메뉴 건너뛰기




Volumn 19, Issue 2, 2012, Pages 249-260

A comparative analysis of bench-top performance assessment of distal protection filters in transient flow conditions

Author keywords

Distal protection; Embolic protection filter; Flow model; In vitro experiment; Internal carotid artery; Pulsatile flow; Stent; Vascular impedance

Indexed keywords

MICROSPHERE;

EID: 84860719490     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/11-3720.1     Document Type: Article
Times cited : (14)

References (37)
  • 1
    • 0034852489 scopus 로고    scopus 로고
    • Cerebral protection systems for distal emboli during carotid artery interventions
    • Tan WA, Bates MC, Wholey MH. Cerebral protection systems for distal emboli during carotid artery interventions. J Interv Cardiol. 2001;14:465-474. (Pubitemid 32846465)
    • (2001) Journal of Interventional Cardiology , vol.14 , Issue.4 , pp. 465-474
    • Tan, W.A.1    Bates, M.C.2    Wholey, M.H.3
  • 3
    • 41149095871 scopus 로고    scopus 로고
    • A randomized trial of carotid artery stenting with and without cerebral protection
    • Barbato JE, Dillavou E, Horowitz MB, et al. A randomized trial of carotid artery stenting with and without cerebral protection. J Vasc Surg. 2008;47:760-765.
    • (2008) J Vasc Surg , vol.47 , pp. 760-765
    • Barbato, J.E.1    Dillavou, E.2    Horowitz, M.B.3
  • 4
    • 77954204134 scopus 로고    scopus 로고
    • Stenting versus endarterectomy for treatment of carotid-artery stenosis
    • Brott TG, Hobson RW, Howard G, et al. Stenting versus endarterectomy for treatment of carotid-artery stenosis. N Engl J Med. 2010; 363:11-23.
    • (2010) N Engl J Med , vol.363 , pp. 11-23
    • Brott, T.G.1    Hobson, R.W.2    Howard, G.3
  • 6
    • 0037337064 scopus 로고    scopus 로고
    • Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: A systematic review of the literature
    • DOI 10.1161/01.STR.0000058160.53040.5F
    • Kastrup A, Groschel K, Krapf H, et al. Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: a systematic review of the literature. Stroke. 2003;34:813-819. (Pubitemid 36307419)
    • (2003) Stroke , vol.34 , Issue.3 , pp. 813-819
    • Kastrup, A.1    Groschel, K.2    Krapf, H.3    Brehm, B.R.4    Dichgans, J.5    Schulz, J.B.6
  • 7
    • 67249087073 scopus 로고    scopus 로고
    • Reduction of cerebral embolization in carotid angioplasty: An in-vitro experiment comparing 2 cerebral protection devices
    • Charalambous N, Jahnke T, Bolte H, et al. Reduction of cerebral embolization in carotid angioplasty: an in-vitro experiment comparing 2 cerebral protection devices. J Endovasc Ther. 2009;16:161-167.
    • (2009) J Endovasc Ther , vol.16 , pp. 161-167
    • Charalambous, N.1    Jahnke, T.2    Bolte, H.3
  • 8
    • 0036787405 scopus 로고    scopus 로고
    • Comparison and modification of two cerebral protection devices used for carotid angioplasty: In vitro experiment
    • Müller-Hülsbeck S, Grimm J, Liess C, et al. Comparison and modification of two cerebral protection devices used for carotid angioplasty: in vitro experiment. Radiology. 2002;225: 289-294.
    • (2002) Radiology , vol.225 , pp. 289-294
    • Müller-Hülsbeck, S.1    Grimm, J.2    Liess, C.3
  • 11
    • 0345505722 scopus 로고    scopus 로고
    • In vitro comparison of four cerebral protection filters for preventing human plaque embolization during carotid interventions
    • DOI 10.1583/1545-1550(2002)009<0793:IVCOFC>2.0.CO;2
    • Müller-Hülsbeck S, Jahnke T, Liess C, et al. In vitro comparison of four cerebral protection filters for preventing human plaque embolization during carotid interventions. J Endovasc Ther. 2002;9:793-802. (Pubitemid 36228024)
    • (2002) Journal of Endovascular Therapy , vol.9 , Issue.6 , pp. 793-802
    • Muller-Hulsbeck, S.1    Jahnke, T.2    Liess, C.3    Glass, C.4    Paulsen, F.5    Grimm, J.6    Heller, M.7
  • 12
    • 0032763179 scopus 로고    scopus 로고
    • Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis
    • Ohki T, Roubin GS, Veith FJ, et al. Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: an ex vivo analysis. J Vasc Surg. 1999;30:1034-1044.
    • (1999) J Vasc Surg , vol.30 , pp. 1034-1044
    • Ohki, T.1    Roubin, G.S.2    Veith, F.J.3
  • 16
    • 43049150398 scopus 로고    scopus 로고
    • Wall apposition assessment and performance comparison of distal protection filters
    • Finol EA, Siewiorek GM, Scotti CM, et al. Wall apposition assessment and performance comparison of distal protection filters. J Endovasc Ther. 2008;15:177-186.
    • (2008) J Endovasc Ther , vol.15 , pp. 177-186
    • Finol, E.A.1    Siewiorek, G.M.2    Scotti, C.M.3
  • 17
    • 35348972924 scopus 로고    scopus 로고
    • In vitro performance assessment of distal protection devices for carotid artery stenting: Effect of physiological anatomy on vascular resistance
    • DOI 10.1583/1545-1550(2007)14[712:IVPAOD]2.0.CO;2
    • Siewiorek GM, Wholey MH, Finol EA. In vitro performance assessment of distal protection devices for carotid artery stenting: effect of physiological anatomy on vascular resistance. J Endovasc Ther. 2007;14:712-724. (Pubitemid 47598199)
    • (2007) Journal of Endovascular Therapy , vol.14 , Issue.5 , pp. 712-724
    • Siewiorek, G.M.1    Wholey, M.H.2    Finol, E.A.3
  • 18
    • 52149117617 scopus 로고    scopus 로고
    • Vascular resistance in the carotid artery: An in vitro investigation of embolic protection filters
    • Siewiorek GM, Wholey MH, Finol EA. Vascular resistance in the carotid artery: an in vitro investigation of embolic protection filters. J Vasc Interv Radiol. 2008;19:1467-1476.
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 1467-1476
    • Siewiorek, G.M.1    Wholey, M.H.2    Finol, E.A.3
  • 19
    • 74949085047 scopus 로고    scopus 로고
    • In vitro performance assessment of distal protection filters: Pulsatile flow conditions
    • Siewiorek GM, Wholey MH, Finol EA. In vitro performance assessment of distal protection filters: pulsatile flow conditions. J Endovasc Ther. 2009;16:735-743.
    • (2009) J Endovasc Ther , vol.16 , pp. 735-743
    • Siewiorek, G.M.1    Wholey, M.H.2    Finol, E.A.3
  • 20
    • 0032773052 scopus 로고    scopus 로고
    • Characterization of common carotid artery blood-flow waveforms in normal human subjects
    • DOI 10.1088/0967-3334/20/3/301, PII S0967333499975457
    • Holdsworth DW, Norley CJ, Frayne R, et al. Characterization of common carotid artery blood-flow waveforms in normal human subjects. Physiol Meas. 1999;20:219-240. (Pubitemid 29399835)
    • (1999) Physiological Measurement , vol.20 , Issue.3 , pp. 219-240
    • Holdsworth, D.W.1    Norley, C.J.D.2    Frayne, R.3    Steinman, D.A.4    Rutt, B.K.5
  • 21
    • 7544234586 scopus 로고    scopus 로고
    • Extraction of pulmonary vascular compliance, pulmonary vascular resistance, and right ventricular work from single-pressure and doppler flow measurements in children with pulmonary hypertension: A new method for evaluating reactivity - In vitro and clinical studies
    • DOI 10.1161/01.CIR.0000146818.60588.40
    • Weinberg CE, Hertzberg JR, Ivy DD, et al. Extraction of pulmonary vascular compliance, pulmonary vascular resistance, and right ventricular work from single-pressure and Doppler flow measurements in children with pulmonary hypertension: a new method for evaluating reactivity: in vitro and clinical studies. Circulation. 2004;110:2609-2617. (Pubitemid 39453010)
    • (2004) Circulation , vol.110 , Issue.17 , pp. 2609-2617
    • Weinberg, C.E.1    Hertzberg, J.R.2    Ivy, D.D.3    Kirby, K.S.4    Chan, K.C.5    Valdes-Cruz, L.6    Shandas, R.7
  • 22
    • 0037351047 scopus 로고    scopus 로고
    • Carotid stenting with filter protection: Correlation of ACT values with angiographic and histopathologic findings
    • Castellani L, Causin F, Danieli D, et al. Carotid stenting with filter protection. Correlation of ACT values with angiographic and histopathologic findings. J Neuroradiol. 2003;30:103-108. (Pubitemid 36383487)
    • (2003) Journal of Neuroradiology , vol.30 , Issue.2 , pp. 103-108
    • Castellan, L.1    Causin, F.2    Danieli, D.3    Perini, S.4
  • 23
    • 80051715724 scopus 로고    scopus 로고
    • Increases in cerebrovascular impedance in older adults
    • Zhu YS, Tseng BY, Shibata S, et al. Increases in cerebrovascular impedance in older adults. J Appl Physiol. 2011;111:376-381.
    • (2011) J Appl Physiol , vol.111 , pp. 376-381
    • Zhu, Y.S.1    Tseng, B.Y.2    Shibata, S.3
  • 25
    • 1842682027 scopus 로고    scopus 로고
    • Comparison of 4 Cerebral Protection Filters for Carotid Angioplasty: An In Vitro Experiment Focusing on Carotid Anatomy
    • DOI 10.1583/03-1131.1
    • Order BM, Glass C, Liess C, et al. Comparison of 4 cerebral protection filters for carotid angioplasty: an in vitro experiment focusing on carotid anatomy. J Endovasc Ther. 2004; 11:211-218. (Pubitemid 38481076)
    • (2004) Journal of Endovascular Therapy , vol.11 , Issue.2 , pp. 211-218
    • Order, B.-M.1    Glass, C.2    Liess, C.3    Heller, M.4    Muller-Hulsbeck, S.5
  • 27
    • 20444444559 scopus 로고    scopus 로고
    • Morphometric analysis of particulate debris extracted by four different embolic protection devices from coronary arteries, aortocoronary saphenous vein conduits, and carotid arteries
    • DOI 10.1016/j.amjcard.2005.02.006, PII S0002914905004637
    • Quan VH, Huynh R, Seifert PA, et al. Morphometric analysis of particulate debris extracted by four different embolic protection devices from coronary arteries, aortocoronary saphenous vein conduits, and carotid arteries. Am J Cardiol. 2005;95:1415-1419. (Pubitemid 40824759)
    • (2005) American Journal of Cardiology , vol.95 , Issue.12 , pp. 1415-1419
    • Quan, V.-H.1    Huynh, R.2    Seifert, P.A.3    Kuchela, A.4    Chen, W.-H.5    Sutsch, G.6    Eisenhauer, A.C.7    Rogers, C.8
  • 28
    • 80051669765 scopus 로고    scopus 로고
    • The association of clinical variables and filter design with carotid artery stenting thirty-day outcome
    • Siewiorek GM, Krafty RT, Wholey MH, et al. The association of clinical variables and filter design with carotid artery stenting thirty-day outcome. Eur J Vasc Endovasc Surg. 2011;42: 282-291.
    • (2011) Eur J Vasc Endovasc Surg , vol.42 , pp. 282-291
    • Siewiorek, G.M.1    Krafty, R.T.2    Wholey, M.H.3
  • 30
    • 33646040403 scopus 로고    scopus 로고
    • Carotid stenting with distal protection in high surgical risk patients: The BEACH trial 30 day results
    • White CJ, Iyer SS, Hopkins LN, et al. Carotid stenting with distal protection in high surgical risk patients: the BEACH trial 30 day results. Catheter Cardiovasc Interv. 2006;67:503-512.
    • (2006) Catheter Cardiovasc Interv , vol.67 , pp. 503-512
    • White, C.J.1    Iyer, S.S.2    Hopkins, L.N.3
  • 35
    • 34748922895 scopus 로고    scopus 로고
    • The CAPTURE registry: Analysis of strokes resulting from carotid artery stenting in the post approval setting: timing, location, severity, and type
    • Fairman R, Gray WA, Scicli AP, et al. The CAPTURE registry: analysis of strokes resulting from carotid artery stenting in the post approval setting: timing, location, severity, and type. Ann Surg. 2007;246:551-558.
    • (2007) Ann Surg , vol.246 , pp. 551-558
    • Fairman, R.1    Gray, W.A.2    Scicli, A.P.3
  • 36
    • 69949104161 scopus 로고    scopus 로고
    • Thirty-day outcomes for carotid artery stenting in 6320 patients from 2 prospective, multicenter, high-surgical-risk registries
    • Gray WA, Chaturvedi S, Verta P, et al. Thirty-day outcomes for carotid artery stenting in 6320 patients from 2 prospective, multicenter, high-surgical-risk registries. Circ Cardiovasc Interv. 2009;2:159-166.
    • (2009) Circ Cardiovasc Interv , vol.2 , pp. 159-166
    • Gray, W.A.1    Chaturvedi, S.2    Verta, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.