메뉴 건너뛰기




Volumn 16, Issue 5, 2012, Pages 1015-1028

Automatic motion compensation of free breathing acquired myocardial perfusion data by using independent component analysis

Author keywords

Heart; Independent component analysis; Motion compensation; Perfusion; Registration

Indexed keywords

AUTOMATIC ANALYSIS; AUTOMATICALLY GENERATED; COMPENSATION SCHEME; CONTRAST AGENT; CORRELATION COEFFICIENT; FREE BREATHING; IMAGE SERIES; INDEPENDENT COMPONENTS; INTENSITY CHANGE; INTENSITY PROFILES; MULTI-PASS; MYOCARDIAL PERFUSION; NON-LINEAR TRANSFORMATIONS; PATIENT DATA; PERFUSION; PERFUSION IMAGES; QUASI-PERIODIC MOTION; REFERENCE IMAGE; REGISTRATION; RUNTIMES; TIME FREQUENCY ANALYSIS; TIME-INTENSITY CURVES;

EID: 84861993120     PISSN: 13618415     EISSN: 13618423     Source Type: Journal    
DOI: 10.1016/j.media.2012.02.004     Document Type: Article
Times cited : (48)

References (40)
  • 5
    • 0041704686 scopus 로고    scopus 로고
    • Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm
    • Dornier C., Ivancevic M.K., Thevenaz P., Vallee J.P. Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm. Journal of Magnetic Resonance Imaging 2003, 18:160-168.
    • (2003) Journal of Magnetic Resonance Imaging , vol.18 , pp. 160-168
    • Dornier, C.1    Ivancevic, M.K.2    Thevenaz, P.3    Vallee, J.P.4
  • 10
    • 84879925404 scopus 로고    scopus 로고
    • Beyond mutual information: a simple and robust alternative
    • In: Hans-Peter Meinzer, A.H., Handels, Heinz, Tolxdorff, T. (Eds.), Bildverarbeitung für die Medizin 2005. Springer, Berlin Heidelberg
    • Haber, E., Modersitzki, J., 2005. Beyond mutual information: a simple and robust alternative. In: Hans-Peter Meinzer, A.H., Handels, Heinz, Tolxdorff, T. (Eds.), Bildverarbeitung für die Medizin 2005. Springer, Berlin Heidelberg, pp. 350-354.
    • (2005) , pp. 350-354
    • Haber, E.1    Modersitzki, J.2
  • 11
    • 0032629347 scopus 로고    scopus 로고
    • Fast and robust fixed-point algorithms for independent component analysis
    • Hyvarinen A. Fast and robust fixed-point algorithms for independent component analysis. IEEE Transactions on Neural Networks 1999, 10:626-634.
    • (1999) IEEE Transactions on Neural Networks , vol.10 , pp. 626-634
    • Hyvarinen, A.1
  • 12
    • 79952109371 scopus 로고    scopus 로고
    • Quantification of myocardial perfusion by cardiovascular magnetic resonance
    • Jerosch-Herold M. Quantification of myocardial perfusion by cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance 2010, 12. 10.1186/1532-429X-12-57.
    • (2010) Journal of Cardiovascular Magnetic Resonance , vol.12
    • Jerosch-Herold, M.1
  • 13
    • 84861966386 scopus 로고    scopus 로고
    • The NLopt nonlinear-optimization package. <>.
    • Johnson, S.G., 2011. The NLopt nonlinear-optimization package. <>. http://ab-initio.mit.edu/nlopt.
    • (2011)
    • Johnson, S.G.1
  • 14
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P., Epstein F.H., McVeigh E.R. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magnetic Resonance in Medicine 2001, 45:846-852.
    • (2001) Magnetic Resonance in Medicine , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 17
    • 79958768148 scopus 로고    scopus 로고
    • Pseudo ground truth based nonrigid registration of myocardial perfusion MRI
    • Li C., Sun Y., Chai P. Pseudo ground truth based nonrigid registration of myocardial perfusion MRI. Medical Image Analysis 2011, 15:449-459. 10.1016/j.media.2011.02.001.
    • (2011) Medical Image Analysis , vol.15 , pp. 449-459
    • Li, C.1    Sun, Y.2    Chai, P.3
  • 18
    • 0035155615 scopus 로고    scopus 로고
    • A hierarchical approach to elastic registration based on mutual information
    • Likar B., Pernus F. A hierarchical approach to elastic registration based on mutual information. Image and Vision Computing 2001, 19:33-44.
    • (2001) Image and Vision Computing , vol.19 , pp. 33-44
    • Likar, B.1    Pernus, F.2
  • 21
    • 84861975164 scopus 로고    scopus 로고
    • Analysis of first-pass myocardial perfusion mri using independent component analysis
    • In: Proceedings of SPIE, SPIE
    • Milles, J., van der Geesta, R.J., Jerosch-Heroldb, M., Reibera, J.H., Lelieveldta, B.P., 2006. Analysis of first-pass myocardial perfusion mri using independent component analysis. In: Proceedings of SPIE, SPIE, pp. 61441R-6-1441R-9.
    • (2006)
    • Milles, J.1    van der Geesta, R.J.2    Jerosch-Heroldb, M.3    Reibera, J.H.4    Lelieveldta, B.P.5
  • 24
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • Nelder J., Mead R. A simplex method for function minimization. Computer Journal 1965, 7:308-313.
    • (1965) Computer Journal , vol.7 , pp. 308-313
    • Nelder, J.1    Mead, R.2
  • 25
    • 84861977759 scopus 로고    scopus 로고
    • Nonrigid registration of myocardial perfusion MRI
    • In: Proceedings of Svenska Symposium i Bildanalys, SSBA 2005, Malmø, Sweden, SSBA.
    • ólafsdóttir, H., 2005. Nonrigid registration of myocardial perfusion MRI. In: Proceedings of Svenska Symposium i Bildanalys, SSBA 2005, Malmø, Sweden, SSBA.
    • (2005)
    • ólafsdóttir, H.1
  • 27
    • 0042405180 scopus 로고    scopus 로고
    • Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint
    • Rohlfing, T., Jr., C.R.M., Bluemke, D.A., Jacobs, M.A., 2003. Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint. IEEE Transactions on Medical Imaging 22, 730-741.
    • (2003) IEEE Transactions on Medical Imaging , vol.22 , pp. 730-741
    • Rohlfing Jr., T.C.R.M.1    Bluemke, D.A.2    Jacobs, M.A.3
  • 29
    • 20444449819 scopus 로고    scopus 로고
    • Unsupervised motion-compensation of multi-slice cardiac perfusion MRI. Medical Image Analysis 9, 394-410. (Functional Imaging and Modeling of the Heart - FIMH03, Functional Imaging and Modeling of the Heart).
    • Stegmann, M., lafsdttir, H., Larsson, H., 2005. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI. Medical Image Analysis 9, 394-410. (Functional Imaging and Modeling of the Heart - FIMH03, Functional Imaging and Modeling of the Heart).
    • (2005)
    • Stegmann, M.1    lafsdttir, H.2    Larsson, H.3
  • 30
    • 33646397022 scopus 로고    scopus 로고
    • Deformation-based mapping of volume change from serial brain MRI in the presence of local tissue contrast change
    • Studholme C., Drapaca C., Iordanova B., Cardenas V. Deformation-based mapping of volume change from serial brain MRI in the presence of local tissue contrast change. IEEE Transactions on Medical Imaging 2006, 25:626-639.
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , pp. 626-639
    • Studholme, C.1    Drapaca, C.2    Iordanova, B.3    Cardenas, V.4
  • 33
    • 26444539768 scopus 로고    scopus 로고
    • Shifted limited-memory variable metric methods for large-scale unconstrained minimization
    • Vlcek J., Luksan L. Shifted limited-memory variable metric methods for large-scale unconstrained minimization. Journal of Computational and Applied Mathematics 2006, 186:365-390.
    • (2006) Journal of Computational and Applied Mathematics , vol.186 , pp. 365-390
    • Vlcek, J.1    Luksan, L.2
  • 34
    • 84861966384 scopus 로고    scopus 로고
    • MIA - A Software for Medical Image Analyis
    • <> (accessed 16.02.11).
    • Wollny, G., 2010. MIA - A Software for Medical Image Analyis. <> (accessed 16.02.11). http://mia.sourceforge.net.
    • (2010)
    • Wollny, G.1
  • 36
    • 84861963357 scopus 로고    scopus 로고
    • New Developments in Biomedical Engineering
    • In-Teh, Vukovar, Croacia. On Breathing Motion Compensation in Myocardial Perfusion Imaging
    • Wollny, G., Ledesma-Carbayo, M.J., Kellman, P., Santos, A., 2010b. New Developments in Biomedical Engineering. In-Teh, Vukovar, Croacia. On Breathing Motion Compensation in Myocardial Perfusion Imaging. pp. 235-247.
    • (2010) , pp. 235-247
    • Wollny, G.1    Ledesma-Carbayo, M.J.2    Kellman, P.3    Santos, A.4
  • 37
    • 84884652836 scopus 로고    scopus 로고
    • Nonrigid motion compensation of free breathing acquired myocardial perfusion data
    • In: Handels, H., Horsch, A., Lehmann, T., Meinzer, H.P. (Eds.), Bildverarbeitung für die Medizin 2011, Berlin Heidelberg
    • Wollny, G., Kellman, P., Santos, A., Ledesma, M.J., 2011. Nonrigid motion compensation of free breathing acquired myocardial perfusion data. In: Handels, H., Horsch, A., Lehmann, T., Meinzer, H.P. (Eds.), Bildverarbeitung für die Medizin 2011, Berlin Heidelberg. pp. 84-88.
    • (2011) , pp. 84-88
    • Wollny, G.1    Kellman, P.2    Santos, A.3    Ledesma, M.J.4
  • 38
    • 40449137625 scopus 로고    scopus 로고
    • First-pass myocardial perfusion image registration by maximization of normalized mutual information
    • Wong K.K., Yang E.S., Wu E.X., Tse H.F., Wong S.T. First-pass myocardial perfusion image registration by maximization of normalized mutual information. Journal of Magnetic Resonance Imaging 2008, 27:529-537.
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , pp. 529-537
    • Wong, K.K.1    Yang, E.S.2    Wu, E.X.3    Tse, H.F.4    Wong, S.T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.