메뉴 건너뛰기




Volumn 31, Issue 7, 2004, Pages 1980-1986

Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and Cyber-Knife

Author keywords

Dosimetry; Output factors; Radiophotoluminescent glass rod dosimeter; Small field measurements

Indexed keywords

DIODES; DOSIMETERS; DOSIMETRY; ELECTRON BEAMS; GLASS; LINEAR ACCELERATORS; PHOTOELECTRONS; PHOTONS; SILICON DETECTORS; X RAYS;

EID: 3142671924     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1758351     Document Type: Article
Times cited : (91)

References (19)
  • 1
    • 0041387395 scopus 로고    scopus 로고
    • Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector
    • F. Araki, T. Ikegami, T. Ishidoya, and D. H. Kubo, "Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector," Med. Phys. 30, 1976-1981 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1976-1981
    • Araki, F.1    Ikegami, T.2    Ishidoya, T.3    Kubo, D.H.4
  • 2
    • 0036854522 scopus 로고    scopus 로고
    • Dosimetry and mechanical accuracy of the first rotating Gamma-Knife system installed in North America
    • H. D. Kubo and F. Araki, "Dosimetry and mechanical accuracy of the first rotating Gamma-Knife system installed in North America," Med. Phys. 29, 2497-2505 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2497-2505
    • Kubo, H.D.1    Araki, F.2
  • 3
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetry techniques in stereotactic radiosurgery
    • M. Heydarian, P. W. Hoban, and A. H. Beddoe, "A comparison of dosimetry techniques in stereotactic radiosurgery," Phys. Med. Biol. 41, 93-110 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 4
    • 0036852599 scopus 로고    scopus 로고
    • Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry
    • H. R. Lee, M. Pankuch, J. C. Chu, and J. J. Spokas, "Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry," Med. Phys. 29, 2489-2496 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2489-2496
    • Lee, H.R.1    Pankuch, M.2    Chu, J.C.3    Spokas, J.J.4
  • 5
    • 0027210922 scopus 로고
    • Comments on dose measurements for narrow beam in radiosurgery
    • A. Wu, R. D. Zwicker, A. M. Kalend, and Z. Zheng, "Comments on dose measurements for narrow beam in radiosurgery," Med. Phys. 20, 777-779 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 777-779
    • Wu, A.1    Zwicker, R.D.2    Kalend, A.M.3    Zheng, Z.4
  • 6
    • 0028049726 scopus 로고
    • Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam
    • P. W. Hoban, M. Heydarian, W. A. Beckham, and A. H. Beddoe, "Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam," Phys. Med. Biol. 39, 1219-1229 (1994).
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1219-1229
    • Hoban, P.W.1    Heydarian, M.2    Beckham, W.A.3    Beddoe, A.H.4
  • 7
    • 84907106851 scopus 로고
    • Selective shielding of a p-Si detector for quality independence
    • G. Rickner and E. Grusell, "Selective shielding of a p-Si detector for quality independence," Acta Radiol. Oncol. 24, 65-69 (1985).
    • (1985) Acta Radiol. Oncol. , vol.24 , pp. 65-69
    • Rickner, G.1    Grusell, E.2
  • 8
    • 84907105761 scopus 로고
    • 60Co and 8 and 16 MV x-ray radiation
    • 60Co and 8 and 16 MV x-ray radiation," Acta Radiol. Oncol. 24, 205-208 (1985).
    • (1985) Acta Radiol. Oncol. , vol.24 , pp. 205-208
    • Rickner, G.1
  • 9
    • 0031855026 scopus 로고    scopus 로고
    • A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams
    • P. N. Mobit, A. E. Nahum, and P. Mayles, "A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams," Phys. Med. Biol. 43, 2015-2032 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2015-2032
    • Mobit, P.N.1    Nahum, A.E.2    Mayles, P.3
  • 14
    • 0041961679 scopus 로고    scopus 로고
    • A few remarks on photoluminescence dosimetry with high energy x-rays
    • M. Tsuda, "A few remarks on photoluminescence dosimetry with high energy x-rays," Jpn. J. Med. 20, 131-139 (2000).
    • (2000) Jpn. J. Med. , vol.20 , pp. 131-139
    • Tsuda, M.1
  • 15
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams
    • AAPM American Association of Physicists in Medicine, Task Group 21, "A protocol for the determination of absorbed dose from high-energy photon and electron beams," Med. Phys. 10, 741-771 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 741-771
  • 16
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • AAPM American Association of Physicists in Medicine, Task Group 51, "AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams," Med. Phys. 26, 1847-1870 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1847-1870
  • 18
    • 0029922271 scopus 로고    scopus 로고
    • The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments
    • P. N. Mobit, P. Mayles, and A. E. Nahum, "The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments," Phys. Med. Biol. 41, 387-398 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 387-398
    • Mobit, P.N.1    Mayles, P.2    Nahum, A.E.3
  • 19
    • 0029896246 scopus 로고    scopus 로고
    • The energy correction factor of LiF thermoluminescent dosimeters in megavoltage electron beams: Monte Carlo simulations and experiments
    • P. N. Mobit, A. E. Nahum, and P. Mayles, "The energy correction factor of LiF thermoluminescent dosimeters in megavoltage electron beams: Monte Carlo simulations and experiments," Phys. Med. Biol. 41, 979-993 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 979-993
    • Mobit, P.N.1    Nahum, A.E.2    Mayles, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.