-
1
-
-
0034852489
-
Cerebral protection systems for distal emboli during carotid artery interventions
-
Tan WA, Bates MC, Wholey MH. Cerebral protection systems for distal emboli during carotid artery interventions. J Interv Cardiol. 2001;14:465-474. (Pubitemid 32846465)
-
(2001)
Journal of Interventional Cardiology
, vol.14
, Issue.4
, pp. 465-474
-
-
Tan, W.A.1
Bates, M.C.2
Wholey, M.H.3
-
2
-
-
33846101729
-
ACCF/SCAI/SVMB/SIR/ASITN 2007 Clinical Expert Consensus Document on Carotid Stenting. A Report of the American College of Cardiology Foundation Task Force on Clinical Expert Consensus Documents (ACCF/SCAI/SVMB/SIR/ASITN Clinical Expert Consensus Document Committee on Carotid Stenting)
-
DOI 10.1016/j.jacc.2006.10.021, PII S0735109706025186
-
Bates ER, Babb JD, Casey DE, et al. ACCF/SCAI/SVMB/SIR/ASITN 2007 clinical expert consensus document on carotid stenting: a report of the American College of Cardiology Foundation Task Force on Clinical Expert Consensus Documents (ACCF/SCAI/SVMB/SIR/ASITN Clinical Expert Consensus Document Committee on Carotid Stenting). J Am Coll Cardiol. 2007; 49:126-170. (Pubitemid 46061419)
-
(2007)
Journal of the American College of Cardiology
, vol.49
, Issue.1
, pp. 126-170
-
-
Bates, E.R.1
Babb, J.D.2
Casey Jr., D.E.3
Cates, C.U.4
Duckwiler, G.R.5
Feldman, T.E.6
Gray, W.A.7
Ouriel, K.8
Peterson, E.D.9
Rosenfield, K.10
Rundback, J.H.11
Safian, R.D.12
Sloan, M.A.13
White, C.J.14
Harrington, R.A.15
Abrams, J.16
Anderson, J.L.17
Bates, E.R.18
Eisenberg, M.J.19
Grines, C.L.20
Hlatky, M.A.21
Lichtenberg, R.C.22
Lindner, J.R.23
Pohost, G.M.24
Schofield, R.S.25
Shubrooks Jr., S.J.26
Stein, J.H.27
Tracy, C.M.28
Vogel, R.A.29
Wesley, D.J.30
more..
-
3
-
-
41149095871
-
A randomized trial of carotid artery stenting with and without cerebral protection
-
Barbato JE, Dillavou E, Horowitz MB, et al. A randomized trial of carotid artery stenting with and without cerebral protection. J Vasc Surg. 2008;47:760-765.
-
(2008)
J Vasc Surg
, vol.47
, pp. 760-765
-
-
Barbato, J.E.1
Dillavou, E.2
Horowitz, M.B.3
-
4
-
-
77954204134
-
Stenting versus endarterectomy for treatment of carotid-artery stenosis
-
Brott TG, Hobson RW, Howard G, et al. Stenting versus endarterectomy for treatment of carotid-artery stenosis. N Engl J Med. 2010; 363:11-23.
-
(2010)
N Engl J Med
, vol.363
, pp. 11-23
-
-
Brott, T.G.1
Hobson, R.W.2
Howard, G.3
-
6
-
-
0037337064
-
Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: A systematic review of the literature
-
DOI 10.1161/01.STR.0000058160.53040.5F
-
Kastrup A, Groschel K, Krapf H, et al. Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: a systematic review of the literature. Stroke. 2003;34:813-819. (Pubitemid 36307419)
-
(2003)
Stroke
, vol.34
, Issue.3
, pp. 813-819
-
-
Kastrup, A.1
Groschel, K.2
Krapf, H.3
Brehm, B.R.4
Dichgans, J.5
Schulz, J.B.6
-
7
-
-
67249087073
-
Reduction of cerebral embolization in carotid angioplasty: An in-vitro experiment comparing 2 cerebral protection devices
-
Charalambous N, Jahnke T, Bolte H, et al. Reduction of cerebral embolization in carotid angioplasty: an in-vitro experiment comparing 2 cerebral protection devices. J Endovasc Ther. 2009;16:161-167.
-
(2009)
J Endovasc Ther
, vol.16
, pp. 161-167
-
-
Charalambous, N.1
Jahnke, T.2
Bolte, H.3
-
8
-
-
0036787405
-
Comparison and modification of two cerebral protection devices used for carotid angioplasty: In vitro experiment
-
Müller-Hülsbeck S, Grimm J, Liess C, et al. Comparison and modification of two cerebral protection devices used for carotid angioplasty: in vitro experiment. Radiology. 2002;225: 289-294.
-
(2002)
Radiology
, vol.225
, pp. 289-294
-
-
Müller-Hülsbeck, S.1
Grimm, J.2
Liess, C.3
-
9
-
-
8444250938
-
An in vitro analysis of a carotid artery stent with a protective porous membrane
-
DOI 10.1097/01.RVI.0000141339.79538.0D
-
Müller-Hülsbeck S, Husler EJ, Schaffner SR, et al. An in vitro analysis of a carotid artery stent with a protective membrane. J Vasc Interv Radiol. 2004;15:1295-1305. (Pubitemid 39487861)
-
(2004)
Journal of Vascular and Interventional Radiology
, vol.15
, Issue.11
, pp. 1295-1305
-
-
Muller-Hulsbeck, S.1
Husler, E.J.2
Schaffner, S.R.3
Jahnke, T.4
Glass, C.5
Wenke, R.6
Heller, M.7
-
10
-
-
0038814104
-
Comparison of various cerebral protection devices used for carotid artery stent placement: An in vitro experiment
-
Müller-Hülsbeck S, Jahnke T, Liess C, et al. Comparison of various cerebral protection devices used for carotid artery stent placement: an in vitro experiment. J Vasc Interv Radiol. 2003;14:613-620. (Pubitemid 36618028)
-
(2003)
Journal of Vascular and Interventional Radiology
, vol.14
, Issue.5
, pp. 613-620
-
-
Muller-Hulsbeck, S.1
Jahnke, T.2
Liess, C.3
Glass, C.4
Grimm, J.5
Heller, M.6
-
11
-
-
0345505722
-
In vitro comparison of four cerebral protection filters for preventing human plaque embolization during carotid interventions
-
DOI 10.1583/1545-1550(2002)009<0793:IVCOFC>2.0.CO;2
-
Müller-Hülsbeck S, Jahnke T, Liess C, et al. In vitro comparison of four cerebral protection filters for preventing human plaque embolization during carotid interventions. J Endovasc Ther. 2002;9:793-802. (Pubitemid 36228024)
-
(2002)
Journal of Endovascular Therapy
, vol.9
, Issue.6
, pp. 793-802
-
-
Muller-Hulsbeck, S.1
Jahnke, T.2
Liess, C.3
Glass, C.4
Paulsen, F.5
Grimm, J.6
Heller, M.7
-
12
-
-
0032763179
-
Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis
-
Ohki T, Roubin GS, Veith FJ, et al. Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: an ex vivo analysis. J Vasc Surg. 1999;30:1034-1044.
-
(1999)
J Vasc Surg
, vol.30
, pp. 1034-1044
-
-
Ohki, T.1
Roubin, G.S.2
Veith, F.J.3
-
13
-
-
26844440447
-
Slow-flow phenomenon during carotid artery intervention with embolic protection devices: Predictors and clinical outcome
-
DOI 10.1016/j.jacc.2005.05.082, PII S0735109705017237
-
Casserly IP, Abou-Chebl A, Fathi RB, et al. Slow-flow phenomenon during carotid artery intervention with embolic protection devices: predictors and clinical outcome. J Am Coll Cardiol. 2005;46:1466-1472. (Pubitemid 41446180)
-
(2005)
Journal of the American College of Cardiology
, vol.46
, Issue.8
, pp. 1466-1472
-
-
Casserly, I.P.1
Abou-Chebl, A.2
Fathi, R.B.3
Lee, D.S.4
Saw, J.5
Exaire, J.E.6
Kapadia, S.R.7
Bajzer, C.T.8
Yadav, J.S.9
-
14
-
-
33144472857
-
Embolic protection filters for carotid stenting: Differences in flow obstruction depending on filter construction
-
DOI 10.1583/04-1325.1
-
Hendriks JM, Zindler JD, van der Lugt A, et al. Embolic protection filters for carotid stenting: differences in flow obstruction depending on filter construction. J Endovasc Ther. 2006;13:47-50. (Pubitemid 43271482)
-
(2006)
Journal of Endovascular Therapy
, vol.13
, Issue.1
, pp. 47-50
-
-
Hendriks, J.M.1
Zindler, J.D.2
Van Der, L.A.3
Pattynama, P.M.T.4
Van Sambeek, M.R.H.M.5
Bosch, J.L.6
Van Dijk, L.C.7
-
15
-
-
39149088017
-
Flow impairment during protected carotid artery stenting: Impact of filter device design
-
DOI 10.1583/07-2252.1
-
Roffi M, Greutmann M, Schwarz U, et al. Flow impairment during protected carotid artery stenting: impact of filter device design. J Endovasc Ther. 2008;15:103-109. (Pubitemid 351252238)
-
(2008)
Journal of Endovascular Therapy
, vol.15
, Issue.1
, pp. 103-109
-
-
Roffi, M.1
Greutmann, M.2
Schwarz, U.3
Luscher, T.F.4
Eberli, F.R.5
Amann-Vesti, B.6
-
16
-
-
43049150398
-
Wall apposition assessment and performance comparison of distal protection filters
-
Finol EA, Siewiorek GM, Scotti CM, et al. Wall apposition assessment and performance comparison of distal protection filters. J Endovasc Ther. 2008;15:177-186.
-
(2008)
J Endovasc Ther
, vol.15
, pp. 177-186
-
-
Finol, E.A.1
Siewiorek, G.M.2
Scotti, C.M.3
-
17
-
-
35348972924
-
In vitro performance assessment of distal protection devices for carotid artery stenting: Effect of physiological anatomy on vascular resistance
-
DOI 10.1583/1545-1550(2007)14[712:IVPAOD]2.0.CO;2
-
Siewiorek GM, Wholey MH, Finol EA. In vitro performance assessment of distal protection devices for carotid artery stenting: effect of physiological anatomy on vascular resistance. J Endovasc Ther. 2007;14:712-724. (Pubitemid 47598199)
-
(2007)
Journal of Endovascular Therapy
, vol.14
, Issue.5
, pp. 712-724
-
-
Siewiorek, G.M.1
Wholey, M.H.2
Finol, E.A.3
-
18
-
-
52149117617
-
Vascular resistance in the carotid artery: An in vitro investigation of embolic protection filters
-
Siewiorek GM, Wholey MH, Finol EA. Vascular resistance in the carotid artery: an in vitro investigation of embolic protection filters. J Vasc Interv Radiol. 2008;19:1467-1476.
-
(2008)
J Vasc Interv Radiol
, vol.19
, pp. 1467-1476
-
-
Siewiorek, G.M.1
Wholey, M.H.2
Finol, E.A.3
-
19
-
-
74949085047
-
In vitro performance assessment of distal protection filters: Pulsatile flow conditions
-
Siewiorek GM, Wholey MH, Finol EA. In vitro performance assessment of distal protection filters: pulsatile flow conditions. J Endovasc Ther. 2009;16:735-743.
-
(2009)
J Endovasc Ther
, vol.16
, pp. 735-743
-
-
Siewiorek, G.M.1
Wholey, M.H.2
Finol, E.A.3
-
20
-
-
0032773052
-
Characterization of common carotid artery blood-flow waveforms in normal human subjects
-
DOI 10.1088/0967-3334/20/3/301, PII S0967333499975457
-
Holdsworth DW, Norley CJ, Frayne R, et al. Characterization of common carotid artery blood-flow waveforms in normal human subjects. Physiol Meas. 1999;20:219-240. (Pubitemid 29399835)
-
(1999)
Physiological Measurement
, vol.20
, Issue.3
, pp. 219-240
-
-
Holdsworth, D.W.1
Norley, C.J.D.2
Frayne, R.3
Steinman, D.A.4
Rutt, B.K.5
-
21
-
-
7544234586
-
Extraction of pulmonary vascular compliance, pulmonary vascular resistance, and right ventricular work from single-pressure and doppler flow measurements in children with pulmonary hypertension: A new method for evaluating reactivity - In vitro and clinical studies
-
DOI 10.1161/01.CIR.0000146818.60588.40
-
Weinberg CE, Hertzberg JR, Ivy DD, et al. Extraction of pulmonary vascular compliance, pulmonary vascular resistance, and right ventricular work from single-pressure and Doppler flow measurements in children with pulmonary hypertension: a new method for evaluating reactivity: in vitro and clinical studies. Circulation. 2004;110:2609-2617. (Pubitemid 39453010)
-
(2004)
Circulation
, vol.110
, Issue.17
, pp. 2609-2617
-
-
Weinberg, C.E.1
Hertzberg, J.R.2
Ivy, D.D.3
Kirby, K.S.4
Chan, K.C.5
Valdes-Cruz, L.6
Shandas, R.7
-
22
-
-
0037351047
-
Carotid stenting with filter protection: Correlation of ACT values with angiographic and histopathologic findings
-
Castellani L, Causin F, Danieli D, et al. Carotid stenting with filter protection. Correlation of ACT values with angiographic and histopathologic findings. J Neuroradiol. 2003;30:103-108. (Pubitemid 36383487)
-
(2003)
Journal of Neuroradiology
, vol.30
, Issue.2
, pp. 103-108
-
-
Castellan, L.1
Causin, F.2
Danieli, D.3
Perini, S.4
-
23
-
-
80051715724
-
Increases in cerebrovascular impedance in older adults
-
Zhu YS, Tseng BY, Shibata S, et al. Increases in cerebrovascular impedance in older adults. J Appl Physiol. 2011;111:376-381.
-
(2011)
J Appl Physiol
, vol.111
, pp. 376-381
-
-
Zhu, Y.S.1
Tseng, B.Y.2
Shibata, S.3
-
25
-
-
1842682027
-
Comparison of 4 Cerebral Protection Filters for Carotid Angioplasty: An In Vitro Experiment Focusing on Carotid Anatomy
-
DOI 10.1583/03-1131.1
-
Order BM, Glass C, Liess C, et al. Comparison of 4 cerebral protection filters for carotid angioplasty: an in vitro experiment focusing on carotid anatomy. J Endovasc Ther. 2004; 11:211-218. (Pubitemid 38481076)
-
(2004)
Journal of Endovascular Therapy
, vol.11
, Issue.2
, pp. 211-218
-
-
Order, B.-M.1
Glass, C.2
Liess, C.3
Heller, M.4
Muller-Hulsbeck, S.5
-
26
-
-
84860749236
-
The effect of tortuosity on five different cerebral protection devices in an ex-vivo model
-
Presented at the
-
Shah AR, Lipsitz EC, Scher L, et al. The effect of tortuosity on five different cerebral protection devices in an ex-vivo model. Presented at the Eastern Vascular Society; September 24-26, 2009; Philadelphia, Pennsylvania, USA.
-
Eastern Vascular Society; September 24-26, 2009; Philadelphia, Pennsylvania, USA
-
-
Shah, A.R.1
Lipsitz, E.C.2
Scher, L.3
-
27
-
-
20444444559
-
Morphometric analysis of particulate debris extracted by four different embolic protection devices from coronary arteries, aortocoronary saphenous vein conduits, and carotid arteries
-
DOI 10.1016/j.amjcard.2005.02.006, PII S0002914905004637
-
Quan VH, Huynh R, Seifert PA, et al. Morphometric analysis of particulate debris extracted by four different embolic protection devices from coronary arteries, aortocoronary saphenous vein conduits, and carotid arteries. Am J Cardiol. 2005;95:1415-1419. (Pubitemid 40824759)
-
(2005)
American Journal of Cardiology
, vol.95
, Issue.12
, pp. 1415-1419
-
-
Quan, V.-H.1
Huynh, R.2
Seifert, P.A.3
Kuchela, A.4
Chen, W.-H.5
Sutsch, G.6
Eisenhauer, A.C.7
Rogers, C.8
-
28
-
-
80051669765
-
The association of clinical variables and filter design with carotid artery stenting thirty-day outcome
-
Siewiorek GM, Krafty RT, Wholey MH, et al. The association of clinical variables and filter design with carotid artery stenting thirty-day outcome. Eur J Vasc Endovasc Surg. 2011;42: 282-291.
-
(2011)
Eur J Vasc Endovasc Surg
, vol.42
, pp. 282-291
-
-
Siewiorek, G.M.1
Krafty, R.T.2
Wholey, M.H.3
-
30
-
-
33646040403
-
Carotid stenting with distal protection in high surgical risk patients: The BEACH trial 30 day results
-
White CJ, Iyer SS, Hopkins LN, et al. Carotid stenting with distal protection in high surgical risk patients: the BEACH trial 30 day results. Catheter Cardiovasc Interv. 2006;67:503-512.
-
(2006)
Catheter Cardiovasc Interv
, vol.67
, pp. 503-512
-
-
White, C.J.1
Iyer, S.S.2
Hopkins, L.N.3
-
31
-
-
45849105563
-
Carotid artery revascularization in high surgical risk patients with the NexStent and the FilterWire EX/EZ: 1-year results in the CABERNET trial
-
DOI 10.1002/ccd.21564
-
Hopkins LN, Myla S, Grube E, et al. Carotid artery revascularization in high surgical risk patients with the NexStent and the FilterWire EX/EZ: 1-year results in the CABERNET trial. Catheter Cardiovasc Interv. 2008;7:950-960. (Pubitemid 351951320)
-
(2008)
Catheterization and Cardiovascular Interventions
, vol.71
, Issue.7
, pp. 950-960
-
-
Hopkins, L.N.1
Myla, S.2
Grube, E.3
Wehman, J.C.4
Levy, E.I.5
Bersin, R.M.6
Joye, J.D.7
Allocco, D.J.8
Kelley, L.9
Baim, D.S.10
-
32
-
-
84860745028
-
Safety outcomes from the PROTECT Carotid Artery Stenting Multicenter Study
-
Presented at the
-
Chaturvedi S, Gray WA, Matsumura J. Safety outcomes from the PROTECT Carotid Artery Stenting Multicenter Study. Presented at the International Stroke Conference; February 17-20, 2009; San Diego, California, USA.
-
International Stroke Conference; February 17-20, 2009; San Diego, California, USA
-
-
Chaturvedi, S.1
Gray, W.A.2
Matsumura, J.3
-
33
-
-
34547626458
-
Carotid artery stenting with emboli protection surveillance study: Thirty-day results of the CASES-PMS study
-
DOI 10.1002/ccd.21222
-
Katzen BT, Criado FJ, Ramee SR, et al. Carotid artery stenting with emboli protection surveillance study: thirty-day results of the CASES-PMS study. Catheter Cardiovasc Interv. 2007; 70:316-323. (Pubitemid 47206049)
-
(2007)
Catheterization and Cardiovascular Interventions
, vol.70
, Issue.2
, pp. 316-323
-
-
Katzen, B.T.1
Criado, F.J.2
Ramee, S.R.3
Massop, D.W.4
Hopkins, L.N.5
Donohoe, D.6
Cohen, S.A.7
Mauri, L.8
-
34
-
-
33746480325
-
Protected carotid stenting in high-surgical-risk patients: The ARCHeR results
-
DOI 10.1016/j.jvs.2006.03.044, PII S0741521406007452
-
Gray WA, Hopkins LN, Yadav S, et al. Protected carotid stenting in high-surgical-risk patients: the ARCHeR results. J Vasc Surg. 2006;44: 258-268. (Pubitemid 44142925)
-
(2006)
Journal of Vascular Surgery
, vol.44
, Issue.2
, pp. 258-268
-
-
Gray, W.A.1
Hopkins, L.N.2
Yadav, S.3
Davis, T.4
Wholey, M.5
Atkinson, R.6
Cremonesi, A.7
Fairman, R.8
Walker, G.9
Verta, P.10
Popma, J.11
Virmani, R.12
Cohen, D.J.13
-
35
-
-
34748922895
-
The CAPTURE registry: Analysis of strokes resulting from carotid artery stenting in the post approval setting: timing, location, severity, and type
-
Fairman R, Gray WA, Scicli AP, et al. The CAPTURE registry: analysis of strokes resulting from carotid artery stenting in the post approval setting: timing, location, severity, and type. Ann Surg. 2007;246:551-558.
-
(2007)
Ann Surg
, vol.246
, pp. 551-558
-
-
Fairman, R.1
Gray, W.A.2
Scicli, A.P.3
-
36
-
-
69949104161
-
Thirty-day outcomes for carotid artery stenting in 6320 patients from 2 prospective, multicenter, high-surgical-risk registries
-
Gray WA, Chaturvedi S, Verta P, et al. Thirty-day outcomes for carotid artery stenting in 6320 patients from 2 prospective, multicenter, high-surgical-risk registries. Circ Cardiovasc Interv. 2009;2:159-166.
-
(2009)
Circ Cardiovasc Interv
, vol.2
, pp. 159-166
-
-
Gray, W.A.1
Chaturvedi, S.2
Verta, P.3
-
37
-
-
33744977874
-
Protected Carotid Stenting in High-Risk Patients With Severe Carotid Artery Stenosis
-
DOI 10.1016/j.jacc.2005.12.076, PII S0735109706008503
-
Safian RD, Bresnahan JF, Jaff MR, et al. Protected carotid stenting in high-risk patients with severe carotid artery stenosis. J Am Coll Cardiol. 2006;47:2384-2389. (Pubitemid 43866375)
-
(2006)
Journal of the American College of Cardiology
, vol.47
, Issue.12
, pp. 2384-2389
-
-
Safian, R.D.1
Bresnahan, J.F.2
Jaff, M.R.3
Foster, M.4
Bacharach, J.M.5
Maini, B.6
Turco, M.7
Myla, S.8
Eles, G.9
Ansel, G.M.10
|