메뉴 건너뛰기




Volumn 100 B, Issue 5, 2012, Pages 1444-1450

Biocompatibility of polymethylmethacrylate resins used in dentistry

Author keywords

Biocompatible; Cytotoxic; Dentistry; Leaching; Polymethylmethacrylate

Indexed keywords

BIOCOMPATIBLE; CELL-BASED; CLINICAL EFFECTS; CYTOTOXIC; CYTOTOXIC EFFECTS; HOST RESPONSE; IN-VITRO; ORTHODONTIC APPLIANCES; PMMA RESINS; RESIDUAL MONOMERS; TISSUE COMPATIBILITY; TOXIC SUBSTANCES;

EID: 84862803078     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.32673     Document Type: Review
Times cited : (164)

References (84)
  • 1
    • 77949491373 scopus 로고    scopus 로고
    • Loss of residual monomer from resilient lining materials processed by different methods
    • León BL, Del Bel Cury AA, Rodrigues Garcia RC. Loss of residual monomer from resilient lining materials processed by different methods. Rev Odonto Cienc 2008;23:215-219.
    • (2008) Rev Odonto Cienc , vol.23 , pp. 215-219
    • León, B.L.1    Del Bel Cury, A.A.2    Rodrigues Garcia, R.C.3
  • 2
    • 31544469514 scopus 로고    scopus 로고
    • Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins
    • DOI 10.1002/jbm.b.30377
    • Bayraktar G, Guvener B, Bural C, Uresin Y. Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins. J Biomed Mater Res B: Appl Biomater 2006;76:340-345. (Pubitemid 43165392)
    • (2006) Journal of Biomedical Materials Research - Part B Applied Biomaterials , vol.76 , Issue.2 , pp. 340-345
    • Bayraktar, G.1    Guvener, B.2    Bural, C.3    Uresin, Y.4
  • 3
    • 63349109080 scopus 로고    scopus 로고
    • Effect of water-bath post-polymerization on the mechanical properties, degree of conversion, and leaching of residual compounds of hard chairside reline resins
    • Urban VM, Machado AL, Vergani CE, Giampaolo ET, Pavarina AC, Almeida FG, Cass QB. Effect of water-bath post-polymerization on the mechanical properties, degree of conversion, and leaching of residual compounds of hard chairside reline resins. Dent Mater 2009;25:662-671.
    • (2009) Dent Mater , vol.25 , pp. 662-671
    • Urban, V.M.1    Machado, A.L.2    Vergani, C.E.3    Giampaolo, E.T.4    Pavarina, A.C.5    Almeida, F.G.6    Cass, Q.B.7
  • 4
    • 33644798720 scopus 로고    scopus 로고
    • Dental polymers
    • Anusavice KJ, editor. 11th ed., St. Louis, MO: Elsevier
    • Rawls H. Dental polymers. In: Anusavice KJ, editor. Phillips' Science of Dental Materials, 11th ed., Vol. 7. St. Louis, MO: Elsevier; 2003; pp 143-169.
    • (2003) Phillips' Science of Dental Materials , vol.7 , pp. 143-169
    • Rawls, H.1
  • 5
    • 16344372482 scopus 로고    scopus 로고
    • Prosthetic applications of polymers
    • Craig R, Powers JM, Powers J, editors. 11th ed. (Chapter 21). St. Louis, MO: Mosby
    • Koran III. Prosthetic applications of polymers. In: Craig R, Powers JM, Powers J, editors. Restorative Dental Materials, 11th ed. (Chapter 21). St. Louis, MO: Mosby; 2002. pp 635-681.
    • (2002) Restorative Dental Materials , pp. 635-681
    • Koran, I.I.I.1
  • 8
    • 42149110357 scopus 로고    scopus 로고
    • Effect of polymerization methods on the residual monomer level of acrylic resin denture base polymers
    • DOI 10.1002/pat.996
    • Celebi N, Yuzugullu B, Canay S, Yucel U. Effect of polymerization methods on the residual monomer level of acrylic resin denture base polymers. Polym Adv Technol 2008;19:201-206. (Pubitemid 351523537)
    • (2008) Polymers for Advanced Technologies , vol.19 , Issue.3 , pp. 201-206
    • Celebi, N.1    Yuzugulu, B.2    Canay, S.3    Yucel, U.4
  • 9
    • 0024064625 scopus 로고
    • Some aspects of the chemistry and physics of dental resins
    • Braden M. Some aspects of the chemistry and physics of dental resins. Adv Dent Res 1988;2:93-97.
    • (1988) Adv Dent Res , vol.2 , pp. 93-97
    • Braden, M.1
  • 11
    • 0022793894 scopus 로고
    • A new visible light-cured resin system applied to removable prosthodontics
    • Ogle RE, Sorensen SE, Lewis EA. A new visible light-cured resin system applied to removable prosthodontics. J Prosthet Dent 1986;56:497-506.
    • (1986) J Prosthet Dent , vol.56 , pp. 497-506
    • Ogle, R.E.1    Sorensen, S.E.2    Lewis, E.A.3
  • 12
    • 0020583339 scopus 로고
    • The level of residual monomer in self-curing denture-base materials
    • Fletcher AM, Purnaveja S, Amin WM, Ritchie GM, Moradians S, Dodd AW. The level of residual monomer in self curing denture-base materials. J Dent Res 1983;62:118-120. (Pubitemid 13081989)
    • (1983) Journal of Dental Research , vol.62 , Issue.2 , pp. 118-120
    • Fletcher, A.M.1    Purnaveja, S.2    Amin, W.M.3
  • 13
    • 0033089167 scopus 로고    scopus 로고
    • Release of methyl methacrylate from heat-cured and autopolymerized resins: Cytotoxicity testing related to residual monomer
    • Kedjarune U, Charoenworaluk N, Koontongkaew S. Release of methyl methacrylate from heat-cured and autopolymerized resins: Cytotoxicity testing related to residual monomer. Aust Dent J 1999;44:25-30.
    • (1999) Aust Dent J , vol.44 , pp. 25-30
    • Kedjarune, U.1    Charoenworaluk, N.2    Koontongkaew, S.3
  • 14
    • 0027016256 scopus 로고
    • Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers
    • Harrison A, Huggett R. Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers. J Dent 1992;20:370-374.
    • (1992) J Dent , vol.20 , pp. 370-374
    • Harrison, A.1    Huggett, R.2
  • 15
    • 0031989291 scopus 로고    scopus 로고
    • Effect of polymerization temperature and time on the residual monomer content of denture base polymers
    • Vallittu PK, Ruyter IE, Buykuilmaz S. Effect of polymerization temperature and time on the residual monomer content of denture base polymers. Eur J Oral Sci 1998;106:588-593. (Pubitemid 128736232)
    • (1998) European Journal of Oral Sciences , vol.106 , Issue.1 , pp. 588-593
    • Vallittu, P.K.1    Ruyter, I.E.2    Buykuilmaz, S.3
  • 16
    • 0027650798 scopus 로고
    • Flow injection analysis of formaldehyde leached from denture-base acrylic resins
    • Tsuchiya H, Hoshino Y, Kato H, Takagi N. Flow injection analysis of formaldehyde leached from denture-base acrylic resins. J Dent 1993;21:240-243.
    • (1993) J Dent , vol.21 , pp. 240-243
    • Tsuchiya, H.1    Hoshino, Y.2    Kato, H.3    Takagi, N.4
  • 17
    • 0028452549 scopus 로고
    • Leaching and cytotoxicity of formaldehyde and methyl methacrylate from acrylic resin denture base materials
    • Tsuchiya H, Hoshino Y, Tajima K, Takagi N. Leaching and cytotoxicity of formaldehyde and methyl methacrylate from acrylic resin denture base materials. J Prosthet Dent 1994;71:618-624.
    • (1994) J Prosthet Dent , vol.71 , pp. 618-624
    • Tsuchiya, H.1    Hoshino, Y.2    Tajima, K.3    Takagi, N.4
  • 18
    • 0034132968 scopus 로고    scopus 로고
    • Patterns of cell death induced by elutes from denture base acrylic resins in U-937 human monoblastoid cells
    • Cimpan MR, Cressey LI, Skaug N, Halstensen A, Lie SA, Gjertsen BT. Patterns of cell death induced by elutes from denture base acrylic resins in U-937 human monoblastoid cells. Eur J Oral Sci 2000;108:59-69.
    • (2000) Eur J Oral Sci , vol.108 , pp. 59-69
    • Cimpan, M.R.1    Cressey, L.I.2    Skaug, N.3    Halstensen, A.4    Lie, S.A.5    Gjertsen, B.T.6
  • 19
    • 0034297007 scopus 로고    scopus 로고
    • The effect of heat- And auto-polymerized denture base polymers on clonogenicity, apoptosis, and necrosis in fibroblasts: Denture base polymers induce apoptosis and necrosis
    • Cimpan MR, Matre R, Cressey LI, Tysnes B, Lie SA, Gjertsen BT. The effect of heat- and auto-polymerized denture base polymers on clonogenicity, apoptosis, and necrosis in fibroblasts: denture base polymers induce apoptosis and necrosis. Acta Odontol Scand 2000;58:217-228.
    • (2000) Acta Odontol Scand , vol.58 , pp. 217-228
    • Cimpan, M.R.1    Matre, R.2    Cressey, L.I.3    Tysnes, B.4    Lie, S.A.5    Gjertsen, B.T.6
  • 20
    • 0028541412 scopus 로고
    • Effect of microwave irradiation on the flexural strength and residual monomer levels of an acrylic resin repair material
    • Yunus N, Harrison A, Huggett R. Effect of microwave irradiation on the flexural strength and residual monomer levels of an acrylic resin repair material. J Oral Rehabil 1994;21:641-648.
    • (1994) J Oral Rehabil , vol.21 , pp. 641-648
    • Yunus, N.1    Harrison, A.2    Huggett, R.3
  • 21
    • 0033210431 scopus 로고    scopus 로고
    • Microwave polymerization of denture base materials. A comparative study
    • Blagojevic V, Murphy VM. Microwave polymerization of denture base materials. A comparative study. J Oral Rehabil 1999;26:804-808.
    • (1999) J Oral Rehabil , vol.26 , pp. 804-808
    • Blagojevic, V.1    Murphy, V.M.2
  • 22
    • 0023334837 scopus 로고
    • Microwave polymerization of acrylic resins used in dental prostheses
    • De Clerck JP. Microwave polymerization of acrylic resins used in dental prostheses. J Prosthet Dent 1987;57:650-658.
    • (1987) J Prosthet Dent , vol.57 , pp. 650-658
    • De Clerck, J.P.1
  • 23
    • 0019328321 scopus 로고
    • The level of residual monomer in acrylic denture base materials with particular reference to a modified method of analysis
    • Austin AT, Basker RM. The level of residual monomer in acrylic denture base materials with particular reference to a modified method of analysis. Br Dent J 1980;149:281-286.
    • (1980) Br Dent J , vol.149 , pp. 281-286
    • Austin, A.T.1    Basker, R.M.2
  • 24
    • 0024094569 scopus 로고
    • The release of residual monomeric methyl methacrylate from acrylic appliances in human mouth: An assay for monomer in saliva
    • Baker S, Brooks SC, Walker DM. The release of residual monomeric methyl methacrylate from acrylic appliances in human mouth: An assay for monomer in saliva. J Dent Res 1988;67:1295-1299.
    • (1988) J Dent Res , vol.67 , pp. 1295-1299
    • Baker, S.1    Brooks, S.C.2    Walker, D.M.3
  • 25
    • 17444377489 scopus 로고    scopus 로고
    • HPLC determination of residual monomers released from heat-cured acrylic resins
    • DOI 10.1007/s00216-005-3059-x
    • Sofou A, Tsoupi I, Emmanouil J, Karayannis M. HPLC determination of residual monomers released from heat-cured acrylic resins. Anal Bioanal Chem 2005;381:1336-1346. (Pubitemid 40537604)
    • (2005) Analytical and Bioanalytical Chemistry , vol.381 , Issue.7 , pp. 1336-1346
    • Sofou, A.1    Tsoupi, I.2    Emmanouil, J.3    Karayannis, M.4
  • 28
    • 58149325875 scopus 로고
    • Residual monomer content and its release into water from denture base materials
    • Vallittu PK, Miettinen V, Alakuijala P. Residual monomer content and its release into water from denture base materials. Dent Mater 1995;11:338-342.
    • (1995) Dent Mater , vol.11 , pp. 338-342
    • Vallittu, P.K.1    Miettinen, V.2    Alakuijala, P.3
  • 29
    • 0030157721 scopus 로고    scopus 로고
    • The effect of surface treatment of denture acrylic resin on the residual monomer content and its release into water
    • Vallittu PK. The effect of surface treatment of denture acrylic resin on the residual monomer content and its release into water. Acta Odontol Scand 1996;54:188-192. (Pubitemid 126507387)
    • (1996) Acta Odontologica Scandinavica , vol.54 , Issue.3 , pp. 188-192
    • Vallittu, P.K.1
  • 30
    • 0043071605 scopus 로고    scopus 로고
    • Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerised
    • DOI 10.1016/S0300-5712(03)00090-3
    • Azzarri MJ, Cortizo MS, Alessandrini JL. Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerized. J Dent 2003;31:463-468. (Pubitemid 36961435)
    • (2003) Journal of Dentistry , vol.31 , Issue.7 , pp. 463-468
    • Azzarri, M.J.1    Cortizo, M.S.2    Alessandrini, J.L.3
  • 32
    • 0022109903 scopus 로고
    • The loss of residual monomer from acrylic orthodontic resins
    • Stafford GD, Brooks SC. The loss of residual monomer from acrylic orthodontic resins. Dent Mater 1985;1:135-138.
    • (1985) Dent Mater , vol.1 , pp. 135-138
    • Stafford, G.D.1    Brooks, S.C.2
  • 33
    • 0141463996 scopus 로고    scopus 로고
    • Reducing the negative effects of chemical polishing in acrylic resins by use of an additional cycle of polymerization
    • DOI 10.1016/S0022-3913(03)00169-0
    • Nunes de Mello JA, Braun KO, Rached RN, Del Bel Cury AA. Reducing the negative effects of chemical polishing in acrylic resins by use of an additional cycle of polymerization. J Prosthet Dent 2003;89:598-602. (Pubitemid 37304940)
    • (2003) Journal of Prosthetic Dentistry , vol.89 , Issue.6 , pp. 598-602
    • Nunes, D.M.J.A.1    Olmedo, B.K.2    Nunes, R.R.3    Del, B.C.A.A.4
  • 34
    • 0026160564 scopus 로고
    • An in vivo and in vitro study of the loss of plasticizer from soft polymer-gel materials
    • Graham BS, Jones DW, Suttow EJ. An in vivo and in vitro study of the loss of plasticizer from soft polymer-gel materials. J Dent Res 1991;70:870-873.
    • (1991) J Dent Res , vol.70 , pp. 870-873
    • Graham, B.S.1    Jones, D.W.2    Suttow, E.J.3
  • 35
  • 36
    • 1842526593 scopus 로고    scopus 로고
    • Leachability of plasticizer and residual monomer from commercial temporary restorative resins
    • DOI 10.1016/j.jdent.2003.12.004, PII S0300571203002197
    • Kawahara T, Nomura Y, Tanaka N, Teshima W, Okazaki M, Shintani M. Leachability of plasticizer and residual monomer from commercial temporary restorative resins. J Dent 2004;32:277-283. (Pubitemid 38438437)
    • (2004) Journal of Dentistry , vol.32 , Issue.4 , pp. 277-283
    • Kawahara, T.1    Nomura, Y.2    Tanaka, N.3    Teshima, W.4    Okazaki, M.5    Shintani, H.6
  • 37
    • 0030078022 scopus 로고    scopus 로고
    • Effect of light-exposure duration on the amount of leachable monomers from light-activated reline material
    • Kawaguchi M, Takahashi Y, Fukushima T, Habu T. Effect of light-exposure duration on the amount of leachable monomers from light-activated reline material. J Prosthet Dent 1996;75:183-187. (Pubitemid 126653660)
    • (1996) Journal of Prosthetic Dentistry , vol.75 , Issue.2 , pp. 183-187
    • Kawaguchi, M.1    Takahashi, Y.2    Fukushima, T.3    Habu, T.4
  • 38
    • 54049143632 scopus 로고    scopus 로고
    • Release of dibenzoyl peroxide from polymethyl methacrylate denture base resins: An in vitro evaluation
    • Boeckler AF, Morton D, Poser S, Dette KE. Release of dibenzoyl peroxide from polymethyl methacrylate denture base resins: An in vitro evaluation. Dent Mater 2008;24:1602-1607.
    • (2008) Dent Mater , vol.24 , pp. 1602-1607
    • Boeckler, A.F.1    Morton, D.2    Poser, S.3    Dette, K.E.4
  • 39
    • 17844385041 scopus 로고    scopus 로고
    • Plasticizers in denture soft-lining materials: Leaching and biodegradation
    • DOI 10.1111/j.1600-0722.2005.00204.x
    • Munksgaard EC. Plasticizers in denture soft-lining materials: leaching and biodegradation. Eur J Oral Sci 2005;113:166-169. (Pubitemid 40592284)
    • (2005) European Journal of Oral Sciences , vol.113 , Issue.2 , pp. 166-169
    • Munksgaard, E.C.1
  • 41
    • 44849122236 scopus 로고    scopus 로고
    • The influence of denture cleansers on the release of organic compounds from soft lining materials
    • DOI 10.1039/b719825f
    • Brozek R, Rogalewicz R, Koczorowski R, Voelkel A. The influence of denture cleansers on the release of organic compounds from soft lining materials. J Environ Monit 2008;10:770-774. (Pubitemid 351798442)
    • (2008) Journal of Environmental Monitoring , vol.10 , Issue.6 , pp. 770-774
    • Brozek, R.1    Rogalewicz, R.2    Koczorowski, R.3    Voelkel, A.4
  • 42
    • 0021519067 scopus 로고
    • Long-term biocompatibility test of denture base resins in vitro
    • Nakamura M, Kawahara H. Long-term biocompatibility test of denture base resins in vitro. J Prosthet Dent 1984;52:694-699.
    • (1984) J Prosthet Dent , vol.52 , pp. 694-699
    • Nakamura, M.1    Kawahara, H.2
  • 44
    • 9744232252 scopus 로고    scopus 로고
    • Cytotoxic effects of dental resin liquids on primary gingival fibroblasts and periodontal ligament cells in vitro
    • Lai YL, Chen YT, Lee SY, Shieh TM, Hung SL. Cytotoxic effects of dental resin liquids on primary gingival fibroblasts and periodontal ligament cells in vitro. J Oral Rehabil 2004;31:1165-1172.
    • (2004) J Oral Rehabil , vol.31 , pp. 1165-1172
    • Lai, Y.L.1    Chen, Y.T.2    Lee, S.Y.3    Shieh, T.M.4    Hung, S.L.5
  • 46
    • 0008483538 scopus 로고    scopus 로고
    • Acrylic bone cement induces the production of free radicals by cultured human fibroblasts
    • DOI 10.1016/S0142-9612(97)00043-4, PII S0142961297000434
    • Vale FM, Castro M, Monteiro J, Couto FS, Pinto R, Toscano Rico JMG. Acrylic bone cement induces the production of free radicals by cultured human fibroblasts. Biomaterials 1997;18:1133-1135. (Pubitemid 27342990)
    • (1997) Biomaterials , vol.18 , Issue.16 , pp. 1133-1135
    • Vale, F.M.1    Castro, M.2    Monteiro, J.3    Couto, F.S.4    Pinto, R.5    Rico, J.M.G.T.6
  • 49
    • 0028800403 scopus 로고
    • In vivo assessment of methyl methacrylate metabolism and toxicity
    • Bereznowski Z. In vivo assessment of methyl methacrylate metabolism and toxicity. Int J Biochem Cell Biol 1995;27:1311-1316.
    • (1995) Int J Biochem Cell Biol , vol.27 , pp. 1311-1316
    • Bereznowski, Z.1
  • 51
    • 84862781015 scopus 로고    scopus 로고
    • Technische Regel fur Gefahrstoffe: TRGS 900 - Grenzwerte in der Luft am Arbeitsplatz - Luftgrenzwerte
    • 10/ eingearbeitete Anderungen: 4/2001 p 56; 9/2001 p 86
    • Technische Regel fur Gefahrstoffe: TRGS 900 - Grenzwerte in der Luft am Arbeitsplatz - Luftgrenzwerte. [Technical regulations for hazardous substances: TRGS 900 - Threshold values in air at the work place - threshold values for air] BarbBl. 10/2000 pp 34-63; eingearbeitete Anderungen: 4/2001 p 56; 9/2001 p 86.
    • (2000) BarbBl , pp. 34-63
  • 52
    • 0026036749 scopus 로고
    • Perceived side effects of biomaterials in prosthetic dentistry
    • Hensten-Pettersen A, Jacobsen N. Perceived side effects of biomaterials in prosthetic dentistry. J Prosthet Dent 1991;65:138-144.
    • (1991) J Prosthet Dent , vol.65 , pp. 138-144
    • Hensten-Pettersen, A.1    Jacobsen, N.2
  • 54
    • 0035892408 scopus 로고    scopus 로고
    • Osteoblast cell death on methacrylate polymers involves apoptosis
    • DOI 10.1002/1097-4636(20011215)57:4<497::AID-JBM1195>3.0.CO;2-U
    • Gough JE, Downes S. Osteoblast cell death on methacrylate polymers involves apoptosis. J Biomed Mater Res 2001;57:497-505. (Pubitemid 32937530)
    • (2001) Journal of Biomedical Materials Research , vol.57 , Issue.4 , pp. 497-505
    • Gough, J.E.1    Downes, S.2
  • 55
    • 0032487113 scopus 로고    scopus 로고
    • Cytotoxicity of 35 dental resin composite monomers/additives in permanent 3T3 and three human primary fibroblast cultures
    • DOI 10.1002/(SICI)1097-4636(19980905)41:3<474::AID-JBM18>3.0.CO;2-I
    • Geurtsen W, Lehmann F, Spahl W, Leyhausen G. Cytotoxicity of 35 dental resin composite monomers/additives in permanent 3T3 and three human primary fibroblast cultures. J Biomed Mater Res 1998;41:474-480. (Pubitemid 28300113)
    • (1998) Journal of Biomedical Materials Research , vol.41 , Issue.3 , pp. 474-480
    • Geurtsen, W.1    Lehmann, F.2    Spahl, W.3    Leyhausen, G.4
  • 56
    • 0031081433 scopus 로고    scopus 로고
    • High-performance liquid chromatography assay of N,N-dimethyl-p-toluidine released from bone cements: Evidence for toxicity
    • DOI 10.1016/S0142-9612(96)00121-4, PII S0142961296001214
    • Stea S, Granchi D, Zolezzi C, Ciapetti G, Visentin M, Cavedagna D, Pizzoferrato A. High-performance liquid chromatography assay of N,N-dimethyl-p-toluidine released from bone cements: evidence for toxicity. Biomaterials 1997;18:243-246. (Pubitemid 27064799)
    • (1997) Biomaterials , vol.18 , Issue.3 , pp. 243-246
    • Stea, S.1    Granchi, D.2    Zolezzi, C.3    Ciapetti, G.4    Visentin, M.5    Cavedagna, D.6    Pizzoferrato, A.7
  • 57
    • 0347372608 scopus 로고    scopus 로고
    • Microleakage study of various soft denture liners by autoradiography: Effect of accelerated aging
    • Anil N, Hekimoglu C, Buyukba N, Ercan MT. Microleakage study of various soft denture liners by autoradiography: Effect of accelerated aging. J Prosthet Dent 2000;81:394-399.
    • (2000) J Prosthet Dent , vol.81 , pp. 394-399
    • Anil, N.1    Hekimoglu, C.2    Buyukba, N.3    Ercan, M.T.4
  • 58
    • 0017707727 scopus 로고
    • Mycotic growth and soft denture lining materials
    • Makila E, Hopsu-Havu VK. Mycotic growth and soft denture lining materials. Acta Odont Scand 1976;35:197-205. (Pubitemid 8178984)
    • (1977) Acta Odontologica Scandinavica , vol.35 , Issue.4 , pp. 197-205
    • Makila, E.1    Hopsu, H.V.K.2
  • 59
    • 0029400245 scopus 로고
    • Effect of components of resilient denture-lining materials on the growth, acid production and colonization of Candida albicans
    • Nikawa H, Yamamoto T, Hamada T. Effect of components of resilient denture-lining materials on the growth, acid production and colonization of Candida albicans. J Oral Rehabil 1995;22:817-824.
    • (1995) J Oral Rehabil , vol.22 , pp. 817-824
    • Nikawa, H.1    Yamamoto, T.2    Hamada, T.3
  • 60
    • 0031205563 scopus 로고    scopus 로고
    • Effects of salivary or serum pellicles on the Candida albicans growth and biofilm formation on soft lining materials in vitro
    • Nikawa H, Hamada T, Yamamoto T, Kumagai H. Effects of salivary or serum pellicles on the Candida albicans growth and biofilm formation on soft lining materials in vitro. J Oral Rehabil 1997;24:594-604. (Pubitemid 127731965)
    • (1997) Journal of Oral Rehabilitation , vol.24 , Issue.8 , pp. 594-604
    • Nikawa, H.1    Hamada, T.2    Yamamoto, T.3    Kumagai, H.4
  • 61
    • 0034570264 scopus 로고    scopus 로고
    • Candida albicans colonization of surface-sealed interim soft liners
    • Olan-Rodriguez L, Minah GE, Driscoll CF. Candida albicans colonization of surface-sealed interim soft liners. J Prosthodont 2000;9:184-188.
    • (2000) J Prosthodont , vol.9 , pp. 184-188
    • Olan-Rodriguez, L.1    Minah, G.E.2    Driscoll, C.F.3
  • 62
    • 0033170814 scopus 로고    scopus 로고
    • The influence of oral bacteria on the surfaces of resin-based dental restorative materials: An in vitro study
    • Willershausen B, Callaway A, Ernst CP, Stender E. The influence of oral bacteria on the surfaces of resin-based dental restorative materials: An in vitro study. Int Dent J 1999;49:231-239.
    • (1999) Int Dent J , vol.49 , pp. 231-239
    • Willershausen, B.1    Callaway, A.2    Ernst, C.P.3    Stender, E.4
  • 64
    • 0025617682 scopus 로고
    • Allergy to dental materials with special reference to the use of amalgam and polymethylmethacrylate
    • Kaaber S. Allergy to dental materials with special reference to the use of amalgam and polymethylmethacrylate. Int Dent J 1990;40:359-365.
    • (1990) Int Dent J , vol.40 , pp. 359-365
    • Kaaber, S.1
  • 65
    • 0023054235 scopus 로고
    • The burning mouth sensation related to the wearing of acrylic dentures: An investigation
    • Ali A, Bates FJ, Reynolds AJ, Walker DM. The burning mouth sensation related to the wearing of acrylic dentures: An investigation. Br Dent J 1986;161:444-447.
    • (1986) Br Dent J , vol.161 , pp. 444-447
    • Ali, A.1    Bates, F.J.2    Reynolds, A.J.3    Walker, D.M.4
  • 66
    • 84989571821 scopus 로고
    • Incidence of adverse effects of dental materials
    • Kallus T, Mjor IA. Incidence of adverse effects of dental materials. Scand J Dent Res 1991;99:236-240.
    • (1991) Scand J Dent Res , vol.99 , pp. 236-240
    • Kallus, T.1    Mjor, I.A.2
  • 67
    • 0024502652 scopus 로고
    • Allergic contact dermatitis from dental composite resins due to aromatic epoxy acrylates and aliphatic acrylates
    • DOI 10.1111/j.1600-0536.1989.tb04657.x
    • Kanerva L, Estlander T, Jolanki R. Allergic contact dermatitis from dental composite resins due to aromatic epoxy acrylates and aliphatic acrylates. Contact Dermat 1989;20:201-211. (Pubitemid 19066590)
    • (1989) Contact Dermatitis , vol.20 , Issue.3 , pp. 201-211
    • Kanerva, L.1    Estlander, T.2    Jolanki, R.3
  • 68
    • 0035229637 scopus 로고    scopus 로고
    • Prevalence of contact dermatitis among dental personnel in a Swedish rural county
    • Ohlson CG, Svensson L, Mossberg B, Hok M. Prevalence of contact dermatitis among dental personnel in a Swedish rural county. Swed Dent J 2001;25:13-20. (Pubitemid 33745399)
    • (2001) Swedish Dental Journal , vol.25 , Issue.1 , pp. 13-20
    • Ohlson, C.-G.1    Svensson, L.2    Mossberg, B.3    Hok, M.4
  • 70
    • 84862824592 scopus 로고    scopus 로고
    • Cytocompatibility of ionomer- And resin-based bone cements
    • Leyhausen G, Kunert M, Bubeck P, Geurtsen W. Cytocompatibility of ionomer- and resin-based bone cements. J Dent Res 1998;77:119-123.
    • (1998) J Dent Res , vol.77 , pp. 119-123
    • Leyhausen, G.1    Kunert, M.2    Bubeck, P.3    Geurtsen, W.4
  • 71
    • 0024502652 scopus 로고
    • Allergic contact dermatitis from dental composite resins due to aromatic epoxy acrylates and aliphatic acrylates
    • DOI 10.1111/j.1600-0536.1989.tb04657.x
    • Kanerva L, Estlander T, Jolanki R. Allergic contact dermatitis from dental composite resins due to aromatic epoxy acrylates and aliphatic acrylates. Contact Dermat 1989;20:201-211. (Pubitemid 19066590)
    • (1989) Contact Dermatitis , vol.20 , Issue.3 , pp. 201-211
    • Kanerva, L.1    Estlander, T.2    Jolanki, R.3
  • 72
    • 0028096529 scopus 로고
    • Occupational skin allergy in the dental profession
    • Kanerva L, Estlander T, Jolanki R. Occupational skin allergy in the dental profession. Dermatol Clin 1994;12:517-532. (Pubitemid 24260334)
    • (1994) Dermatologic Clinics , vol.12 , Issue.3 , pp. 517-532
    • Kanerva, L.1    Estlander, T.2    Jolanki, R.3
  • 73
    • 0017123954 scopus 로고
    • Allergic stomatitis caused by self-polymerizing resin
    • Giunta J, Zablotsky N. Allergic stomatitis caused by self-polymerizing resin. Oral Surg Oral Med Oral Pathol 1976;41:631-637.
    • (1976) Oral Surg Oral Med Oral Pathol , vol.41 , pp. 631-637
    • Giunta, J.1    Zablotsky, N.2
  • 74
    • 0033815734 scopus 로고    scopus 로고
    • Chronic urticaria from an acrylic dental prosthesis
    • Lunder T, Rogl-Butina M. Chronic urticaria from an acrylic dental prosthesis. Contact Dermat 2000;43:232-233.
    • (2000) Contact Dermat , vol.43 , pp. 232-233
    • Lunder, T.1    Rogl-Butina, M.2
  • 75
    • 0141638366 scopus 로고    scopus 로고
    • Toxicity of methylmethacrylate in dentistry
    • Leggat PA, Kedjarune U. Toxicity of methylmethacrylate in dentistry. Int Dent J 2003;53:126-131.
    • (2003) Int Dent J , vol.53 , pp. 126-131
    • Leggat, P.A.1    Kedjarune, U.2
  • 77
    • 35248832090 scopus 로고    scopus 로고
    • Methacrylate and acrylate allergy in dental personnel
    • DOI 10.1111/j.1600-0536.2007.01237.x
    • Aalto-Korte K, Alanko K, Kuuliala O, Jolanki R. Methacrylate and acrylate allergy in dental personnel. Contact Dermat 2007;57:324-330. (Pubitemid 47568794)
    • (2007) Contact Dermatitis , vol.57 , Issue.5 , pp. 324-330
    • Aalto-Korte, K.1    Alanko, K.2    Kuuliala, O.3    Jolanki, R.4
  • 79
    • 0019034953 scopus 로고
    • Biophysical evaluation of the tumorigenic response to implanted polymers
    • Habal MB, Powell RD. Biophysical evaluation of the tumorigenic response to implanted polymers. J Biomed Mat Res 1980;14:447-454. (Pubitemid 10086167)
    • (1980) Journal of Biomedical Materials Research , vol.14 , Issue.4 , pp. 447-454
    • Habal, M.B.1    Powell, R.D.2
  • 81
    • 26444512182 scopus 로고
    • Determining the tumorigenicity of dental materials
    • Mitchell DF, Shankwalker GB, Shazer S. Determining the tumorigenicity of dental materials. J Dent Res 1960;39:1023-1028.
    • (1960) J Dent Res , vol.39 , pp. 1023-1028
    • Mitchell, D.F.1    Shankwalker, G.B.2    Shazer, S.3
  • 82
    • 0016593766 scopus 로고
    • Structure-toxicity relationships of acrylic monomers
    • Autian J. Structure-toxicity relationships of acrylic monomers. Environ Health Perspect 1975;11:141-152.
    • (1975) Environ Health Perspect , vol.11 , pp. 141-152
    • Autian, J.1
  • 83
    • 33646068815 scopus 로고    scopus 로고
    • International Organization for Standardization. 2nd ed. Switzerland: ISO
    • International Organization for Standardization. Specification 1567: Denture Base Polymers, 2nd ed. Switzerland: ISO; 1999.
    • (1999) Specification 1567: Denture Base Polymers
  • 84
    • 56349167502 scopus 로고    scopus 로고
    • N-acetyl cysteine prevents suppression of oral fibroblast function on poly(methylmethacrylate) resin
    • Att W, Yamada M, Kojima N, Ogawa T. N-acetyl cysteine prevents suppression of oral fibroblast function on poly(methylmethacrylate) resin. Acta Biomater 2009;5:391-398.
    • (2009) Acta Biomater , vol.5 , pp. 391-398
    • Att, W.1    Yamada, M.2    Kojima, N.3    Ogawa, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.