메뉴 건너뛰기




Volumn 8427, Issue , 2012, Pages

Diode laser based photoacoustic gas measuring instruments intended for medical research

Author keywords

Ammonia; Medical research; Methane; Near infrared; Non invasive; Oral cavity; Photoacoustic spectroscopy

Indexed keywords

ABSORPTION LINES; CHEMICALLY BONDED; CLINICAL TRIAL; CROSS SENSITIVITY; DISTRIBUTED FEEDBACK DIODE LASER; GAS SAMPLES; GLASS TUBES; HIGH SELECTIVITY; HUMAN SKIN; INTEGRATION TIME; MEASURING INSTRUMENTS; MEDICAL RESEARCH; METABOLIC PROCESS; MINIMUM DETECTABLE CONCENTRATIONS; NEAR INFRARED; NON-INVASIVE; NON-INVASIVE DIAGNOSIS; ORAL CAVITY; PRE-CONCENTRATION; TRACE-GAS SENSORS;

EID: 84861935644     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.921644     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 1
    • 33749016240 scopus 로고    scopus 로고
    • Current status of clinical breath analysis
    • Risby, T. H. and Solga, S. F., "Current status of clinical breath analysis," Appl. Phys. B 85, 421-426 (2006).
    • (2006) Appl. Phys. B , vol.85 , pp. 421-426
    • Risby, T.H.1    Solga, S.F.2
  • 2
    • 0035836626 scopus 로고    scopus 로고
    • Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis
    • Narasimhan, L. R., Goodman, W. and Patel C. K. N., "Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis," Proc. Natl. Acad. Sci. 98, 4617-4621 (2001).
    • (2001) Proc. Natl. Acad. Sci. , vol.98 , pp. 4617-4621
    • Narasimhan, L.R.1    Goodman, W.2    Patel, C.K.N.3
  • 3
    • 79955757488 scopus 로고    scopus 로고
    • Real time ammonia detection in exhaled human breath using a distributed feedback quantum cascade laser based sensor
    • Lewicki, R., Kosterev, A. A., Thomazy, D. M., Risby, T. H., Solga, S., Schwartz, T. B., Tittel, F. K., "Real time ammonia detection in exhaled human breath using a distributed feedback quantum cascade laser based sensor " Proc. SPIE 7945, 50K-2 (2011).
    • (2011) Proc. SPIE , vol.7945
    • Lewicki, R.1    Kosterev, A.A.2    Thomazy, D.M.3    Risby, T.H.4    Solga, S.5    Schwartz, T.B.6    Tittel, F.K.7
  • 4
    • 21444456617 scopus 로고    scopus 로고
    • Identification of gas emanated from human skin: Methane, ethylene, and ethane
    • Nose, K., Nunome, Y., Kondo, T., Araki, S. and Tsuda, T., "Identification of gas emanated from human skin: methane, ethylene, and ethane," Anal. Sci. 21, 625-628 (2005).
    • (2005) Anal. Sci. , vol.21 , pp. 625-628
    • Nose, K.1    Nunome, Y.2    Kondo, T.3    Araki, S.4    Tsuda, T.5
  • 5
    • 84882357623 scopus 로고    scopus 로고
    • Findings of skin gases and their possibilities in healthcare monitoring
    • S. Karger AG, Basel
    • Tsuda, T., Ohkuwa, T. and Itoh, H., "Findings of skin gases and their possibilities in healthcare monitoring," [Gas Biology Research in Clinical Practice], S. Karger AG, Basel, 125-132 (2011).
    • (2011) Gas Biology Research in Clinical Practice , pp. 125-132
    • Tsuda, T.1    Ohkuwa, T.2    Itoh, H.3
  • 8
    • 34447108806 scopus 로고    scopus 로고
    • A review of the current literature on aetiology and measurement methods of halitosis
    • van den Broek, A. M., Feenstra, L. and de Baat, C., "A review of the current literature on aetiology and measurement methods of halitosis," J. Dent. 35, 627-635 (2007).
    • (2007) J. Dent , vol.35 , pp. 627-635
    • Van Den Broek, A.M.1    Feenstra, L.2    De Baat, C.3
  • 10
    • 78651107348 scopus 로고    scopus 로고
    • Photoacoustic instruments for practical applications: Present, potentials, and future challenges
    • Bozóki, Z., Pogány, A. and Szabó, G., "Photoacoustic instruments for practical applications: present, potentials, and future challenges," Appl. Spectrosc. Rev. 46, 1-37 (2011).
    • (2011) Appl. Spectrosc. Rev , vol.46 , pp. 1-37
    • Bozóki, Z.1    Pogány, A.2    Szabó, G.3
  • 11
    • 0001055461 scopus 로고
    • Trace gas monitoring by laser-photoacoustic spectroscopy
    • Sigrist, M. W., "Trace gas monitoring by laser-photoacoustic spectroscopy," Infrared Phys. Techn. 36, 415-425 (1995).
    • (1995) Infrared Phys. Techn , vol.36 , pp. 415-425
    • Sigrist, M.W.1
  • 12
    • 61649103307 scopus 로고    scopus 로고
    • A compact ammonia detector with sub-ppb accuracy using near-infrared photoacoustic spectroscopy and preconcentration sampling
    • Pogány, A., Mohácsi, Á., Varga, A., Bozóki, Z., Galbács, Z., Horváth, L. and Szabó, G., "A compact ammonia detector with sub-ppb accuracy using near-infrared photoacoustic spectroscopy and preconcentration sampling," Environ. Sci. Technol. 43(3), 826-830 (2009).
    • (2009) Environ. Sci. Technol , vol.43 , Issue.3 , pp. 826-830
    • Pogány, A.1    Mohácsi, A.2    Varga, A.3    Bozóki, Z.4    Galbács, Z.5    Horváth, L.6    Szabó, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.