메뉴 건너뛰기




Volumn 25, Issue 5, 2009, Pages 662-671

Effect of water-bath post-polymerization on the mechanical properties, degree of conversion, and leaching of residual compounds of hard chairside reline resins

Author keywords

Degree of conversion; Flexural strength; Hard chairside reline resins; Hardness; HPLC; Plasticizer; Post polymerization; Residual monomer

Indexed keywords

BENDING STRENGTH; GELATION; HARDNESS; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; LEACHING; MECHANICAL PROPERTIES; PLASTICIZERS; POLYMERIZATION; POLYMERS; REINFORCED PLASTICS; RESINS; WATER CONTENT;

EID: 63349109080     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2008.10.017     Document Type: Article
Times cited : (67)

References (45)
  • 1
    • 0029181092 scopus 로고
    • Properties of highly cross-linked autopolymerizing reline acrylic resins
    • Arima T., Murata H., and Hamata T. Properties of highly cross-linked autopolymerizing reline acrylic resins. J Prosthet Dent 73 (1995) 55-59
    • (1995) J Prosthet Dent , vol.73 , pp. 55-59
    • Arima, T.1    Murata, H.2    Hamata, T.3
  • 2
    • 1442284169 scopus 로고    scopus 로고
    • A comparison of three hard chairside denture reline materials. Part I. Clinical evaluation
    • Haywood J., Basker R.M., Watson C.J., and Wood D.J. A comparison of three hard chairside denture reline materials. Part I. Clinical evaluation. Eur J Prosthodont Restor Dent 11 (2003) 157-163
    • (2003) Eur J Prosthodont Restor Dent , vol.11 , pp. 157-163
    • Haywood, J.1    Basker, R.M.2    Watson, C.J.3    Wood, D.J.4
  • 4
    • 20444367647 scopus 로고    scopus 로고
    • Flexural strength of autopolymerizing denture reline resins with microwave postpolymerization treatment
    • Vergani C.E., Seo R.S., Pavarina A.C., and Reis J.M.S.N. Flexural strength of autopolymerizing denture reline resins with microwave postpolymerization treatment. J Prosthet Dent 93 (2005) 577-583
    • (2005) J Prosthet Dent , vol.93 , pp. 577-583
    • Vergani, C.E.1    Seo, R.S.2    Pavarina, A.C.3    Reis, J.M.S.N.4
  • 5
    • 33746735585 scopus 로고    scopus 로고
    • Effect of relining, water storage and cyclic loading on the flexural strength of a denture base acrylic resin
    • Reis J.M.S.N., Vergani C.E., Pavarina A.C., and Giampaolo E.T. Effect of relining, water storage and cyclic loading on the flexural strength of a denture base acrylic resin. J Dent 34 (2006) 420-426
    • (2006) J Dent , vol.34 , pp. 420-426
    • Reis, J.M.S.N.1    Vergani, C.E.2    Pavarina, A.C.3    Giampaolo, E.T.4
  • 6
    • 0036550789 scopus 로고    scopus 로고
    • Influence of polymerization conditions on monomer elution and microhardness of autopolymerized polymethyl methacrylate resin
    • Lee S., Lai Y., and Hsu T. Influence of polymerization conditions on monomer elution and microhardness of autopolymerized polymethyl methacrylate resin. Eur J Oral Sci 110 (2002) 179-183
    • (2002) Eur J Oral Sci , vol.110 , pp. 179-183
    • Lee, S.1    Lai, Y.2    Hsu, T.3
  • 7
    • 33846486977 scopus 로고    scopus 로고
    • Residual monomer of reline acrylic resins. Effect of water-bath and microwave post-polymerization treatments
    • Urban V.M., Machado A.L., Oliveira R.V., Vergani C.E., Pavarina A.C., and Cass Q.B. Residual monomer of reline acrylic resins. Effect of water-bath and microwave post-polymerization treatments. Dent Mater 23 (2007) 363-368
    • (2007) Dent Mater , vol.23 , pp. 363-368
    • Urban, V.M.1    Machado, A.L.2    Oliveira, R.V.3    Vergani, C.E.4    Pavarina, A.C.5    Cass, Q.B.6
  • 8
    • 0030157721 scopus 로고    scopus 로고
    • The effect of surface treatment of denture acrylic resin on the residual monomer content and its release into water
    • Vallittu P.K. The effect of surface treatment of denture acrylic resin on the residual monomer content and its release into water. Acta Odontol Scand 54 (1996) 188-192
    • (1996) Acta Odontol Scand , vol.54 , pp. 188-192
    • Vallittu, P.K.1
  • 9
    • 17444377489 scopus 로고    scopus 로고
    • HPLC determination of residual monomers released from heat-cured acrylic resins
    • Sofou A., Tsoupi I., Emmanouil J., and Karayannis M. HPLC determination of residual monomers released from heat-cured acrylic resins. Anal Bioanal Chem 381 (2005) 1336-1346
    • (2005) Anal Bioanal Chem , vol.381 , pp. 1336-1346
    • Sofou, A.1    Tsoupi, I.2    Emmanouil, J.3    Karayannis, M.4
  • 10
    • 0028452549 scopus 로고
    • Leaching and cytotoxicity of formaldehyde and methyl methacrylate from acrylic resin denture base materials
    • Tsuchiya H., Hoshino Y., Tajima K., and Takagi N. Leaching and cytotoxicity of formaldehyde and methyl methacrylate from acrylic resin denture base materials. J Prosthet Dent 71 (1994) 618-624
    • (1994) J Prosthet Dent , vol.71 , pp. 618-624
    • Tsuchiya, H.1    Hoshino, Y.2    Tajima, K.3    Takagi, N.4
  • 11
    • 9744232252 scopus 로고    scopus 로고
    • Cytotoxic effects of dental resin liquids on primary gingival fibroblasts and periodontal ligament cells in vitro
    • Lai Y.L., Chen Y.T., Lee S.Y., Shieh T.M., and Hung S.L. Cytotoxic effects of dental resin liquids on primary gingival fibroblasts and periodontal ligament cells in vitro. J Oral Rehabil 31 (2004) 1165-1172
    • (2004) J Oral Rehabil , vol.31 , pp. 1165-1172
    • Lai, Y.L.1    Chen, Y.T.2    Lee, S.Y.3    Shieh, T.M.4    Hung, S.L.5
  • 12
    • 33645662774 scopus 로고    scopus 로고
    • Cytotoxicity of hard chairside reline resins: effect of microwave irradiation and water-bath post-polymerization treatments
    • Campanha N.H., Pavarina A.C., Giampaolo E.T., Vergani C.E., Machado A.L., and Carlos I.Z. Cytotoxicity of hard chairside reline resins: effect of microwave irradiation and water-bath post-polymerization treatments. Int J Prosthodont 19 (2006) 195-201
    • (2006) Int J Prosthodont , vol.19 , pp. 195-201
    • Campanha, N.H.1    Pavarina, A.C.2    Giampaolo, E.T.3    Vergani, C.E.4    Machado, A.L.5    Carlos, I.Z.6
  • 14
    • 0026036749 scopus 로고
    • Perceived side effects of biomaterials in prosthetic dentistry
    • Hensten-Pettersen A., and Jacobsen N. Perceived side effects of biomaterials in prosthetic dentistry. J Prosthet Dent 65 (1991) 138-144
    • (1991) J Prosthet Dent , vol.65 , pp. 138-144
    • Hensten-Pettersen, A.1    Jacobsen, N.2
  • 15
    • 0030207465 scopus 로고    scopus 로고
    • Traumatic stomatitis following an intraoral denture reline: a clinical report
    • Bohnenkamp D.M. Traumatic stomatitis following an intraoral denture reline: a clinical report. J Prosthet Dent 76 (1996) 113-114
    • (1996) J Prosthet Dent , vol.76 , pp. 113-114
    • Bohnenkamp, D.M.1
  • 17
    • 0033815734 scopus 로고    scopus 로고
    • Chronic urticaria from an acrylic dental prosthesis
    • Lunder T., and Rogl-Butina M. Chronic urticaria from an acrylic dental prosthesis. Contact Dermatitis 43 (2000) 232-233
    • (2000) Contact Dermatitis , vol.43 , pp. 232-233
    • Lunder, T.1    Rogl-Butina, M.2
  • 18
    • 17844385041 scopus 로고    scopus 로고
    • Plasticizers in denture soft-lining materials: leaching and biodegradation
    • Munksgaard E.C. Plasticizers in denture soft-lining materials: leaching and biodegradation. Eur J Oral Sci 113 (2005) 166-169
    • (2005) Eur J Oral Sci , vol.113 , pp. 166-169
    • Munksgaard, E.C.1
  • 19
    • 0030138297 scopus 로고    scopus 로고
    • Analysis of composition and structure of hard autopolymerizing reline resins
    • Arima T., Murata H., and Hamata T. Analysis of composition and structure of hard autopolymerizing reline resins. J Oral Rehabil 23 (1996) 346-352
    • (1996) J Oral Rehabil , vol.23 , pp. 346-352
    • Arima, T.1    Murata, H.2    Hamata, T.3
  • 20
    • 0042736277 scopus 로고    scopus 로고
    • Metabolism of butyl benzyl phthalate by Gordonia sp. strain MTCC 4818
    • Chatterjee S., and Dutta T.K. Metabolism of butyl benzyl phthalate by Gordonia sp. strain MTCC 4818. Biochem Biophys Res Commun 309 (2003) 36-43
    • (2003) Biochem Biophys Res Commun , vol.309 , pp. 36-43
    • Chatterjee, S.1    Dutta, T.K.2
  • 22
    • 0020726857 scopus 로고
    • The effects of process variables on levels of residual monomer in autopolymerizing dental acrylic resin
    • Lamb D.J., Ellis B., and Priestley D. The effects of process variables on levels of residual monomer in autopolymerizing dental acrylic resin. J Dent 11 (1983) 80-88
    • (1983) J Dent , vol.11 , pp. 80-88
    • Lamb, D.J.1    Ellis, B.2    Priestley, D.3
  • 23
    • 0023445630 scopus 로고
    • Objective testing of the efficiency of denture-cleansing agents
    • Minagi S., Tsunoda T., Yoshida K., and Tsuru H. Objective testing of the efficiency of denture-cleansing agents. J Prosthet Dent 58 (1987) 595-598
    • (1987) J Prosthet Dent , vol.58 , pp. 595-598
    • Minagi, S.1    Tsunoda, T.2    Yoshida, K.3    Tsuru, H.4
  • 24
    • 75449149598 scopus 로고
    • Corrosion of gold and amalgam placed in contact with each other
    • Fusayama T., Katayori T., and Nomoto S. Corrosion of gold and amalgam placed in contact with each other. J Dent Res 42 (1963) 1183-1197
    • (1963) J Dent Res , vol.42 , pp. 1183-1197
    • Fusayama, T.1    Katayori, T.2    Nomoto, S.3
  • 25
    • 33749498177 scopus 로고    scopus 로고
    • Linear dimensional changes of denture base and hard chair-side reline resins after disinfection
    • Gonçalves A.R., Machado A.L., Giampaolo E.T., Pavarina A.C., and Vergani C.E. Linear dimensional changes of denture base and hard chair-side reline resins after disinfection. J Appl Polym Sci 102 (2006) 1821-1826
    • (2006) J Appl Polym Sci , vol.102 , pp. 1821-1826
    • Gonçalves, A.R.1    Machado, A.L.2    Giampaolo, E.T.3    Pavarina, A.C.4    Vergani, C.E.5
  • 27
    • 0028476431 scopus 로고
    • Determination of resin cure using infrared analysis without an internal standard
    • Rueggeberg F.A. Determination of resin cure using infrared analysis without an internal standard. Dent Mater 10 (1994) 282-286
    • (1994) Dent Mater , vol.10 , pp. 282-286
    • Rueggeberg, F.A.1
  • 28
    • 0028472254 scopus 로고
    • Elution of leachable components from composites
    • Ferracane J.L. Elution of leachable components from composites. J Oral Rehabil 21 (1994) 441-452
    • (1994) J Oral Rehabil , vol.21 , pp. 441-452
    • Ferracane, J.L.1
  • 30
    • 32044441450 scopus 로고    scopus 로고
    • Hygroscopic and hydrolytic effect in dental polymer networks
    • Ferracane J.L. Hygroscopic and hydrolytic effect in dental polymer networks. Dent Mater 22 (2006) 211-222
    • (2006) Dent Mater , vol.22 , pp. 211-222
    • Ferracane, J.L.1
  • 31
    • 0018856657 scopus 로고
    • Release of formaldehyde from denture base polymers
    • Ruyter I.E. Release of formaldehyde from denture base polymers. Acta Odontol Scand 38 (1980) 17-27
    • (1980) Acta Odontol Scand , vol.38 , pp. 17-27
    • Ruyter, I.E.1
  • 32
    • 0018814882 scopus 로고
    • Flexural properties of denture base polymers
    • Ruyter I.E., and Svendsen S.A. Flexural properties of denture base polymers. J Prosthet Dent 43 (1980) 95-104
    • (1980) J Prosthet Dent , vol.43 , pp. 95-104
    • Ruyter, I.E.1    Svendsen, S.A.2
  • 33
    • 0030184266 scopus 로고    scopus 로고
    • The effects of cross-linking agents on the water sorption and solubility characteristics of denture base resin
    • Arima T., Murata H., and Hamada T. The effects of cross-linking agents on the water sorption and solubility characteristics of denture base resin. J Oral Rehabil 23 (1996) 476-480
    • (1996) J Oral Rehabil , vol.23 , pp. 476-480
    • Arima, T.1    Murata, H.2    Hamada, T.3
  • 35
    • 0033089167 scopus 로고    scopus 로고
    • Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer
    • Kedjarune U., Charoenworaluk N., and Koontongkaew S. Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer. Aust Dent J 44 (1999) 25-30
    • (1999) Aust Dent J , vol.44 , pp. 25-30
    • Kedjarune, U.1    Charoenworaluk, N.2    Koontongkaew, S.3
  • 36
    • 58149325875 scopus 로고
    • Residual monomer content and its release into water from denture base materials
    • Vallittu P.K., Miettinen V., and Alakuijala P. Residual monomer content and its release into water from denture base materials. Dent Mater 11 (1995) 338-342
    • (1995) Dent Mater , vol.11 , pp. 338-342
    • Vallittu, P.K.1    Miettinen, V.2    Alakuijala, P.3
  • 37
    • 0020858730 scopus 로고
    • Acrylate and methacrylate esters: relationship of hemolytic activity and in vivo toxicity
    • Dillingham E.O., Lawrence W.H., Autian J., and Schmalz G. Acrylate and methacrylate esters: relationship of hemolytic activity and in vivo toxicity. J Biomed Mater Res 17 (1983) 945-957
    • (1983) J Biomed Mater Res , vol.17 , pp. 945-957
    • Dillingham, E.O.1    Lawrence, W.H.2    Autian, J.3    Schmalz, G.4
  • 38
    • 0018184406 scopus 로고
    • Studies on hemolytic activity of bisphenol A diglycidyl methacrylate (BIS-GMA)
    • Fujisawa S., Imai Y., Kojima K., and Masuhara E. Studies on hemolytic activity of bisphenol A diglycidyl methacrylate (BIS-GMA). J Dent Res 57 (1978) 98-102
    • (1978) J Dent Res , vol.57 , pp. 98-102
    • Fujisawa, S.1    Imai, Y.2    Kojima, K.3    Masuhara, E.4
  • 39
    • 0034241846 scopus 로고    scopus 로고
    • Cytotoxicity of dental alloys, metals, and ceramics assessed by millipore filter, agar overlay, and MTT tests
    • Sjögren G., Sletten G., and Dahl J.E. Cytotoxicity of dental alloys, metals, and ceramics assessed by millipore filter, agar overlay, and MTT tests. J Prosthet Dent 84 (2000) 229-236
    • (2000) J Prosthet Dent , vol.84 , pp. 229-236
    • Sjögren, G.1    Sletten, G.2    Dahl, J.E.3
  • 40
    • 0026160564 scopus 로고
    • An in vivo and in vitro study of the loss of plasticizer from soft polymer gel materials
    • Graham B.S., Jones D.W., and Sutow E.J. An in vivo and in vitro study of the loss of plasticizer from soft polymer gel materials. J Dent Res 70 (1991) 870-873
    • (1991) J Dent Res , vol.70 , pp. 870-873
    • Graham, B.S.1    Jones, D.W.2    Sutow, E.J.3
  • 41
    • 1842526593 scopus 로고    scopus 로고
    • Leachability of plasticizer and residual monomer from commercial temporary restorative resins
    • Kawahara T., Nomura Y., Tanaka N., Teshima W., Okasaki M., and Shintani H. Leachability of plasticizer and residual monomer from commercial temporary restorative resins. J Dent 32 (2004) 277-283
    • (2004) J Dent , vol.32 , pp. 277-283
    • Kawahara, T.1    Nomura, Y.2    Tanaka, N.3    Teshima, W.4    Okasaki, M.5    Shintani, H.6
  • 42
    • 0030953834 scopus 로고    scopus 로고
    • Reproductive toxicity of di-n-butylphthalate in a continuous breeding protocol in Sprague-Dawley rats
    • Wine R.N., Li L.H., Barnes L.H., Gulati D.K., and Chapin R.E. Reproductive toxicity of di-n-butylphthalate in a continuous breeding protocol in Sprague-Dawley rats. Environ Health Perspect 105 (1997) 102-107
    • (1997) Environ Health Perspect , vol.105 , pp. 102-107
    • Wine, R.N.1    Li, L.H.2    Barnes, L.H.3    Gulati, D.K.4    Chapin, R.E.5
  • 43
    • 63349092668 scopus 로고    scopus 로고
    • Hansen BG, Munn SJ, Allanou R, Berthault F, de Bruijn J, Luotamo M, Musset C, Pakalin S, Pellegrini G, Sheer S, Vegro S (Eds.). European Union Risk Assessment Report. Dibutyl phthalate, CAS no 84-74-2. EINECS no 201-557-4. Luxembourg: Office for Official Publications of the European Communities; 2003 [with addendum 2004].
    • Hansen BG, Munn SJ, Allanou R, Berthault F, de Bruijn J, Luotamo M, Musset C, Pakalin S, Pellegrini G, Sheer S, Vegro S (Eds.). European Union Risk Assessment Report. Dibutyl phthalate, CAS no 84-74-2. EINECS no 201-557-4. Luxembourg: Office for Official Publications of the European Communities; 2003 [with addendum 2004].
  • 44
    • 0031109908 scopus 로고    scopus 로고
    • Static and dynamic moduli of composite restorative materials
    • Jacobsen P.H., and Darr A.H. Static and dynamic moduli of composite restorative materials. J Oral Rehabil 24 (1997) 265-273
    • (1997) J Oral Rehabil , vol.24 , pp. 265-273
    • Jacobsen, P.H.1    Darr, A.H.2
  • 45
    • 1842579077 scopus 로고    scopus 로고
    • Influence of curing modes on crosslink density in polymer structures
    • Soh M.S., and Yap A.U. Influence of curing modes on crosslink density in polymer structures. J Dent 32 (2004) 321-326
    • (2004) J Dent , vol.32 , pp. 321-326
    • Soh, M.S.1    Yap, A.U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.