-
2
-
-
0041387395
-
Measurements of gamma-knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector
-
Araki F., Ikegami T., Ishidoya T., et al. Measurements of gamma-knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector. Med. Phys. 2003, 30:1976-1981.
-
(2003)
Med. Phys.
, vol.30
, pp. 1976-1981
-
-
Araki, F.1
Ikegami, T.2
Ishidoya, T.3
-
3
-
-
3142671924
-
Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams for linear accelerator and Cyber-knife
-
Araki F., Moribe N., Shimonobou T., et al. Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams for linear accelerator and Cyber-knife. Med. Phys. 2004, 31:1980-1986.
-
(2004)
Med. Phys.
, vol.31
, pp. 1980-1986
-
-
Araki, F.1
Moribe, N.2
Shimonobou, T.3
-
4
-
-
0032726570
-
An application of Gafchromic MD-55 film for 67.5MeV clinical proton beam dosimetry
-
Daftari I., Castenadas C., Petti P.L., et al. An application of Gafchromic MD-55 film for 67.5MeV clinical proton beam dosimetry. Phys. Med. Biol. 1999, 44:2735-2745.
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 2735-2745
-
-
Daftari, I.1
Castenadas, C.2
Petti, P.L.3
-
5
-
-
0029011227
-
A European quality assurance network for radiotherapy: dose measurement procedure
-
Derreumaux S., Chavaudra J., Bridier A., et al. A European quality assurance network for radiotherapy: dose measurement procedure. Phys. Med. Biol. 1995, 40:1191-1208.
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1191-1208
-
-
Derreumaux, S.1
Chavaudra, J.2
Bridier, A.3
-
6
-
-
0035252644
-
External audits of electron beams using mailed TLD dosimetry: preliminary results
-
Gomola I., Dam J.V., Isern-Verdumb J., et al. External audits of electron beams using mailed TLD dosimetry: preliminary results. Radiother. Oncol. 2001, 58:163-168.
-
(2001)
Radiother. Oncol.
, vol.58
, pp. 163-168
-
-
Gomola, I.1
Dam, J.V.2
Isern-Verdumb, J.3
-
7
-
-
0033795042
-
General characteristics of the use of silicon diode detectors for clinical dosimetry in proton beams
-
Grusell E., Medin J. General characteristics of the use of silicon diode detectors for clinical dosimetry in proton beams. Phys. Med. Biol. 2000, 45:2573-2582.
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 2573-2582
-
-
Grusell, E.1
Medin, J.2
-
8
-
-
33846882152
-
Experimental evaluation of a MOSFET dosimeter for proton dose measurements
-
Kohno R., Nishio T., Miyagishi T., et al. Experimental evaluation of a MOSFET dosimeter for proton dose measurements. Phys. Med. Biol. 2006, 51:6077-6086.
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 6077-6086
-
-
Kohno, R.1
Nishio, T.2
Miyagishi, T.3
-
10
-
-
38949110011
-
Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams
-
Mizuno H., Kanai T., Kusan Y., et al. Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams. Radiother. Oncol. 2008, 86:258-263.
-
(2008)
Radiother. Oncol.
, vol.86
, pp. 258-263
-
-
Mizuno, H.1
Kanai, T.2
Kusan, Y.3
-
11
-
-
60249097139
-
A comparison of the dosimetric characteristics of a glass rod dosimeter and a thermoluminescent dosimeter for mailed dosimeter
-
Rah J., Hong J., Kim G., et al. A comparison of the dosimetric characteristics of a glass rod dosimeter and a thermoluminescent dosimeter for mailed dosimeter. Radiat. Meas. 2009, 44:18-22.
-
(2009)
Radiat. Meas.
, vol.44
, pp. 18-22
-
-
Rah, J.1
Hong, J.2
Kim, G.3
-
12
-
-
58049184315
-
Feasibility study of radiophotoluminescent glass rod dosimeter postal dose intercomparison for high energy photon beam
-
Rah J., Kim S., Cheong K., Lee J., et al. Feasibility study of radiophotoluminescent glass rod dosimeter postal dose intercomparison for high energy photon beam. Appl. Radiat. Isot. 2009, 67:324-328.
-
(2009)
Appl. Radiat. Isot.
, vol.67
, pp. 324-328
-
-
Rah, J.1
Kim, S.2
Cheong, K.3
Lee, J.4
-
13
-
-
65449186980
-
The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams
-
Reft C.S. The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams. Med. Phys. 2009, 36:1690-1699.
-
(2009)
Med. Phys.
, vol.36
, pp. 1690-1699
-
-
Reft, C.S.1
-
14
-
-
0034300792
-
Plastic scintillator investigations for relative dosimetry in proton-therapy
-
Torrisi L. Plastic scintillator investigations for relative dosimetry in proton-therapy. Nucl. Instrum. Methods Phys. Res. 2000, 170:523-530.
-
(2000)
Nucl. Instrum. Methods Phys. Res.
, vol.170
, pp. 523-530
-
-
Torrisi, L.1
-
15
-
-
75149168436
-
LiF TLD-100 as a dosimeter in high energy proton beam therapy-can it yield accurate results?
-
Zullo J.R., Kudchadker R.J., Zhu X.R., et al. LiF TLD-100 as a dosimeter in high energy proton beam therapy-can it yield accurate results?. Med. Dosim. 2009, 35:63-66.
-
(2009)
Med. Dosim.
, vol.35
, pp. 63-66
-
-
Zullo, J.R.1
Kudchadker, R.J.2
Zhu, X.R.3
|