메뉴 건너뛰기




Volumn 59, Issue 7, 2012, Pages 2060-2067

Myocardial blood flow quantification from MRI by deconvolution using an exponential approximation basis

Author keywords

Deconvolution; myocardial perfusion; validation

Indexed keywords

CARDIOVASCULAR MAGNETIC RESONANCES; CLINICAL IMAGE DATA; CLINICAL ROUTINE; EXPONENTIAL APPROXIMATION BASIS; MYOCARDIAL BLOOD FLOW; MYOCARDIAL CONTOURS; MYOCARDIAL PERFUSION; RESPIRATORY MOTIONS; SIMULATED SIGNALS; VALIDATION;

EID: 84862751130     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2012.2197620     Document Type: Article
Times cited : (21)

References (28)
  • 2
    • 17644412367 scopus 로고    scopus 로고
    • Coronary artery disease: Myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography
    • DOI 10.1148/radiol.2352040454
    • S. Plein et al., "Coronary artery disease: Myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography1," Radiology, vol. 235, no. 2, pp. 423-430, 2005. (Pubitemid 40571077)
    • (2005) Radiology , vol.235 , Issue.2 , pp. 423-430
    • Plein, S.1    Radjenovic, A.2    Ridgway, J.P.3    Barmby, D.4    Greenwood, J.P.5    Ball, S.G.6    Sivananthan, M.U.7
  • 3
    • 0041663637 scopus 로고    scopus 로고
    • Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease
    • DOI 10.1161/01.CIR.0000080915.35024.A9
    • E. Nagel et al., "Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease," Circulation, vol. 108, no. 4, pp. 432-437, 2003. (Pubitemid 36935536)
    • (2003) Circulation , vol.108 , Issue.4 , pp. 432-437
    • Nagel, E.1    Klein, C.2    Paetsch, I.3    Hettwer, S.4    Schnackenburg, B.5    Wegscheider, K.6    Fleck, E.7
  • 4
    • 33947177606 scopus 로고    scopus 로고
    • Imaging sequences for first pass perfusion - A review
    • DOI 10.1080/10976640601187604, PII 772835472
    • P. Kellman and A. Arai, "Imaging sequences for first pass perfusion - A review," J. Cardiovasc. Magn. Reson., vol. 9, no. 3, pp. 525-537, 2007. (Pubitemid 46399023)
    • (2007) Journal of Cardiovascular Magnetic Resonance , vol.9 , Issue.3 , pp. 525-537
    • Kellman, P.1    Arai, A.E.2
  • 5
    • 44649140485 scopus 로고    scopus 로고
    • Myocardial first-pass perfusion cardiovascular magnetic resonance: History, theory, and current state of the art
    • B. Gerber et al., "Myocardial first-pass perfusion cardiovascular magnetic resonance: History, theory, and current state of the art," J. Cardiovasc. Magn. Reson., vol. 10, p. 18, 2008.
    • (2008) J. Cardiovasc. Magn. Reson. , vol.10 , pp. 18
    • Gerber, B.1
  • 6
    • 79952109371 scopus 로고    scopus 로고
    • Quantification ofmyocardial perfusion by cardiovascular magnetic resonance
    • M. Jerosch-Herold, "Quantification ofmyocardial perfusion by cardiovascular magnetic resonance," J. Cardiovasc. Magn. Reson., vol. 12, 2010.
    • (2010) J. Cardiovasc. Magn. Reson. , vol.12
    • Jerosch-Herold, M.1
  • 7
    • 57049116728 scopus 로고    scopus 로고
    • Deconvolution for DCE-MRI using an exponential approximation basis
    • S. Keeling, T. Kogler, and R. Stollberger, "Deconvolution for DCE-MRI using an exponential approximation basis," Med. Image Anal., vol. 13, no. 1, pp. 80-90, 2009.
    • (2009) Med. Image Anal. , vol.13 , Issue.1 , pp. 80-90
    • Keeling, S.1    Kogler, T.2    Stollberger, R.3
  • 8
    • 0001579379 scopus 로고
    • Equations for measuring blood flow by external monitoring of radio-isoptopes
    • K. Zierler, "Equations for measuring blood flow by external monitoring of radio-isoptopes," Circulat. Res., vol. 16, pp. 309-321, 1965.
    • (1965) Circulat. Res. , vol.16 , pp. 309-321
    • Zierler, K.1
  • 10
    • 0031906266 scopus 로고    scopus 로고
    • Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution
    • DOI 10.1118/1.598163
    • M. Jerosch-Herold, N. Wilke, A. Stillman, and R. Wilson, "Magnetic resonance quantification of the myocardial perfusion reserve with a fermi functionmodel for constrained deconvolution," Med. Phys., vol. 25, no. 1, pp. 73-84, 1998. (Pubitemid 28063691)
    • (1998) Medical Physics , vol.25 , Issue.1 , pp. 73-84
    • Jerosch-Herold, M.1    Wilke, N.2    Stillman, A.E.3    Wilson, R.F.4
  • 13
    • 0033645113 scopus 로고    scopus 로고
    • Stochastic modeling for magnetic resonance quantification of myocardial blood flow
    • San Diego, CA
    • R. Seethamraju et al., "Stochastic modeling for magnetic resonance quantification of myocardial blood flow," in Proc. SPIE Med. Imag., vol. 4121, San Diego, CA, 2000, pp. 140-147.
    • (2000) Proc. SPIE Med. Imag. , vol.4121 , pp. 140-147
    • Seethamraju, R.1
  • 14
    • 0036298279 scopus 로고    scopus 로고
    • Mapping myocardial perfusion with an intravascular MR contrast agent: Robustness of deconvolution methods at various blood flows
    • DOI 10.1002/mrm.10201
    • B. Neyran et al., "Mapping myocardial perfusion with an intravascular MRcontrast agent: Robustness of deconvolutionmethods at various blood flows," Magn. Reson. Med., vol. 48, no. 1, pp. 166-79, 2002. (Pubitemid 34721600)
    • (2002) Magnetic Resonance in Medicine , vol.48 , Issue.1 , pp. 166-179
    • Neyran, B.1    Janier, M.F.2    Casali, C.3    Revel, D.4    Canet, S.E.P.5
  • 15
    • 0035999417 scopus 로고    scopus 로고
    • Myocardial blood flow quantification with MRI by model-independent deconvolution
    • DOI 10.1118/1.1473135
    • M. Jerosch-Herold, C. Swingen, and R. Seethamraju, "Myocardial blood flow quantification with MRI by model-independent deconvolution,"Med. Phys., vol. 29, no. 5, pp. 886-897, 2002. (Pubitemid 34525918)
    • (2002) Medical Physics , vol.29 , Issue.5 , pp. 886-897
    • Jerosch-Herold, M.1    Swingen, C.2    Teja, S.R.3
  • 16
    • 54949100727 scopus 로고    scopus 로고
    • Fully automated motion correction in first-pass myocardial perfusion MR image sequences
    • Nov.
    • J. Milles et al., "Fully automated motion correction in first-pass myocardial perfusion MR image sequences," IEEETrans. Med. Imag., vol. 27, no. 11, pp. 1611-1621, Nov. 2008.
    • (2008) IEEETrans. Med. Imag. , vol.27 , Issue.11 , pp. 1611-1621
    • Milles, J.1
  • 17
    • 20444449819 scopus 로고    scopus 로고
    • Unsupervised motion-compensation of multi-slice cardiac perfusion MRI
    • DOI 10.1016/j.media.2004.10.002, PII S1361841505000174
    • M. Stegmann, H. Ólafsdóttir, and H. Larsson, "Unsupervised motion-compensation of multi-slice cardiac perfusion MRI," Med. Image Anal., vol. 9, no. 4, pp. 394-410, 2005. (Pubitemid 40822994)
    • (2005) Medical Image Analysis , vol.9 , Issue.4 SPEC. ISS. , pp. 394-410
    • Stegmann, M.B.1    Olafsdottir, H.2    Larsson, H.B.W.3
  • 18
    • 0024172568 scopus 로고    scopus 로고
    • Using dynamic programming for minimizing the energy of active contours in the presence of hard constraints
    • A. Amini, S. Tehrani, and T. Weymouth, "Using dynamic programming for minimizing the energy of active contours in the presence of hard constraints," in Proc. 2nd Int. Conf. Comput. Vis., 1988, pp. 95-99.
    • Proc. 2nd Int. Conf. Comput. Vis., 1988 , pp. 95-99
    • Amini, A.1    Tehrani, S.2    Weymouth, T.3
  • 19
    • 0026741340 scopus 로고
    • A fast algorithm for active contours and curvature estimation
    • D. Williams and M. Shah, "A fast algorithm for active contours and curvature estimation," CVGIP: Image Underst., vol. 55, no. 1, pp. 14-26, 1992.
    • (1992) CVGIP: Image Underst. , vol.55 , Issue.1 , pp. 14-26
    • Williams, D.1    Shah, M.2
  • 20
    • 84976736914 scopus 로고
    • Algorithm 587: Two algorithms for the linearly constrained least squares problem
    • R. Hanson and K. Haskell, "Algorithm 587: Two algorithms for the linearly constrained least squares problem," ACMTrans. Math. Softw., vol. 8, no. 3, pp. 323-333, 1982.
    • (1982) ACMTrans. Math. Softw. , vol.8 , Issue.3 , pp. 323-333
    • Hanson, R.1    Haskell, K.2
  • 21
    • 3142774916 scopus 로고    scopus 로고
    • Time delay for arrival of MR contrast agent in collateral-dependent myocardium
    • Jul.
    • M. Jerosch-Herold, X. Hu, N. Murthy, and R. Seethamraju, "Time delay for arrival of MR contrast agent in collateral-dependent myocardium,"IEEE Trans. Med. Imag., vol. 23, no. 7, pp. 881-890, Jul. 2004.
    • (2004) IEEE Trans. Med. Imag. , vol.23 , Issue.7 , pp. 881-890
    • Jerosch-Herold, M.1    Hu, X.2    Murthy, N.3    Seethamraju, R.4
  • 22
    • 79954453278 scopus 로고    scopus 로고
    • Impact of unexpected factors on quantitative myocardial perfusion and coronary flow reserve in young, asymptomatic volunteers
    • S. Sdringola et al., "Impact of unexpected factors on quantitative myocardial perfusion and coronary flow reserve in young, asymptomatic volunteers," J. Amer. College Cardiol. - Cardiovasc. Imag., vol. 4, no. 4, pp. 402-412, 2011.
    • (2011) J. Amer. College Cardiol. - Cardiovasc. Imag. , vol.4 , Issue.4 , pp. 402-412
    • Sdringola, S.1
  • 23
    • 84874363926 scopus 로고    scopus 로고
    • Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance
    • to be published
    • A. Chiribiri et al., "Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance," Magn. Reson. Med., 2012, to be published.
    • (2012) Magn. Reson. Med.
    • Chiribiri, A.1
  • 24
    • 0031240184 scopus 로고    scopus 로고
    • A methodology for evaluation of boundary detection algorithms on medical images
    • PII S0278006297075861
    • V. Chalana and Y. Kim, "A methodology for evaluation of boundary detection algorithms on medical images," IEEE Trans. Med. Imag., vol. 16, no. 5, pp. 642-652, Oct. 1997. (Pubitemid 127767643)
    • (1997) IEEE Transactions on Medical Imaging , vol.16 , Issue.5 , pp. 642-652
    • Chalana, V.1    Kim, Y.2
  • 25
    • 79953678948 scopus 로고    scopus 로고
    • Evaluation of the effect of myocardial segmentation errors on myocardial blood flow estimates from DCE-MRI
    • J. Biglands et al., "Evaluation of the effect of myocardial segmentation errors on myocardial blood flow estimates from DCE-MRI," Phys. Med. Biol., vol. 56, no. 8, pp. 2423-2443, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , Issue.8 , pp. 2423-2443
    • Biglands, J.1
  • 26
    • 0037192118 scopus 로고    scopus 로고
    • Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart
    • M. Cerqueira et al., "Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart," Circulation, vol. 105, no. 4, pp. 539-542, 2002.
    • (2002) Circulation , vol.105 , Issue.4 , pp. 539-542
    • Cerqueira, M.1
  • 27
    • 84860561780 scopus 로고    scopus 로고
    • Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance
    • M. Ishida et al., "Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance," J. Cardiovasc. Magn. Reson., vol. 13, p. 28, 2011.
    • (2011) J. Cardiovasc. Magn. Reson. , vol.13 , pp. 28
    • Ishida, M.1
  • 28
    • 41949130576 scopus 로고    scopus 로고
    • Nonlinear myocardial signal intensity correction improves quantification of contrast-enhanced first-pass MR perfusion in humans
    • DOI 10.1002/jmri.21286
    • L. Hsu, P. Kellman, and A. Arai, "Nonlinear myocardial signal intensity correction improves quantification of contrast-enhanced first-pass MR perfusion in humans," J. Magn. Reson. Imag., vol. 27, no. 4, pp. 793-801, 2008. (Pubitemid 351508094)
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , Issue.4 , pp. 793-801
    • Hsu, L.-Y.1    Kellman, P.2    Arai, A.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.