메뉴 건너뛰기




Volumn 39, Issue 5, 2012, Pages 2820-2825

Evaluation of hybrid depth scanning for carbon-ion radiotherapy

Author keywords

carbon therapy; depth scan technique

Indexed keywords

CARBON; ION BEAMS; NUCLEAR REACTIONS; RADIOTHERAPY; SCANNING;

EID: 84861601600     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4705357     Document Type: Article
Times cited : (68)

References (18)
  • 3
  • 5
    • 84863136482 scopus 로고    scopus 로고
    • The cancer treatment system at Hyogo Ion Beam Medical Center (HIBMC)
    • Y. Hishikawa, The cancer treatment system at Hyogo Ion Beam Medical Center (HIBMC)., J. Jpn. Soc. Ther. Radiat. Oncol. 14, 73-77 (2002).
    • (2002) J. Jpn. Soc. Ther. Radiat. Oncol. , vol.14 , pp. 73-77
    • Hishikawa, Y.1
  • 6
    • 84861648268 scopus 로고    scopus 로고
    • Carbon ion radiotherapy project at Gunma University
    • (Gunma, Japan)
    • T. Ohno, Carbon ion radiotherapy project at Gunma University., 49th PTCOG Meeting (Gunma, Japan, 2010).
    • (2010) 49th PTCOG Meeting
    • Ohno, T.1
  • 7
    • 0032732178 scopus 로고    scopus 로고
    • Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy
    • DOI 10.1088/0031-9155/44/11/306, PII S0031915599035290
    • U. Weber and G. Kraft, Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy., Phys. Med. Biol. 44, 2765-2775 (1999). 10.1088/0031-9155/44/11/306 (Pubitemid 29529358)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.11 , pp. 2765-2775
    • Weber, U.1    Kraft, G.2
  • 9
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4-A simulation toolkit
    • 10.1016/S0168-9002(03)01368-8
    • S. Agostinelli, GEANT4-A simulation toolkit., Nucl. Instrum. Methods Phys. Res. A 506, 250-303 (2003). 10.1016/S0168-9002(03)01368-8
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 11
    • 34547493638 scopus 로고    scopus 로고
    • Optimization for fast-scanning irradiation in particle therapy
    • DOI 10.1118/1.2754058
    • T. Inaniwa, T. Furukawa, T. Tomitani, S. Sato, K. Noda, and T. Kanai, Optimization for fast-scanning irradiation in particle therapy., Med. Phys. 34, 3302-3311 (2007). 10.1118/1.2754058 (Pubitemid 47175797)
    • (2007) Medical Physics , vol.34 , Issue.8 , pp. 3302-3311
    • Inaniwa, T.1    Furukawa, T.2    Tomitani, T.3    Sato, S.4    Noda, K.5    Kanai, T.6
  • 13
    • 67649616700 scopus 로고    scopus 로고
    • Field-size effect of physical doses in carbon-ion scanning using range shifter plates
    • 10.1118/1.3140586
    • T. Inaniwa, T. Furukawa, A. Nagano, S. Sato, S. Saotome, K. Noda, and T. Kanai, Field-size effect of physical doses in carbon-ion scanning using range shifter plates., Med. Phys. 36, 2889-2897 (2009). 10.1118/1.3140586
    • (2009) Med. Phys. , vol.36 , pp. 2889-2897
    • Inaniwa, T.1    Furukawa, T.2    Nagano, A.3    Sato, S.4    Saotome, S.5    Noda, K.6    Kanai, T.7
  • 14
    • 79952948045 scopus 로고    scopus 로고
    • Optimization algorithm for overlapping-field plans of scanned ion beam therapy with reduced sensitivity to range and setup uncertainties
    • 10.1088/0031-9155/56/6/009
    • T. Inaniwa, N. Kanematsu, T. Furukawa, and K. Noda, Optimization algorithm for overlapping-field plans of scanned ion beam therapy with reduced sensitivity to range and setup uncertainties., Phys. Med. Biol. 56, 1653-1669 (2011). 10.1088/0031-9155/56/6/009
    • (2011) Phys. Med. Biol. , vol.56 , pp. 1653-1669
    • Inaniwa, T.1    Kanematsu, N.2    Furukawa, T.3    Noda, K.4
  • 15
    • 79961085493 scopus 로고    scopus 로고
    • A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage
    • 10.1088/0031-9155/56/15/008
    • T. Inaniwa, N. Kanematsu, T. Furukawa, and A. Hasegawa, A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage., Phys. Med. Biol. 56, 4749-4770 (2011). 10.1088/0031-9155/56/ 15/008
    • (2011) Phys. Med. Biol. , vol.56 , pp. 4749-4770
    • Inaniwa, T.1    Kanematsu, N.2    Furukawa, T.3    Hasegawa, A.4
  • 16
    • 78650016388 scopus 로고    scopus 로고
    • Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model
    • 10.1088/0031-9155/55/22/008
    • T. Inaniwa, T. Furukawa, Y. Kase, N. Matsufuji, T. Toshito, Y. Matsumoto, Y. Furusawa, and K. Noda, Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model., Phys. Med. Biol. 55, 6721-6737 (2010). 10.1088/0031-9155/55/22/008
    • (2010) Phys. Med. Biol. , vol.55 , pp. 6721-6737
    • Inaniwa, T.1    Furukawa, T.2    Kase, Y.3    Matsufuji, N.4    Toshito, T.5    Matsumoto, Y.6    Furusawa, Y.7    Noda, K.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.