메뉴 건너뛰기




Volumn 8427, Issue , 2012, Pages

Single-layer graphene based SPR biochips for tuberculosis bacillus detection

Author keywords

Biosensor; Graphene; Insertion Sequence 6110 (IS6110); Loop mediated isothermal amplification (LAMP); Self assembled monolayer (SAM); Surface plasmon resonance (SPR); Tuberculosis bacillus (TB)

Indexed keywords

AU ELECTRODES; AU FILM; HIGHLY SENSITIVE; INSERTION SEQUENCES; LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP); SINGLE LAYER; TUBERCULOSIS BACILLUS (TB);

EID: 84861957232     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.922698     Document Type: Conference Paper
Times cited : (21)

References (10)
  • 1
    • 79955103273 scopus 로고    scopus 로고
    • Global tuberculosis control: World Health Organization report 2011. (http://whqlibdoc.who.int/publications/2011/9789241564380-eng.pdf)
    • (2011) Global Tuberculosis Control
  • 4
    • 80051552957 scopus 로고    scopus 로고
    • Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens
    • I. K. Neonakis, D. A. Spandidos and E. Petinaki, "Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens," Eur J Clin Microbiol Infect Dis 30, 937-942(2011).
    • (2011) Eur J Clin Microbiol Infect Dis , vol.30 , pp. 937-942
    • Neonakis, I.K.1    Spandidos, D.A.2    Petinaki, E.3
  • 6
    • 61649093984 scopus 로고    scopus 로고
    • Graphene-based single-bacterium resolution biodevice and DNA transistor: Interfacing graphene derivatives with nanoscale and microscale biocomponents
    • N. Mohanty and V. Berry, "Graphene-Based Single-Bacterium Resolution Biodevice and DNA Transistor: Interfacing Graphene Derivatives with Nanoscale and Microscale Biocomponents," Nano Lett., 8 (12), 4469-4476 (2008).
    • (2008) Nano Lett. , vol.8 , Issue.12 , pp. 4469-4476
    • Mohanty, N.1    Berry, V.2
  • 7
    • 79955847649 scopus 로고    scopus 로고
    • Graphene-encapsulated nanoparticle-based biosensor for the selective detection of cancer biomarkers
    • S. Myung, A. Solanki, C. Kim, J. Park, K. S. Kim, K.-B. Lee, "graphene-encapsulated nanoparticle-based biosensor for the selective detection of cancer biomarkers," Advanced Materials 23, 2221-2225 (2011).
    • (2011) Advanced Materials , vol.23 , pp. 2221-2225
    • Myung, S.1    Solanki, A.2    Kim, C.3    Park, J.4    Kim, K.S.5    Lee, K.-B.6
  • 9
    • 68749109957 scopus 로고    scopus 로고
    • Direct electrochemical reduction of single-layer graphene oxide and subsequent functionalization with glucose oxidase
    • Z. Wang, X. Zhou, J. Zhang, F. Boey, and H. Zhang, "Direct Electrochemical Reduction of Single-Layer Graphene Oxide and Subsequent Functionalization with Glucose Oxidase," J. Phys. Chem. C 113, 14071-14075 (2009).
    • (2009) J. Phys. Chem. C , vol.113 , pp. 14071-14075
    • Wang, Z.1    Zhou, X.2    Zhang, J.3    Boey, F.4    Zhang, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.