메뉴 건너뛰기




Volumn 23, Issue 7, 2012, Pages 832-836

Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants

Author keywords

Bone density; Cone beam computed tomography; Dental implants; Insertion torque; Primary stability; Resonance frequency analysis

Indexed keywords

ANIMAL; ARTICLE; BONE DENSITY; CONE BEAM COMPUTED TOMOGRAPHY; DENTAL PROCEDURE; FEMUR HEAD; METHODOLOGY; RADIOGRAPHY; SWINE; TOOTH IMPLANT; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE;

EID: 84862184538     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2011.02203.x     Document Type: Article
Times cited : (116)

References (36)
  • 1
    • 33746375362 scopus 로고    scopus 로고
    • Biomechanical aspects of initial intraosseous stability and implant design
    • a quantitative micro-morphometric analysis. : -.
    • Akca, K., Chang, T.L., Tekdemir, I. & Fanuscu, M.I. (2006) Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis. Clinical Oral Implants Research17: 465-472.
    • (2006) Clinical Oral Implants Research , vol.17 , pp. 465-472
    • Akca, K.1    Chang, T.L.2    Tekdemir, I.3    Fanuscu, M.I.4
  • 3
    • 70249144681 scopus 로고    scopus 로고
    • Implant stability and bone density
    • assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. : -.
    • Cehreli, M.C., Kokat, A.M., Comert, A., Akkocaoglu, M., Tekdemir, I. & Akca, K. (2009) Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. Clinical Oral Implants Research20: 1163-1169.
    • (2009) Clinical Oral Implants Research , vol.20 , pp. 1163-1169
    • Cehreli, M.C.1    Kokat, A.M.2    Comert, A.3    Akkocaoglu, M.4    Tekdemir, I.5    Akca, K.6
  • 4
    • 0026167719 scopus 로고
    • Early failures in 4,641 consecutively placed brånemark dental implants
    • a study from stage 1 surgery to the connection of completed prostheses. : -.
    • Friberg, B., Jemt, T. & Lekholm, U. (1991) Early failures in 4, 641 consecutively placed brånemark dental implants: a study from stage 1 surgery to the connection of completed prostheses. The International Journal of Oral & Maxillofacial Implants6: 142-146.
    • (1991) The International Journal of Oral & Maxillofacial Implants , vol.6 , pp. 142-146
    • Friberg, B.1    Jemt, T.2    Lekholm, U.3
  • 8
    • 0019198182 scopus 로고
    • Computed medical imaging
    • Hounsfield, G.N. (1980) Computed medical imaging. Science210: 22-28.
    • (1980) Science , vol.210 , pp. 22-28
    • Hounsfield, G.N.1
  • 9
    • 34547217298 scopus 로고    scopus 로고
    • Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation
    • Huwiler, M.A., Pjetursson, B.E., Bosshardt, D.D., Salvi, G.E. & Lang, N.P. (2007) Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clinical Oral Implants Research18: 275-280.
    • (2007) Clinical Oral Implants Research , vol.18 , pp. 275-280
    • Huwiler, M.A.1    Pjetursson, B.E.2    Bosshardt, D.D.3    Salvi, G.E.4    Lang, N.P.5
  • 10
    • 17844379203 scopus 로고    scopus 로고
    • Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement
    • a clinical study. : -.
    • Ikumi, N. & Tsutsumi, S. (2005) Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study. The International Journal of Oral & Maxillofacial Implants20: 253-260.
    • (2005) The International Journal of Oral & Maxillofacial Implants , vol.20 , pp. 253-260
    • Ikumi, N.1    Tsutsumi, S.2
  • 11
    • 0026084439 scopus 로고
    • The excessive loss of brånemark fixtures in type IV bone
    • a 5-year analysis. : -.
    • Jaffin, R.A. & Berman, C.L. (1991) The excessive loss of brånemark fixtures in type IV bone: a 5-year analysis. Journal of Periodontology62: 2-4.
    • (1991) Journal of Periodontology , vol.62 , pp. 2-4
    • Jaffin, R.A.1    Berman, C.L.2
  • 14
    • 33750711362 scopus 로고    scopus 로고
    • Effects of anodized oxidation or turned implants on bone healing after using conventional drilling or trabecular compaction technique
    • Histomorphometric analysis and RFA. : -.
    • Kim, S.K., Lee, H.N., Choi, Y.C., Heo, S.J., Lee, C.W. & Choie, M.K. (2006) Effects of anodized oxidation or turned implants on bone healing after using conventional drilling or trabecular compaction technique: Histomorphometric analysis and RFA. Clinical Oral Implants Research17: 644-650.
    • (2006) Clinical Oral Implants Research , vol.17 , pp. 644-650
    • Kim, S.K.1    Lee, H.N.2    Choi, Y.C.3    Heo, S.J.4    Lee, C.W.5    Choie, M.K.6
  • 16
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • In: Branemark, P.I., Zarb, G.A. & Albrektsson, T., eds. Tissue integrated proslhesis: . pp. -. Chicago 1985: Quintessence Publishing Co.
    • Lekholm, U. & Zarb, G.A. (1985) Patient selection and preparation. In: Branemark, P.I., Zarb, G.A. & Albrektsson, T., eds. Tissue integrated proslhesis: Osseointegration in clinical dentistry. pp. 199-208. Chicago 1985: Quintessence Publishing Co.
    • (1985) Osseointegration in clinical dentistry , pp. 199-208
    • Lekholm, U.1    Zarb, G.A.2
  • 19
    • 0005176889 scopus 로고    scopus 로고
    • Part 1. Rationale for implants, 3. Diagnostic Imaging and Techniques
    • Misch, C.B., ed. . pp. -. St. Louis: Mosby Year Book.
    • Misch, C.E. (2008) Part 1. Rationale for implants, 3. Diagnostic Imaging and Techniques, Misch, C.B., ed. Contemporary Implant Dentistry. pp. 38-67. St. Louis: Mosby Year Book.
    • (2008) Contemporary Implant Dentistry , pp. 38-67
    • Misch, C.E.1
  • 20
    • 64549109838 scopus 로고    scopus 로고
    • Evaluation of voxel values in mandibular cancellous bone
    • relationship between cone-beam computed tomography and multislice helical computed tomography. : -.
    • Naitoh, M., Hirukawa, A., Katsumata, A. & Ariji, E. (2009) Evaluation of voxel values in mandibular cancellous bone: relationship between cone-beam computed tomography and multislice helical computed tomography. Clinical Oral Implants Research20: 503-506.
    • (2009) Clinical Oral Implants Research , vol.20 , pp. 503-506
    • Naitoh, M.1    Hirukawa, A.2    Katsumata, A.3    Ariji, E.4
  • 21
    • 77955485043 scopus 로고    scopus 로고
    • Reliability of voxel values from cone-beam computed tomography for dental use in evaluating bone mineral density
    • Nomura, Y., Watanabe, H., Honda, E. & Kurabayashi, T. (2010) Reliability of voxel values from cone-beam computed tomography for dental use in evaluating bone mineral density. Clinical Oral Implants Research21: 558-562.
    • (2010) Clinical Oral Implants Research , vol.21 , pp. 558-562
    • Nomura, Y.1    Watanabe, H.2    Honda, E.3    Kurabayashi, T.4
  • 22
    • 0035261160 scopus 로고    scopus 로고
    • Bone classification
    • an objective scale of bone density using the computerized tomography scan. : -.
    • Norton, M.R. & Gamble, C. (2001) Bone classification: an objective scale of bone density using the computerized tomography scan. Clinical Oral Implants Research12: 79-84.
    • (2001) Clinical Oral Implants Research , vol.12 , pp. 79-84
    • Norton, M.R.1    Gamble, C.2
  • 23
    • 0033954645 scopus 로고    scopus 로고
    • Efficient correction for CT image artifacts caused by objects extending outside the scan field of view
    • Ohnesorge, B., Flohr, T., Schwarz, K., Heiken, J.P. & Bae, K.T. (2000) Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. Medical Physics27: 39-46.
    • (2000) Medical Physics , vol.27 , pp. 39-46
    • Ohnesorge, B.1    Flohr, T.2    Schwarz, K.3    Heiken, J.P.4    Bae, K.T.5
  • 24
    • 77955053708 scopus 로고    scopus 로고
    • Radiation dose and protection in dentistry
    • Okano, T. & Jaideep, S. (2010) Radiation dose and protection in dentistry. Japanese Dental Science Review46: 112-121.
    • (2010) Japanese Dental Science Review , vol.46 , pp. 112-121
    • Okano, T.1    Jaideep, S.2
  • 30
    • 34547140173 scopus 로고    scopus 로고
    • In vivo evaluation of the trabecular bone behavior to porous electrostatic spray deposition-derived calcium phosphate coatings
    • Siebers, M.C., Wolke, J.G., Walboomers, X.F., Leeuwenburgh, S.C. & Jansen, J.A. (2007) In vivo evaluation of the trabecular bone behavior to porous electrostatic spray deposition-derived calcium phosphate coatings. Clinical Oral Implants Research18: 354-361.
    • (2007) Clinical Oral Implants Research , vol.18 , pp. 354-361
    • Siebers, M.C.1    Wolke, J.G.2    Walboomers, X.F.3    Leeuwenburgh, S.C.4    Jansen, J.A.5
  • 31
    • 84862169210 scopus 로고    scopus 로고
    • Evaluation of clinical bone quality on implant installation -reliability about hounsfield unit on NSCT and CBCT
    • 119 (Abstract).
    • Sogo, M. (2009) Evaluation of clinical bone quality on implant installation -reliability about hounsfield unit on NSCT and CBCT. Journal of Japanese Society of Oral Implantology Special Issue, 119 (Abstract).
    • (2009) Journal of Japanese Society of Oral Implantology Special Issue
    • Sogo, M.1
  • 32
    • 67649173038 scopus 로고    scopus 로고
    • Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability
    • Song, Y.D., Jun, S.H. & Kwon, J.J. (2009) Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability. The International Journal of Oral & Maxillofacial Implants24: 59-64.
    • (2009) The International Journal of Oral & Maxillofacial Implants , vol.24 , pp. 59-64
    • Song, Y.D.1    Jun, S.H.2    Kwon, J.J.3
  • 33
    • 58149330623 scopus 로고    scopus 로고
    • Influence of bone density on implant stability parameters and implant success
    • a retrospective clinical study. : .
    • Turkyilmaz, I. & McGlumphy, E.A. (2008) Influence of bone density on implant stability parameters and implant success: a retrospective clinical study. BioMed Central Oral Health8: 32.
    • (2008) BioMed Central Oral Health , vol.8 , pp. 32
    • Turkyilmaz, I.1    McGlumphy, E.A.2
  • 35
    • 33751351701 scopus 로고    scopus 로고
    • Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
    • Turkyilmaz, I., Tozum, T.F., Tumer, C. & Ozbek, E.N. (2006) Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. Journal of Oral Rehabilitation33: 881-888.
    • (2006) Journal of Oral Rehabilitation , vol.33 , pp. 881-888
    • Turkyilmaz, I.1    Tozum, T.F.2    Tumer, C.3    Ozbek, E.N.4
  • 36
    • 34547174147 scopus 로고    scopus 로고
    • Relations between the bone density values from computerized tomography, and implant stability parameters
    • a clinical study of 230 regular platform implants. : -.
    • Turkyilmaz, I., Tumer, C., Ozbek, E.N. & Tozum, T.F. (2007) Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. Journal of Clinical Periodontology34: 716-722.
    • (2007) Journal of Clinical Periodontology , vol.34 , pp. 716-722
    • Turkyilmaz, I.1    Tumer, C.2    Ozbek, E.N.3    Tozum, T.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.