메뉴 건너뛰기




Volumn 81, Issue 6, 2012, Pages 1128-1133

Feasibility of using automated insufflated carbon dioxide (CO 2) for luminal distension in 3.0 T MR colonography

Author keywords

Carbon dioxide (CO 2); Colonic distension; Magnetic resonance (MR) colonography

Indexed keywords

BARIUM SULFATE; CARBON DIOXIDE; GADOLINIUM; IODINE; LACTULOSE; MACROGOL;

EID: 84860709076     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2011.02.067     Document Type: Article
Times cited : (10)

References (19)
  • 1
    • 34147198820 scopus 로고    scopus 로고
    • MR colonography with limited bowel preparation compared with optical colonoscopy in patients at increased risk for colorectal cancer
    • J. Florie, S. Jensch, and R.A. Nievelstein MR colonography with limited bowel preparation compared with optical colonoscopy in patients at increased risk for colorectal cancer Radiology 243 1 2007 122 131
    • (2007) Radiology , vol.243 , Issue.1 , pp. 122-131
    • Florie, J.1    Jensch, S.2    Nievelstein, R.A.3
  • 2
    • 34248142607 scopus 로고    scopus 로고
    • Magnetic resonance colonography without bowel cleansing: A prospective cross sectional study in a screening population
    • C.A. Kuehle, J. Langhorst, and S.C. Ladd Magnetic resonance colonography without bowel cleansing: a prospective cross sectional study in a screening population Gut 56 8 2007 1079 1085
    • (2007) Gut , vol.56 , Issue.8 , pp. 1079-1085
    • Kuehle, C.A.1    Langhorst, J.2    Ladd, S.C.3
  • 3
    • 29444437387 scopus 로고    scopus 로고
    • Colorectal polyps: Detection with dark-lumen MR-colonography versus conventional colonoscopy
    • D. Hartmann, B. Bassler, and D. Schilling Colorectal polyps: detection with dark-lumen MR-colonography versus conventional colonoscopy Radiology 238 1 2006 143 149
    • (2006) Radiology , vol.238 , Issue.1 , pp. 143-149
    • Hartmann, D.1    Bassler, B.2    Schilling, D.3
  • 4
    • 77952098355 scopus 로고    scopus 로고
    • Magnetic resonance (MR) colonography in the detection of colorectal lesions: A systematic review of prospective studies
    • F.M. Zijta, S. Bipat, and J. Stoker Magnetic resonance (MR) colonography in the detection of colorectal lesions: a systematic review of prospective studies Eur Radiol 20 5 2010 1031 1046
    • (2010) Eur Radiol , vol.20 , Issue.5 , pp. 1031-1046
    • Zijta, F.M.1    Bipat, S.2    Stoker, J.3
  • 5
    • 34548686351 scopus 로고    scopus 로고
    • MR colonography with limited bowel preparation: Patient acceptance compared with that of full-preparation colonoscopy
    • J. Florie, E. Birnie, and R.E. van Gelder MR colonography with limited bowel preparation: patient acceptance compared with that of full-preparation colonoscopy Radiology 245 1 2007 150 159
    • (2007) Radiology , vol.245 , Issue.1 , pp. 150-159
    • Florie, J.1    Birnie, E.2    Van Gelder, R.E.3
  • 6
    • 33644841724 scopus 로고    scopus 로고
    • Automated insufflation of carbon dioxide for MDCT colonography: Distension and patient experience compared with manual insufflation
    • D. Burling, S.A. Taylor, and S. Halligan Automated insufflation of carbon dioxide for MDCT colonography: distension and patient experience compared with manual insufflation AJR Am J Roentgenol 186 1 2006 96 103
    • (2006) AJR Am J Roentgenol , vol.186 , Issue.1 , pp. 96-103
    • Burling, D.1    Taylor, S.A.2    Halligan, S.3
  • 8
    • 45849109495 scopus 로고    scopus 로고
    • Dark-lumen MR-colonography with fecal tagging: A comparison of water enema and air methods of colonic distension for detecting colonic neoplasms
    • S. Rodriguez Gomez, M. Pagés Llinas, and A. Castells Garangou Dark-lumen MR-colonography with fecal tagging: a comparison of water enema and air methods of colonic distension for detecting colonic neoplasms Eur Radiol 18 7 2008 1396 1405
    • (2008) Eur Radiol , vol.18 , Issue.7 , pp. 1396-1405
    • Rodriguez Gomez, S.1    Pagés Llinas, M.2    Castells Garangou, A.3
  • 11
    • 77649262234 scopus 로고    scopus 로고
    • CT-colonography with minimal bowel preparation: Evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes
    • M.H. Liedenbaum, A.H. de Vries, and C.I. Gouw CT-colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes Eur Radiol 20 2 2010 367 376
    • (2010) Eur Radiol , vol.20 , Issue.2 , pp. 367-376
    • Liedenbaum, M.H.1    De Vries, A.H.2    Gouw, C.I.3
  • 12
    • 34047130221 scopus 로고    scopus 로고
    • Magnetic resonance colonography with limited bowel preparation: A comparison of three strategies
    • J. Florie, R.E. van Gelder, and B. Haberkorn Magnetic resonance colonography with limited bowel preparation: a comparison of three strategies J Magn Reson Imaging 25 4 2007 766 774
    • (2007) J Magn Reson Imaging , vol.25 , Issue.4 , pp. 766-774
    • Florie, J.1    Van Gelder, R.E.2    Haberkorn, B.3
  • 13
    • 1842537944 scopus 로고    scopus 로고
    • Screening of colonic tumors by air-inflated magnetic resonance (MR) colonography
    • W.W.M. Lam, W.K. Leung, J.K.L. Wu, N.M.C. So, and J.J.Y. Sung Screening of colonic tumors by air-inflated magnetic resonance (MR) colonography J Magn Reson Imaging 19 2004 447 452
    • (2004) J Magn Reson Imaging , vol.19 , pp. 447-452
    • Lam, W.W.M.1    Leung, W.K.2    Wu, J.K.L.3    So, N.M.C.4    Sung, J.J.Y.5
  • 14
    • 84860721000 scopus 로고    scopus 로고
    • Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection
    • PMID: 21131152
    • A.N. Keeling, M.M. Morrin, and C. McKenzie Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection Eur J Radiol 2010 PMID: 21131152
    • (2010) Eur J Radiol
    • Keeling, A.N.1    Morrin, M.M.2    McKenzie, C.3
  • 16
    • 33846457874 scopus 로고    scopus 로고
    • European Society of Gastrointestinal and Abdominal Radiology (ESGAR): Consensus statement on CT-colonography
    • S.A. Taylor, A. Laghi, P. Lefere, S. Halligan, and J. Stoker European Society of Gastrointestinal and Abdominal Radiology (ESGAR): consensus statement on CT-colonography Eur Radiol 17 2 2007 575 579
    • (2007) Eur Radiol , vol.17 , Issue.2 , pp. 575-579
    • Taylor, S.A.1    Laghi, A.2    Lefere, P.3    Halligan, S.4    Stoker, J.5
  • 17
    • 0036516942 scopus 로고    scopus 로고
    • CT-colonography: Colonic distention improved by dual positioning but not intravenous glucagon
    • M.M. Morrin, R.J. Farrell, M.T. Keogan, J.B. Kruskal, C.S. Yam, and V. Raptopoulos CT-colonography: colonic distention improved by dual positioning but not intravenous glucagon Eur Radiol 12 2002 525 530
    • (2002) Eur Radiol , vol.12 , pp. 525-530
    • Morrin, M.M.1    Farrell, R.J.2    Keogan, M.T.3    Kruskal, J.B.4    Yam, C.S.5    Raptopoulos, V.6
  • 19
    • 42649084712 scopus 로고    scopus 로고
    • High-resolution T2-weighted abdominal magnetic resonance imaging using respiratory triggering: Impact of butylscopolamine on image quality
    • M. Wagner, C. Klessen, and M. Rief High-resolution T2-weighted abdominal magnetic resonance imaging using respiratory triggering: impact of butylscopolamine on image quality Acta Radiol 49 4 2008 376 382
    • (2008) Acta Radiol , vol.49 , Issue.4 , pp. 376-382
    • Wagner, M.1    Klessen, C.2    Rief, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.