메뉴 건너뛰기




Volumn 106, Issue 5, 2008, Pages 644-650

Biomechanical and histomorphometric analyses of the osseointegration of microscrews with different surgical techniques in beagle dogs

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ARTICLE; BIOMECHANICS; BONE REGENERATION; BONE SCREW; DENTAL CARE; DENTAL EQUIPMENT; DOG; ELECTRONICS; FEMALE; IMPLANT; JAW; METHODOLOGY; ORTHODONTICS; TOOTH IMPLANTATION;

EID: 53249107200     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.tripleo.2008.05.031     Document Type: Article
Times cited : (19)

References (34)
  • 1
    • 0024780254 scopus 로고
    • The use of Branemark system implants for orthodontics anchorages: report of a case
    • Van Roekel N.B. The use of Branemark system implants for orthodontics anchorages: report of a case. Int J Oral Maxillofac Implants 4 (1989) 341-344
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 341-344
    • Van Roekel, N.B.1
  • 2
    • 0031266937 scopus 로고    scopus 로고
    • Mini-implant for orthodontic anchorage
    • Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 31 (1997) 763-767
    • (1997) J Clin Orthod , vol.31 , pp. 763-767
    • Kanomi, R.1
  • 3
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11 (1998) 491-501
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 4
    • 0018022749 scopus 로고
    • Über die Anlagerung von Osteozement an einen belasteten Implantatkörper
    • Schroeder A., Stich H., Straumann F., and Sutter F. Über die Anlagerung von Osteozement an einen belasteten Implantatkörper. Schweiz Monatsschr Zahnmed 88 (1978) 1051-1058
    • (1978) Schweiz Monatsschr Zahnmed , vol.88 , pp. 1051-1058
    • Schroeder, A.1    Stich, H.2    Straumann, F.3    Sutter, F.4
  • 5
    • 0026167719 scopus 로고
    • Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed protheses
    • Friberg B., Jemt T., and Lekholm U. Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed protheses. Int J Oral Maxillofac Implants 6 (1991) 142-146
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 142-146
    • Friberg, B.1    Jemt, T.2    Lekholm, U.3
  • 6
    • 0030155796 scopus 로고    scopus 로고
    • Influence of mono and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia
    • Ivanoff C.J., Sennerby L., and Lekholm U. Influence of mono and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia. Int J Oral Maxillofac Surg 25 (1996) 229-235
    • (1996) Int J Oral Maxillofac Surg , vol.25 , pp. 229-235
    • Ivanoff, C.J.1    Sennerby, L.2    Lekholm, U.3
  • 7
    • 0014636440 scopus 로고
    • Intraosseous anchorage of dental prostheses. I. Experimental studies
    • Branemark P.I., Breine U., and Adell R. Intraosseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 3 (1969) 81-100
    • (1969) Scand J Plast Reconstr Surg , vol.3 , pp. 81-100
    • Branemark, P.I.1    Breine, U.2    Adell, R.3
  • 8
    • 0032150708 scopus 로고    scopus 로고
    • Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature
    • Sennerby L., and Roos J. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont 11 (1998) 408-420
    • (1998) Int J Prosthodont , vol.11 , pp. 408-420
    • Sennerby, L.1    Roos, J.2
  • 11
    • 0035022398 scopus 로고    scopus 로고
    • Analysis of the osseous/metal interface of drill free screws and self-tapping screws
    • Heidemann W., Terheyden H., and Gerlach K.L. Analysis of the osseous/metal interface of drill free screws and self-tapping screws. J Craniomaxillofac Surg 29 (2001) 69-74
    • (2001) J Craniomaxillofac Surg , vol.29 , pp. 69-74
    • Heidemann, W.1    Terheyden, H.2    Gerlach, K.L.3
  • 12
    • 0025333345 scopus 로고
    • Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site
    • Roberts W.E., Marshall K.J., and Mozsary P.G. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod 60 (1990) 135-152
    • (1990) Angle Orthod , vol.60 , pp. 135-152
    • Roberts, W.E.1    Marshall, K.J.2    Mozsary, P.G.3
  • 14
    • 3042636260 scopus 로고    scopus 로고
    • A rational approach to orthodontic anchorage
    • Melsen B., and Verna C. A rational approach to orthodontic anchorage. Prog Orthod 1 (1999) 10-22
    • (1999) Prog Orthod , vol.1 , pp. 10-22
    • Melsen, B.1    Verna, C.2
  • 15
    • 23344442786 scopus 로고    scopus 로고
    • Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage
    • Kim J.W., Ahn S.J., and Chang Y.I. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop 128 (2005) 190-194
    • (2005) Am J Orthod Dentofacial Orthop , vol.128 , pp. 190-194
    • Kim, J.W.1    Ahn, S.J.2    Chang, Y.I.3
  • 17
    • 0033142077 scopus 로고    scopus 로고
    • Bone response to orthodontic loading of endosseous implants in the rabbit calvaria:early continuous distalizing force
    • Majzoub Z., Finotti M., Miotti F., Giardino R., Aldini N.N., and Cordioli G. Bone response to orthodontic loading of endosseous implants in the rabbit calvaria:early continuous distalizing force. Eur J Orthod 21 (1999) 223-230
    • (1999) Eur J Orthod , vol.21 , pp. 223-230
    • Majzoub, Z.1    Finotti, M.2    Miotti, F.3    Giardino, R.4    Aldini, N.N.5    Cordioli, G.6
  • 18
    • 0036484697 scopus 로고    scopus 로고
    • Progressive bone adaptation of titanium implants during and after orthodontic load in humans
    • Trisi P., and Rebaudi A. Progressive bone adaptation of titanium implants during and after orthodontic load in humans. Int J Periodont Res Dent 22 (2002) 31-43
    • (2002) Int J Periodont Res Dent , vol.22 , pp. 31-43
    • Trisi, P.1    Rebaudi, A.2
  • 19
    • 13244279612 scopus 로고    scopus 로고
    • Ecacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine
    • Yazu M., Kin A., Kosaka R., et al. Ecacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine. J Orthop Sci 10 (2005) 56-61
    • (2005) J Orthop Sci , vol.10 , pp. 56-61
    • Yazu, M.1    Kin, A.2    Kosaka, R.3
  • 20
    • 3042742564 scopus 로고    scopus 로고
    • Augmentation of pedicle screw. Fixation strength using an injectable calcium phosphate cement as a function of injection timing and method
    • Renner S.M., Lim T.H., Kim W.J., et al. Augmentation of pedicle screw. Fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine 29 (2004) E212-E216
    • (2004) Spine , vol.29
    • Renner, S.M.1    Lim, T.H.2    Kim, W.J.3
  • 21
    • 0344242069 scopus 로고    scopus 로고
    • Histomorphological study on pattern of fluid movement in cortical bone in goats
    • Qin L., Mak A.T., Cheng C.W., Hung L.K., and Chan K.M. Histomorphological study on pattern of fluid movement in cortical bone in goats. Anat Rec 255 (1999) 380-387
    • (1999) Anat Rec , vol.255 , pp. 380-387
    • Qin, L.1    Mak, A.T.2    Cheng, C.W.3    Hung, L.K.4    Chan, K.M.5
  • 22
    • 0034764376 scopus 로고    scopus 로고
    • Staining intensity of individual osteons correlated with elastic properties and degrees of mineralization
    • Qin L., Hung L., Leung K., Guo X., Bumrerraj S., and Katz L. Staining intensity of individual osteons correlated with elastic properties and degrees of mineralization. J Bone Miner Metab 19 (2001) 359-364
    • (2001) J Bone Miner Metab , vol.19 , pp. 359-364
    • Qin, L.1    Hung, L.2    Leung, K.3    Guo, X.4    Bumrerraj, S.5    Katz, L.6
  • 23
    • 33244496018 scopus 로고    scopus 로고
    • Low intensity pulsed ultrasound increases the matrix hardness of the healing tissues at bone-tendon insertion: a partial patellectomy model in rabbits
    • Qin L., Fok P.K., Lu H.B., Shi S.Q., Yang L., and Leung K.S. Low intensity pulsed ultrasound increases the matrix hardness of the healing tissues at bone-tendon insertion: a partial patellectomy model in rabbits. Clin Biomech 21 (2006) 387-394
    • (2006) Clin Biomech , vol.21 , pp. 387-394
    • Qin, L.1    Fok, P.K.2    Lu, H.B.3    Shi, S.Q.4    Yang, L.5    Leung, K.S.6
  • 24
    • 0346342539 scopus 로고
    • Histomorphometry applied to model of bone healing
    • Takahashi H. (Ed), Smith Gordon, Niigata
    • Guglielmotti M.B., Ubios A.M., and Cabrini R.L. Histomorphometry applied to model of bone healing. In: Takahashi H. (Ed). Bone morphometry (1990), Smith Gordon, Niigata 492
    • (1990) Bone morphometry , pp. 492
    • Guglielmotti, M.B.1    Ubios, A.M.2    Cabrini, R.L.3
  • 25
    • 0026285722 scopus 로고
    • Relationship between insertion torque and removal torque analyzed in fresh temporal bone
    • Ueda M., Matsuki M., Jacobsson M., and Tjellstrom A. Relationship between insertion torque and removal torque analyzed in fresh temporal bone. Int J Oral Maxillofac Implants 6 (1991) 442-447
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 442-447
    • Ueda, M.1    Matsuki, M.2    Jacobsson, M.3    Tjellstrom, A.4
  • 26
    • 0025900565 scopus 로고
    • Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs
    • Buser D., Schenk R.K., Steinemann S., Fiorellini J.P., Fox C.H., and Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 25 (1991) 889-902
    • (1991) J Biomed Mater Res , vol.25 , pp. 889-902
    • Buser, D.1    Schenk, R.K.2    Steinemann, S.3    Fiorellini, J.P.4    Fox, C.H.5    Stich, H.6
  • 27
    • 0019414459 scopus 로고
    • The reaction of bone, connective tissue and epithelium to endosteal implants with sprayed titanium surfaces
    • Schroeder A., van der Zypen E., Stich H., and Sutter F. The reaction of bone, connective tissue and epithelium to endosteal implants with sprayed titanium surfaces. J Maxillofac Surg 9 (1981) 15-25
    • (1981) J Maxillofac Surg , vol.9 , pp. 15-25
    • Schroeder, A.1    van der Zypen, E.2    Stich, H.3    Sutter, F.4
  • 28
    • 0024198247 scopus 로고
    • Bone tissue interface
    • Roberts E. Bone tissue interface. J Dent Educ 52 (1988) 804-809
    • (1988) J Dent Educ , vol.52 , pp. 804-809
    • Roberts, E.1
  • 29
    • 0024518642 scopus 로고
    • Interface between bone tissue and implants of solid hydroxyapatite or hydroxyapatite-coated titanium implants
    • De Lange G.L., and Donath K. Interface between bone tissue and implants of solid hydroxyapatite or hydroxyapatite-coated titanium implants. Biomaterials 10 (1989) 121-125
    • (1989) Biomaterials , vol.10 , pp. 121-125
    • De Lange, G.L.1    Donath, K.2
  • 30
    • 0032733986 scopus 로고    scopus 로고
    • Clinical applications of drill free screws in maxillofacial surgery
    • Heidemann W., and Gerlach K.L. Clinical applications of drill free screws in maxillofacial surgery. J Craniomaxillofac Surg 27 (1999) 252-255
    • (1999) J Craniomaxillofac Surg , vol.27 , pp. 252-255
    • Heidemann, W.1    Gerlach, K.L.2
  • 31
    • 53249145990 scopus 로고    scopus 로고
    • The effects of varying pilot hole size on the holding power of miniscrews and microscrews
    • Gantous A., and Phillips J.H. The effects of varying pilot hole size on the holding power of miniscrews and microscrews. Plast Reconstr Surg 26 (1998) 50-55
    • (1998) Plast Reconstr Surg , vol.26 , pp. 50-55
    • Gantous, A.1    Phillips, J.H.2
  • 32
    • 1542598950 scopus 로고    scopus 로고
    • Bone histomorphometry study on lumbar vertebrae microstructure of ovariectomized goats
    • He Y., Sun X.C., Chen H.Q., Weng L.L., Zheng H., and Qiu M.C. Bone histomorphometry study on lumbar vertebrae microstructure of ovariectomized goats. Chin J Orthop 38 (2003) 405-408
    • (2003) Chin J Orthop , vol.38 , pp. 405-408
    • He, Y.1    Sun, X.C.2    Chen, H.Q.3    Weng, L.L.4    Zheng, H.5    Qiu, M.C.6
  • 33
  • 34
    • 0030873579 scopus 로고    scopus 로고
    • Pullout strengths of cannulated and noncannulated cancellous bone screws
    • Thompson J.D., Benjamin J.B., and Szivek J.A. Pullout strengths of cannulated and noncannulated cancellous bone screws. Clin Orthop Rel Res 341 (1997) 241-249
    • (1997) Clin Orthop Rel Res , vol.341 , pp. 241-249
    • Thompson, J.D.1    Benjamin, J.B.2    Szivek, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.