메뉴 건너뛰기




Volumn 4, Issue , 2007, Pages 2564-2567

GEANT4 based simulation framework for particle therapy system

Author keywords

[No Author keywords available]

Indexed keywords

CODES (STANDARDS); CODES (SYMBOLS); IRRADIATION; MEDICAL IMAGING; PROTON IRRADIATION; RADIATION; RADIOTHERAPY;

EID: 48149110674     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436673     Document Type: Conference Paper
Times cited : (58)

References (14)
  • 1
    • 0038377458 scopus 로고    scopus 로고
    • Geant4-a simulation toolkit
    • S. Agostinelli et al., Geant4-a simulation toolkit. Nucl. Instr. Meth., A506, 2003, pp.250-303.
    • (2003) Nucl. Instr. Meth , vol.A506 , pp. 250-303
    • Agostinelli, S.1
  • 2
    • 11844255391 scopus 로고    scopus 로고
    • Implementation of a new Monte Carlo simulation tool for the development of a proton therapy beam line and verification of the related dose distributions
    • G.A.P. Cirrone et al., Implementation of a new Monte Carlo simulation tool for the development of a proton therapy beam line and verification of the related dose distributions, in Proc. IEEE. NSS/MIC, 3, 2003, pp. 1765-1758.
    • (2003) Proc. IEEE. NSS/MIC , vol.3 , pp. 1765-1758
    • Cirrone, G.A.P.1
  • 3
    • 3142702743 scopus 로고    scopus 로고
    • Accurate Monte Carlo simulations for nozzle design commissioning and quality assurance for a proton radiation therapy facility
    • H. Paganetti et al., Accurate Monte Carlo simulations for nozzle design commissioning and quality assurance for a proton radiation therapy facility, Med. Phys., 31, 2004, pp.2107-2118.
    • (2004) Med. Phys , vol.31 , pp. 2107-2118
    • Paganetti, H.1
  • 4
    • 27644517922 scopus 로고    scopus 로고
    • Verification of the dose distributions with GEANT4 simulation for proton therapy
    • T. Aso et al., Verification of the dose distributions with GEANT4 simulation for proton therapy, IEEE Trans., Vol.52, Issue 4, 2005, pp.896-902.
    • (2005) IEEE Trans , vol.52 , Issue.4 , pp. 896-902
    • Aso, T.1
  • 5
    • 48149103627 scopus 로고    scopus 로고
    • American College of Radiology, National Electrical Manufactures Association Digital Imaging and Communications in Medicine DICOM, Version 3.0, In ACR/NEMA Standards Publication No.PS3
    • American College of Radiology, National Electrical Manufactures Association Digital Imaging and Communications in Medicine (DICOM): Version 3.0., In ACR/NEMA Standards Publication No.PS3.
  • 6
    • 48149095326 scopus 로고    scopus 로고
    • Available
    • National Institute of Standards and Technology, PSTARprogram [Online], Available http://physics.nist.gov/PhysRefData/Star/Text/PSTAR.html
    • PSTARprogram [Online]
  • 7
    • 48149096140 scopus 로고    scopus 로고
    • DICOM Data Handling for Geant4-Based Medical Physics Application
    • Rome, Italy
    • A. Kimura et al., DICOM Data Handling for Geant4-Based Medical Physics Application, IEEE. NS Sympo., 13th, 2004, Rome, Italy.
    • IEEE. NS Sympo , vol.13 th , pp. 2004
    • Kimura, A.1
  • 10
    • 0344466463 scopus 로고    scopus 로고
    • Ridge filter design for proton therapy at Hyogo Ion Beam Medical Center
    • T. Akagi et al., Ridge filter design for proton therapy at Hyogo Ion Beam Medical Center, Phys. Med. Biol., 48, 2003, N301-N312.
    • (2003) Phys. Med. Biol , vol.48
    • Akagi, T.1
  • 12
    • 0030260352 scopus 로고    scopus 로고
    • New UCSF proton ocular beam facility at the Crocker Nuclear Laboratory
    • I.K. Daftari et al., New UCSF proton ocular beam facility at the Crocker Nuclear Laboratory, Nucl. Instr. Meth., A380, 1996, 597-612.
    • (1996) Nucl. Instr. Meth , vol.A380 , pp. 597-612
    • Daftari, I.K.1
  • 13
    • 48149100012 scopus 로고    scopus 로고
    • Simulation of a heavy ion therapy system using Geant4
    • San Diego, USA
    • S. Kameoka et al., Simulation of a heavy ion therapy system using Geant4, IEEE. NS Sympo., 15th, 2006, San Diego, USA.
    • IEEE. NS Sympo , vol.15 th , pp. 2006
    • Kameoka, S.1
  • 14
    • 0034316964 scopus 로고    scopus 로고
    • Tumortherapy with ion beams
    • G. Kraft., Tumortherapy with ion beams, Nucl. Instr. Meth., A454, 2000, 1-10.
    • (2000) Nucl. Instr. Meth , vol.A454 , pp. 1-10
    • Kraft, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.