메뉴 건너뛰기




Volumn 8, Issue 2-4, 2011, Pages

Contrast agents and mechanisms

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL EXCHANGE SATURATION TRANSFER AGENT; GADODIAMIDE; GADOLINIUM PENTETATE; GADOTERATE MEGLUMINE; GADOTERIDOL; NUCLEAR MAGNETIC RESONANCE IMAGING AGENT; SUPERPARAMAGNETIC IRON OXIDE NANOPARTICLE; TARGETED AND NANOSIZED SYSTEM AGENT; UNCLASSIFIED DRUG;

EID: 84861232269     PISSN: None     EISSN: 17406749     Source Type: Journal    
DOI: 10.1016/j.ddtec.2011.11.013     Document Type: Review
Times cited : (12)

References (36)
  • 1
    • 0033363494 scopus 로고    scopus 로고
    • Gadolinium(III) chelates as MRI contrast agents: Structure, dynamics, and applications
    • DOI 10.1021/cr980440x
    • Caravan, P. et al. (1999) Gadolinium(III) chelates as MRI contrast agents: structure, dynamics, and applications. Chem Rev 99, 2293-2352 (Pubitemid 30498114)
    • (1999) Chemical Reviews , vol.99 , Issue.9 , pp. 2293-2352
    • Caravan, P.1    Ellison, J.J.2    McMurry, T.J.3    Lauffer, R.B.4
  • 2
    • 33747602797 scopus 로고    scopus 로고
    • Relaxation by metal-containing nanosystems
    • (van Eldik, R. and Bertini, I., eds), Elsevier
    • Muller, R. et al. (2005) Relaxation by metal-containing nanosystems. In Advances in Inorganic Chemistry (van Eldik, R. and Bertini, I., eds), pp. 239-292, Elsevier
    • (2005) Advances in Inorganic Chemistry , pp. 239-292
    • Muller, R.1
  • 3
    • 77952484017 scopus 로고    scopus 로고
    • Challenges for molecular magnetic resonance imaging
    • Terreno, E. et al. (2010) Challenges for molecular magnetic resonance imaging. Chem Rev 110, 3019-3042
    • (2010) Chem Rev , vol.110 , pp. 3019-3042
    • Terreno, E.1
  • 4
    • 34247590053 scopus 로고    scopus 로고
    • Comparative study of the physicochemical properties of six clinical low molecular weight gadoliniumcontrast agents
    • Laurent, S. et al. (2006) Comparative study of the physicochemical properties of six clinical low molecular weight gadoliniumcontrast agents. Contrast Media Mol Imaging 1, 128-137
    • (2006) Contrast Media Mol Imaging , vol.1 , pp. 128-137
    • Laurent, S.1
  • 5
    • 67651122843 scopus 로고    scopus 로고
    • Gd-hydroxypyridinone (HOPO)- based high-relaxivity magnetic resonance imaging (MRI) contrast agents
    • Datta, A. and Raymond, K.N. (2009) Gd-hydroxypyridinone (HOPO)- based high-relaxivity magnetic resonance imaging (MRI) contrast agents. Acc Chem Res 42, 938-947
    • (2009) Acc Chem Res , vol.42 , pp. 938-947
    • Datta, A.1    Raymond, K.N.2
  • 6
    • 9444270383 scopus 로고    scopus 로고
    • [Gd-AAZTA]: A new structural entry for an improved generation of MRI contrast agents
    • Aime, S. et al. (2004) [Gd-AAZTA]: a new structural entry for an improved generation of MRI contrast agents. Inorg Chem 43, 7588-7590
    • (2004) Inorg Chem , vol.43 , pp. 7588-7590
    • Aime, S.1
  • 8
    • 0031452736 scopus 로고    scopus 로고
    • Gadolinium chelates with weak binding to serum proteins
    • Cavagna, F.M. et al. (1997) Gadolinium chelates with weak binding to serum proteins. Invest Radiol 32, 780-796
    • (1997) Invest Radiol , vol.32 , pp. 780-796
    • Cavagna, F.M.1
  • 9
    • 77953425066 scopus 로고    scopus 로고
    • Targeted probes for cardiovascular MRI
    • Uppal, R. and Caravan, P. (2010) Targeted probes for cardiovascular MRI. Future Med Chem 2, 451-470
    • (2010) Future Med Chem , vol.2 , pp. 451-470
    • Uppal, R.1    Caravan, P.2
  • 11
    • 0037087670 scopus 로고    scopus 로고
    • Compartmentalization of a gadolinium complex in the apoferritin cavity: A route to obtain high relaxivity contrast agents for magnetic resonance imaging
    • DOI 10.1002/1521-3773(20020315)41:6<1017::AID-ANIE1017>3.0.CO;2-P
    • Aime, S. et al. (2002) Compartmentalization of a gadolinium complex in the apoferritin cavity: a route to obtain high relaxivity contrast agents for magnetic resonance imaging. Angew Chem Int Ed Engl 41, 1017-1019 (Pubitemid 34251900)
    • (2002) Angewandte Chemie - International Edition , vol.41 , Issue.6 , pp. 1017-1019
    • Aime, S.1    Frullano, L.2    Crich, S.G.3
  • 12
    • 37149042647 scopus 로고    scopus 로고
    • Magnetic resonance imaging detection of tumor cells by targeting low-density lipoprotein receptors with Gd-loaded low-density lipoprotein particles
    • Geninatti Crich, S. et al. (2007) Magnetic resonance imaging detection of tumor cells by targeting low-density lipoprotein receptors with Gd-loaded low-density lipoprotein particles. Neoplasia 9, 1046-1056
    • (2007) Neoplasia , vol.9 , pp. 1046-1056
    • Geninatti Crich, S.1
  • 14
    • 34548170558 scopus 로고    scopus 로고
    • Magnetic resonance contrast agents from viral capsid shells: A comparison of exterior and interior cargo strategies
    • DOI 10.1021/nl070512c
    • Hooker, J.M. et al. (2007) Magnetic resonance contrast agents from viral capsid shells: a comparison of exterior and interior cargo strategies. Nano Lett 7, 2207-2210 (Pubitemid 47310107)
    • (2007) Nano Letters , vol.7 , Issue.8 , pp. 2207-2210
    • Hooker, J.M.1    Datta, A.2    Botta, M.3    Raymond, K.N.4    Francis, M.B.5
  • 15
    • 80052951955 scopus 로고    scopus 로고
    • Yeast cell wall particles: A promising class of nature-inspired microcarriers for multimodal imaging
    • Figueiredo, S. et al. (2011) Yeast cell wall particles: a promising class of nature-inspired microcarriers for multimodal imaging. Chem Commun 47, 10635
    • (2011) Chem Commun , vol.47 , pp. 10635
    • Figueiredo, S.1
  • 16
    • 50849137152 scopus 로고    scopus 로고
    • Metal containing nanosized systems for MRmolecular imaging applications
    • Delli Castelli, D. et al. (2008) Metal containing nanosized systems for MRmolecular imaging applications. Coord Chem Rev 252, 2424-2443
    • (2008) Coord Chem Rev , vol.252 , pp. 2424-2443
    • Delli Castelli, D.1
  • 17
    • 58449094540 scopus 로고    scopus 로고
    • Tuning glutamine binding modes in Gd-DOTAbased probes for an improved MRI visualization of tumor cells
    • Stefania, K. et al. (2009) Tuning glutamine binding modes in Gd-DOTAbased probes for an improved MRI visualization of tumor cells. Chem Eur J 15, 76-85
    • (2009) Chem Eur J , vol.15 , pp. 76-85
    • Stefania, K.1
  • 18
    • 41849103736 scopus 로고    scopus 로고
    • MR imaging of ovarian tumors using folatereceptor- targeted contrast agents
    • Wang, Z.J. et al. (2008) MR imaging of ovarian tumors using folatereceptor- targeted contrast agents. Pediatr Radiol 38, 529-537
    • (2008) Pediatr Radiol , vol.38 , pp. 529-537
    • Wang, Z.J.1
  • 19
    • 57149104739 scopus 로고    scopus 로고
    • Tumor imaging using P866, a high-relaxivity gadolinium chelate designed for folate receptor targeting
    • Corot, C. et al. (2008) Tumor imaging using P866, a high-relaxivity gadolinium chelate designed for folate receptor targeting. Magn Reson Med 60, 1337-1346
    • (2008) Magn Reson Med , vol.60 , pp. 1337-1346
    • Corot, C.1
  • 20
    • 33645674562 scopus 로고    scopus 로고
    • Gd(III)-based contrast agents for MRI
    • Elsevier
    • Aime, S. et al. (2005) Gd(III)-based contrast agents for MRI. In Advances in Inorganic Chemistry. Elsevier pp. 173-237
    • (2005) Advances in Inorganic Chemistry , pp. 173-237
    • Aime, S.1
  • 21
    • 33748342737 scopus 로고    scopus 로고
    • 1 ratiometric procedure for a concentration-independent, pH-responsive, Gd(III)-based MRI agent
    • DOI 10.1021/ja062387x
    • Aime, S. et al. (2006) A R2/R1 ratiometric procedure for a concentrationindependent, pH-responsive, Gd(III)-based MRI agent. J Am Chem Soc 128, 11326-11327 (Pubitemid 44338806)
    • (2006) Journal of the American Chemical Society , vol.128 , Issue.35 , pp. 11326-11327
    • Aime, S.1    Fedeli, F.2    Sanino, A.3    Terreno, E.4
  • 23
    • 72449155212 scopus 로고    scopus 로고
    • Iron oxide based MR contrast agents: From chemistry to cell labeling
    • Laurent, S. et al. (2009) Iron oxide based MR contrast agents: from chemistry to cell labeling. Curr Med Chem 16, 4712-4727
    • (2009) Curr Med Chem , vol.16 , pp. 4712-4727
    • Laurent, S.1
  • 24
    • 10644271515 scopus 로고    scopus 로고
    • A non-invasive approach to detecting organ rejection by MRI: Monitoring the accumulation of immune cells at the transplanted organ
    • DOI 10.2174/1389201043376535
    • Ho, C. and Hitchens, T.K. (2004) A non-invasive approach to detecting organ rejection by MRI: monitoring the accumulation of immune cells at the transplanted organ. Curr Pharm Biotechnol 5, 551-566 (Pubitemid 39654852)
    • (2004) Current Pharmaceutical Biotechnology , vol.5 , Issue.6 , pp. 551-566
    • Ho, C.1    Hitchens, T.K.2
  • 25
    • 33646950283 scopus 로고    scopus 로고
    • High sensitivity lanthanide(III) based probes for MRmedical imaging
    • Aime, S. et al. (2006) High sensitivity lanthanide(III) based probes for MRmedical imaging. Coord Chem Rev 250, 1562-1579
    • (2006) Coord Chem Rev , vol.250 , pp. 1562-1579
    • Aime, S.1
  • 26
    • 50249145152 scopus 로고    scopus 로고
    • Chemical exchange saturation transfer contrast agents for magnetic resonance imaging
    • Sherry, A.D. and Woods, M. (2008) Chemical exchange saturation transfer contrast agents for magnetic resonance imaging. Annu Rev Biomed Eng 10, 391-411
    • (2008) Annu Rev Biomed Eng , vol.10 , pp. 391-411
    • Sherry, A.D.1    Woods, M.2
  • 27
    • 33744523144 scopus 로고    scopus 로고
    • Paramagnetic lanthanide complexes as PARACEST agents for medical imaging
    • Woods, M. et al. (2006) Paramagnetic lanthanide complexes as PARACEST agents for medical imaging. Chem Soc Rev 35, 500
    • (2006) Chem Soc Rev , vol.35 , pp. 500
    • Woods, M.1
  • 28
    • 77951553892 scopus 로고    scopus 로고
    • Encoding the frequency dependence in MRI contrast media: The emerging class of CEST agents
    • Terreno, E. et al. (2010) Encoding the frequency dependence in MRI contrast media: the emerging class of CEST agents. Contrast Media Mol Imaging 5, 78-98
    • (2010) Contrast Media Mol Imaging , vol.5 , pp. 78-98
    • Terreno, E.1
  • 30
    • 0024854952 scopus 로고
    • 13C investigations
    • DOI 10.1002/mrm.1910120313
    • Müller, S. and Beckmann, N. (1989) 13C spectroscopic imaging A simple approach to in vivo 13C investigations. Magn Reson Med 12, 400-406 (Pubitemid 20044441)
    • (1989) Magnetic Resonance in Medicine , vol.12 , Issue.3 , pp. 400-406
    • Muller, S.1    Beckmann, N.2
  • 31
    • 77949778525 scopus 로고    scopus 로고
    • Hyperpolarized agents for advanced MRI investigations
    • Viale, A. et al. (2009) Hyperpolarized agents for advanced MRI investigations. Q J Nucl Med Mol Imaging 53, 604-617
    • (2009) Q J Nucl Med Mol Imaging , vol.53 , pp. 604-617
    • Viale, A.1
  • 32
    • 75149123911 scopus 로고    scopus 로고
    • Current concepts on hyperpolarized molecules in MRI
    • Viale, A. and Aime, S. (2010) Current concepts on hyperpolarized molecules in MRI. Curr Opin Chem Biol 14, 90-96
    • (2010) Curr Opin Chem Biol , vol.14 , pp. 90-96
    • Viale, A.1    Aime, S.2
  • 33
    • 79951507755 scopus 로고    scopus 로고
    • Analysis of cancer metabolism by imaging hyperpolarized nuclei: Prospects for translation to clinical research
    • Kurhanewicz, J. et al. (2011) Analysis of cancer metabolism by imaging hyperpolarized nuclei: prospects for translation to clinical research. Neoplasia 13, 81-97
    • (2011) Neoplasia , vol.13 , pp. 81-97
    • Kurhanewicz, J.1
  • 34
    • 79960585263 scopus 로고    scopus 로고
    • Tumor imaging using hyperpolarized 13C magnetic resonance spectroscopy
    • Brindle, K.M. et al. (2011) Tumor imaging using hyperpolarized 13C magnetic resonance spectroscopy. Magn Reson Med 66, 505-519
    • (2011) Magn Reson Med , vol.66 , pp. 505-519
    • Brindle, K.M.1
  • 35
    • 0000633163 scopus 로고
    • Principles of dynamic nuclear polarisation
    • Abragam, A. and Goldman, M. (1978) Principles of dynamic nuclear polarisation. Rep Prog Phys 41, 395-467
    • (1978) Rep Prog Phys , vol.41 , pp. 395-467
    • Abragam, A.1    Goldman, M.2
  • 36
    • 36148976010 scopus 로고    scopus 로고
    • Design and performance of a DNP prepolarizer coupled to a rodent MRI scanner
    • Comment, A. et al. (2007) Design and performance of a DNP prepolarizer coupled to a rodent MRI scanner. Concepts Magn Reson B 31B, 255-269
    • (2007) Concepts Magn Reson B , vol.31 B , pp. 255-269
    • Comment, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.