364
    • DiGioia, A.M.1    Jaramaz, B.2    Plakseychuk, A.Y.3
  • 5
    • 12244291275 scopus 로고    scopus 로고
    • Device for accurately siting the acetabular component during total hip replacement
    • Doyle J, Farmer MH, Shepard G: Device for accurately siting the acetabular component during total hip replacement. Arch Orthop Trauma Surg 122:554-556, 2002.
    • (2002) Arch Orthop Trauma Surg , vol.122 , pp. 554-556
    • Doyle, J.1    Farmer, M.H.2    Shepard, G.3
  • 7
    • 0034984549 scopus 로고    scopus 로고
    • Variations of pelvic anteversion in the lying and standing positions: Analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup
    • Eddine TA, Migaud H, Chantelot C, et al: Variations of pelvic anteversion in the lying and standing positions: Analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup. Surg Radiol Anat 23:105-110, 2001.
    • (2001) Surg Radiol Anat , vol.23 , pp. 105-110
    • Eddine, T.A.1    Migaud, H.2    Chantelot, C.3
  • 8
    • 0019057926 scopus 로고
    • Dislocation in total hip arthroplasties
    • Fackler CD, Poss R: Dislocation in total hip arthroplasties. Clin Orthop 151:169-178, 1980.
    • (1980) Clin Orthop , vol.151 , pp. 169-178
    • Fackler, C.D.1    Poss, R.2
  • 9
    • 0026694342 scopus 로고
    • Dislocation in low-friction arthroplasty
    • Garcia-Cimbrelo E, Munuera L: Dislocation in low-friction arthroplasty. J Arthroplasty 7:149-155, 1992.
    • (1992) J Arthroplasty , vol.7 , pp. 149-155
    • Garcia-Cimbrelo, E.1    Munuera, L.2
  • 10
    • 0018412046 scopus 로고
    • Radiographic localization of the acetabular component of a hip prosthesis
    • Ghelman B: Radiographic localization of the acetabular component of a hip prosthesis. Radiology 130:540-542, 1979.
    • (1979) Radiology , vol.130 , pp. 540-542
    • Ghelman, B.1
  • 11
    • 0017622529 scopus 로고
    • Roentgenographic measurements after Müller total hip replacement
    • Gore DR, Murray MP, Gardner GM, Sepic SB: Roentgenographic measurements after Müller total hip replacement. J Bone Joint Surg 59A:948-953, 1977.
    • (1977) J Bone Joint Surg , vol.59 A , pp. 948-953
    • Gore, D.R.1    Murray, M.P.2    Gardner, G.M.3    Sepic, S.B.4
  • 13
    • 0023943689 scopus 로고
    • Comparison of two- and three dimensional methods for assessment of orientation of the total hip prosthesis
    • Herrlin K, Pettersson H, Selvik G: Comparison of two- and three dimensional methods for assessment of orientation of the total hip prosthesis. Acta Radiol 29:357-361, 1988.
    • (1988) Acta Radiol , vol.29 , pp. 357-361
    • Herrlin, K.1    Pettersson, H.2    Selvik, G.3
  • 15
    • 0032822724 scopus 로고    scopus 로고
    • Fluoroscopy as an imaging means for computer assisted surgical navigation
    • Hofstetter R, Slomczykowski M, Sati M, Nolte LP: Fluoroscopy as an imaging means for computer assisted surgical navigation. Comput Aided Surg 4:65-76, 1999.
    • (1999) Comput Aided Surg , vol.4 , pp. 65-76
    • Hofstetter, R.1    Slomczykowski, M.2    Sati, M.3    Nolte, L.P.4
  • 16
    • 0031690023 scopus 로고    scopus 로고
    • Computer assisted measurement of cup placement in total hip replacement
    • Jaramaz B, DiGioia AM, Blackwell M, Nolan DR: Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70-80, 1998.
    • (1998) Clin Orthop , vol.354 , pp. 70-80
    • Jaramaz, B.1    DiGioia, A.M.2    Blackwell, M.3    Nolan, D.R.4
  • 19
    • 0015632760 scopus 로고
    • Prosthetic hip annulation
    • McLaren RH: Prosthetic hip annulation. Radiology 107:705-706, 1973.
    • (1973) Radiology , vol.107 , pp. 705-706
    • McLaren, R.H.1
  • 20
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray DW: The definition and measurement of acetabular orientation. J Bone Joint Surg 756:228-232, 1993.
    • (1993) J Bone Joint Surg , vol.756 , pp. 228-232
    • Murray, D.W.1
  • 21
    • 0037904381 scopus 로고    scopus 로고
    • Measurements of pelvic flexion angle using three-dimensional computed tomography
    • Nishihara S, Sugano N, Nishii T, Ohzono K, Yoshikawa H: Measurements of pelvic flexion angle using three-dimensional computed tomography. Clin Orthop 411:140-151, 2003.
    • (2003) Clin Orthop , vol.411 , pp. 140-151
    • Nishihara, S.1    Sugano, N.2    Nishii, T.3    Ohzono, K.4    Yoshikawa, H.5
  • 22
    • 3042657286 scopus 로고    scopus 로고
    • A new method for measuring cup orientation after total hip arthroplasty
    • Olivecrona H, Weidenhielm L, Olivecrona L, et al: A new method for measuring cup orientation after total hip arthroplasty. Acta Orthop Scand 75:252-260, 2004.
    • (2004) Acta Orthop Scand , vol.75 , pp. 252-260
    • Olivecrona, H.1    Weidenhielm, L.2    Olivecrona, L.3
  • 23
    • 0019997368 scopus 로고
    • Radiologic evaluation of the positon of the acetabular component of the total hip prosthesis
    • Pettersson H, Gentz CF, Lindberg O, Carlsson AS: Radiologic evaluation of the positon of the acetabular component of the total hip prosthesis. Acta Radiol Diagn 23:259-263, 1982.
    • (1982) Acta Radiol Diagn , vol.23 , pp. 259-263
    • Pettersson, H.1    Gentz, C.F.2    Lindberg, O.3    Carlsson, A.S.4
  • 24
    • 0029582771 scopus 로고
    • Can simple radiographs be predictive of total hip dislocation?
    • Pollard JA, Daum WJ, Uchida T: Can simple radiographs be predictive of total hip dislocation? J Arthroplasty 10:800-804, 1995.
    • (1995) J Arthroplasty , vol.10 , pp. 800-804
    • Pollard, J.A.1    Daum, W.J.2    Uchida, T.3
  • 25
    • 0037916788 scopus 로고
    • Pelvis
    • Robinson A (ed). London, Henry Frowde and Hodder & Stoughton
    • Robinson A: Pelvis. In Robinson A (ed). Cunningham's Textbook of Anatomy. Ed 5. London, Henry Frowde and Hodder & Stoughton 255-260, 1922.
    • (1922) Cunningham's Textbook of Anatomy. Ed. 5 , pp. 255-260
    • Robinson, A.1
  • 26
    • 3042832037 scopus 로고    scopus 로고
    • A comparison of free-hand and computer assisted cup placement in total hip arthroplasty: A multi-center study
    • Saxler G, Marx A, Vandevelde D, et al: A comparison of free-hand and computer assisted cup placement in total hip arthroplasty: A multi-center study. Z Orthop Ihre Grenzgeb 142:286-291, 2004.
    • (2004) Z Orthop Ihre Grenzgeb , vol.142 , pp. 286-291
    • Saxler, G.1    Marx, A.2    Vandevelde, D.3
  • 27
    • 4344626911 scopus 로고    scopus 로고
    • The accuracy of free-hand cup positioning: A CT-based measurement of cup placement in 105 total hip arthroplasties
    • Saxler G, Marx A, Vandevelde D, et al: The accuracy of free-hand cup positioning: A CT-based measurement of cup placement in 105 total hip arthroplasties. Int Orthop 28:198-201, 2004.
    • (2004) Int Orthop , vol.28 , pp. 198-201
    • Saxler, G.1    Marx, A.2    Vandevelde, D.3
  • 28
    • 0032124945 scopus 로고    scopus 로고
    • Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation
    • Seki M, Yuasa N, Ohkuni K: Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation. J Orthop Res 16:513-517, 1998.
    • (1998) J Orthop Res , vol.16 , pp. 513-517
    • Seki, M.1    Yuasa, N.2    Ohkuni, K.3
  • 29
    • 0020053240 scopus 로고
    • Analysis of version in the acetabular cup
    • Seradge H, Kent RN, Miller RJ: Analysis of version in the acetabular cup. Clin Orthop 166:152-157, 1982.
    • (1982) Clin Orthop , vol.166 , pp. 152-157
    • Seradge, H.1    Kent, R.N.2    Miller, R.J.3
  • 30
    • 0037317035 scopus 로고    scopus 로고
    • Effect of pelvic tilt on acetabular retroversion: A study of pelves from cadavers
    • Siebenrock KA, Kalbermatten DF, Ganz R: Effect of pelvic tilt on acetabular retroversion: A study of pelves from cadavers. Clin Orthop 407:241-248, 2003.
    • (2003) Clin Orthop , vol.407 , pp. 241-248
    • Siebenrock, K.A.1    Kalbermatten, D.F.2    Ganz, R.3
  • 31
    • 0038686674 scopus 로고    scopus 로고
    • Image-based hip navigation
    • Wentzensen A, Zheng G, Vock B, et al: Image-based hip navigation. Int Orthop 27(Suppl):43-46, 2003.
    • (2003) Int Orthop , vol.27 , Issue.SUPPL. , pp. 43-46
    • Wentzensen, A.1    Zheng, G.2    Vock, B.3
  • 32
    • 1942422237 scopus 로고    scopus 로고
    • A simplified method to determine acetabular cup anteversion from plain radiographs
    • Widmer KH: A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 19:387-390, 2004.
    • (2004) J Arthroplasty , vol.19 , pp. 387-390
    • Widmer, K.H.1
  • 33
    • 0020356121 scopus 로고
    • Dislocations after total hip arthroplasty
    • Woo RY, Morrey BF: Dislocations after total hip arthroplasty. J Bone Joint Surg 64A:1295-1306, 1982.
    • (1982) J Bone Joint Surg , vol.64 A , pp. 1295-1306
    • Woo, R.Y.1    Morrey, B.F.2
  • 34
    • 0036393243 scopus 로고    scopus 로고
    • A hybrid CT-free navigation system for total hip arthroplasty
    • Zheng G, Marx A, Langlotz U, et al: A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7:129-145, 2002.
    • (2002) Comput Aided Surg , vol.7 , pp. 129-145
    • Zheng, G.1    Marx, A.2    Langlotz, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.