메뉴 건너뛰기




Volumn 46, Issue 1, 2011, Pages 1-37

Photoacoustic instruments for practical applications: Present, potentials, and future challenges

Author keywords

environmental monitoring; industrial applications; Photoacoustic spectroscopy

Indexed keywords

AUTOMATIC MEASUREMENTS; ENVIRONMENTAL MONITORING; FUTURE CHALLENGES; GAS CONCENTRATION; MEASUREMENT METHODS; PHOTOACOUSTIC INSTRUMENTS;

EID: 78651107348     PISSN: 05704928     EISSN: 1520569X     Source Type: Journal    
DOI: 10.1080/05704928.2010.520178     Document Type: Article
Times cited : (121)

References (91)
  • 2
    • 0025051578 scopus 로고
    • 2-laser photoa-coustic spectroscopy and other techniques
    • 2-laser photoa-coustic spectroscopy and other techniques. Rev. Sci. Instrum., 61 (7): 779-1807.
    • (1990) Rev. Sci. Instrum. , vol.61 , Issue.7 , pp. 779-1807
    • Meyer, P.L.1    Sigrist, M.W.2
  • 3
    • 0000052416 scopus 로고    scopus 로고
    • Photoacoustic spectroscopy in trace gas monitoring
    • Meyers, R.A., Ed. John Wiley & Sons: Chichester, UK
    • Harren, FJ.M., Cotti, G., Oomens, J., and Hekkert, S.L. (2000) Photoacoustic spectroscopy in trace gas monitoring. In Encyclopedia of Analytical Chemistry, Meyers, R.A., Ed. John Wiley & Sons: Chichester, UK, pp. 2203-2226.
    • (2000) Encyclopedia of Analytical Chemistry , pp. 2203-2226
    • Harren, F.J.M.1    Cotti, G.2    Oomens, J.3    Hekkert, S.L.4
  • 4
    • 34548692103 scopus 로고    scopus 로고
    • Photoacoustic gas analysis using interferometric cantilever microphone
    • Kuusela, T. and Kauppinen, J. (2007) Photoacoustic gas analysis using interferometric cantilever microphone. Appl. Spectros. Rev., 42: 443-474.
    • (2007) Appl. Spectros. Rev. , vol.42 , pp. 443-474
    • Kuusela, T.1    Kauppinen, J.2
  • 6
    • 0001489620 scopus 로고
    • Ontheproductionandreproductionof soundby light
    • Bell, A.G. (1880)Ontheproductionandreproductionof soundby light.Am. J. Sci., 20: 305-324.
    • (1880) Am J. Sci. , vol.20 , pp. 305-324
    • Bell, A.G.1
  • 7
    • 0000379490 scopus 로고
    • Upon the production of sound by radiant energy
    • Bell, A.G. (1881) Upon the production of sound by radiant energy. Phil. Mag., 11: 510-528.
    • (1881) Phil. Mag. , vol.11 , pp. 510-528
    • Bell, A.G.1
  • 8
    • 78651085725 scopus 로고
    • Ueber töne welche durch intermittirende bestrahlung eines gases entste-hen
    • Röntgen, W.C. (1880) Ueber töne, welche durch intermittirende bestrahlung eines gases entste-hen. Ann. Phys., 248 (1): 155-159.
    • (1880) Ann. Phys. , vol.248 , Issue.1 , pp. 155-159
    • Röntgen, W.C.1
  • 9
    • 0000309085 scopus 로고
    • Action of an intermittent beam of radiant heat upon gaseous matter
    • Tyndall, J. (1881) Action of an intermittent beam of radiant heat upon gaseous matter. Proc Roy. Soc., 31: 307-317.
    • (1881) Proc Roy. Soc. , vol.31 , pp. 307-317
    • Tyndall, J.1
  • 10
    • 0013543297 scopus 로고
    • On the conversion of radiant energy into sonorous vibrations
    • Preece, W.H. (1881) On the conversion of radiant energy into sonorous vibrations. Proc Roy. Soc., 31: 506-520.
    • (1881) Proc Roy. Soc. , vol.31 , pp. 506-520
    • Preece, W.H.1
  • 11
    • 0038930089 scopus 로고
    • Eine methode der gasanalyse beruhend auf der optisch-akustischen Tyndall-Röntgenerscheinung
    • Viegerov, M.L. (1938) Eine methode der gasanalyse, beruhend auf der optisch-akustischen Tyndall-Röntgenerscheinung. Dokl. Akad. Nauk SSSR, 19: 687-688.
    • (1938) Dokl. Akad. Nauk SSSR , vol.19 , pp. 687-688
    • Viegerov, M.L.1
  • 12
    • 84975571259 scopus 로고
    • The laser illuminated absorptivity spectrophone: A method formeasurementof weakabsorptivity ingases atlaser wavelengths
    • Kerr, E.L. and Atwood, J.G. (1968) The laser illuminated absorptivity spectrophone: A method formeasurementof weakabsorptivity ingases atlaser wavelengths. Appl. Optic., 7 (5): 915-922.
    • (1968) Appl. Optic. , vol.7 , Issue.5 , pp. 915-922
    • Kerr, E.L.1    Atwood, J.G.2
  • 13
    • 22144486488 scopus 로고
    • CO-laserphotoacousticspectroscopyof gasesandvapours for trace gas analysis
    • Bernegger, S. andSigrist,M.W. (1990)CO-laserphotoacousticspectroscopyof gasesandvapours for trace gas analysis. InfraredPhys., 30 (5): 375-429.
    • (1990) InfraredPhys. , vol.30 , Issue.5 , pp. 375-429
    • Bernegger, S.1    Sigrist, M.W.2
  • 14
    • 0036591954 scopus 로고    scopus 로고
    • Near-infrared diode laser based spectroscopic detection of ammonia: A comparative study of photoacoustic and direct optical absorption methods
    • Bozóki, Z., Mohácsi, Á., Szabó, G., Bor, Zs., Erdélyi, M., Chen, W., and Tittel, F.K. (2002) Near-infrared diode laser based spectroscopic detection of ammonia: A comparative study of photoacoustic and direct optical absorption methods. Appl. Spectros., 56 (6): 715-719.
    • (2002) Appl. Spectros. , vol.56 , Issue.6 , pp. 715-719
    • Bozóki, Z.1    Mohácsi, Á.2    Szabó, G.3    Bor, Zs.4    Erdélyi, M.5    Chen, W.6    Tittel, F.K.7
  • 15
    • 20444444392 scopus 로고    scopus 로고
    • Nd:YAG laser based photoacoustic detection of ozone; Comparison of pulsed and quasi continuous wave operation and field tests
    • Veres, A.H., Sarlós, F., Varga, A., Szabó, G., Bozóki, Z., Motika, G., and Gyapjas, J. (2005) Nd:YAG laser based photoacoustic detection of ozone; comparison of pulsed and quasi continuous wave operation and field tests. Spectros. Lett., 38: 377-388.
    • (2005) Spectros. Lett. , vol.38 , pp. 377-388
    • Veres, A.H.1    Sarlós, F.2    Varga, A.3    Szabó, G.4    Bozóki, Z.5    Motika, G.6    Gyapjas, J.7
  • 16
    • 84979222835 scopus 로고    scopus 로고
    • Available at [accessed]
    • LumaSense Technologies. Available at http://www.lumasense.dk/INNOVA-1303. gas-monito ring6.0.html [accessed].
    • LumaSense Technologies
  • 18
    • 0347617254 scopus 로고
    • Resonant photoacoustic detection of methane in nitrogen using a room temperature infrared light emitting diode
    • Chey, J.W., Sultan, P., and Gerritsen, H.J. (1987) Resonant photoacoustic detection of methane in nitrogen using a room temperature infrared light emitting diode. Appl. Optic., 26 (16): 3192-3194.
    • (1987) Appl. Optic. , vol.26 , Issue.16 , pp. 3192-3194
    • Chey, J.W.1    Sultan, P.2    Gerritsen, H.J.3
  • 19
    • 70350573470 scopus 로고    scopus 로고
    • Photoacoustic gas detection using a cantilever microphone and III-V LEDs
    • Kuusela, T., Peura, J., Matveev, B.A., Remennyy, M.A., and Stus, N.M. (2009) Photoacoustic gas detection using a cantilever microphone and III-V LEDs. Vib. Spectros., 51: 289-293.
    • (2009) Vib. Spectros. , vol.51 , pp. 289-293
    • Kuusela, T.1    Peura, J.2    Matveev, B.A.3    Remennyy, M.A.4    Stus, N.M.5
  • 20
    • 0000789869 scopus 로고
    • New developments in CO2-laser photoacoustic monitoring of trace gases
    • Thöny, A. and Sigrist, M. W. (1995) New developments in CO2-laser photoacoustic monitoring of trace gases. InfraredPhys. Tech., 36: 585-615.
    • (1995) InfraredPhys. Tech. , vol.36 , pp. 585-615
    • Thöny, A.1    Sigrist, M.W.2
  • 22
    • 78651106830 scopus 로고    scopus 로고
    • Available at
    • Pranalytica Inc Available at http://www.pranalytica.com
    • Pranalytica Inc
  • 23
    • 78651111940 scopus 로고    scopus 로고
    • Available at
    • Omnisens. Available at http://www.omnisens.ch
    • Omnisens.
  • 24
    • 0032072262 scopus 로고    scopus 로고
    • Multicomponent trace-gas analysis by three intracavity photoacoustic cells in a CO laser: Observation of anaerobic and postanaerobic emission of acetaldehyde and ethanol in cherry tomatoes
    • Bijnen, F.G.C., Zuckermann, H., Harren, FJ.M., and Reuss, J. (1998) Multicomponent trace-gas analysis by three intracavity photoacoustic cells in a CO laser: Observation of anaerobic and postanaerobic emission of acetaldehyde and ethanol in cherry tomatoes. Appl. Optic., 37 (15): 3345-3353.
    • (1998) Appl. Optic. , vol.37 , Issue.15 , pp. 3345-3353
    • Bijnen, F.G.C.1    Zuckermann, H.2    Harren, F.J.M.3    Reuss, J.4
  • 26
    • 33749032414 scopus 로고    scopus 로고
    • Multi-hydrogenated compounds monitoring in optical fibre manufacturing processes by photoacoustic spectroscopy
    • Besson, J.-P., Schilt, S., Sauser, F, Rochat, E., Hamel, P, Sandoz, F., Nikles, M., and Thevenaz, L. (2006b) Multi-hydrogenated compounds monitoring in optical fibre manufacturing processes by photoacoustic spectroscopy. Appl. Phys. B, 85: 343-348.
    • (2006) Appl. Phys. B , vol.85 , pp. 343-348
    • Besson, J.-P.1    Schilt, S.2    Sauser, F.3    Rochat, E.4    Hamel, P.5    Sandoz, F.6    Nikles, M.7    Thevenaz, L.8
  • 27
    • 33749034478 scopus 로고    scopus 로고
    • Ammonia trace measurements at ppb level based on near-IR photoacoustic spectroscopy
    • Besson, J.-P., Schilt S., Rochat, E., and Thevenaz, L. (2006c) Ammonia trace measurements at ppb level based on near-IR photoacoustic spectroscopy. Appl. Phys. B, 85: 323-328.
    • (2006) Appl. Phys. B , vol.85 , pp. 323-328
    • Besson, J.-P.1    Schilt, S.2    Rochat, E.3    Thevenaz, L.4
  • 29
    • 34250798476 scopus 로고    scopus 로고
    • A novel apparatus based on a photoacoustic gas detection system for measuring permeation parameters of polymer samples
    • Filus, Z., Ajtai, T., Horváth, Z.L., Bozóki, Z., Pap, G., Nagy, T., Katona, T., and Szabó, G. (2007) A novel apparatus based on a photoacoustic gas detection system for measuring permeation parameters of polymer samples. Polymer Test., 26: 606-613.
    • (2007) Polymer Test. , vol.26 , pp. 606-613
    • Filus, Z.1    Ajtai, T.2    Horváth, Z.L.3    Bozóki, Z.4    Pap, G.5    Nagy, T.6    Katona, T.7    Szabó, G.8
  • 30
    • 0030212088 scopus 로고    scopus 로고
    • Photoacoustic soot sensor for in-situ blackcarbonmonitoring
    • Petzold, A. and Niessner, R. (1996) Photoacoustic soot sensor for in-situ blackcarbonmonitoring. Appl. Phys. B, 63: 191-197.
    • (1996) Appl. Phys. B , vol.63 , pp. 191-197
    • Petzold, A.1    Niessner, R.2
  • 31
    • 0033180873 scopus 로고    scopus 로고
    • Photoacoustic spec-trometer for measuring light absorption by aerosol: Instrument description
    • Arnott, W.P, Moosmüller, H., Rogers, C.F., Jin, T., and Bruch R. (1999) Photoacoustic spec-trometer for measuring light absorption by aerosol: Instrument description. Atmos. Environ., 33: 2845-2852.
    • (1999) Atmos. Environ. , vol.33 , pp. 2845-2852
    • Arnott, W.P.1    Moosmüller, H.2    Rogers, C.F.3    Jin, T.4    Bruch, R.5
  • 32
    • 0033632926 scopus 로고    scopus 로고
    • High stability external cavity diodelaser system for photoacoustic gas detection
    • Mohácsi, Á., Szakáll, M., Bozóki, Z., Szabó, G., and Bor, Zs. (2000) High stability external cavity diodelaser system for photoacoustic gas detection. Laser Phys., 10 (1): 1-4.
    • (2000) Laser Phys. , vol.10 , Issue.1 , pp. 1-4
    • Mohácsi, Á.1    Szakáll, M.2    Bozóki, Z.3    Szabó, G.4    Bor, Zs.5
  • 33
    • 33750690688 scopus 로고    scopus 로고
    • Photoacoustic spectroscopy with quantum cascade lasers for trace gas detection
    • Elia, A., di Franco, C, Lugara, PM., and Scamarcio, G. (2006) Photoacoustic spectroscopy with quantum cascade lasers for trace gas detection. Sensors, 6: 1411-1419.
    • (2006) Sensors , vol.6 , pp. 1411-1419
    • Elia, A.1    Di Franco, C.2    Lugara, P.M.3    Scamarcio, G.4
  • 35
    • 51849142140 scopus 로고    scopus 로고
    • Ammonia monitoring at ppb level using photoacoustic spectroscopy for environmental application
    • Huszár, H., Pogány, A., Bozóki, Z., Mohácsi, Á., Horváth, L., and Szabó, G. (2008) Ammonia monitoring at ppb level using photoacoustic spectroscopy for environmental application. Sensor. Actuator. B Chem., 134: 1027-1033.
    • (2008) Sensor. Actuator. B Chem. , vol.134 , pp. 1027-1033
    • Huszár, H.1    Pogány, A.2    Bozóki, Z.3    Mohácsi, Á.4    Horváth, L.5    Szabó, G.6
  • 36
    • 0141599846 scopus 로고    scopus 로고
    • Characterization of a mobile photoacoustic sensor for atmospheric black carbon monitoring
    • Krämer, L., Bozóki, Z., and Niessner, R. (2001) Characterization of a mobile photoacoustic sensor for atmospheric black carbon monitoring. Anal. Sci., 17: 563-566.
    • (2001) Anal. Sci. , vol.17 , pp. 563-566
    • Krämer, L.1    Bozóki, Z.2    Niessner, R.3
  • 37
    • 33747130723 scopus 로고    scopus 로고
    • Optical properties and mineralogical composition of different Saharan mineral dust samples: A laboratory study
    • Linke, C, Mohler, O., Veres, A.H., Mohácsi, Á., Bozóki, Z., Szabó, G., and Schnaiter, M. (2006) Optical properties and mineralogical composition of different Saharan mineral dust samples: A laboratory study. Atmos. Chem. Phys., 6: 3315-3323. (Pubitemid 44221574)
    • (2006) Atmospheric Chemistry and Physics , vol.6 , Issue.11 , pp. 3315-3323
    • Linke, C.1    Mohler, O.2    Veres, A.3    Mohacsi, A.4    Bozoki, Z.5    Szabo, G.6    Schnaiter, M.7
  • 39
    • 77957364994 scopus 로고    scopus 로고
    • Introduction of a novel multi-wavelength photoacoustic spectrometer for the measurement of the UV-VIS-NIR spectral absorption coefficient of atmospheric aerosols
    • Ajtai, T., Filep, Á., Schnaiter, M., Linke, C, Vragel, M., Bozóki, Z., Szabó, G., and Leisner, T. (2010) Introduction of a novel multi-wavelength photoacoustic spectrometer for the measurement of the UV-VIS-NIR spectral absorption coefficient of atmospheric aerosols. J. Aerosol Sci., 41: 1020-1029.
    • (2010) J. Aerosol Sci. , vol.41 , pp. 1020-1029
    • Ajtai, T.1    Filep, Á.2    Schnaiter, M.3    Linke, C.4    Vragel, M.5    Bozóki, Z.6    Szabó, G.7    Leisner, T.8
  • 41
    • 79955992909 scopus 로고    scopus 로고
    • Photoacoustic trace gas detection of ethane using a continuously tunable continuous-wave optical parametric oscillator based on periodically poled lithium niobate
    • van Herpen, M.MJ.W., Lim, S., Bisson, S.E., and Harren, FJ.M. (2002) Photoacoustic trace gas detection of ethane using a continuously tunable, continuous-wave optical parametric oscillator based on periodically poled lithium niobate. Appl. Phys. Lett., 81 (7): 1157-1159.
    • (2002) Appl. Phys. Lett. , vol.81 , Issue.7 , pp. 1157-1159
    • Van Herpen, M.M.J.W.1    Lim, S.2    Bisson, S.E.3    Harren, F.J.M.4
  • 42
    • 0031334421 scopus 로고    scopus 로고
    • Optical parametric oscillator based difference frequency laser source for photoacoustic trace gas spectroscopy in the 3-μ mid-IR range
    • Bohren, A. and Sigrist, M.W. (1997) Optical parametric oscillator based difference frequency laser source for photoacoustic trace gas spectroscopy in the 3-μ mid-IR range. Infrared Phys. Tech., 38: 423-435.
    • (1997) Infrared Phys. Tech. , vol.38 , pp. 423-435
    • Bohren, A.1    Sigrist, M.W.2
  • 43
    • 33749011449 scopus 로고    scopus 로고
    • Photoacoustic spectroscopy with tunable laser radiation at the parts per billion level
    • Angelmahr, M., Miklós, A., and Hess, P. (2006) Photoacoustic spectroscopy with tunable laser radiation at the parts per billion level. Appl. Phys. B, 85: 285-288.
    • (2006) Appl. Phys. B , vol.85 , pp. 285-288
    • Angelmahr, M.1    Miklós, A.2    Hess, P.3
  • 44
    • 67651002348 scopus 로고    scopus 로고
    • Modulated versus pulsed resonant photoa-coustics in trace gas detection
    • Bartlome, R., Kaucikas, M., and Sigrist, M.W. (2009) Modulated versus pulsed resonant photoa-coustics in trace gas detection. Appl. Phys. B, 96: 561-566.
    • (2009) Appl. Phys. B , vol.96 , pp. 561-566
    • Bartlome, R.1    Kaucikas, M.2    Sigrist, M.W.3
  • 45
    • 0009696504 scopus 로고    scopus 로고
    • Low power quantum-cascade laser photoacoustic spectrometer for trace-gas monitoring
    • Nägele, M., Hofstetter, D., Faist, J., and Sigrist, M.W. (2001) Low power quantum-cascade laser photoacoustic spectrometer for trace-gas monitoring. Anal. Sci., 117: 497-499.
    • (2001) Anal. Sci. , vol.117 , pp. 497-499
    • Nägele, M.1    Hofstetter, D.2    Faist, J.3    Sigrist, M.W.4
  • 46
    • 33746225274 scopus 로고    scopus 로고
    • On the pressure dependent sensitivity of a photoacoustic water vapor detector using a novel modulation method
    • Szakáll, M., Huszár, H., Bozóki, Z., and Szabó, G. (2006) On the pressure dependent sensitivity of a photoacoustic water vapor detector using a novel modulation method. Infrared Phys. Tech., 48: 192-201.
    • (2006) Infrared Phys. Tech. , vol.48 , pp. 192-201
    • Szakáll, M.1    Huszár, H.2    Bozóki, Z.3    Szabó, G.4
  • 47
    • 33646687338 scopus 로고    scopus 로고
    • Wavelength modulation photoacoustic spectroscopy: Theo-retical description and experimental results
    • Schilt, S. and Thevenaz, L. (2006) Wavelength modulation photoacoustic spectroscopy: Theo-retical description and experimental results. Infrared Phys. Tech., 48: 154-162.
    • (2006) Infrared Phys. Tech. , vol.48 , pp. 154-162
    • Schilt, S.1    Thevenaz, L.2
  • 48
    • 0001676996 scopus 로고    scopus 로고
    • Sensitive measurement of adsorption dynamics with nonresonant gas phase photoacoustics
    • Henningsen, J. and Melander, N. (1997) Sensitive measurement of adsorption dynamics with nonresonant gas phase photoacoustics. Appl. Optic., 36: 7037-7045.
    • (1997) Appl. Optic. , vol.36 , pp. 7037-7045
    • Henningsen, J.1    Melander, N.2
  • 49
    • 0035305186 scopus 로고    scopus 로고
    • Application of acoustic resonators in photoacoustic trace gas analysis and metrology
    • DOI 10.1063/1.1353198
    • Miklós, A., Hess, P, and Bozóki, Z. (2001) Application of acoustic resonators in photoacoustic trace gas analysis and metrology. Rev. Sci. Instrum., 72 (4): 1937-1955. (Pubitemid 33606044)
    • (2001) Review of Scientific Instruments , vol.72 , Issue.4 , pp. 1937-1955
    • Miklos, A.1    Hess, P.2    Bozoki, Z.3
  • 50
    • 9644287874 scopus 로고    scopus 로고
    • Ammoniamonitoring at trace level using photoacoustic spectroscopy in industrial and environmental applications
    • Schilt, S., Thévenaz, L., Niklès, M., Emmenegger, L., andHüglinC. (2004) Ammoniamonitoring at trace level using photoacoustic spectroscopy in industrial and environmental applications. Spectrochim. Acta A, 60: 3259-3268.
    • (2004) Spectrochim. Acta A , vol.60 , pp. 3259-3268
    • Schilt, S.1    Thévenaz, L.2    Niklès, M.3    Andhüglinc, E.L.4
  • 51
    • 0024620012 scopus 로고
    • Windowless resonant acoustic chamber for laser-photoacoustic applications
    • Miklós, A. and Lorincz, A. (1989) Windowless resonant acoustic chamber for laser-photoacoustic applications. Appl. Phys. B, 48: 213-218.
    • (1989) Appl. Phys. B , vol.48 , pp. 213-218
    • Miklós, A.1    Lorincz, A.2
  • 52
  • 53
    • 10444256234 scopus 로고    scopus 로고
    • Ammonia detection by useof quartz-enhancedphotoacous-tic spectroscopy with near-IR telecommunication diode laser
    • Kosterev,A.A. andTittel, F.K. (2004) Ammonia detection by useof quartz-enhancedphotoacous-tic spectroscopy with near-IR telecommunication diode laser. Appl. Optic., 43 (33): 6213-6217.
    • (2004) Appl. Optic. , vol.43 , Issue.33 , pp. 6213-6217
    • Kosterev, A.A.1    Tittel, F.K.2
  • 56
    • 84975595219 scopus 로고
    • Photoacoustic measurement of am-monia in the atmosphere: Influence of water vapor and carbon dioxide
    • Rooth R.A., Verhange, AJ.L., and Wouters, L.W. (1990) Photoacoustic measurement of am-monia in the atmosphere: influence of water vapor and carbon dioxide. Appl. Optics., 29 (25): 3643-3652.
    • (1990) Appl. Optics. , vol.29 , Issue.25 , pp. 3643-3652
    • Rooth, R.A.1    Verhange, A.J.L.2    Wouters, L.W.3
  • 57
    • 84975625022 scopus 로고
    • Cell coatings to minimize sample (NH 3 and N2H4) adsorption for low-level photoacoustic detection
    • Beck, S.M. (1985) Cell coatings to minimize sample (NH 3 and N2H4) adsorption for low-level photoacoustic detection. Appl. Optic., 24(12): 1761-1763.
    • (1985) Appl. Optic. , vol.24 , Issue.12 , pp. 1761-1763
    • Beck, S.M.1
  • 59
    • 0034194285 scopus 로고    scopus 로고
    • Screening of pentachlorophenol-contaminated wood by thermodesorption sampling and photoacoustic detection
    • Beck, H.A., Bozóki, Z., and Niessner, R. (2000) Screening of pentachlorophenol-contaminated wood by thermodesorption sampling and photoacoustic detection. Anal. Chem., 72: 2171-2176.
    • (2000) Anal. Chem. , vol.72 , pp. 2171-2176
    • Beck, H.A.1    Bozóki, Z.2    Niessner, R.3
  • 61
    • 77953137885 scopus 로고    scopus 로고
    • Afullyopenedphotoacousticresonator based system for fast response gas concentration measurements
    • Bozóki, Z., Szabó, A., Mohácsi, Á., andSzabó, G. (2010)Afullyopenedphotoacousticresonator based system for fast response gas concentration measurements. Sensor. Actuator. B Chem., 147(1): 206-212.
    • (2010) Sensor. Actuator. B Chem. , vol.147 , Issue.1 , pp. 206-212
    • Bozóki, Z.1    Szabó, A.2    Mohácsi, Á.3    Szabó, G.4
  • 62
    • 22144439087 scopus 로고    scopus 로고
    • Selective differential photoacoustic method for trace gas analysis
    • Uotila, J., Koskinen, V., and Kaupinen, J. (2005) Selective differential photoacoustic method for trace gas analysis. Vib. Spectros., 38: 3-9.
    • (2005) Vib. Spectros. , vol.38 , pp. 3-9
    • Uotila, J.1    Koskinen, V.2    Kaupinen, J.3
  • 63
    • 33749025573 scopus 로고    scopus 로고
    • Influence of molecular relaxation dynamics on quartz-enhanced photoacoustic detection of CO2 at a; = 2 μ m
    • Wysocki, G., Kosterev, A.A., and Tittel, F.K. (2006) Influence of molecular relaxation dynamics on quartz-enhanced photoacoustic detection of CO2 at a; = 2 μ m. Appl. Phys. B, 85: 301-306.
    • (2006) Appl. Phys. B , vol.85 , pp. 301-306
    • Wysocki, G.1    Kosterev, A.A.2    Tittel, F.K.3
  • 65
    • 39149139015 scopus 로고    scopus 로고
    • Molecular relaxation effects in hydrogen chloride photoacoustic detection
    • Besson, J.-P., Schilt, S., and Thevenaz, L. (2008) Molecular relaxation effects in hydrogen chloride photoacoustic detection. Appl. Phys. B, 90: 191-196.
    • (2008) Appl. Phys. B , vol.90 , pp. 191-196
    • Besson, J.-P.1    Schilt, S.2    Thevenaz, L.3
  • 66
    • 34748900560 scopus 로고    scopus 로고
    • On the temperature dependent charac-teristics of a photoacoustic water vapor detector for airborne application
    • Szakáll, M., Csikós, J., Bozóki, Z., and Szabó, G. (2007) On the temperature dependent charac-teristics of a photoacoustic water vapor detector for airborne application. Infrared Phys. Tech., 51: 113-121.
    • (2007) Infrared Phys. Tech. , vol.51 , pp. 113-121
    • Szakáll, M.1    Csikós, J.2    Bozóki, Z.3    Szabó, G.4
  • 67
    • 0346685331 scopus 로고    scopus 로고
    • Mobile laser spectrometer with novel resonant multipass photoacoustic cell for trace-gas sensing
    • Nägele, M. and Sigrist, M.W. (2000) Mobile laser spectrometer with novel resonant multipass photoacoustic cell for trace-gas sensing. Appl. Phys. B, 70: 895-901.
    • (2000) Appl. Phys. B , vol.70 , pp. 895-901
    • Nägele, M.1    Sigrist, M.W.2
  • 68
    • 0041381211 scopus 로고    scopus 로고
    • Fiber-amplifier-enhancedphotoacoustic spectroscopy with near-infrared tunable diode lasers
    • Webber, M.E., Pushkarsky, M., and Patel, C.K.N. (2003) Fiber-amplifier-enhancedphotoacoustic spectroscopy with near-infrared tunable diode lasers. Appl. Optic., 42(12) 2119-2126.
    • (2003) Appl. Optic. , vol.42 , Issue.12 , pp. 2119-2126
    • Webber, M.E.1    Pushkarsky, M.2    Patel, C.K.N.3
  • 69
    • 0018907640 scopus 로고
    • Integrative technique for detection of atmospheric ammonia
    • McClenny, W.A. and Bennett, C.A. (1980) Integrative technique for detection of atmospheric ammonia. Atmos. Environ., 14(6): 641-645.
    • (1980) Atmos. Environ. , vol.14 , Issue.6 , pp. 641-645
    • McClenny, W.A.1    Bennett, C.A.2
  • 70
    • 61649103307 scopus 로고    scopus 로고
    • A compact ammonia detector with sub-ppb accuracy using near-infrared photoacoustic spec-troscopy and preconcentration sampling
    • Pogány, A., Mohácsi, Á., Varga, A., Bozóki, Z., Galbács, Z., Horváth, L., and Szabó, G. (2009) A compact ammonia detector with sub-ppb accuracy using near-infrared photoacoustic spec-troscopy and preconcentration sampling. Environ. Sci. Tech., 43: 826-830.
    • (2009) Environ. Sci. Tech. , vol.43 , pp. 826-830
    • Pogány, A.1    Mohácsi, Á.2    Varga, A.3    Bozóki, Z.4    Galbács, Z.5    Horváth, L.6    Szabó, G.7
  • 71
    • 63049122248 scopus 로고    scopus 로고
    • An automated analyzer to measure surface-atmosphere exchange fluxes of water soluble inorganic aerosol compounds and reactive trace gases
    • Thomas, R.M., Trebs, I., Otjes, R., Jongejan, PA.C., ten Brink, H., Phillips, G., Kortner, M., Meixner, F. X., and Nemitz, E. (2009) An automated analyzer to measure surface-atmosphere exchange fluxes of water soluble inorganic aerosol compounds and reactive trace gases. Environ. Sci. Tech., 43(5): 1412-1418.
    • (2009) Environ. Sci. Tech. , vol.43 , Issue.5 , pp. 1412-1418
    • Thomas, R.M.1    Trebs, I.2    Otjes, R.3    Jongejan, P.A.C.4    Ten Brink, H.5    Phillips, G.6    Kortner, M.7    Meixner, F.X.8    Nemitz, E.9
  • 73
    • 77949273864 scopus 로고    scopus 로고
    • Evaluation of a diode laser based photoacoustic instrument combined with preconcentration sampling for measuring surface-atmosphere exchange of am-monia with the aerodynamic gradient method
    • Pogány, A., Mohácsi, Á., Jones, S.K., Nemitz, E., Varga, A., Bozóki, Z., Galbács, Z., Weidinger, T., Horváth, L., and Szabó, G. (2010) Evaluation of a diode laser based photoacoustic instrument combined with preconcentration sampling for measuring surface-atmosphere exchange of am-monia with the aerodynamic gradient method. Atmos. Environ., 44: 1490-1496.
    • (2010) Atmos. Environ. , vol.44 , pp. 1490-1496
    • Pogány, A.1    Mohácsi, Á.2    Jones, S.K.3    Nemitz, E.4    Varga, A.5    Bozóki, Z.6    Galbács, Z.7    Weidinger, T.8    Horváth, L.9    Szabó, G.10
  • 74
    • 20744444555 scopus 로고    scopus 로고
    • Inter-comparison of laser photoacoustic spectroscopy and gas chromatography techniques for measurement of ethene in the atmosphere
    • Kuster, W.C., Harren, FJ.M., and de Gouw, J.A. (2005) Inter-comparison of laser photoacoustic spectroscopy and gas chromatography techniques for measurement of ethene in the atmosphere. Environ. Sci. Tech., 39: 4581-4585.
    • (2005) Environ. Sci. Tech. , vol.39 , pp. 4581-4585
    • Kuster, W.C.1    Harren, F.J.M.2    De Gouw, J.A.3
  • 75
    • 78651097583 scopus 로고    scopus 로고
    • Ozone concentration monitoring photoacoustic system based on a frequency quadrupled Nd:YAG laser
    • Ajtai, T., Filep, Á., Varga, A., Motika, G., Bozóki, Z., and Szabó, G. (2010) Ozone concentration monitoring photoacoustic system based on a frequency quadrupled Nd:YAG laser. Appl. Phys. B., 101: 403-409.
    • (2010) Appl. Phys. B. , vol.101 , pp. 403-409
    • Ajtai, T.1    Filep, Á.2    Varga, A.3    Motika, G.4    Bozóki, Z.5    Szabó, G.6
  • 77
    • 11844260014 scopus 로고    scopus 로고
    • Towards aerosol light absorption measurements with a 7-wavelength aethalometer: Evaluation with a photoacoustic instrument and a 3-wavelength nephelometer
    • Arnott, W.P, Hamasha, K., Moosmüller, H., Sheridan, P.J., and Ogren, J.A. (2005) Towards aerosol light absorption measurements with a 7-wavelength aethalometer: Evaluation with a photoacoustic instrument and a 3-wavelength nephelometer. Aerosol Sci. Tech., 39: 17-29.
    • (2005) Aerosol Sci. Tech. , vol.39 , pp. 17-29
    • Arnott, W.P.1    Hamasha, K.2    Moosmüller, H.3    Sheridan, P.J.4    Ogren, J.A.5
  • 78
    • 3843127546 scopus 로고    scopus 로고
    • Diode laser based photoa-coustic water vapour detection system for atmospheric research
    • Szakáll, M., Bozóki, Z., Mohácsi, Á., Varga, A., and Szabó, G. (2004) Diode laser based photoa-coustic water vapour detection system for atmospheric research. Appl. Spectros., 58(7): 792-798.
    • (2004) Appl. Spectros. , vol.58 , Issue.7 , pp. 792-798
    • Szakáll, M.1    Bozóki, Z.2    Mohácsi, Á.3    Varga, A.4    Szabó, G.5
  • 79
    • 0035892796 scopus 로고    scopus 로고
    • Evaluation of a photoacoustic detector for water vapor measurements under simulated tropo-spheric/lower stratospheric conditions
    • Szakáll, M., Bozóki, Z., Kraemer, M., Spelten, N., Moehler, O., and Schurath, U. (2001) Evaluation of a photoacoustic detector for water vapor measurements under simulated tropo-spheric/lower stratospheric conditions. Environ. Sci. Tech., 35: 4881-4885.
    • (2001) Environ. Sci. Tech. , vol.35 , pp. 4881-4885
    • Szakáll, M.1    Bozóki, Z.2    Kraemer, M.3    Spelten, N.4    Moehler, O.5    Schurath, U.6
  • 80
    • 0035888371 scopus 로고    scopus 로고
    • Direct diffusion sampling-based photoacoustic cell for in situ and on-line monitoring of benzene and toluene concentrations in water
    • Mohácsi, Á., Bozóki, Z., and Niessner, R. (2001) Direct diffusion sampling-based photoacoustic cell for in situ and on-line monitoring of benzene and toluene concentrations in water. Sensor. Actuator. B Chem., 79: 127-131.
    • (2001) Sensor. Actuator. B Chem. , vol.79 , pp. 127-131
    • Mohácsi, Á.1    Bozóki, Z.2    Niessner, R.3
  • 81
    • 9244220938 scopus 로고    scopus 로고
    • Multi-gas sensing based on photoacoustic spectroscopy using tunable laser diodes
    • Besson, J.-P., Schilt, S., and Thevenaz, L. (2004) Multi-gas sensing based on photoacoustic spectroscopy using tunable laser diodes. Spectrochim. Acta A, 60: 3449-3456.
    • (2004) Spectrochim. Acta A , vol.60 , pp. 3449-3456
    • Besson, J.-P.1    Schilt, S.2    Thevenaz, L.3
  • 82
    • 33748903369 scopus 로고    scopus 로고
    • Combination of a photoacoustic detector with a diffusion sampler for the measurement of water vapor concentration in ethylene glycols for the natural gas industry
    • Huszár, H., Bozóki, Z., Mohácsi, Á., Szabó, G., Puskás, S., and Tamás, J. (2006) Combination of a photoacoustic detector with a diffusion sampler for the measurement of water vapor concentration in ethylene glycols for the natural gas industry. Sensor. Actuator. B Chem., 119: 600-607.
    • (2006) Sensor. Actuator. B Chem. , vol.119 , pp. 600-607
    • Huszár, H.1    Bozóki, Z.2    Mohácsi, Á.3    Szabó, G.4    Puskás, S.5    Tamás, J.6
  • 84
    • 30444440587 scopus 로고    scopus 로고
    • Near-infrared laser photoacoustic detection of methane: The impact of molecular relaxation
    • Schilt, S., Besson, J.-P., and Thevenaz, L. (2006) Near-infrared laser photoacoustic detection of methane: The impact of molecular relaxation. Appl. Phys. B, 82: 319-329.
    • (2006) Appl. Phys. B , vol.82 , pp. 319-329
    • Schilt, S.1    Besson, J.-P.2    Thevenaz, L.3
  • 85
    • 0001092650 scopus 로고    scopus 로고
    • Photoacoustic spectroscopy with quantum cascade distributed-feedback lasers
    • Hofstetter, D., Beck, M., Faist, J., Nägele, M., and Sigrist, M.W. (2001) Photoacoustic spectroscopy with quantum cascade distributed-feedback lasers. Optic Lett., 26(12): 887-889. (Pubitemid 33693605)
    • (2001) Optics Letters , vol.26 , Issue.12 , pp. 887-889
    • Hofstetter, D.1    Beck, M.2    Faist, J.3    Nagele, M.4    Sigrist, M.W.5
  • 87
    • 2642578397 scopus 로고    scopus 로고
    • Photoacoustic detection of ozone using a quantum cascade laser
    • da Silva, M.G., Vargas, H., Miklós, A., and Hess, P. (2004) Photoacoustic detection of ozone using a quantum cascade laser. Appl. Phys. B, 78: 677-680.
    • (2004) Appl. Phys. B , vol.78 , pp. 677-680
    • Da Silva, M.G.1    Vargas, H.2    Miklós, A.3    Hess, P.4
  • 88
    • 33645732076 scopus 로고    scopus 로고
    • Sub-part-per-billion monitoring of nitric oxide by use of wavelength modulation spectroscopy in combination with a thermoelec-trically cooled, continuous-wave quantum cascade laser
    • Moeskops, B.W.M., Cristescu, S.M., and Harren, FJ.M. (2006) Sub-part-per-billion monitoring of nitric oxide by use of wavelength modulation spectroscopy in combination with a thermoelec-trically cooled, continuous-wave quantum cascade laser. Optic Lett., 31: 823-825.
    • (2006) Optic Lett. , vol.31 , pp. 823-825
    • Moeskops, B.W.M.1    Cristescu, S.M.2    Harren, F.J.M.3
  • 89
    • 0039842829 scopus 로고    scopus 로고
    • A high sensitivity near-infrared tunable-diode-laser-based photoacoustic water-vapour-detection system for automated operation
    • Bozóki, Z., Schneider, J., Gingl, Z., Mohácsi, Á., Szakáll, M., Bor, Zs., and Szabó, G. (1999) A high sensitivity, near-infrared tunable-diode-laser-based photoacoustic water-vapour-detection system for automated operation. Meas. Sci Technol., 10: 999-1003.
    • (1999) Meas. Sci Technol. , vol.10 , pp. 999-1003
    • Bozóki, Z.1    Schneider, J.2    Gingl, Z.3    Mohácsi, Á.4    Szakáll, M.5    Bor, Zs.6    Szabó, G.7
  • 90
    • 7544249918 scopus 로고    scopus 로고
    • Development and characterization of a mobile photoacoustic sensor for on-line so at emission monitoring in diesel exhaust gas
    • Beck, H.A., Niessner, R., and Haisch, C. (2003) Development and characterization of a mobile photoacoustic sensor for on-line so at emission monitoring in diesel exhaust gas. Anal. Bioanal. Chem., 375: 1136-1143.
    • (2003) Anal. Bioanal. Chem. , vol.375 , pp. 1136-1143
    • Beck, H.A.1    Niessner, R.2    Haisch, C.3
  • 91
    • 33749035471 scopus 로고    scopus 로고
    • Impact of humidity on quartz-enhanced photoacoustic spectroscopy based detection of HCN
    • Kostcrev, A.A., Mosely, T.S., and Tittel, F.K. (2006) Impact of humidity on quartz-enhanced photoacoustic spectroscopy based detection of HCN. Appl. Phys. B, 85: 295-300.
    • (2006) Appl. Phys. B , vol.85 , pp. 295-300
    • Kostcrev, A.A.1    Mosely, T.S.2    Tittel, F.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.