메뉴 건너뛰기




Volumn 174, Issue , 2010, Pages 113-156

Commercially available continuous glucose monitoring systems

(1)  Henning, Timothy a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84862111867     PISSN: 00692883     EISSN: None     Source Type: Book Series    
DOI: None     Document Type: Article
Times cited : (3)

References (41)
  • 1
    • 25644453616 scopus 로고    scopus 로고
    • Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes: Normative values
    • DOI 10.2337/diacare.28.10.2361
    • Bode BW, Schwartz S, Stubbs HA, Block JE. Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes: normative values. Diabetes Care 2005, 28, 2361-2366. (Pubitemid 41384277)
    • (2005) Diabetes Care , vol.28 , Issue.10 , pp. 2361-2366
    • Bode, B.W.1    Schwartz, S.2    Stubbs, H.A.3    Block, J.E.4
  • 4
    • 0032799808 scopus 로고    scopus 로고
    • A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel
    • DOI 10.1021/ac990060r
    • Russsell RJ, Pishko MV, Gefrides CC, McShane MJ, Cote GL. A fluorescence-based glucose biosensor using concanavalin A and dextran encapsulated in a poly(ethylene glycol) hydrogel. Analytical Chemistry 1999, 71, 3126-3132. (Pubitemid 29372728)
    • (1999) Analytical Chemistry , vol.71 , Issue.15 , pp. 3126-3132
    • Russell, R.J.1    Pishko, M.V.2    Gefrides, C.C.3    McShane, M.J.4    Cote, G.L.5
  • 5
    • 0033624437 scopus 로고    scopus 로고
    • Optical glucose sensing in biological fluids: An overview
    • DOI 10.1117/1.429962
    • Nichols RJ, Cote GL. Optical glucose sensing in biological fluids: an overview. Journal of Biomedical Optics 2000, 5, 5-16. (Pubitemid 30556694)
    • (2000) Journal of Biomedical Optics , vol.5 , Issue.1 , pp. 5-16
    • McNichols, R.J.1    Cote, G.L.2
  • 6
    • 0032515425 scopus 로고    scopus 로고
    • Engineering biosensors by introducing fluorescent allosteric signal transducers: Construction of a novel glucose sensor
    • DOI 10.1021/ja972993f
    • Marvin JS, Hellinga HW. Engineering biosensors by introducing fluorescent allosteric signal transducers: construction of a novel glucose sensor. Journal of the American Chemical Society 1998, 120, 7-11. (Pubitemid 28046421)
    • (1998) Journal of the American Chemical Society , vol.120 , Issue.1 , pp. 7-11
    • Marvin, J.S.1    Hellinga, H.W.2
  • 7
    • 0035979773 scopus 로고    scopus 로고
    • Design of bioelectronic interfaces by exploiting hinge-bending motions in proteins
    • DOI 10.1126/science.1062461
    • Benson DE, Conrad DW, de Lorimer RM, Trammell SA, Hallinga HW. Design of bioelectronic interfaces by exploiting hinge-bending motion of proteins. Science 2001, 293, 1641-1644. (Pubitemid 32807840)
    • (2001) Science , vol.293 , Issue.5535 , pp. 1641-1644
    • Benson, D.E.1    Conrad, D.W.2    De Lorimier, R.M.3    Trammell, S.A.4    Hellinga, H.W.5
  • 8
    • 33746499602 scopus 로고    scopus 로고
    • Binding and signaling of surface-immobilized reagentless fluorescent biosensors derived from periplasmic binding proteins
    • DOI 10.1110/ps.062261606
    • de Lorimier RM, Tian Y, Hellinga HW. Binding and signaling of surface-immobilized reagentless fluorescent biosensors derived from periplasmic binding proteins. Protein Science 2006, 15, 1936-1944. (Pubitemid 44141511)
    • (2006) Protein Science , vol.15 , Issue.8 , pp. 1936-1944
    • De Lorimier, R.M.1    Tian, Y.2    Hellinga, H.W.3
  • 9
    • 33748423435 scopus 로고    scopus 로고
    • In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring
    • DOI 10.1089/dia.2006.8.296
    • Ballerstadt R, Evans C, Gowda A, McNichols R. In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring. Diabetes Technology & Therapeutics 2006, 8, 296-311. (Pubitemid 46100524)
    • (2006) Diabetes Technology and Therapeutics , vol.8 , Issue.3 , pp. 296-311
    • Ballerstadt, R.1    Evans, C.2    Gowda, A.3    McNichols, R.4
  • 10
    • 0032995738 scopus 로고    scopus 로고
    • Spectroscopic and clinical aspects of noninvasive glucose measurements
    • Khalil O. Spectroscopic and clinical aspects of noninvasive glucose measurements. Clinical Chemistry 1999, 45, 165-177. (Pubitemid 29079113)
    • (1999) Clinical Chemistry , vol.45 , Issue.2 , pp. 165-177
    • Khalil, O.S.1
  • 11
    • 6044275963 scopus 로고    scopus 로고
    • Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
    • DOI 10.1089/dia.2004.6.660
    • Khalil O. Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. Diabetes Technology & Therapeutics 2004, 6, 660-697. (Pubitemid 39383073)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.5 , pp. 660-697
    • Khalil, O.S.1
  • 15
    • 0037178205 scopus 로고    scopus 로고
    • Mediated biosensors
    • DOI 10.1016/S0956-5663(01)00313-X, PII S095656630100313X
    • Chaubey A, Malhotra BD. Mediated biosensors. Biosensors & Bioelectronics 2002, 17, 441-456. (Pubitemid 34327396)
    • (2002) Biosensors and Bioelectronics , vol.17 , Issue.6-7 , pp. 441-456
    • Chaubey, A.1    Malhotra, B.D.2
  • 16
    • 0023482117 scopus 로고
    • Implantable glucose sensors: Choosing the appropriate sensing strategy
    • Pickup JC, Shaw GW, Claremont DJ. Implantable glucose sensors: choosing the appropriate sensing strategy. Biosensors 1987/1988, 3, 335-346.
    • (1987) Biosensors , vol.3 , pp. 335-346
    • Pickup, J.C.1    Shaw, G.W.2    Claremont, D.J.3
  • 17
    • 0024541965 scopus 로고
    • In vivo molecular sensing in diabetes mellitus: An implantable glucose sensor with direct electron transfer
    • DOI 10.1007/BF00265097
    • Pickup JC, Shaw GW, Claremont DJ. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia 1989, 32, 213-217. (Pubitemid 19117104)
    • (1989) Diabetologia , vol.32 , Issue.3 , pp. 213-217
    • Pickup, J.C.1    Shaw, G.W.2    Claremont, D.J.3
  • 18
    • 0025870762 scopus 로고
    • In vitro testing of a simply constructed, highly stable glucose sensor suitable for implantation in diabetic patients
    • Shaw GW, Claremont DJ, Pickup JC. In vitro testing of a simply constructed, highly stable glucose sensor suitable for implantation in diabetic patients. Biosensors & Bioelectronics 1991, 6, 401-406.
    • (1991) Biosensors & Bioelectronics , vol.6 , pp. 401-406
    • Shaw, G.W.1    Claremont, D.J.2    Pickup, J.C.3
  • 19
    • 33750428427 scopus 로고
    • Electrical connection of enzyme redox centers to electrodes
    • Heller A. Electrical connection of enzyme redox centers to electrodes. Journal of Physical Chemistry 1992, 96, 3579-3587.
    • (1992) Journal of Physical Chemistry , vol.96 , pp. 3579-3587
    • Heller, A.1
  • 20
  • 21
    • 0037459369 scopus 로고    scopus 로고
    • Plugging into enzymes: Nanowiring of redox enzymes by a gold nanoparticle
    • DOI 10.1126/science.1080664
    • Xiao Y, Patolsky F, Katz E, Hainfeld J, Willner I. "Plugging into enzymes": Nanowiring of redox enzymes by a gold nanoparticle. Science 2003, 299, 1877-1881. (Pubitemid 36356654)
    • (2003) Science , vol.299 , Issue.5614 , pp. 1877-1881
    • Xiao, Y.1    Patolsky, F.2    Katz, E.3    Hainfeld, J.F.4    Willner, I.5
  • 23
    • 0242469052 scopus 로고    scopus 로고
    • Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode
    • DOI 10.1016/S0956-5663(03)00172-6
    • Liu S, Ju H. Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode. Biosensors & Bioelectronics 2003, 19, 177-183. (Pubitemid 37377965)
    • (2003) Biosensors and Bioelectronics , vol.19 , Issue.3 , pp. 177-183
    • Liu, S.1    Ju, H.2
  • 24
    • 0038361349 scopus 로고    scopus 로고
    • Plugging metal connectors into enzymes
    • DOI 10.1038/nbt0603-631
    • Heller A. Plugging metal connectors into enzymes. Nature Biotechnology 2003, 21, 631-632. (Pubitemid 36638088)
    • (2003) Nature Biotechnology , vol.21 , Issue.6 , pp. 631-632
    • Heller, A.1
  • 25
    • 0014191637 scopus 로고
    • The enzyme electrode
    • Updike SJ, Hicks GP. The enzyme electrode. Nature 1967, 214, 986-988.
    • (1967) Nature , vol.214 , pp. 986-988
    • Updike, S.J.1    Hicks, G.P.2
  • 27
    • 0020058620 scopus 로고
    • Implanting the glucose enzyme electrode: Problems, progress, and alternative solutions
    • Updike SJ, Shults M, Ekman B. Implanting the glucose enzyme electrode: problems, progress, and alternative solutions. Diabetes Care 1982, 5, 207-212. (Pubitemid 12117167)
    • (1982) Diabetes Care , vol.5 , Issue.3 , pp. 207-212
    • Updike, S.J.1    Shults, M.2    Ekman, B.3
  • 31
    • 0028106630 scopus 로고
    • Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
    • Gilligan BJ, Shults MC, Rhodes RK, Updike J. Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model. Diabetes Care 1994, 17, 882-887. (Pubitemid 24235512)
    • (1994) Diabetes Care , vol.17 , Issue.8 , pp. 882-887
    • Gilligan, B.J.1    Shults, M.C.2    Rhodes, R.K.3    Updike, S.J.4
  • 33
    • 0033970025 scopus 로고    scopus 로고
    • A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration
    • Updike SJ, Shults MC, Gilligan BJ, Rhodes RK. A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. Diabetes Care 2000, 23, 208-214. (Pubitemid 30071026)
    • (2000) Diabetes Care , vol.23 , Issue.2 , pp. 208-214
    • Updike, S.J.1    Shults, M.C.2    Gilligan, B.J.3    Rhodes, R.K.4
  • 36
    • 1442275324 scopus 로고    scopus 로고
    • Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia
    • The Diabetes Research in Children Network (DirecNet) Study Group
    • The Diabetes Research in Children Network (DirecNet) Study Group. Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia. Diabetes Care 2004, 27, 722-726.
    • (2004) Diabetes Care , vol.27 , pp. 722-726
  • 37
    • 0022353391 scopus 로고
    • Accuracy of perceiving blood glucose in IDDM
    • Cox DJ, Clarke WL, Gonder-Frederick L, Pohl S, Hoover C, Snyder A, Zimbelman L, Carter WR, Bobbitt S, Pennebaker J. Accuracy of perceiving blood glucose in IDDM. Diabetes Care 1985, 8, 529-536. (Pubitemid 16194474)
    • (1985) Diabetes Care , vol.8 , Issue.6 , pp. 529-536
    • Cox, D.J.1    Clarke, W.L.2    Gonder-Frederick, L.3
  • 38
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke WL, Cox D, Gonder-Frederick L, Carter W,Pohl S.Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987, 10, 622-628. (Pubitemid 17158937)
    • (1987) Diabetes Care , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 39
    • 0032942994 scopus 로고    scopus 로고
    • Continuous intravenous insulin infusion reduces the incidence of deep sternal wound infection in diabetic patients after cardiac surgical procedures
    • Furnary AP, Kerr KJ, Grunkemeier GL, Starr A. Continuous intravenous insulin infusion reduces the incidence of deep sternal wound infection in diabetic patients after cardiac surgical procedures. Annals of Thoracic Surgery 1999, 67, 352-360.
    • (1999) Annals of Thoracic Surgery , vol.67 , pp. 352-360
    • Furnary, A.P.1    Kerr, K.J.2    Grunkemeier, G.L.3    Starr, A.4
  • 40
    • 0030974812 scopus 로고    scopus 로고
    • Prospective randomized study of intensive insulin treatment on long term survival after acute myocardial infarction in patients with diabetes mellitus
    • Diabetes Mellitus Insulin Glucose Infusion in Acute Myocardial Infarction Study Group
    • Diabetes Mellitus Insulin Glucose Infusion in Acute Myocardial Infarction Study Group. Prospective randomized study of intensive insulin treatment on long term survival after acute myocardial infarction in patients with diabetes mellitus. British Medical Journal 1997, 314, 1512.
    • (1997) British Medical Journal , vol.314 , pp. 1512


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.