메뉴 건너뛰기




Volumn 4, Issue 4, 2011, Pages 402-412

Impact of unexpected factors on quantitative myocardial perfusion and coronary flow reserve in young, asymptomatic volunteers

Author keywords

absolute myocardial perfusion; coronary flow reserve; normal volunteers; positron emission tomography

Indexed keywords

CAFFEINE; CALCIUM; DIPYRIDAMOLE; HIGH DENSITY LIPOPROTEIN; NICOTINE;

EID: 79954453278     PISSN: 1936878X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcmg.2011.02.008     Document Type: Article
Times cited : (102)

References (29)
  • 1
    • 58349112528 scopus 로고    scopus 로고
    • Fractional flow reserve versus angiography for guiding percutaneous coronary intervention
    • FAME Study Investigators
    • P.A. Tonino, B. De Bruyne, N.H. Pijls FAME Study Investigators Fractional flow reserve versus angiography for guiding percutaneous coronary intervention N Engl J Med 360 2009 213 224
    • (2009) N Engl J Med , vol.360 , pp. 213-224
    • Tonino, P.A.1    De Bruyne, B.2    Pijls, N.H.3
  • 3
    • 34548009153 scopus 로고    scopus 로고
    • Cardiologists' use of percutaneous coronary interventions for stable coronary artery disease
    • DOI 10.1001/archinte.167.15.1604
    • G.A. Lin, R.A. Dudley, and R.F. Redberg Cardiologists' use of percutaneous coronary interventions for stable coronary artery disease Arch Intern Med 167 2007 1604 1609 (Pubitemid 47280340)
    • (2007) Archives of Internal Medicine , vol.167 , Issue.15 , pp. 1604-1609
    • Lin, G.A.1    Dudley, R.A.2    Redberg, R.F.3
  • 4
    • 77956031422 scopus 로고    scopus 로고
    • Coronary artery disease: Percent stenosis in CADa flaw in current practice
    • K.L. Gould, and N.P. Johnson Coronary artery disease: percent stenosis in CADa flaw in current practice Nat Rev Cardiol 7 2010 482 484
    • (2010) Nat Rev Cardiol , vol.7 , pp. 482-484
    • Gould, K.L.1    Johnson, N.P.2
  • 5
    • 68549107828 scopus 로고    scopus 로고
    • Does coronary flow trump coronary anatomy?
    • K.L. Gould Does coronary flow trump coronary anatomy? J Am Coll Cardiol Img 2 2009 1009 1023
    • (2009) J Am Coll Cardiol Img , vol.2 , pp. 1009-1023
    • Gould, K.L.1
  • 6
    • 0034352160 scopus 로고    scopus 로고
    • Problems of coronary flow reserve
    • DOI 10.1114/1.1308503
    • J.I. Hoffman Problems of coronary flow reserve Ann Biomed Eng 28 2000 884 896 (Pubitemid 32085373)
    • (2000) Annals of Biomedical Engineering , vol.28 , Issue.8 , pp. 884-896
    • Hoffman, J.I.E.1
  • 8
    • 44149085425 scopus 로고    scopus 로고
    • Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: Quantitative validation
    • DOI 10.2967/jnumed.107.049163
    • K.L. Gould, T. Pan, C. Loghin, N.P. Johnson, and S. Sdringola Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: quantitative validation J Nucl Med 49 2008 738 745 (Pubitemid 351717538)
    • (2008) Journal of Nuclear Medicine , vol.49 , Issue.5 , pp. 738-745
    • Gould, K.L.1    Pan, T.2    Loghin, C.3    Johnson, N.P.4    Sdringola, S.5
  • 9
    • 34447306296 scopus 로고    scopus 로고
    • Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: A definitive analysis of causes, consequences, and corrections
    • DOI 10.2967/jnumed.107.039792
    • K.L. Gould, T. Pan, C. Loghin, N.P. Johnson, A. Guha, and S. Sdringola Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections J Nucl Med 48 2007 1112 1121 (Pubitemid 47052651)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.7 , pp. 1112-1121
    • Gould, K.L.1    Pan, T.2    Loghin, C.3    Johnson, N.P.4    Guha, A.5    Sdringola, S.6
  • 10
    • 3242731469 scopus 로고    scopus 로고
    • Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: Clinical significance, causes, and solutions
    • C. Loghin, S. Sdringola, and K.L. Gould Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions J Nucl Med 45 2004 1029 1039 (Pubitemid 47611690)
    • (2004) Journal of Nuclear Medicine , vol.45 , Issue.6 , pp. 1029-1039
    • Loghin, C.1    Sdringola, S.2    Gould, K.L.3
  • 11
    • 0034712718 scopus 로고    scopus 로고
    • Frequency and clinical implications of fluid dynamically significant diffuse coronary artery disease manifest as graded, longitudinal, base-to- apex myocardial perfusion abnormalities by noninvasive positron emission tomography
    • K.L. Gould, Y. Nakagawa, and K. Nakagawa Frequency and clinical implications of fluid dynamically significant diffuse coronary artery disease manifest as graded, longitudinal, base-to-apex myocardial perfusion abnormalities by noninvasive positron emission tomography Circulation 101 2000 1931 1939 (Pubitemid 30225274)
    • (2000) Circulation , vol.101 , Issue.16 , pp. 1931-1939
    • Gould, K.L.1    Nakagawa, Y.2    Nakagawa, K.3    Sdringola, S.4    Hess, M.J.5    Haynie, M.6    Parker, N.7    Mullani, N.8    Kirkeeide, R.9
  • 12
    • 0037438911 scopus 로고    scopus 로고
    • Combined intense lifestyle and pharmacologic lipid treatment further reduce coronary events and myocardial perfusion abnormalities compared with usual-care cholesterol-lowering drugs in coronary artery disease
    • DOI 10.1016/S0735-1097(02)02693-1, PII S0735109702026931
    • S. Sdringola, K. Nakagawa, and Y. Nakagawa Combined intense lifestyle and pharmacologic lipid treatment further reduce coronary events and myocardial perfusion abnormalities compared with usual-care cholesterol-lowering drugs in coronary artery disease J Am Coll Cardiol 41 2003 263 272 (Pubitemid 36092195)
    • (2003) Journal of the American College of Cardiology , vol.41 , Issue.2 , pp. 263-272
    • Sdringola, S.1    Nakagawa, K.2    Nakagawa, Y.3    Wamique Yusuf, S.4    Boccalandro, F.5    Mullani, N.6    Haynie, M.7    Hess, M.J.8    Gould, K.L.9
  • 13
    • 33747006237 scopus 로고    scopus 로고
    • Mechanisms of progression and regression of coronary artery disease by PET related to treatment intensity and clinical events at long-term follow-up
    • S. Sdringola, C. Loghin, F. Boccalandro, and K.L. Gould Mechanisms of progression and regression of coronary artery disease by PET related to treatment intensity and clinical events at long-term follow-up J Nucl Med 47 2006 59 67 (Pubitemid 46768513)
    • (2006) Journal of Nuclear Medicine , vol.47 , Issue.1 , pp. 59-67
    • Sdringola, S.1    Loghin, C.2    Boccalandro, F.3    Gould, K.L.4
  • 14
    • 27744516622 scopus 로고    scopus 로고
    • Clinical evaluation of a new concept: Resting myocardial perfusion heterogeneity quantified by Markovian analysis of PET identifies coronary microvascular dysfunction and early atherosclerosis in 1,034 subjects
    • N.P. Johnson, and K.L. Gould Clinical evaluation of a new concept: resting myocardial perfusion heterogeneity quantified by Markovian analysis of PET identifies coronary microvascular dysfunction and early atherosclerosis in 1,034 subjects J Nucl Med 46 2005 1427 1437 (Pubitemid 46173253)
    • (2005) Journal of Nuclear Medicine , vol.46 , Issue.9 , pp. 1427-1437
    • Johnson, N.P.1    Gould, K.L.2
  • 15
    • 0035970093 scopus 로고    scopus 로고
    • High prevalence of myocardial perfusion abnormalities on positron emission tomography in asymptomatic persons with a parent or sibling with coronary artery disease
    • S. Sdringola, D. Patel, and K.L. Gould High prevalence of myocardial perfusion abnormalities on positron emission tomography in asymptomatic persons with a parent or sibling with coronary artery disease Circulation 103 2001 496 501 (Pubitemid 32116232)
    • (2001) Circulation , vol.103 , Issue.4 , pp. 496-501
    • Sdringola, S.1    Patel, D.2    Gould, K.L.3
  • 16
    • 0029815801 scopus 로고    scopus 로고
    • Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia
    • K. Yoshida, N. Mullani, and K.L. Gould Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia J Nucl Med 37 1996 1701 1712 (Pubitemid 26337184)
    • (1996) Journal of Nuclear Medicine , vol.37 , Issue.10 , pp. 1701-1712
    • Yoshida, K.1    Mullani, N.2    Gould, K.L.3
  • 17
    • 79958176945 scopus 로고    scopus 로고
    • Partial volume correction incorporating Rb-82 positron range for quantitative myocardial perfusion PET based on systolic-diastolic activity ratios and phantom measurements
    • N.P. Johnson, S. Sdringola, and K.L. Gould Partial volume correction incorporating Rb-82 positron range for quantitative myocardial perfusion PET based on systolic-diastolic activity ratios and phantom measurements J Nucl Cardiol 2010 Dec 24 [E-pub ahead of print]
    • (2010) J Nucl Cardiol
    • Johnson, N.P.1    Sdringola, S.2    Gould, K.L.3
  • 18
    • 78649382557 scopus 로고    scopus 로고
    • Agreement of visual estimation of coronary artery calcium from low-dose CT attenuation correction scans in hybrid PET/CT and SPECT/CT with standard Agatston score
    • A.J. Einstein, L.L. Johnson, and S. Bokhari Agreement of visual estimation of coronary artery calcium from low-dose CT attenuation correction scans in hybrid PET/CT and SPECT/CT with standard Agatston score J Am Coll Cardiol 56 2010 1914 1921
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1914-1921
    • Einstein, A.J.1    Johnson, L.L.2    Bokhari, S.3
  • 20
    • 33646446933 scopus 로고    scopus 로고
    • Invasive assessment of the coronary microcirculation: Superior reproducibility and less hemodynamic dependence of index of microcirculatory resistance compared with coronary flow reserve
    • M.K. Ng, A.C. Yeung, and W.F. Fearon Invasive assessment of the coronary microcirculation: superior reproducibility and less hemodynamic dependence of index of microcirculatory resistance compared with coronary flow reserve Circulation 113 2006 2054 2061
    • (2006) Circulation , vol.113 , pp. 2054-2061
    • Ng, M.K.1    Yeung, A.C.2    Fearon, W.F.3
  • 21
    • 0028867136 scopus 로고
    • Effect of caffeine on myocardial blood flow at rest and during pharmacological vasodilation
    • M. Bttcher, J. Czernin, K.T. Sun, M.E. Phelps, and H.R. Schelbert Effect of caffeine on myocardial blood flow at rest and during pharmacological vasodilation J Nucl Med 36 1995 2016 2021
    • (1995) J Nucl Med , vol.36 , pp. 2016-2021
    • Bttcher, M.1    Czernin, J.2    Sun, K.T.3    Phelps, M.E.4    Schelbert, H.R.5
  • 22
    • 0032533438 scopus 로고    scopus 로고
    • Acute effects of nicotine content in cigarettes on coronary flow velocity and coronary flow reserve in men
    • DOI 10.1016/S0002-9149(98)00614-6
    • T. Tanaka, Y. Oka, I. Tawara, T. Sada, and Y. Kira Acute effects of nicotine content in cigarettes on coronary flow velocity and coronary flow reserve in men Am J Cardiol 82 1998 1275 1278 A9 (Pubitemid 28541287)
    • (1998) American Journal of Cardiology , vol.82 , Issue.10 , pp. 1275-1278
    • Tanaka, T.1    Oka, Y.2    Tawara, I.3    Sada, T.4    Kira, Y.5
  • 24
    • 77951667605 scopus 로고    scopus 로고
    • Incidence of caffeine in serum of patients undergoing dipyridamole myocardial perfusion stress test by an intensive versus routine caffeine history screening
    • L.T. Banko, S.A. Haq, and D.A. Rainaldi Incidence of caffeine in serum of patients undergoing dipyridamole myocardial perfusion stress test by an intensive versus routine caffeine history screening Am J Cardiol 105 2010 1474 1479
    • (2010) Am J Cardiol , vol.105 , pp. 1474-1479
    • Banko, L.T.1    Haq, S.A.2    Rainaldi, D.A.3
  • 27
    • 0028842619 scopus 로고
    • Interobserver and interstudy variability of myocardial blood flow and flow-reserve measurements with nitrogen 13 ammonia-labeled positron emission tomography
    • S. Sawada, O. Muzik, R.S. Beanlands, E. Wolfe, G.D. Hutchins, and M. Schwaiger Interobserver and interstudy variability of myocardial blood flow and flow-reserve measurements with nitrogen 13 ammonia-labeled positron emission tomography J Nucl Cardiol 2 1995 413 422
    • (1995) J Nucl Cardiol , vol.2 , pp. 413-422
    • Sawada, S.1    Muzik, O.2    Beanlands, R.S.3    Wolfe, E.4    Hutchins, G.D.5    Schwaiger, M.6
  • 28
    • 70350521667 scopus 로고    scopus 로고
    • Myocardial perfusion quantitation with 15O-labelled water PET: High reproducibility of the new cardiac analysis software (Carimas)
    • S.V. Nesterov, C. Han, and M. Mki Myocardial perfusion quantitation with 15O-labelled water PET: high reproducibility of the new cardiac analysis software (Carimas) Eur J Nucl Med Mol Imaging 36 2009 1594 1602
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , pp. 1594-1602
    • Nesterov, S.V.1    Han, C.2    Mki, M.3
  • 29
    • 0022576040 scopus 로고
    • Intracoronary papaverine: An ideal coronary vasodilator for studies of the coronary circulation in conscious humans
    • R.F. Wilson, and C.W. White Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans Circulation 73 1986 444 451 (Pubitemid 16133022)
    • (1986) Circulation , vol.73 , Issue.3 , pp. 444-451
    • Wilson, R.F.1    White, C.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.