메뉴 건너뛰기




Volumn 26, Issue 15, 2012, Pages 1711-1717

Observation of ion coalescence in Orbitrap Fourier transform mass spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

LOCKS (FASTENERS); MASS SPECTROMETERS; MASS SPECTROMETRY; SIGNAL PROCESSING; TRAPPED IONS;

EID: 84862742637     PISSN: 09514198     EISSN: 10970231     Source Type: Journal    
DOI: 10.1002/rcm.6289     Document Type: Article
Times cited : (65)

References (19)
  • 1
    • 0027608882 scopus 로고
    • Use of mass spectrometric molecular weight information to identify proteins in sequence database
    • M. Mann, P. Hojrup, P. Roepstorff,. Use of mass spectrometric molecular weight information to identify proteins in sequence database. Biol. Mass Spectrom. 1993, 22, 338.
    • (1993) Biol. Mass Spectrom. , vol.22 , pp. 338
    • Mann, M.1    Hojrup, P.2    Roepstorff, P.3
  • 3
    • 0033621537 scopus 로고    scopus 로고
    • Mass spectrometry: From genomics to proteomics
    • J. R. Yates III,. Mass spectrometry: from genomics to proteomics. Trends Genet. 2000, 16, 5.
    • (2000) Trends Genet. , vol.16 , pp. 5
    • Yates III, J.R.1
  • 5
    • 2742576125 scopus 로고    scopus 로고
    • Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements
    • R. A. Zubarev, P. Hakansson, B. Sundqvist,. Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements. Anal. Chem. 1996, 68, 4060.
    • (1996) Anal. Chem. , vol.68 , pp. 4060
    • Zubarev, R.A.1    Hakansson, P.2    Sundqvist, B.3
  • 6
    • 0035253342 scopus 로고    scopus 로고
    • Baseline mass resolution of peptide isobars: A record for molecular mass resolution
    • F. He, C. L. Hendrickson, A. G. Marshall,. Baseline mass resolution of peptide isobars: A record for molecular mass resolution. Anal. Chem. 2001, 73, 647.
    • (2001) Anal. Chem. , vol.73 , pp. 647
    • He, F.1    Hendrickson, C.L.2    Marshall, A.G.3
  • 7
    • 0041408938 scopus 로고    scopus 로고
    • Electrostatic axially-harmonic orbital trapping: A novel high-performance technique of mass analysis
    • A. Makarov,. Electrostatic axially-harmonic orbital trapping: A novel high-performance technique of mass analysis. Anal. Chem. 2000, 72, 1156.
    • (2000) Anal. Chem. , vol.72 , pp. 1156
    • Makarov, A.1
  • 9
    • 33745264884 scopus 로고    scopus 로고
    • Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer
    • A. Makarov, E. Denisov, O. Lange, S. Horning,. Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer. J. Am. Soc. Mass Spectrom. 2006, 17, 977.
    • (2006) J. Am. Soc. Mass Spectrom. , vol.17 , pp. 977
    • Makarov, A.1    Denisov, E.2    Lange, O.3    Horning, S.4
  • 11
    • 67650711335 scopus 로고    scopus 로고
    • Performance evaluation of a high-field Orbitrap mass analyzer
    • A. Makarov, E. Denisov, O. Lange,. Performance evaluation of a high-field Orbitrap mass analyzer. J. Am. Soc. Mass Spectrom. 2009, 20, 1391.
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , pp. 1391
    • Makarov, A.1    Denisov, E.2    Lange, O.3
  • 13
    • 0003375301 scopus 로고
    • Peak confluence phenomenon in Fourier transform ion cyclotron resonance phenomenon
    • Y. Naito, M. Inoue,. Peak confluence phenomenon in Fourier transform ion cyclotron resonance phenomenon. J. Mass Spectrom. Soc. Jpn. 1994, 42, 1.
    • (1994) J. Mass Spectrom. Soc. Jpn. , vol.42 , pp. 1
    • Naito, Y.1    Inoue, M.2
  • 14
    • 0001365594 scopus 로고
    • Cyclotron motion of two Coulombically interacting ion clouds with implication to Fourier-transform ion cyclotron resonance mass spectrometry
    • D. W. Mitchell, R. D. Smith,. Cyclotron motion of two Coulombically interacting ion clouds with implication to Fourier-transform ion cyclotron resonance mass spectrometry. Phys. Rev. E 1995, 52, 4366.
    • (1995) Phys. Rev. e , vol.52 , pp. 4366
    • Mitchell, D.W.1    Smith, R.D.2
  • 17
    • 67651187880 scopus 로고    scopus 로고
    • Synchronization
    • DOI: 10.4249/scholarpedia.1459.
    • A. Pikoysky, M. Rosenblum,. Synchronization. Scholarpedia 2007, 2, 1459. DOI: 10.4249/scholarpedia.1459.
    • (2007) Scholarpedia , vol.2 , pp. 1459
    • Pikoysky, A.1    Rosenblum, M.2
  • 18
    • 58249087566 scopus 로고    scopus 로고
    • The spontaneous loss of coherence catastrophe in Fourier transform ion cyclotron resonance mass spectrometry
    • K. Aizikov, R. Mathur, P. B. O'Connor,. The spontaneous loss of coherence catastrophe in Fourier transform ion cyclotron resonance mass spectrometry. J. Am. Soc. Mass Spectrom. 2009, 20, 247.
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , pp. 247
    • Aizikov, K.1    Mathur, R.2    O'Connor, P.B.3
  • 19
    • 84862728673 scopus 로고    scopus 로고
    • Desychronization
    • DOI: 10.4249/scholarpedia.1352.
    • O. V. Popovych, P. A. Tass, C. Hauptmann,. Desychronization. Scholarpedia 2011, 6, 1352. DOI: 10.4249/scholarpedia.1352.
    • (2011) Scholarpedia , vol.6 , pp. 1352
    • Popovych, O.V.1    Tass, P.A.2    Hauptmann, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.