메뉴 건너뛰기




Volumn 25, Issue 11, 2009, Pages 1005-1011

Effect of a suction device for femtosecond laser on anterior chamber depth and crystalline lens position measured by OCT

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANTERIOR EYE CHAMBER; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; CONJUNCTIVAL HYPEREMIA; CONTACT LENS; DEPTH PERCEPTION; EYE SURGERY; FEMALE; FEMTOSECOND LASER; HUMAN; KERATOMILEUSIS; LASER SURGERY; LENS; MALE; OPTICAL COHERENCE TOMOGRAPHY; PRESBYOPIA; PRIORITY JOURNAL; SUCTION; SURGICAL INSTRUMENT; VACUUM;

EID: 73249114023     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081597X-20091016-06     Document Type: Article
Times cited : (8)

References (11)
  • 1
    • 33745283956 scopus 로고    scopus 로고
    • One thousand consecutive IntraLase laser in situ keratomileusis flaps
    • Binder PS. One thousand consecutive IntraLase laser in situ keratomileusis flaps. J Cataract Refract Surg. 2006;32:962-969.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 962-969
    • Binder, P.S.1
  • 3
    • 0034765554 scopus 로고    scopus 로고
    • Experimental increase in accommodative potential after neodymium: Yttrium-aluminum-garnet laser photodisruption of paired cadaver lenses
    • Krueger RR, Sun XK, Stroh J, Myers R. Experimental increase in accommodative potential after neodymium: yttrium-aluminum-garnet laser photodisruption of paired cadaver lenses. Ophthalmology. 2001;108:2122-2129.
    • (2001) Ophthalmology , vol.108 , pp. 2122-2129
    • Krueger, R.R.1    Sun, X.K.2    Stroh, J.3    Myers, R.4
  • 4
    • 32244446481 scopus 로고    scopus 로고
    • First safety study of femtosecond laser photo-disruption in animal lenses: Tissue morphology and cataractogenesis
    • Krueger RR, Kuszak J, Lubatschowski H, Myers RI, Ripken T, Heisterkamp A. First safety study of femtosecond laser photo-disruption in animal lenses: tissue morphology and cataractogenesis. J Cataract Refract Surg. 2005;31:2386-2394.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 2386-2394
    • Krueger, R.R.1    Kuszak, J.2    Lubatschowski, H.3    Myers, R.I.4    Ripken, T.5    Heisterkamp, A.6
  • 6
    • 73249135812 scopus 로고    scopus 로고
    • Jena, Germany: Carl Zeiss Meditec AG;
    • OCT Instructions for Use. Jena, Germany: Carl Zeiss Meditec AG; 2006.
    • (2006) OCT Instructions for Use
  • 7
    • 4444312568 scopus 로고    scopus 로고
    • Static and dynamic analysis of the anterior segment with optical coherence tomography
    • Baikoff G, Lutun E, Ferraz C, Wei J. Static and dynamic analysis of the anterior segment with optical coherence tomography. J Cataract Refract Surg. 2004;30:1843-1850.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1843-1850
    • Baikoff, G.1    Lutun, E.2    Ferraz, C.3    Wei, J.4
  • 8
    • 33847139692 scopus 로고    scopus 로고
    • Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography
    • Nemeth G, Vajas A, Tsorbatzoglou A, Kolozsvari B, Modis L Jr, Berta A. Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography. J Cataract Refract Surg. 2007;33:443-447.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 443-447
    • Nemeth, G.1    Vajas, A.2    Tsorbatzoglou, A.3    Kolozsvari, B.4    Modis Jr, L.5    Berta, A.6
  • 9
    • 27144445263 scopus 로고    scopus 로고
    • Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer
    • Baikoff G, Jitsuo Jodai HJ, Bourgeon G. Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer. J Cataract Refract Surg. 2005;31:1722-1728.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1722-1728
    • Baikoff, G.1    Jitsuo Jodai, H.J.2    Bourgeon, G.3
  • 10
    • 34547226688 scopus 로고    scopus 로고
    • Comparison of anterior chamber depth measurements using IOLMaster, scanning peripheral anterior chamber depth analyser and anterior segment optical coherence tomography
    • Lavanya R, Teo L, Friedman DS, Aung HT, Baskaran M, Gao H, Alfred T, Seah SK, Kashiwagi K, Foster PJ, Aung T. Comparison of anterior chamber depth measurements using IOLMaster, scanning peripheral anterior chamber depth analyser and anterior segment optical coherence tomography. Br J Ophthalmol. 2007;91:1023-1026.
    • (2007) Br J Ophthalmol , vol.91 , pp. 1023-1026
    • Lavanya, R.1    Teo, L.2    Friedman, D.S.3    Aung, H.T.4    Baskaran, M.5    Gao, H.6    Alfred, T.7    Seah, S.K.8    Kashiwagi, K.9    Foster, P.J.10    Aung, T.11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.