Volumn 5, Issue 5, 2012, Pages 513-514

Post-dilating transcatheter heart valves

Author keywords

aortic stenosis; aortic valve; transcatheter

Indexed keywords

AORTA VALVE REGURGITATION; ATRIOVENTRICULAR BLOCK; BALLOON DILATATION; BRAIN EMBOLISM; CALCIFICATION; DISEASE SEVERITY; DOPPLER ECHOGRAPHY; FLUOROSCOPY; HEART VALVE PROSTHESIS; HUMAN; MULTIDETECTOR COMPUTED TOMOGRAPHY; NOTE; PRIORITY JOURNAL; STROKE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSIENT ISCHEMIC ATTACK;

EID: 84861552113     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2012.02.011     Document Type: Editorial
Times cited : (8)

References (18)
  • 1
    • 84861534743 scopus 로고    scopus 로고
    • Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve
    • L. Nombela-Franco, J. Rodés-Cabau, R. DeLarochellière Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve J Am Coll Cardiol Intv 5 2012 499 512
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 499-512
    • Nombela-Franco, L.1    Rodés-Cabau, J.2    Delarochellière, R.3
  • 2
    • 41949127025 scopus 로고    scopus 로고
    • Re-dilation of balloon expandable aortic valves [beav]: What do we know?
    • S. Pasupati, A. Sinhal, K. Humphries Re-dilation of balloon expandable aortic valves [beav]: what do we know? Am J Cardiol 100 2007 57L
    • (2007) Am J Cardiol , vol.100
    • Pasupati, S.1    Sinhal, A.2    Humphries, K.3
  • 3
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis
    • A. Willson, J.G. Webb, J. Leipsic 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis J Am Coll Cardiol 59 2012 1287 1294
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.1    Webb, J.G.2    Leipsic, J.3
  • 4
    • 84856460597 scopus 로고    scopus 로고
    • Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilation
    • K. Takagi, A. Latib, R. Al-Lamee Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilation Catheter Cardiovasc Interv 78 2011 432 443
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 432-443
    • Takagi, K.1    Latib, A.2    Al-Lamee, R.3
  • 5
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • C. Tamburino, D. Capodanno, A. Ramondo Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis Circulation 123 2011 299 308
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 6
    • 79961042044 scopus 로고    scopus 로고
    • Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement
    • W.Y. Szeto, J.G. Augoustides, N.D. Desai Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement J Card Surg 26 2011 348 354
    • (2011) J Card Surg , vol.26 , pp. 348-354
    • Szeto, W.Y.1    Augoustides, J.G.2    Desai, N.D.3
  • 7
    • 79953835907 scopus 로고    scopus 로고
    • Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic corevalve prosthesis due to a too-low implantation, using transcatheter repositioning
    • R. Zahn, R. Schiele, C. Kilkowski Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic corevalve prosthesis due to a too-low implantation, using transcatheter repositioning J Heart Valve Dis 20 2011 64 69
    • (2011) J Heart Valve Dis , vol.20 , pp. 64-69
    • Zahn, R.1    Schiele, R.2    Kilkowski, C.3
  • 8
    • 84861533158 scopus 로고    scopus 로고
    • Multiple cerebral emboli following dislocation and retraction of a partially deployed corevalve prosthesis during transcatheter aortic valve implantation
    • [E-pub ahead of print]
    • T.A. Fairbairn, J.P. Greenwood, D.J. Blackman Multiple cerebral emboli following dislocation and retraction of a partially deployed corevalve prosthesis during transcatheter aortic valve implantation Catheter Cardiovasc Interv 2011 Sept 27 [E-pub ahead of print]
    • (2011) Catheter Cardiovasc Interv
    • Fairbairn, T.A.1    Greenwood, J.P.2    Blackman, D.J.3
  • 9
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome Results from the German transcatheter aortic valve interventions registry
    • M. Abdel-Wahab, R. Zahn, M. Horack Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome Results from the German transcatheter aortic valve interventions registry Heart 97 2011 899 906
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 10
    • 84861536423 scopus 로고    scopus 로고
    • Two year outcomes after transcatheter or surgical replacement in high risk patients with aortic stenosis
    • [E-pub ahead of print]
    • S. Kodali, M. Williams, C.R. Smith Two year outcomes after transcatheter or surgical replacement in high risk patients with aortic stenosis N Engl J Med 2012 Mar 27 [E-pub ahead of print]
    • (2012) N Engl J Med
    • Kodali, S.1    Williams, M.2    Smith, C.R.3
  • 11
    • 80055011535 scopus 로고    scopus 로고
    • Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: Impact of aortic cusp calcification on postoperative aortic regurgitation
    • A. Colli, R. D'Amico, J. Kempfert, M.A. Borger, F.W. Mohr, T. Walther Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: impact of aortic cusp calcification on postoperative aortic regurgitation J Thorac Cardiovasc Surg 142 2011 1229 1235
    • (2011) J Thorac Cardiovasc Surg , vol.142 , pp. 1229-1235
    • Colli, A.1    D'Amico, R.2    Kempfert, J.3    Borger, M.A.4    Mohr, F.W.5    Walther, T.6
  • 12
    • 84855784380 scopus 로고    scopus 로고
    • Transcranial Doppler microembolic signals and serum marker evidence of brain injury during transcatheter aortic valve implantation
    • B. Reinsfelt, A. Westerlind, D. Ioanes, H. Zetterberg, J. Fredén-Lindqvist, S.E. Ricksten Transcranial Doppler microembolic signals and serum marker evidence of brain injury during transcatheter aortic valve implantation Acta Anaesthesiol Scand 56 2012 240 247
    • (2012) Acta Anaesthesiol Scand , vol.56 , pp. 240-247
    • Reinsfelt, B.1    Westerlind, A.2    Ioanes, D.3    Zetterberg, H.4    Fredén- Lindqvist, J.5    Ricksten, S.E.6
  • 13
    • 80052893501 scopus 로고    scopus 로고
    • Transcranial Doppler sound detection of cerebral microembolism during transapical aortic valve implantation
    • T. Drews, M. Pasic, S. Buz Transcranial Doppler sound detection of cerebral microembolism during transapical aortic valve implantation Thorac Cardiovasc Surg 59 2011 237 242
    • (2011) Thorac Cardiovasc Surg , vol.59 , pp. 237-242
    • Drews, T.1    Pasic, M.2    Buz, S.3
  • 14
    • 80055107711 scopus 로고    scopus 로고
    • Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilation after TAVI with the Medtronic CoreValve prosthesis
    • C. Schultz, A. Rossi, N. van Mieghem Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilation after TAVI with the Medtronic CoreValve prosthesis EuroIntervention 7 2011 564 572
    • (2011) EuroIntervention , vol.7 , pp. 564-572
    • Schultz, C.1    Rossi, A.2    Van Mieghem, N.3
  • 15
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • D. Detaint, L. Lepage, D. Himbert Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence J Am Coll Cardiol Intv 2 2009 821 827
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3
  • 16
    • 60949086687 scopus 로고    scopus 로고
    • Early conduction disorders following percutaneous aortic valve replacement
    • V. Calvi, E. Puzzangara, G.P.P. Pruiti Early conduction disorders following percutaneous aortic valve replacement Pacing Clin Electrophysiol 32 Suppl 1 2009 S126 S130
    • (2009) Pacing Clin Electrophysiol , vol.32 , Issue.SUPPL. 1
    • Calvi, V.1    Puzzangara, E.2    Pruiti, G.P.P.3
  • 18
    • 79960593630 scopus 로고    scopus 로고
    • Feasibility of transcatheter aortic valve implantation without balloon pre-dilation: A pilot study
    • E. Grube, C. Naber, A. Abizaid Feasibility of transcatheter aortic valve implantation without balloon pre-dilation: a pilot study J Am Coll Cardiol Intv 4 2011 751 757
    • (2011) J Am Coll Cardiol Intv , vol.4 , pp. 751-757
    • Grube, E.1    Naber, C.2    Abizaid, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.