메뉴 건너뛰기




Volumn 53, Issue 3, 2012, Pages 1414-1421

Femtosecond lenticule extraction (FLEx): Clinical results, interface evaluation, and intraocular pressure variation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANIMAL EXPERIMENT; ARTICLE; ASTIGMATISM; CLINICAL ARTICLE; CLINICAL TRIAL; CORNEA; DEVICE SAFETY; EYE REFRACTION; FEMALE; FEMTOSECOND LENTICULE EXTRACTION; FOLLOW UP; HUMAN; HUMAN TISSUE; HYPERMETROPIA; INTRAOCULAR PRESSURE; LASER SAFETY; LASER SURGERY; MALE; MYOPIA; NONHUMAN; OCULOPLETHYSMOGRAPHY; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RABBIT; SCANNING ELECTRON MICROSCOPY; TONOMETER; VISUAL ACUITY; ANIMAL; CADAVER; CORNEA STROMA; METHODOLOGY; MIDDLE AGED; PATHOLOGY; PATHOPHYSIOLOGY; PHOTOREFRACTIVE KERATECTOMY; PHYSIOLOGY;

EID: 84860578694     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.11-8808     Document Type: Article
Times cited : (90)

References (28)
  • 1
    • 58249124533 scopus 로고    scopus 로고
    • Femtosecond lasers in ophthalmology
    • Soong HK, Malta JB. Femtosecond lasers in ophthalmology. Am J Ophthalmol. 2009;147:189-197.e182.
    • (2009) Am J Ophthalmol , vol.147 , Issue.189-197
    • Soong, H.K.1    Malta, J.B.2
  • 2
    • 77952378580 scopus 로고    scopus 로고
    • Femtosecond laser in laser in situ keratomileusis
    • Salomao MQ, Wilson SE. Femtosecond laser in laser in situ keratomileusis. J Cataract Refract Surg. 2010;36:1024-1032.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 1024-1032
    • Salomao, M.Q.1    Wilson, S.E.2
  • 3
    • 33746765206 scopus 로고    scopus 로고
    • Femtosecond laser-assisted corneal flap cuts: Morphology, accuracy, and histopathology
    • Holzer MP, Rabsilber TM, Auffarth GU. Femtosecond laser-assisted corneal flap cuts: morphology, accuracy, and histopathology. Invest Ophthalmol Vis Sci. 2006;47:2828-2831.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 2828-2831
    • Holzer, M.P.1    Rabsilber, T.M.2    Auffarth, G.U.3
  • 5
    • 33751327346 scopus 로고    scopus 로고
    • Transient light-sensitivity syndrome after laser in situ keratomileusis with the femtosecond laser. Incidence and prevention
    • Munoz G, Albarran-Diego C, Sakla HF, Javaloy J, Alio JL. Transient light-sensitivity syndrome after laser in situ keratomileusis with the femtosecond laser. Incidence and prevention. J Cataract Refract Surg. 2006;32:2075-2079.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2075-2079
    • Munoz, G.1    Albarran-Diego, C.2    Sakla, H.F.3    Javaloy, J.4    Alio, J.L.5
  • 6
    • 38349120484 scopus 로고    scopus 로고
    • Overview of commercially available femtosecond lasers in refractive surgery
    • Lubatschowski H. Overview of commercially available femtosecond lasers in refractive surgery. J Refract Surg. 2008;24:S102-S107.
    • (2008) J Refract Surg , vol.24
    • Lubatschowski, H.1
  • 7
    • 49649099285 scopus 로고    scopus 로고
    • First efficacy and safety study of femtosecond lenticule extraction for the correction of myopia: Sixmonth results
    • Sekundo W, Kunert K, Russmann C, et al. First efficacy and safety study of femtosecond lenticule extraction for the correction of myopia: sixmonth results. J Cataract Refract Surg. 2008;34:1513-1520.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1513-1520
    • Sekundo, W.1    Kunert, K.2    Russmann, C.3
  • 8
    • 79952019652 scopus 로고    scopus 로고
    • Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: Results of a 6 month prospective study
    • Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. 2011;95:335-339.
    • (2011) Br J Ophthalmol , vol.95 , pp. 335-339
    • Sekundo, W.1    Kunert, K.S.2    Blum, M.3
  • 9
    • 78650463655 scopus 로고    scopus 로고
    • Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgery
    • Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: all-in-one femtosecond laser refractive surgery. J Cataract Refract Surg. 2011;37:127-137.
    • (2011) J Cataract Refract Surg , vol.37 , pp. 127-137
    • Shah, R.1    Shah, S.2    Sengupta, S.3
  • 10
    • 77955661467 scopus 로고    scopus 로고
    • Femtosecond lenticule extraction for the correction of myopia: Preliminary 6-month results
    • Blum M, Kunert K, Schroder M, Sekundo W. Femtosecond lenticule extraction for the correction of myopia: preliminary 6-month results. Graefes Arch Clin Exp Ophthalmol. 2010;248:1019-1027.
    • (2010) Graefes Arch Clin Exp Ophthalmol , vol.248 , pp. 1019-1027
    • Blum, M.1    Kunert, K.2    Schroder, M.3    Sekundo, W.4
  • 11
    • 0031873911 scopus 로고    scopus 로고
    • The picosecond laser for nonmechanical laser in situ keratomileusis
    • Krueger RR, Juhasz T, Gualano A, Marchi V. The picosecond laser for nonmechanical laser in situ keratomileusis. J Refract Surg. 1998;14:467-469.
    • (1998) J Refract Surg , vol.14 , pp. 467-469
    • Krueger, R.R.1    Juhasz, T.2    Gualano, A.3    Marchi, V.4
  • 12
    • 0037345992 scopus 로고    scopus 로고
    • First clinical results with the femtosecond neodynium-glass laser in refractive surgery
    • Ratkay-Traub I, Ferincz IE, Juhasz T, Kurtz RM, Krueger RR. First clinical results with the femtosecond neodynium-glass laser in refractive surgery. J Refract Surg. 2003;19:94-103.
    • (2003) J Refract Surg , vol.19 , pp. 94-103
    • Ratkay-Traub, I.1    Ferincz, I.E.2    Juhasz, T.3    Kurtz, R.M.4    Krueger, R.R.5
  • 13
    • 77957356233 scopus 로고    scopus 로고
    • In vivo real-time intraocular pressure variations during LASIK flap creation
    • Chaurasia SS, Luengo Gimeno F, Tan K, et al. In vivo real-time intraocular pressure variations during LASIK flap creation. Invest Ophthalmol Vis Sci. 2010;51:4641-4645.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 4641-4645
    • Chaurasia, S.S.1    Luengo Gimeno, F.2    Tan, K.3
  • 14
    • 80052718969 scopus 로고    scopus 로고
    • Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters
    • Kunert KS, Blum M, Duncker GI, Sietmann R, Heichel J. Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters. Graefes Arch Clin Exp Ophthalmol. 2011;249:1417-1424.
    • (2011) Graefes Arch Clin Exp Ophthalmol , vol.249 , pp. 1417-1424
    • Kunert, K.S.1    Blum, M.2    Duncker, G.I.3    Sietmann, R.4    Heichel, J.5
  • 15
    • 33846898325 scopus 로고    scopus 로고
    • Porcine model to compare real-time intraocular pressure during LASIK with a mechanical microkeratome and femtosecond laser
    • Hernandez-Verdejo JL, Teus MA, Roman JM, Bolivar G. Porcine model to compare real-time intraocular pressure during LASIK with a mechanical microkeratome and femtosecond laser. Invest Ophthalmol Vis Sci. 2007;48:68-72.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 68-72
    • Hernandez-Verdejo, J.L.1    Teus, M.A.2    Roman, J.M.3    Bolivar, G.4
  • 16
    • 73249114023 scopus 로고    scopus 로고
    • Effect of a suction device for femtosecond laser on anterior chamber depth and crystalline lens position measured by OCT
    • Kunert KS, Blum M, Reich M, Dick M, Russmann C. Effect of a suction device for femtosecond laser on anterior chamber depth and crystalline lens position measured by OCT. J Refract Surg. 2009;25:1005-1011.
    • (2009) J Refract Surg , vol.25 , pp. 1005-1011
    • Kunert, K.S.1    Blum, M.2    Reich, M.3    Dick, M.4    Russmann, C.5
  • 17
    • 79956342020 scopus 로고    scopus 로고
    • Intraoperative and postoperative complications of laser in situ keratomileusis flap creation using IntraLase femtosecond laser and mechanical microkeratomes
    • Espandar L, Meyer J. Intraoperative and postoperative complications of laser in situ keratomileusis flap creation using IntraLase femtosecond laser and mechanical microkeratomes. Middle East Afr J Ophthalmol. 2010;17:56-59.
    • (2010) Middle East Afr J Ophthalmol , vol.17 , pp. 56-59
    • Espandar, L.1    Meyer, J.2
  • 19
    • 36249026598 scopus 로고    scopus 로고
    • Retinal detachment after laser in situ keratomileusis in myopic eyes
    • Qin B, Huang L, Zeng J, Hu J. Retinal detachment after laser in situ keratomileusis in myopic eyes. Am J Ophthalmol. 2007;144:921-923.
    • (2007) Am J Ophthalmol , vol.144 , pp. 921-923
    • Qin, B.1    Huang, L.2    Zeng, J.3    Hu, J.4
  • 20
    • 0035087513 scopus 로고    scopus 로고
    • Laser in situ keratomileusisinduced optic neuropathy
    • Cameron BD, Saffra NA, Strominger MB. Laser in situ keratomileusisinduced optic neuropathy. Ophthalmology. 2001;108:660-665.
    • (2001) Ophthalmology , vol.108 , pp. 660-665
    • Cameron, B.D.1    Saffra, N.A.2    Strominger, M.B.3
  • 21
    • 27344458727 scopus 로고    scopus 로고
    • Vitreoretinal surgery for macular hole after laser assisted in situ keratomileusis for the correction of myopia
    • Arevalo JF, Rodriguez FJ, Rosales-Meneses JL, et al. Vitreoretinal surgery for macular hole after laser assisted in situ keratomileusis for the correction of myopia. Br J Ophthalmol. 2005;89:1423-1426.
    • (2005) Br J Ophthalmol , vol.89 , pp. 1423-1426
    • Arevalo, J.F.1    Rodriguez, F.J.2    Rosales-Meneses, J.L.3
  • 22
    • 78649366724 scopus 로고    scopus 로고
    • Alternative applications of the femtosecond laser in ophthalmology
    • Kullman G, Pineda R 2nd. Alternative applications of the femtosecond laser in ophthalmology. Semin Ophthalmol. 2010;25:256-264.
    • (2010) Semin Ophthalmol , vol.25 , pp. 256-264
    • Kullman, G.1    Pineda II, R.2
  • 23
    • 80052718969 scopus 로고    scopus 로고
    • Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters
    • Kunert KS, Blum M, Duncker GI, Sietmann R, Heichel J. Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters. Graefes Arch Clin Exp Ophthalmol. 2011;249:1417-1424.
    • (2011) Graefes Arch Clin Exp Ophthalmol , vol.249 , pp. 1417-1424
    • Kunert, K.S.1    Blum, M.2    Duncker, G.I.3    Sietmann, R.4    Heichel, J.5
  • 25
    • 79751527489 scopus 로고    scopus 로고
    • Surface quality of porcine corneal lenticules after femtosecond lenticule extraction
    • Heichel J, Blum M, Duncker GI, Sietmann R, Kunert KS. Surface quality of porcine corneal lenticules after femtosecond lenticule extraction. Ophthalmic Res. 2011;46:107-112.
    • (2011) Ophthalmic Res , vol.46 , pp. 107-112
    • Heichel, J.1    Blum, M.2    Duncker, G.I.3    Sietmann, R.4    Kunert, K.S.5
  • 26
    • 0032038042 scopus 로고    scopus 로고
    • A method for examining surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis: Predictor of optical and functional outcomes
    • Vinciguerra P, Azzolini M, Radice P, Sborgia M, De Molfetta V. A method for examining surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis: predictor of optical and functional outcomes. J Refract Surg. 1998; 14:S204-S206.
    • (1998) J Refract Surg , vol.14
    • Vinciguerra, P.1    Azzolini, M.2    Radice, P.3    Sborgia, M.4    de Molfetta, V.5
  • 27
    • 84861157784 scopus 로고    scopus 로고
    • FLEx Option. In, Jena, Germany: Carl Zeiss Meditec AG
    • FLEx Option. In: Visante Operation Manual. Jena, Germany: Carl Zeiss Meditec AG; 2011;24-25.
    • (2011) Visante Operation Manual , pp. 24-25
  • 28
    • 34247625520 scopus 로고    scopus 로고
    • Comparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomes
    • Sarayba MA, Ignacio TS, Binder PS, Tran DB. Comparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomes. Cornea. 2007;26: 446-451.
    • (2007) Cornea , vol.26 , pp. 446-451
    • Sarayba, M.A.1    Ignacio, T.S.2    Binder, P.S.3    Tran, D.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.